Graco 312064M User Manual

Electrical Diagrams
Hydraulic, Heated, Plural Component Proportioner
For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in this manual and in manuals 312062 and 313539. Save all instruction manuals.
312064M
EN
See page 3 for model information, including maximum working pressure and approvals.

#ONFORMSTO!.3)5,
3TD#ERTIFIEDTO
#!.#3!3TD
#.O
Model H-40 Shown
TI9830a

Contents

Contents
Supplied Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Simplified Schematic, Motor Controls . . . . . . . . . . 5
1-Phase Motor . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3-Phase Motor . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Simplified Schematic, Heater Controls . . . . . . . . . 7
Simplified Schematic, Power Connections . . . . . . 8

Supplied Manuals

The following manuals are shipped with the Reactor™ Proportioner. Refer to these manuals for detailed equip­ment information.
Order Part 15M334 for a compact disk of Reactor manu­als translated in several languages.
Manuals are also available at www.graco.com.
Reactor Hydraulic Proportioner
Detailed Schematic,
Motor Controls (1-Phase Motor) . . . . . . . . . . . 10
Detailed Schematic,
Motor Controls (3-Phase Motor) . . . . . . . . . . . 11
Detailed Schematic, Heater Controls . . . . . . . . . . 12
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 14
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 14
Part Description
312062 Reactor Hydraulic Proportioner, Oper-
ation Manual (English)
312063 Reactor Hydraulic Proportioner,
Repair-Parts Manual (English)
313539 Reactor H-VR Proportioner, Opera-
tion Manual (English)
313540 Reactor H-VR Proportioner,
Repair-Parts Manual (English)
2 312064M

Models

H-25 SERIES
Models
Max Flow Full Load Peak Amps*
Part, Series
255400, F 69 230V (1) 15,960 8,000 22 (10) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 255401, F 46 230V (3) 15,960 8,000 22 (10) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 255402, F 35 400V (3) 15,960 8,000 22 (10) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 255406, F 100 230V (1) 23,260 15,300 22 (10) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 255407, F 59 230V (3) 23,260 15,300 22 (10) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 255408, F 35 400V (3) 23,260 15,300 22 (10) 0.063 (0.24) 1.91:1 2000 (13.8, 138)
Per Phase
Volt age (phase)
System Watts†
Primary Heater Watts
Rate
lb/min
(kg/min)
Approximate Output per Cycle (A+B) gal. (liter)
Hydraulic Pressure Ratio
Maximum Fluid Working Pressure psi (MPa, bar)
H-40 SERIES
Max Flow
Full Load
Part, Series
253400, E 100 230V (1) 23,100 12,000 45 (20) 0.063 (0.24) 1.91:1 2000 (13.8, 138)
253401, E 71 230V (3) 26,600 15,300 45 (20) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 253402, E 41 400V (3) 26,600 15,300 45 (20) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 253407, E 95 230V (3) 31,700 20,400 45 (20) 0.063 (0.24) 1.91:1 2000 (13.8, 138) 253408, E 52 400V (3) 31,700 20,400 45 (20) 0.063 (0.24) 1.91:1 2000 (13.8, 138)
Peak Amps* Per Phase
Voltage (phase)
System Watts†
Primary Heater Watts
Rate lb/min (kg/min)
Approximate Output per Cycle (A+B) gal. (liter)
Hydraulic Pressure Ratio
Maximum Fluid Working Pressure psi (MPa, bar)
H-50 SERIES
Max Flow
Full Load
Part, Series
253725, E 100 230V (1) 23,100 12,000 52 (24) 0.073 (0.28) 1.64:1 1700 (11.7, 117)
253726, E 71 230V (3) 26,600 15,300 52 (24) 0.073 (0.28) 1.64:1 2000 (13.8, 138) 253727, E 41 400V (3) 26,600 15,300 52 (24) 0.073 (0.28) 1.64:1 2000 (13.8, 138) 256505, E 95 230V (3) 31,700 20,400 52 (24) 0.073 (0.28) 1.64:1 2000 (13.8, 138) 256506, E 52 400V (3) 31,700 20,400 52 (24) 0.073 (0.28) 1.64:1 2000 (13.8, 138)
Peak Amps* Per Phase
Voltage (phase)
System Watts†
Primary Heater Watts
Rate lb/min (kg/min)
Approximate Output per Cycle (A+B) gal. (liter)
Hydraulic Pressure Ratio
Maximum Fluid Working Pressure psi (MPa, bar)
H-VR SERIES
Max Flow
Full Load
Part, Series
256886 71 230V (3) 26,600 15,300 15 (4) Variable Variable 3500 (24.1, 241) 256887 41 400V (3) 26,600 15,300 15 (4) Variable Variable 3500 (24.1, 241)
Peak Amps* Per Phase
Voltage (phase)
System Watts†
Primary Heater Watts
Rate lb/min (kg/min)
Approximate Output per Cycle (A+B) gal. (liter)
Hydraulic Pressure Ratio
Maximum Fluid Working Pressure psi (MPa, bar)
312064M 3
Models
H-XP2 SERIES
Approximate Full Load Peak Amps*
Part, Series
255403, F 100 230V (1) 23,260 15,300 1.5 (5.7) 0.042 (0.16) 2.79:1 3500 (24.1, 241) 255404, F 59 230V (3) 23,260 15,300 1.5 (5.7) 0.042 (0.16) 2.79:1 3500 (24.1, 241) 255405, F 35 400V (3) 23,260 15,300 1.5 (5.7) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
Per Phase
Volt age (phase)
System Watts†
Primary Heater Watts
Max Flow Rate gpm (lpm)
Output per
Cycle (A+B)
gal. (liter)
Hydraulic Pressure Ratio
Maximum Fluid Working Pressure psi (MPa, bar)
H-XP3 SERIES
Approximate
Full Load
Part, Series
253403, E 100 230V (1) 23,100 12,000 2.8 (10.6) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
253404, E 95 230V (3) 31,700 20,400 2.8 (10.6) 0.042 (0.16) 2.79:1 3500 (24.1, 241) 253405, E 52 400V (3) 31,700 20,400 2.8 (10.6) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
Peak Amps* Per Phase
Volt age (phase)
System Watts†
Primary Heater Watts
Max Flow Rate gpm (lpm)
Output per Cycle (A+B) gal. (liter)
Hydraulic Pressure Ratio
Maximum Fluid Working Pressure psi (MPa, bar)
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix
chamber sizes may be less.
Total system watts, based on maximum hose length for each unit:
Parts 255400 through 255408, 310 ft (94.6 m) maximum heated hose length, including whip hose.
Parts 253400 through 253408, 253725 through 253727, 256505, and 256506, 410 ft (125 m) maximum heated hose length, including whip hose.
Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum
flow.
CE approval does not apply.
4 312064M

Simplified Schematic, Motor Controls

1-Phase Motor

Simplified Schematic, Motor Controls
or H-50
312064M 5
Loading...