Graco 311493E User Manual

Instructions
Direct Immersion Kit 287843 for GH833, 733ES, 833ES, 933, 933ES, 5040ES
- For installation of tower/bracket -
IMPORTANT SAFETY INSTRUCTIONS
Read all warnings and instructions in this manual. Save these instructions.
GH833 Models: Refer to operation manual below. Before attempting to install kit, follow Pressure Relief Procedure
311279
311283
311484
Refer to operation manual below. Before attempting to install kit, follow Pressure Relief Procedure
311493E
EN
332156
332157
332158
ti7595b

Fixed Mounting (optional)

To prevent damaging the unit when transporting it in a truck or on a trailer, Graco recommends fixed mounting to the vehicle.
Repositioning Handle
Before you can secure the unit to a truck or trailer bed, you must reposition the handle.
1. Remove four handle sleeve screws.
ti7649b
2. Pull handle out of upper frame handle tubes and remove.
4. Insert plugs in upper frame handle tubes.
upper frame handle tubes
plugs
ti7744b
5. Insert handle into lower frame tubes. Face hose bracket down. Adjust to appropriate in/out location.
handle
handle
upper frame handle tubes
ti7651b
3. Remove two frame tube plugs located behind wheels.
lower frame tubes
ti7653b
6. Install four sleeve screws in lower frame tubes.
ti7652b
ti7650b
2 311493E
plugs
Securing Unit to Vehicle Bed
For fixed mounting, fasten U-bolts over sprayer frame as indicated in the following illustration.
Sprayer is a heavy piece of equipment. To avoid bodily injury that could result from equipment moving when transporting, secure sprayer to vehicle.
1. Reposition handle, steps 1-5, page 2.
2. Place U-bolts over sprayer frame and through holes in vehicle bed. Place a washer and nut over bolt end. Tighten nut securely.
Reposition Handle
U-bolts
U-bolts
311493E 3
Kit.jpg

General Information

Pressure Relief Procedure
1. Engage trigger lock.
2. Set pump valve OFF.
3. Turn engine OFF.
4. Turn pressure to lowest setting.
5. Trigger gun to relieve pressure.
6. Turn Prime valve down.
Trigger Lock
Engage trigger lock when you stop spraying to prevent gun from being accidentally triggered by hand or if dropped or bumped.
4 311493E

Removing Hydraulic Head and Pump

5. Remove four mounting bolts on pump assembly and set assembly out of the way.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.
1. Follow Pressure Relief Procedure, page 4.
2. Allow unit to cool.
3. Remove two hydraulic lines from head and body.
hydraulic lines
ti20953a
pump assembly
bolts
ti7598a
4. Remove suction set from pump.
ti20975a
6. Remove two black plugs. NOTE: Protect open hydraulic ports from debris and contamination.
plugs
pump
ti20955a
suction
set
hydraulic ports
ti7599a
311493E 5