Instructions-Parts
Simulation Advanced
3A2716D
Display Module
For Reactor®E-30i and E-XP2i and Reactor®2 and Integrated Reactor®2 proportioning
systems. For demonstration use only.
Kit No. 24U175
Important Safety Instructions
Read all warnings and instructions in this
manual and in the Reactor E-30i and E-XP2i
Operation manual. Save all instructions.
EN
Related Manuals
Manual Description
3A1705 Reactor E-30i and E-XP2i, Operation
3A1706 Reactor E-30i and E-XP2i, Repair-Parts
332636 Reactor 2 E-30i and E-XP2i, Operation
332637 Reactor 2 E-30i and E-XP2i, Repair-Parts
333023 Reactor 2 E-30 and E-XP2, Operation
333024 Reactor 2 E-30 and E-XP2, Repair-Parts
3A1244
Graco Control Architecture™Module
Programming, Instructions
ti19197a
Setup
Setup
The ADM (1) is installed with the Reactor 2/Integrated
Reactor 2 software. The simulation software on the blue
simulator token (4) overrides the Integrated Reactor
software and will simulate all of the functions of an ADM
installed on a Reactor 2 or Integrated Reactor 2.
1. Remove cover and ensure blue simulator token (4)
is inserted in the Advanced Display Module - ADM
(1). Replace cover.
2. Connect transformer (2) cable to the ADM left port.
Connect to a power outlet.
3. Turn on the ADM (1).
4. The ADM can now simulate all functions of an ADM
installed on a Reactor 2 or Integrated Reactor 2.
See Reactor manual for information about screens,
icons, and functions.
Use in Reactor 2 or
Use ADM in Other
Products
The module must be programmed with scrub software
to use the ADM in other products or simulators. Purchase scrub token 16N147.
1. Remove cover and blue simulator token (4).
2. Insert the scrub token. See manual 3A1244 for software downloading process.
3. Replace cover.
Return to Simulation
Mode
If the ADM needs to be converted back to a simulation
module, reinsert the blue simulator token (4).
Integrated Reactor 2
To use the simulation module in any Reactor 2 or Integrated Reactor 2, complete the following:
1. Disconnect the transformer from the power outlet.
2. Check that the ADM has the latest software.
a. Turn on the ADM and go in Setup Mode.
b. View the Advanced Screen - 4 and note the
software version.
c. Identify the latest software version for the Reac-
tor 2 or Integrated Reactor 2. The latest software version for the system can be found at
www.graco.com. If you have the latest software
continue to step 3.
d. Purchase a new black token (3) if the software
on the ADM is not the latest software. See manual 3A1244 for software downloading process.
3. Remove cover and remove the blue simulator token
(4).
4. Replace cover.