Graco 3A1332A User Manual

Instructions/Parts
24H255 3-Color Valve Stack Kit
To convert ProMix® 2KE Electronic Proportioners to a 3-color valve stack. For professional use only.
3A1332A
ENG
Important Safety Instructions
Read all warnings and instructions in this manual and in your separate ProMix 2KE manuals. Save these instructions.

Kit Parts

Ref. Description Qty.
701 MANIFOLD, valve, 3-color 1 702 O-RING 2 703 RETAINER, seat, dump valve 2 704 O-RING, PTFE 2 705 VALVE, dispense 2 707 SPACER, manifold 1 708 O-RING, PTFE 2 709 O-RING 1 710 FITTING 1 711 SCREW, cap, socket hd 4 712 PLUG 2 713 VALVE, solenoid; see page 2 2 715 TUBING, red; 5/32 in. (4 mm) OD;
6 ft (1.83 m); see page 3
716 TUBING, green; 5/32 in. (4 mm)
OD; 6 ft (1.83 m); see page 3
718 CONNECTOR, male; see page 2 4

Install the Dispense Valves

711
1
ll
2
1 1 1
3. Install new o-ring (708) on the spacer (707). Insta ne
w o-ring (709) on the bottom of the 1-color mani­fold (M). Align manifolds (M and 701). Install four screws (711). Torque to 8-10 ft-lb (11-14 N•m).
4. Reinstall the valve stack.
5. Install the solenoid valves. See page 2.
1
These parts are shipped loose.
2
Torque to 8-10 ft-lb (11-14 N•m).
M
708
1
1
703
704
701
702
707 709
1. Relieve the pressure and remove the valve stack as explained in your ProMix 2KE Repair/Parts manual 3A0870.
2. Remove the fitting and o-ring from the existi
-color manifold (M).
1
ng
705
708
710
712
ti16302a

Install the Solenoid Valves

1. Disconnect main power. Open the Control Box.
2. Install the two solenoid valves (713) in positions A2 and A3 as shown below.
3. Connect the wires. Solenoid A2: black to pin 7 and red to pin 8. Solenoid A3: black to pin 9 and red to pin 10.
ti15730a
+
-
BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED
PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN
SIG COM
713
A2 (713) A3 (713)
SOLENOID
4-WAY
12 VDC
SOLENOID
3-WAY
12 VDC
FLOW METER A
AIR FLOW SWITCH 1
ALARM
MANIFOLD
PURGE A
DOSE A1
PURGE B
DOSE B
DOSE A2
DOSE A3
GFB #1
3X CABLE
4. Remove the plugs from the ports at the bottom of the solenoid manifold. Install the male connectors (718).
5. Install the air tubing. See page 3.
A2 A3
RED
GREEN
ti16520a
718
1 2 3 4 5 6
A2: black to pin 7,
7
red to pin 8
8 9
A3: black to pin 9,
10
red to pin 10
11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
GFB 1 PRESSURE SWITCH/ AIR FLOW SWITCH 2
FLOW METER B
3X CABLE
SIG COM
PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN
2 3A1332A
Loading...
+ 2 hidden pages