Graco 309398A User Manual

g
Instructions
B
Software Upgrade Kit 245248
For upgrading ProDispense main PCB board software
309398
Rev. A
First choice when
quality counts™
To avoid damage, keep main PCB chip in its original packaging until you are ready to use it. Ground yourself with the wrist strap before han­dling circuit board components.
Kit includes:
Description Qty.
Main PCB Chip with software update 1 Chip Extractor Tool 1 Grounding Wrist Strap 1
Replacing Main PCB Chip
To reduce the risk of fire, explosion or elec­tric shock:
ProDispense controller must only be
installed and serviced by a qualified electrician. Turn off ProDispense power switch and
disconnect electrical power supply before servicing equipment.
1. Turn off ProDispense power switch.
5. Orient the new chip with the main PCB socket and lay it on the socket. With even pressure, snap the chip firmly into place. When properly installed, the top of the chip is flush with the top of the socket.
6. Reinstall control box cover.
2. Remove control box cover (A). See Manual 309301 and refer to
3. Locate PCB chip (B) on main circuit board. See
.
1
4. Remove old chip (B) with chip extractor provided.
The chip has three sharp corners and one chamfered corner. Orient the chips chamfered corner toward the sockets chamfered corner. Incorrect installation can damage the chip or board.
.
. 2
F
IG
F
IG
COPYRIGHT 2001, Graco Inc.
Graco Inc. is re
istered to I.S. EN ISO 9001
FIG. 1
.
FIG. 2
A
REF B
TI1436a
Sales Offices:
International Offices:
Minneapolis, Detroit
Belgium, Korea, Hong Kong, Japan
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
www.graco.com
PRINTED IN USA 309398 July 2001