This manual covers the installation and operation of Graco Fire-Ball pumps. For information on service and repair of
these pumps, please see the following manual.
•Fire-Ball Pump Service, Troubleshooting, and Repair 309869.
You should also read the instruction manuals for all components of your system.
2Installation and Operation
Page 3
Packages
Packages
Model/
Package No.PumpDescription
Fire-Ball 225 Packages
248230
246903
246904
246906
246907
Fire-Ball 300 Packages
225852
225728
225094
225642
225640
225931
222086
206655
204264
246775Universal
248097
24809716 gallon (60 liter), drum
24809755 gallon (208 liter), drum
24809755/275 gallon (208/1041 liter),
203876
203872
20387216 gallon (60 liter), drum
20385755 gallon (208 liter), drum
20425455 gallon (208 liter), bung
222087275 gallon (1041 liter)
20387216 gallon (60 liter), drum
20385755 gallon (208 liter) drum
20425455 gallon (208 liter) bung
16 gallon (60 liter), gear lube204574237075224512
cover222063204574224512
cover222063200326224512
bung mount222063222308
Universal222062
16 gallon (60 liter), gear lube204574237075224512
cover222063204574
cover222063200326
mount222063222308
obround tank222063222308
cover, truck mount222063222060
cover, truck mount222063207367
adapter, truck mount222063204076
Hose/
Fitting Kit
222062
Cover/Bung
Adapter
Dispense
Kit
Air
Regulator
Fire-Ball 425 Packages
225853
225782
225786
206656
222067
Installation and Operation3
205626
22206555 gallon drum (208 liter),
22209555 gallon (208 liter), bung
22206555 gallon (208 liter) drum
22209555 gallon (208 liter) bung
Universal222068
drum cover222066200326
adapter222066222308
cover, truck mount222066207367
adapter, truck mount222066224579
Page 4
Manual Conventions
WarningCaution
Manual Conventions
WARNING
A warning alerts you to possible serious injury or
death if you do not follow instructions.
Symbols, such as fire and explosion (shown), alert you
to a specific hazard and direct you to read the indicated hazard warnings beginning on page 4.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in
all equipment manuals. Read fluid and solvent manufacturer’s warnings.
•Check equipment daily. Repair or replace worn or damaged parts immediately.
•Do not alter or modify equipment.
•Use equipment only for its intended purpose. Call your Graco distributor for information.
•For professional use only.
•Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•Do not use hoses to pull equipment.
•Comply with all applicable safety regulations.
CAUTION
A caution alerts you to possible equipment damage or
destruction if you do not follow instructions.
Note
A note indicates additional helpful information.
WARNINGS
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin
and cause serious injury.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
•Tighten all fluid connections before operating the equipment.
•Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
4Installation and Operation
Page 5
Warning
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just
a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
•Do not point gun at anyone or at any part of the body.
•Do not put your hand over the spray tip.
•Do not stop or deflect leaks with your hand, body, glove, or rag.
•Do not spray without tip guard and trigger guard installed.
•Engage trigger lock when not spraying.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•Keep clear of moving parts.
•Do not operate equipment with protective guards or covers removed.
•Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•Read MSDS’s to know the specific hazards of the fluids you are using.
•Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•Keep work area free of debris, including solvent, rags and gasoline.
•Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
•Ground equipment and conductive objects. See Grounding instructions.
•Use only grounded hoses.
•Hold gun firmly to side of grounded pail when triggering into pail.
•If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
Installation and Operation5
Page 6
Installation
The typical stationary installation shown in is only a
guide for selecting and installing a pump; it is not an
actual system design. Contact your Graco distributor for
assistance in designing a system to meet your needs.
.
F
A
C
L
D
Installation
Letters used to identify components in FIG. 1 are
referred to in the package installation drawings,
F
IG. 3 through FIG. 7. Additional letter references
are used in installation drawings as necessary.
E
J
N
H
P
Key
ABleed-type master air valve
BAir line filter
CAir regulator and gauge
DAir inlet
EGround wire
FPump
GDrain valve
M
B
G
K
HDispensing valve
JFluid hose
KThermal relief kit (235998)
LAir line lubricator
M Bung adapter
NFluid outlet
PExtension tube
FIG. 1
6Installation and Operation
Page 7
Installation
Mounting the Pump
WARNING
Mount the pump securely so that it cannot move during operation. Failure to do so could result in personal
injury or equipment damage.
