Model PRO 3500sc Electrostatic Air Spray Gun
65 kV, MANUAL GUN
100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
Part No. 222300, Series B
With Two-Finger Trigger
Part No. 222600, Series B
With Four-Finger Trigger
Rev. AC
Part No. 222300 shown
NOTE: Any modification of genuine Graco parts or replacement of parts with non-Graco parts will void agency approvals. U.S. PATENT NO. 4,290,091; 4,219,865; 4,497,447; 4,462,061; 4,660,774 ; D313,064; 4,978,075
Patented 1986, 1987 Canada Brevete 1986, 1987 U.K. PATENT NO. 2,147,158; 2,142,559B; 2,140,327B French Patent No. 89 16305 Other U.S. and Foreign Patents Pending
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
COPYRIGHT 1989, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
06443
Table of Contents
Symbols 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How the Electrostatic Air Spray Gun Works 5. . . .
Installation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the System 5. . . . . . . . . . . . . . . . . . . . . . . .
Warning Signs 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ventilate the Spray Booth 5. . . . . . . . . . . . . . . . . . . .
Non-hazardous Area 6. . . . . . . . . . . . . . . . . . . . . . . .
Hazardous Area 6. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect the Air Line 7. . . . . . . . . . . . . . . . . . . . . . . .
Connect the Exhaust Tube 7. . . . . . . . . . . . . . . . . . .
Connect the Fluid Line 7. . . . . . . . . . . . . . . . . . . . . . .
Ground the System 8. . . . . . . . . . . . . . . . . . . . . . . . .
Check the Electrical Grounding 9. . . . . . . . . . . . . . .
Operation 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Relief Procedure 11. . . . . . . . . . . . . . . . . .
Filter the Fluid 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Checklist 11. . . . . . . . . . . . . . . . . . . . . . . .
Selecting a Fluid Nozzle and Air Cap 12. . . . . . . . .
Operating the Spray Gun 12. . . . . . . . . . . . . . . . . . .
Shutdown 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prepare the Gun for Service 22. . . . . . . . . . . . . . . . . . . .
Air Cap/Nozzle/Resistor Stud Replacement 22. . . . . .
Electrode Replacement 23. . . . . . . . . . . . . . . . . . . . . . . .
Barrel Removal 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Packing Removal 25. . . . . . . . . . . . . . . . . . . . . . . .
Fluid Packing and Needle Repair 26. . . . . . . . . . . . . . . .
Power Cartridge Replacement 27. . . . . . . . . . . . . . . . . .
Turbine Alternator Replacement 28. . . . . . . . . . . . . . . .
Barrel Installation 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Air Adjustment Valve Repair 29. . . . . . . . . . . . . . . .
Fluid Adjustment Assembly Repair 30. . . . . . . . . . . . . . .
Air Trigger Valve Repair 31. . . . . . . . . . . . . . . . . . . . . . . .
Atomizing Air Valve Removal and Replacement 31. . .
ES ON-OFF Valve Repair 32. . . . . . . . . . . . . . . . . . . . . .
Parts 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Graco Warranty and Disclaimers 40. . . . . . . . . .
Graco Phone Number 40. . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Daily Care and Cleaning 14. . . . . . . . . . . . . . . . . . . .
Clean the Air Cap and Fluid Nozzle 15. . . . . . . . . .
Flush the Spray Gun 15. . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spray Pattern Troubleshooting 16. . . . . . . . . . . . . . .
Gun Operation Troubleshooting 17. . . . . . . . . . . . . .
Electrical Troubleshooting 18. . . . . . . . . . . . . . . . . . .
Electrical Tests 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Gun Resistance 19. . . . . . . . . . . . . . . . . . . . . . .
Test Power Supply Resistance 20. . . . . . . . . . . . . . .
Test Resistor Stud Resistance 20. . . . . . . . . . . . . . .
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.
2 307912
WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in a fire, explosion, or electric shock.
