This manual covers the installation and operation of Graco Fire-Ball pumps. For information on service and repair of
these pumps, please see the following manual.
•Fire-Ball Pump Service, Troubleshooting, and Repair 309869.
You should also read the instruction manuals for all components of your system.
2Installation and Operation
Packages
Packages
Model/
Package No.PumpDescription
Fire-Ball 225 Packages
248230
246903
246904
246906
246907
Fire-Ball 300 Packages
225852
225728
225094
225642
225640
225931
222086
206655
204264
246775Universal
248097
24809716 gallon (60 liter), drum
24809755 gallon (208 liter), drum
24809755/275 gallon (208/1041 liter),
203876
203872
20387216 gallon (60 liter), drum
20385755 gallon (208 liter), drum
20425455 gallon (208 liter), bung
222087275 gallon (1041 liter)
20387216 gallon (60 liter), drum
20385755 gallon (208 liter) drum
20425455 gallon (208 liter) bung
16 gallon (60 liter), gear lube204574237075224512
cover222063204574224512
cover222063200326224512
bung mount222063222308
Universal222062
16 gallon (60 liter), gear lube204574237075224512
cover222063204574
cover222063200326
mount222063222308
obround tank222063222308
cover, truck mount222063222060
cover, truck mount222063207367
adapter, truck mount222063204076
Hose/
Fitting Kit
222062
Cover/Bung
Adapter
Dispense
Kit
Air
Regulator
Fire-Ball 425 Packages
225853
225782
225786
206656
222067
Installation and Operation3
205626
22206555 gallon drum (208 liter),
22209555 gallon (208 liter), bung
22206555 gallon (208 liter) drum
22209555 gallon (208 liter) bung
Universal222068
drum cover222066200326
adapter222066222308
cover, truck mount222066207367
adapter, truck mount222066224579
Manual Conventions
WarningCaution
Manual Conventions
WARNING
A warning alerts you to possible serious injury or
death if you do not follow instructions.
Symbols, such as fire and explosion (shown), alert you
to a specific hazard and direct you to read the indicated hazard warnings beginning on page 4.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in
all equipment manuals. Read fluid and solvent manufacturer’s warnings.
•Check equipment daily. Repair or replace worn or damaged parts immediately.
•Do not alter or modify equipment.
•Use equipment only for its intended purpose. Call your Graco distributor for information.
•For professional use only.
•Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•Do not use hoses to pull equipment.
•Comply with all applicable safety regulations.
CAUTION
A caution alerts you to possible equipment damage or
destruction if you do not follow instructions.
Note
A note indicates additional helpful information.
WARNINGS
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin
and cause serious injury.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
•Tighten all fluid connections before operating the equipment.
•Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
4Installation and Operation
Warning
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just
a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
•Do not point gun at anyone or at any part of the body.
•Do not put your hand over the spray tip.
•Do not stop or deflect leaks with your hand, body, glove, or rag.
•Do not spray without tip guard and trigger guard installed.
•Engage trigger lock when not spraying.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•Keep clear of moving parts.
•Do not operate equipment with protective guards or covers removed.
•Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•Read MSDS’s to know the specific hazards of the fluids you are using.
•Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•Keep work area free of debris, including solvent, rags and gasoline.
•Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
•Ground equipment and conductive objects. See Grounding instructions.
•Use only grounded hoses.
•Hold gun firmly to side of grounded pail when triggering into pail.
•If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
Installation and Operation5
Installation
The typical stationary installation shown in is only a
guide for selecting and installing a pump; it is not an
actual system design. Contact your Graco distributor for
assistance in designing a system to meet your needs.
.
F
A
C
L
D
Installation
Letters used to identify components in FIG. 1 are
referred to in the package installation drawings,
F
IG. 3 through FIG. 7. Additional letter references
are used in installation drawings as necessary.
E
J
N
H
P
Key
ABleed-type master air valve
BAir line filter
CAir regulator and gauge
DAir inlet
EGround wire
FPump
GDrain valve
M
B
G
K
HDispensing valve
JFluid hose
KThermal relief kit (235998)
LAir line lubricator
M Bung adapter
NFluid outlet
PExtension tube
FIG. 1
6Installation and Operation
Installation
Mounting the Pump
WARNING
Mount the pump securely so that it cannot move during operation. Failure to do so could result in personal
injury or equipment damage.
•Select a location that allows the operator easy
access to the pump and air controls, sufficient room
to change supply containers, and a secure mounting platform.
•If you are mounting the pump directly on the supply
container, be sure it is positioned so the pump’s
intake tube is no more than 1 in. (25 mm) from the
bottom of the container. Mount the pump to the
cover or other suitable mounting device.