•Select a location that allows the operator easy
access to the pump and air controls, sufficient room
to change supply containers, and a secure mounting platform.
•If you are mounting the pump directly on the supply
container, be sure it is positioned so the pump’s
intake tube is no more than 1 in. (25 mm) from the
bottom of the container. Mount the pump to the
cover or other suitable mounting device.
To prevent damage to the pump, remove sediment from the bottom of the container before
installing a pump in an existing container.
Grounding
•To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
dispensing valve firmly to the side of a metal pail
and then open the dispensing valve.
To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the valve firmly
to the side of a grounded metal pail, then trigger the
valve.
To ground the pump, remove the ground screw (Z) and
insert through the eye of the ring terminal at end of
ground wire, (Y). Fasten the ground screw back onto the
pump and tighten securely. Connect the other end of the
ground wire to a true earth ground. See F
a ground wire and clamp order Part No. 222011.
Z
IG. 2. To order
Y
Proper grounding is essential to maintaining a safe system.
To reduce the risk of static sparking, ground the pump.
Check local electrical codes for detailed grounding
instructions for your area and equipment type. Be sure
the following equipment is properly grounded:
•Pump: See F
•Air and Fluid hoses: Use only electrically conductive
hoses.
•Dispensing valve: Obtain grounding through connection to a properly grounded fluid hose and pump.
•Fluid supply container: Follow your local code.
•Object being lubricated: Follow your local code.
•Any pails used when flushing: Use only metal,
grounded pails when flushing. Make firm
metal-to-metal contact between a metal part of the
dispensing valve and the pail. Use the lowest possible pressure.
IG. 2
F
TI1052
IG. 2
Installation and Operation7
Page 8
Installation
Universal Pump
Fire-Ball 225 Model 248230
Fire-Ball 300 Model 225852
Fire-Ball 425 Model 225853
1. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the pump
air inlet (D).
F
D
2d
2. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
3. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
4. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
N
2b
2a
F
2c
IG. 3
8Installation and Operation
Page 9
Installation
16-Gallon (60 Liter) Gear Lube Dispenser
Fire-Ball 225 Model 246903
Fire-Ball 300 Model 225728
1. Assemble the base (5) as shown in FIG. 4. Place an
opened 16-gallon (60 liter) drum on the base and
secure it with the hold-down clamps. Tighten the
hold-down clamp bolts
2. For 246903, cut the extension tube (P) at a 45°
angle to a length appropriate for the size of the
F
3b
D
3d
3d
R
N
drum. When installed, the bottom of the angle
should be about 1” (25 mm) from the bottom of the
drum. The down tube for 225728 is sized for the
container.
3. Set the cover (4) on the drum and secure the
thumbscrews (Q). Install the pump (F) on the cover
(4) with the screws (R), washers and nuts (S) provided
4. Connect the hose (2a) to the pump fluid outlet (N).
2a
2b
3a
4
3c
Q
P
5
S
F
IG. 4
Installation and Operation9
Page 10
Installation
16-Gallon (60 Liter) Drum Cover Pump
Fire-Ball 225 Model 246904
Fire-Ball 300 Model 225094
1. Set the cover (4) on a 16-gallon (60 liter) drum and
secure with the thumbscrews (Q). See F
2. For 246904 cut the extension tube (P) at a 45° angle
to a length appropriate for the size of the drum.
When installed, the bottom of the angle should be
about 1” (25 mm) from the bottom of the drum. The
down tube for 225094 is sized for the container.
3. Install the pump (F) on the cover (4) with the screws
(R), washers and nuts (S) supplied.
IG. 5.
F
4. Assemble the air regulator kit (items 3a-3d) to the
pump air inlet (D) as shown. Use thread sealant and
tighten all parts securely.
5. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the
bleed-type master air valve (3c).
6. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
7. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
8. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
2d
2c
3c
3b
3d
Q
3d
D
A
3a
P
4
R
N
2b
2a
S
F
IG. 5
10Installation and Operation
Page 11
Installation
55-Gallon (208 Liter) Drum Cover Pump
Fire-Ball 225 Model 246906
Fire-Ball 300 Model 225642
Fire-Ball 425 Model 225782
1. For 246906 cut the extension tube (P) at a 45° angle
to a length appropriate for the size of the drum.
When installed, the bottom of the angle should be
about 1” (25 mm) from the bottom of the drum. For
225642 and 225782 the down tube is sized for the
container.
2. Set the cover (4) on a 55-gallon (208 liter) drum.
Install the pump (F) on the cover with the screws (R)
supplied. See F
IG. 6
3b
3d
F
3d
D
3. Assemble the air regulator kit (items 3a-3d) to the
pump air inlet (D) as shown. Use thread sealant and
tighten all parts securely.
4. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the
bleed-type master air valve (3c).
5. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
6. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
7. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
R
N
2b
2c
3c
2a
2d
3a
4
P
F
IG. 6
Installation and Operation11
Page 12
Installation
55-/275-Gallon (208 Liter) Drum,
Bung-Mount Pump
Fire-Ball 225 Model 246907
Fire-Ball 300 Models 225640 and 225931
1. Screw the bung adapter (M) into the bung hole of
the drum. See F
2. For 246907 cut the extension tube (P) at a 45° angle
to a length appropriate for the size of the drum.
When installed, the bottom of the angle should be
about 1” (25 mm) from the bottom of the drum. For
224640 and 225931 the down tube is sized for the
container.
2d
IG. 7.
F
N
D
3. Tighten the bung adapter screw (T) to hold the
pump in position.
4. Apply thread sealant to the male threads of the 3/8
npt swivel union (2d). Screw the union into the pump
air inlet (D).
5. Apply thread sealant to the male threads of the 1/2
npt swivel union (2b). Screw the union into the pump
fluid outlet (N).
6. Connect the 1/2 npt(mbe) fluid hose (2a) to the
swivel union (2b).
7. Connect the 3/8 npt(mbe) air hose (2c) to the swivel
union (2d).
2b
2a
2c
M
T
P
Model 225931
F
IG. 7
12Installation and Operation
Page 13
Installation
Mobil Mounting
Mobil Mounting Layout
Plan the layout for easy operator access to the pump air
controls, sufficient space to change drums, and a
secure mounting platform.
Drum Mounting
1. Place the drum in the desired location.
2. Place the hold-down lugs (Y) or drum locators (X)
around the drum base and bolt directly to the truck
bet or mounting platform. See F
T
IG. 8.
U
V
W
Closed Bung-Type-Drum, Cover-Mounted
Pump
1. Insert the pump extension tube through the gasket
(Z) and drum cover (AA). Fasten the Fire-Ball 300
from the top and the Fire-Ball 425 from the bottom.
See F
IG. 9.
2. Slide the rubber grommet (BB), tapered end down,
onto the extension tube and push it up against the
pump base. See F
3. Guide the pump extension tube through the drum
bung hole (CC) and place the cover on the drum.
See F
IG. 9.
4. Align the drum cover eyelets (T) with the hold-down
rods (W), install the hold-down brackets (V) and
wing nuts (U) and tighten securely. See F
ZGasket
AA Drum cover
BB Grommet
CC Bung Hole
IG. 9.
IG. 8.
X
TDrum cover eyelets
UWing nuts
VHold-down brackets
W Hold-down rods
XDrum locators
YHold-down rod lugs
F
IG. 8
Y
Open Drum, Cover-Mounted Pumps
1. Remove the original drum cover.
2. Mount the new drum cover and fasten in place.
3. Guide the pump extension tube through the mounting gasket.
F
Z
AA
BB
CC
IG. 9
4. Align the drum cover eyelets (T) with the hold-down
rods (W), install the cover brackets (V) and wing
nuts (U) and tighten securely. See F
IG. 8.
Installation and Operation13
Page 14
Closed Bung-Type-Drum,
Sturdi-Clamp-Mounted Pumps
Installation
1. Remove the adjustable bung adapter fro the pump
extension tube.