Electrostatic equipment must be used only by trained, qualified personnel who understand the
requirements stated in this instruction manual.
Ground the equipment, personnel in or close to the spray area, the object being sprayed, and all
other electrically conductive objects in the spray area. See Ground the System on page 8.
Check the spray gun resistance daily. See Test Gun Resistance, page 19.If there is any static sparking while using the equipment, stop spraying immediately. Identify and
correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable or toxic vapors. Interlock the gun
turbine air supply to prevent operation of the power supply unless the ventilating fans are on. See Ventilate the Spray Booth on page 5.
When cleaning, flushing, or purging electrostatic equipment, use solvents that comply with your
local regulations. For countries following the U.S. National Fire Protection Association (NFPA) 33 requirements, use solvents with a flash point higher than 100 F (38 C) or a solvent normally used in spray operations. For European Countries complying with EN 50053, use solvents with a flash point as high as possible and higher than the ambient temperatures.
Use only non-sparking tools to clean residue from the booth and hangers.Do not flush the system with the gun electrostatics turned on.Do not turn on the gun electrostatics until all solvent is removed from the system.Extinguish all open flames or pilot lights in the spray area.Keep the spray area free of debris, including solvent, rags, and gasoline.Do not store any flammable fluids in the spray area.Do not turn on or off any light switch in the spray area while operating or if fumes are present.Do not smoke in the spray area.Do not operate a gasoline engine in the spray area.
TOXIC FLUID HAZARD
Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled.
Know the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.Store hazardous fluid in an approved container. Dispose of the hazardous fluid according to all
local, state, and national guidelines.
Wear appropriate protective clothing, gloves, eyewear, and respirator.
Warnings are continued on the next page.
307912 3
WARNING
PRESSURIZED EQUIPMENT HAZARD
Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause a serious injury.
Do not point the spray gun at anyone or any part of the body.Do not stop or deflect fluid leaks with your hand, body, glove, or rag.Follow the Pressure Relief Procedure on page 11 whenever you: are instructed to relieve the
pressure; stop spraying; clean, check, or servicing the equipment; and install or clean the fluid nozzles.
Tighten all the fluid connections before operating the equipment.Check the hoses, tubes and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.
EQUIPMENT MISUSE HAZARD
INSTRUCTIONS
Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury.
This equipment is for professional use only.Read all the instruction manuals, tags, and labels before operating the equipment.Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
Do not alter or modify this equipment. Use only genuine Graco parts and accessories.Check the equipment daily. Repair or replace worn or damaged parts immediately.Do not exceed the maximum working pressure of the lowest rated system component. This equip-
ment has a 100 psi (7 bar, 0.7 MPa) maximum working air and fluid pressure.
Use fluids that are compatible with the equipment wetted parts. See the Technical Data section of
all the equipment manuals. Read the fluid manufacturers warnings.
Route the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not
expose Graco hoses to temperatures above 180F (82C) or below –40F (–40C).
Do not use the hoses to pull equipment.Wear hearing protection when operating this equipment.Comply with all applicable local, state, and national fire, electrical, and other safety regulations.
4 307912
Introduction
How the Electrostatic Air Spray Gun Works
The air hose supplies air to the spray gun. Part of the air operates the turbine and the rest of the air atomizes the fluid being sprayed. The turbine generates power, which is converted by the power cartridge, to supply high voltage current to the gun’s ionizing electrode.
Installation
Installing the System
WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD
Installing and servicing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly.
Do not install or service this equip-
ment unless you are trained and qualified.
Be sure your installation complies with National,
State and Local codes for the installation of electrical apparatus in a Class I, Group D Hazardous Location.
The pump supplies fluid to the hose and gun, where the fluid is electrostatically charged as it passes the electrode. The charged fluid is attracted to the grounded workpiece, wrapping around and evenly coating all surfaces.
