Graco 312067E User Manual

Electrical Diagrams
312067E
Electric, Heated, Plural Component Proportioner
For spraying polyurethane foam and polyurea coatings. For professional use only.
Not approved for use in European explosive atmosphere locations.
Important Safety Instructions
Read all warnings and instructions in this manual and in manuals 312065 and 312066. Save all instruction manuals.
EN
See page 3 for model information, including maximum working pressure and approvals.

#ONFORMSTO!.3)5,
3TD#ERTIFIEDTO
#!.#3!3TD
#.O
Model E-XP1 Shown
TI10953a

Supplied Manuals

Contents
Supplied Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Simplified Schematics, Motor Controls . . . . . . . . . 4
E-20 and E-XP1 Series . . . . . . . . . . . . . . . . . . . . 4
E-30 and E-XP2 Series . . . . . . . . . . . . . . . . . . . . 5
Simplified Schematic, Heater Controls . . . . . . . . . 6
Simplified Schematic, Power Connections . . . . . . 7
Supplied Manuals
The following manuals are shipped with the Reactor™ Proportioner. Refer to these manuals for detailed equip­ment information.
Order Part 15M334 for a compact disk of Reactor manu­als translated in several languages.
Manuals are also available at www.graco.com.
Reactor Electric Proportioner - Operation Part Description
312065 Reactor Electric Proportioner,
Operation Manual (English)
Reactor Electric Proportioner - Repair/Parts
Detailed Schematic, Motor Controls . . . . . . . . . . . 8
E-20 and E-XP1 Series . . . . . . . . . . . . . . . . . . . . 8
E-30 and E-XP2 Series . . . . . . . . . . . . . . . . . . . . 9
Detailed Schematic, Heater Controls . . . . . . . . . . 10
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 12
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 12
Part Description
312066 Reactor Electric Proportioner,
Repair-Parts Manual (English)
Proportioning Pump Part Description
309577 Electric Reactor Displacement Pump
Repair-Parts Manual (English)
2 312067E

Models

E-20 SERIES
Models
Max Flow
Primary
Full Load Peak
Part, Series
259025, E 48 230V (1) 10,200 6,000 20 (9) 0.0104 (0.0395) 2000 (14, 140) 259030, E 24 400V (3) 10,200 6,000 20 (9) 0.0104 (0.0395) 2000 (14, 140) 259034, E 32 230V (3) 10,200 6,000 20 (9) 0.0104 (0.0395) 2000 (14, 140)
Amps*
Volt ag e (phase)
System Watts†
Heater Watts
Rate lb/min (kg/min)
Approximate Output per Cycle (A+B) gal. (liter)
Maximum Fluid Working Pressure psi (MPa, bar)
E-30 SERIES
Max Flow
Primary Part, Series
259026, F 78 230V (1) 17,900 10,200 30 (13.5) 0.0272 (0.1034) 2000 (14, 140) 259031, F 34 400V (3) 17,900 10,200 30 (13.5) 0.0272 (0.1034) 2000 (14, 140) 259035, F 50 230V (3) 17,900 10,200 30 (13.5) 0.0272 (0.1034) 2000 (14, 140) 259057, F 100 230V (1) 23,000 15,300 30 (13.5) 0.0272 (0.1034) 2000 (14, 140) 259058, F 62 230V (3) 23,000 15,300 30 (13.5) 0.0272 (0.1034) 2000 (14, 140) 259059, F 35 400V (3) 23,000 15,300 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
Full Load Peak Amps*
Volt ag e (phase)
System Watts†
Heater
Watts
Rate lb/min (kg/min)
Approximate Output per Cycle (A+B) gal. (liter)
Maximum Fluid Working Pressure psi (MPa, bar)
E-XP1 SERIES
Approximate
Primary
Full Load Peak
Part, Series
259024, E 69 230V (1) 15,800 10,200 1.0 (3.8) 0.0104 (0.0395) 2500 (17.2, 172) 259029, E 24 400V (3) 15,800 10,200 1.0 (3.8) 0.0104 (0.0395) 2500 (17.2, 172) 259033, E 43 230V (3) 15,800 10,200 1.0 (3.8) 0.0104 (0.0395) 2500 (17.2, 172)
Amps*
Voltag e (phase)
System Watts†
Heater Watts
Max Flow Rate gpm (lpm)
Output per Cycle (A+B) gal. (liter)
Maximum Fluid Working Pressure psi (MPa, bar)
E-XP2 SERIES
Approximate
Primary Part, Series
259028, F 100 230V (1) 23,000 15,300 2.0 (7.6) 0.0203 (0.0771) 3500 (24.1, 241) 259032, F 35 400V (3) 23,000 15,300 2.0 (7.6) 0.0203 (0.0771) 3500 (24.1, 241) 259036, F 62 230V (3) 23,000 15,300 2.0 (7.6) 0.0203 (0.0771) 3500 (24.1, 241)
Full Load Peak Amps*
Voltage (phase)
System Watts†
Heater
Watts
Max Flow Rate gpm (lpm)
Output per Cycle (A+B) gal. (liter)
Maximum Fluid Working Pressure psi (MPa, bar)
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix
chamber sizes may be less.
Total system watts, based on maximum hose length for each unit:
E-20 and E-XP1 series, 210 ft (64 m) maximum heated hose length, including whip hose.
E-30 and E-XP2 series, 310 ft (94.5 m) maximum heated hose length, including whip hose.
Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum
flow.
312067E 3

Simplified Schematics, Motor Controls

Simplified Schematics, Motor Controls

E-20 and E-XP1 Series

4 312067E
Loading...
+ 8 hidden pages