Graco 309004C User Manual

Instructions/Parts List

CycleFlo II

309004C

Pneumatic Pump Controller

Controls pump speed for precise batching, metering, and dosing of fluids at high or low pressures and flow rates.
Not for use in explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
ENG
120 psi (0.8 MPa, 8 bar) Maximum Air Working Pressure
Integrated Air Valves with Silenced Exhaust
Infinite Cycle Rate Adjustment Between 10 and 200 cpm
Standard 120 VAC Power
Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pneumatic Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Setup & Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cycles Per Minute (CPM) Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3
5
5
8
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Priming the Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Remote Operation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
T
roubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Installation Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Hole Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
9
10
11
12
13
14
14
2 309004

Warning Symbol Caution Symbol

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
Equipment Misuse Hazard
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are uncertain about usage, call
your Graco distributor.
Other than for installation purposes do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure of the lowest rated system component.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do
not expose Graco hoses to temperatures above 200 F (93 C) or below 0 F (-18 C).
Do not lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical and safety
regulations.
3 309004
Fire, Explosion, and Electric Shock Hazard
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and resulting fire or explosion and serious injury.
Ground the equipment.
Proper grounding dissipates static electricity generated in the equipment.
This equipment is not intended for intrinsically safe areas.
Keep the dispense area free of debris, including solvent, rags, and gasoline.
If there is any static sparking or you feel an electric shock while using the equipment,
stop operating immediately. Do not use the equipment until you have identified and corrected the problem.
Make sure all electrical work is performed only by a qualified electrician.
Have any checks, installation or service to electrical equipment performed by a
qualified electrician only.
Make sure all electrical equipment is installed and operated in compliance with local and applicable codes.
Make sure power is disconnected when servicing and repairing equipment.
Keep liquids away from the electrical components.
Disconnect electrical power at the main switch before servicing the equipment.
Never exceed maximum wattage of the supply unit.
4 309004

General Description

The CycleFlo II is a pneumatic pump controller that allows precise control over the cycle rate of the pump and therefor the flow rate.
The pump cycle is initiated by a 120 volt signal. The pump cycle may be initiated by some other piece of equipment such as a timer or a pH controller. An isolation relay may be required in some installations. Always follow local and applicable electrical codes. The CycleFlo II will halt the pump cycle whenever the 120 volt signal is removed.
Installation
Electrical Connections
An access hole with a strain relief installed has been provided for the external power connection. Due to the unique requirements of each installation, access holes have not been provided for the other optional external wiring
connections such as the external air supply
Fire, Explosion, and Electric Shock Hazard
To reduce the risk of fire, explosion, or electric shock:
The power source conduit is not an adequate grounding for the system. The unit must be grounded to a true earth ground.
A qualified electrician must complete all grounding and wiring connections and check the resistance.
Refer to your local code for the requirements for a “true earth ground” in your area.
valve signal. Have a qualified electrician determine the proper strain relief, wire type, and wire size for your particular application. When positioning or adding access holes, be careful not to damage any internal components. Failure to use the proper strain relief, wire type and wire size can cause damage to internal components or personal injury.
There are three connections on the 120V input signal terminal block (see Fig. 1). The two right­hand connections are for line and neutral wires respectively. The left-hand connection is for a true earth ground.
5 309004