Warning Signs
Mount warning signs in the spray area where they can easily be seen and read by all operators. An English Warning Sign is provided with the gun. Additional English, French, German, and Spanish signs are available at no charge. See Accessories to order them.
Ventilate the Spray Booth
WARNING
FLAMMABLE OR TOXIC VAPOR HAZARD
Provide fresh air ventilation to avoid the buildup of flammable or toxic vapors. Do not operate the gun unless ventilation fans are operating.
Comply with all applicable local, state, and
national fire, electrical, and other safety regula­tions.
Fig. 1 shows a typical electrostatic air spray system. It is not an actual system design. The particular type and size system for your operation must be custom designed for your needs. For assistance in designing a system, contact your Graco distributor.
Electrically interlock the gun air supply with the ventila­tors to prevent gun operation without ventilating fans operating. Check and follow all National, State, and Local codes regarding air exhaust velocity requirements.
NOTE: High velocity air exhaust will decrease the operating efficiency of the electrostatic system. Air exhaust velocity of 100 ft/min (31 linear meters/minute) should be sufficient.
307912 5
KEY A Main Air Supply Line
B* Ventilation Fan Interlock Solenoid Valve C* Main Air Supply Shutoff Valve (bleed-type) D Air & Water Separator E* Pump Air Supply Shutoff V alve (bleed-type) F Air Line Lubricator G Air Pressure Regulator H Pump J* Pump Ground Wire K Fluid Filter L Fluid Supply Line Shutoff Valve M Fluid Pressure Regulator N Fluid Supply Line O Air Filter (20 micron)
Installation
P Air Supply Line Shutoff Valve Q* Air Hose Ground Wire R* Graco Electrically Conductive Air Hose S Electrostatic Spray Gun T Air Line Drain Valve U* Fluid Drain Valve V Gun Air Inlet W Gun Fluid Inlet X Gun Exhaust Tube
* Required for safe operation. Must purchase separately. See
Accessories. NOTE: Solenoid Valve (B) is not offered as a Graco accessory.
AM
ES ON-OFF Lever
1 is ON 0 is OFF
Fig. 1
N
B* C* D
E*
GF
O
H
J*
K L
U*
Non-hazardous Area Hazardous Area
The air supply to the gun must be electrically interlocked with the ventilators to prevent the power supply from operating without ventilating fans on.
S
V
G
X
W
P
R
WARNING
SIGN
Q*
T
0389
6 307912
Installation
Connect the Air Line (Refer to Fig. 1)
WARNING
ELECTRIC SHOCK HAZARD
To reduce the risk of an electric shock or other serious injury, the air supply hose must be electrically connected to a true
earth ground. Use Only Graco Electrically Con-
ductive Air Supply Hose.
1. Connect the Graco Electrically Conductive Air Supply Hose (R) between the air supply line and the gun’s air inlet (V). The gun air inlet fitting has a left hand thread. Connect the air supply hose ground wire to a true earth ground.
2. Install an air line filter (O) and an air and water separator (D) on the air line to ensure a dry, clean air supply to the gun. Dirt and moisture can ruin the appearance of your finished workpiece and can cause the gun to malfunction.
3. Install a bleed-type air regulator (G) on the pump and gun air supply lines to control air pressure to the pump and gun.
4. Install a bleed-type air shutoff valve on the main air line (C) and the pump air line (E) to shut off air to the pump. Install an additional bleed-type valve on each pump air supply line to relieve air trapped between this valve and the pump after the air regulator is shut off.
5. Install an air line lubricator (F) as close to the pump (H) as possible.
6. Install an air shutoff valve (P) on each gun air supply line to shut off air to the gun(s).
Connect the Exhaust Tube
Press the exhaust tube (provided) onto the barbed adapter on the bottom of the gun handle. Secure the tube with the clamp provided. Refer to page 34.
Connect the Fluid Line (Refer to Fig. 1)
1. Before connecting the fluid line (N), blow it out with air and flush it with solvent. Use solvent which is compatible with the fluid to be sprayed.
