Instructions
Radiator Tip Extension Kit 256952 for
HVLP EDGE Guns
313749A
- This manual contains kit installation instructions only -
For use with the following gun models: 256855, 256856, 257092, 257388, 257827
IMPORTANT SAFETY INSTRUCTIONS
For detailed sprayer information and warnings, see
Operation manual 313406 included with sprayer.
Pressure Relief Procedure
ti13731a
Relieve all fluid pressure in the system before you
install, remove, or replace any parts. See the
Pressure Relief Procedure below orrefer to
Operating instructions manual 313406.
ti13734a
1. Turn off turbine and air
supply to gun.
A
OR
ti13735a
2. Unlatch cup. 3. Open pressure relief (A) on pot until pressure
is completely relieved. Close relief.
ti13732a
Radiator Tip Extension Kit 256952
Relieve all fluid pressure in the system before you install,
remove, or replace any parts. See the Pressure Relief
Procedure on the cover or for more information refer to
Operating instructions manual 313406.
2
D
1
3
A
ti13731a
4
1. Turn off air supply to gun.
2. Relieve Pressure, see cover.
3. Remove air cap retaining ring (A) and air cap housĀing by hand.
4. Remove needle (see gun manual).
5. Install needle (1) into front of gun.
6. Slide fluid nozzle (2) over needle (1).
7. Slide air tube (4) over fluid nozzle (2).
8. Slide air cap retaining ring (A) over air tube until it
meets threaded end of gun (D). Hand tighten.
Ref. Part Describe Qty.
1 257106 NEEDLE 1
2 257105 NOZZLE, fluid 1
3 116571 CLIP, nozzle 1
4 257104 TUBE, air 1
All written and visual data contained in this document reflects the latest product information available at the time of publication.
2 313749A
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 313749
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2008, Graco Inc. is registered to I.S. EN ISO 9001
www.graco.com
Copyright 2009