To prevent damage to the pump, remove sediment from the bottom of the container before
installing a pump in an existing container.
Grounding
•To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
dispensing valve firmly to the side of a metal pail
and then open the dispensing valve.
To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the valve firmly
to the side of a grounded metal pail, then trigger the
valve.
To ground the pump, remove the ground screw (Z) and
insert through the eye of the ring terminal at end of
ground wire, (Y). Fasten the ground screw back onto the
pump and tighten securely. Connect the other end of the
ground wire to a true earth ground. See F
a ground wire and clamp order Part No. 222011.
Z
IG. 2. To order
Y
Proper grounding is essential to maintaining a safe system.
To reduce the risk of static sparking, ground the pump.
Check local electrical codes for detailed grounding
instructions for your area and equipment type. Be sure
the following equipment is properly grounded:
•Pump: See F
•Air and Fluid hoses: Use only electrically conductive
hoses.
•Dispensing valve: Obtain grounding through connection to a properly grounded fluid hose and pump.
•Fluid supply container: Follow your local code.
•Object being lubricated: Follow your local code.
•Any pails used when flushing: Use only metal,
grounded pails when flushing. Make firm
metal-to-metal contact between a metal part of the
dispensing valve and the pail. Use the lowest possible pressure.
IG. 2
F
TI1052
IG. 2
Installation and Operation7
Installation
Universal Pump
Fire-Ball 225 Model 248230
Fire-Ball 300 Model 225852
Fire-Ball 425 Model 225853
1. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the pump
air inlet (D).
F
D
2d
2. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
3. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
4. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
N
2b
2a
F
2c
IG. 3
8Installation and Operation
Installation
16-Gallon (60 Liter) Gear Lube Dispenser
Fire-Ball 225 Model 246903
Fire-Ball 300 Model 225728
1. Assemble the base (5) as shown in FIG. 4. Place an
opened 16-gallon (60 liter) drum on the base and
secure it with the hold-down clamps. Tighten the
hold-down clamp bolts
2. For 246903, cut the extension tube (P) at a 45°
angle to a length appropriate for the size of the
F
3b
D
3d
3d
R
N
drum. When installed, the bottom of the angle
should be about 1” (25 mm) from the bottom of the
drum. The down tube for 225728 is sized for the
container.
3. Set the cover (4) on the drum and secure the
thumbscrews (Q). Install the pump (F) on the cover
(4) with the screws (R), washers and nuts (S) provided
4. Connect the hose (2a) to the pump fluid outlet (N).
2a
2b
3a
4
3c
Q
P
5
S
F
IG. 4
Installation and Operation9
Installation
16-Gallon (60 Liter) Drum Cover Pump
Fire-Ball 225 Model 246904
Fire-Ball 300 Model 225094
1. Set the cover (4) on a 16-gallon (60 liter) drum and
secure with the thumbscrews (Q). See F
2. For 246904 cut the extension tube (P) at a 45° angle
to a length appropriate for the size of the drum.
When installed, the bottom of the angle should be
about 1” (25 mm) from the bottom of the drum. The
down tube for 225094 is sized for the container.
3. Install the pump (F) on the cover (4) with the screws
(R), washers and nuts (S) supplied.
IG. 5.
F
4. Assemble the air regulator kit (items 3a-3d) to the
pump air inlet (D) as shown. Use thread sealant and
tighten all parts securely.
5. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the
bleed-type master air valve (3c).
6. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
7. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
8. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
2d
2c
3c
3b
3d
Q
3d
D
A
3a
P
4
R
N
2b
2a
S
F
IG. 5
10Installation and Operation
Installation
55-Gallon (208 Liter) Drum Cover Pump
Fire-Ball 225 Model 246906
Fire-Ball 300 Model 225642
Fire-Ball 425 Model 225782
1. For 246906 cut the extension tube (P) at a 45° angle
to a length appropriate for the size of the drum.
When installed, the bottom of the angle should be
about 1” (25 mm) from the bottom of the drum. For
225642 and 225782 the down tube is sized for the
container.
2. Set the cover (4) on a 55-gallon (208 liter) drum.
Install the pump (F) on the cover with the screws (R)
supplied. See F
IG. 6
3b
3d
F
3d
D
3. Assemble the air regulator kit (items 3a-3d) to the
pump air inlet (D) as shown. Use thread sealant and
tighten all parts securely.
4. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the
bleed-type master air valve (3c).
5. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
6. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
7. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
R
N
2b
2c
3c
2a
2d
3a
4
P
F
IG. 6
Installation and Operation11
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.