2. Install a fluid regulator (M) on the fluid line to control fluid pressure to the gun.
3. Install a fluid filter (K) and drain valve (U) at the pump outlet.
WARNING
PRESSURIZED EQUIPMENT HAZARD
The fluid drain valve (U) is required in your system to assist in relieving fluid pressure in the displace­ment pump, hose and gun; triggering the gun to relieve pressure may not be sufficient. Install a drain valve close to the pumps fluid outlet. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin.
WARNING
PRESSURIZED EQUIPMENT HAZARD
The bleed-type air shutoff valve is required in your system to relieve air trapped between this valve and the pump after the air regulator is closed. Trapped air can cause the pump to cycle unexpect­edly, which could result in serious injury, including splashing in the eyes or on the skin.
4. Connect the fluid line to the 3/8–18.6(m) gun fluid inlet (W).
5. Before running any paint through the spray gun, flush it out with a compatible solvent.
307912 7
Installation
Ground the System
WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD
When operating the electrostatic device, any ungrounded objects in the spray area (such as people, containers, tools, etc.) can become electrically charged. Improper grounding can result in static sparking, which can cause a fire, explo­sion, or electric shock. Follow the grounding instructions below.
The following are minimum grounding requirements for a basic electrostatic system. Your system may include other equipment or objects which must be grounded. Check your local electrical code for detailed grounding instructions. Your system must be connected to a true earth ground.
1. Pump: ground the pump by connecting a ground wire and clamp as described in your separate pump instruction manual.
2. Air compressors and hydraulic power supplies: ground the equipment according to the manufac­turers recommendations.
3. Electrostatic Air Spray Gun: ground the gun by connecting the Graco Electrically Conductive Air Hose and connecting the air hose ground wire to a true earth ground. Check the electrical grounding of the gun as instructed on page 9.
4. All air and fluid lines must be properly grounded. Use only grounded hoses with a maximum of 500 feet (150 m) combined hose length to ensure grounding continuity.
5. All electric cables must be properly grounded.
6. All persons entering the spray area: their shoes must have conductive soles, such as leather, or personal grounding straps must be worn. Rubber or plastic soles are not conductive. The operator must not wear gloves that insulate the hand from the spray gun. The gloves must be conductive or modified as shown in Fig. 3, page 11.
7. Object being sprayed: keep the workpiece hangers clean and grounded at all times. Contact points must be sharp points or like knife edges.
8. The floor of the spray area: must be electrically conductive and grounded. Do not cover the floor with cardboard or any non-conductive material which would interrupt grounding continuity.
9. Flammable liquids in the spray area: must be kept in approved, grounded containers. Do not store more than the quantity needed for one shift.
10. All electrically conductive objects or devices in the spray area: including fluid containers and wash cans, must be properly grounded.
8 307912
Installation
Check the Electrical Grounding (See Fig. 2)
WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD
Megohmmeter P/N 241079 (AA-see Fig.
2) is not approved for use in a hazard­ous area. To reduce the risk of sparking, do not use the megohmmeter to check electrical grounding unless:
The gun has been removed from the
hazardous area;
Or all spraying devices in the hazardous area
are turned off, ventilation fans in the hazardous area are operating, and there are no flammable vapors in the area (such as open solvent con­tainers or fumes from spraying).
Failure to follow this warning could cause fire, explosion, electric shock and result in serious injury and property damage.
b. If using a red turbine air hose, use an ohmme-
ter to measure the resistance. Resistance should not exceed 100 ohms.
6. If the resistance is greater than the maximum reading specified above for your hose, check the tightness of the ground connections and be sure the air hose ground wire is connected to a true earth ground. If the resistance is still too high, replace the air hose.
