This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
This symbol alerts you to the possibility of damage
to or destruction of equipment if you do not follow
the instructions.
Equipment Misuse Hazard
Equipment misuse can cause the equipment to rupture or malfunction and result in serious
injury.
• This equipment is for professional use only.
• Read all instruction manuals, tags, and labels before operating the equipment.
• Use the equipment only for its intended purpose. If you are uncertain about usage, call
your Graco distributor.
• Other than for installation purposes do not alter or modify this equipment. Use only
genuine Graco parts and accessories.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Do not exceed the maximum working pressure of the lowest rated system component.
• Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do
not expose Graco hoses to temperatures above 200 F (93 C) or below 0 F (-18 C).
• Do not lift pressurized equipment.
• Comply with all applicable local, state, and national fire, electrical and safety
regulations.
3 309004
Fire, Explosion, and Electric Shock Hazard
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous
condition and resulting fire or explosion and serious injury.
• Ground the equipment.
• Proper grounding dissipates static electricity generated in the equipment.
• This equipment is not intended for intrinsically safe areas.
• Keep the dispense area free of debris, including solvent, rags, and gasoline.
• If there is any static sparking or you feel an electric shock while using the equipment,
stop operating immediately. Do not use the equipment until you have identified and
corrected the problem.
• Make sure all electrical work is performed only by a qualified electrician.
• Have any checks, installation or service to electrical equipment performed by a
qualified electrician only.
• Make sure all electrical equipment is installed and operated in compliance with local
and applicable codes.
• Make sure power is disconnected when servicing and repairing equipment.
• Keep liquids away from the electrical components.
• Disconnect electrical power at the main switch before servicing the equipment.
• Never exceed maximum wattage of the supply unit.
4 309004
General Description
The CycleFlo II is a pneumatic pump controller that allows precise control over the cycle rate of the pump and
therefor the flow rate.
The pump cycle is initiated by a 120 volt signal. The pump cycle may be initiated by some other piece of equipment
such as a timer or a pH controller. An isolation relay may be required in some installations. Always follow local and
applicable electrical codes. The CycleFlo II will halt the pump cycle whenever the 120 volt signal is removed.
Installation
Electrical Connections
An access hole with a strain relief installed has been provided for the external power connection. Due to the unique
requirements of each installation, access holes have not been provided for the other optional external wiring
connections such as the external air supply
Fire, Explosion, and Electric Shock
Hazard
To reduce the risk of fire, explosion, or electric
shock:
• The power source conduit is not an
adequate grounding for the system. The
unit must be grounded to a true earth
ground.
• A qualified electrician must complete all
grounding and wiring connections and
check the resistance.
• Refer to your local code for the
requirements for a “true earth ground” in
your area.
valve signal. Have a qualified electrician
determine the proper strain relief, wire type, and
wire size for your particular application. When
positioning or adding access holes, be careful
not to damage any internal components. Failure
to use the proper strain relief, wire type and wire
size can cause damage to internal components
or personal injury.
There are three connections on the 120V input
signal terminal block (see Fig. 1). The two righthand connections are for line and neutral wires
respectively. The left-hand connection is for a
true earth ground.
5 309004