R
BB
1. Have a qualified electrician check the electrical grounding continuity of the spray gun and air hose.
2. Turn the ES ON-OFF Lever to OFF. See Fig. 4, page 12, for the location of the lever.
3. Turn off the air and fluid supply to the gun. The fluid hose must not have any fluid in it.
4. Make sure the air hose (R) is connected and the hose ground wire is connected to a true earth ground.
5. Measure the resistance between the gun handle (BB) and a true earth ground (CC).
a. If using a black or grey air hose, use a me-
gohmmeter (AA) to measure the resistance. Use an applied voltage of 500 minimum to 1000 volts maximum. The resistance should not exceed 2 megohms.
AA
CC
0644B
Fig. 2
307912 9
Notes
10 307912
Operation
Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT HAZARD
The system pressure must be manually relieved to prevent the system from starting or spraying acci­dentally. To reduce the risk of an injury from electric shock, accidental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:
are instructed to relieve the pressure,stop spraying,check or service any of the system equipment,or install or clean the fluid nozzle.
1. Turn the ES ON–OFF Lever to OFF.
2. Turn off the air and fluid supply to the gun.
3. Trigger the gun into a grounded metal waste container to relieve fluid pressure.
4. Open the pump drain valve, having a waste con­tainer ready to catch the drainage.
5. Leave the pump drain valve open until you are ready to spray again.
Filter the Fluid
Operating Checklist
Check the following list daily, before starting to operate the system, to help ensure safe, efficient operation.
____ 1. All the operators are properly trained to
safely operate an electrostatic air spray system as instructed in this manual.
____ 2. All the operators are trained how to properly
relieve pressure as instructed at left.
____ 3. The system is thoroughly grounded and the
operator and all persons entering the spray area are properly grounded. See Ground the System, page 8.
____ 4. The operator is not wearing gloves which
insulate the hand from the spray gun. If worn, gloves must be conductive or modified as shown in Fig. 3 so as not to interfere with the operator grounding through the gun.
____ 5. The condition of the electrical components of
the spray gun has been checked as
instructed in Electrical Tests, page 19. ____ 6. The ventilation fans are operating properly. ____ 7. The workpiece hangers are clean and
grounded. Contact points must be sharp
points or like knife edges.
Filter the fluid to remove coarse particles and sediment which could clog the spray nozzle.
3 in. (76 mm) square cut out and finger of glove cut off
NOTE: If gloves are worn, they must be conductive or modified as shown so they do not interfere with operator grounding through the gun.
Fig. 3
06445
____ 8. All the debris, including flammable liquids
and rags, is removed from the spray area. ____ 9. All flammable liquids in the spray booth are
in approved, grounded containers. ____ 10. All conductive objects in the spray area are
electrically grounded and the floor of the
spray area is electrically conductive and
grounded.
307912 11
Operation
DD
31
20
1
06443
Fig. 4
Selecting a Fluid Nozzle and Air Cap
WARNING
PRESSURIZED EQUIPMENT HAZARD To reduce the risk of an injury, follow the Pressure Relief Procedure on page 11 before removing or
installing a fluid nozzle and/or air cap.
The gun is supplied with a 0.059 in. (1.5 mm) fluid nozzle, P/N 185158, and air cap, P/N 193033. If your application requires a different nozzle and air cap combination, use instruction manual 307803 or consult your authorized Graco distributor to select the ap­propriate fluid nozzle and air cap. Install the air cap and fluid nozzle into the gun barrel as instructed in Air Cap/Nozzle/Resistor Stud Replacement, page 22.
26 43
45
05151A
Operating the Spray Gun
WARNING
PRESSURIZED EQUIPMENT HAZARD To reduce the risk of an injury, follow the Pressure Relief Procedure on page 11 whenever you stop
spraying and whenever you are instructed to relieve pressure.
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of component rupture, which can cause serious injury, do not
exceed the maximum working pressure of the lowest rated system component. This equip­ment has a 100 psi (7 bar, 0.7 MPa) maximum working air and fluid pressure.
12 307912
Follow the steps on page 13 to establish the correct fluid flow and air flow. Do not turn the ES ON-OFF lever to ON yet.