2. Screw the bung adapter (HH) into the bung hole.
3. Loosen the wing nuts (EE) and slide the clamp (DD)
onto the pump extension tube, up to the base. See
F
IG. 10.
4. Holding the clamp onto the pump, insert the pump
extension tube through the bung adapter, and lower
the pump until the clamp rests on the edge of the
drum. See F
IG. 10.
5. Install the sturdi-clamp so its upper jaw fits against
the pump base projection, its u-bolt (GG) fits around
the extension tube, and its lower jaw fits against the
bung adapter. Tighten the wing nuts (EE). See F
IG.
10.
6. Tighten the T-handle (FF) firmly to the side of the
drum.
See FIG. 1 to identify references shown in parentheses,
i.e.,(A).
WARNING
This equipment stays pressurized until pressure is
manually relieved. Read PRESURIZED EQUIPMENT
HAZARD warnings on page 4.
Maximum working pressure of all components in the
system may not be the same. To reduce risk of overpressurizing any component, be sure you know the
maximum working pressure of each component.
Never exceed the maximum working pressure of the
lowest rated component in the system. Overpressurizing any component can result in rupture, fire, explosion, property damage, and serious injury.
To determine the fluid output pressure using the air
regulator reading, multiply the ratio of the pump by the
air pressure shown on the regulator gauge. For example:
3 (:1) ratio x 100 psi air = 300 psi fluid output
Limit the air pressure to the pump so that no air line or
fluid line component is overpressurized.
Relieving Pressure
1. Close the pump air regulator (C) and the bleed-type
master air valves (A) (required in your system).
2. Hold a metal part of the dispensing valve (H) firmly
to a grounded metal waste container, and trigger the
valve to relieve the fluid pressure.
3. Open the pump air regulator (C) slowly, just until the
pump is running. When the pump is primed and all
air has been pushed out of the lines, close the dispensing valve (H).
NOTE: When the pump is primed, and with sufficient air
supplied, the pump starts when the dispensing valve (H)
is opened, and shuts off when it is closed.
4. Adjust the air regulator (C) until you get sufficient
flow from dispensing valve (H). Always run the
pump at the lowest pressure necessary to get the
desired results. Do not exceed the maximum working pressure of any component in the system.
CAUTION
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly causing pump damage. It may also get
very hot.
5. If your pump accelerates quickly or is running too
fast, stop it immediately and check the fluid supply. If
the supply container is empty and air has been
pumped into the lines, prime the pump and lines
with fluid, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid
lines.
6. Read and follow the instructions supplied with each
component in your system.
7. If the pump will be unattended for any period of
time, if there is an air supply interruption, or at the
end of the work shift, shut off the system and always
relieve the pressure.
Starting and Adjusting the Pump
WARNING
Read the MOVING PARTS HAZARD and TOXIC
FLUID OR FUMES warnings on page 5
1. With the air regulator (C) closed, open the
bleed-type master air valve (A).
2. Open the dispensing valve (H) into a grounded
metal waste container, making firm metal-to-metal
contact between the container and valve.
Installation and Operation15
Page 16
Parts
Universal Pump Package
Fire-Ball 225 Model 248230
Fire-Ball 300 Model 225852
Fire-Ball 425 Model 225853
1
Parts
2d
2c
2b
2a
16Installation and Operation
Page 17
Parts
Parts List
Ref.
No.Part No. DescriptionQty.
1246775 PUMP, Mini-Fire-Ball 225 3:1,
universal; (for 248230, see 309869
for parts)
203876 Pump, Fire-Ball 300 5:1,
universal; (for 225852, see 309869
for parts)
205626 Pump, Fire-Ball 425 10:1,
universal; (for 225853, see 309869
for parts
2222062 HOSE AND FITTING KIT;
(for 248230 and 225852) Includes
items 2a-2d
222068 HOSE AND FITTING KIT;
(for 225853) Includes items 2a-2d
Ref.
No.Part No. DescriptionQty.
2a220598
•FLUID HOSE,1/2’ ID, cpld
1/2-14 npt(m), 18 in. (457 mm) (for
1
2b155470
1
2c204560
1
2d155494
1
109108
160327
218093
155470
222062)
•FLUID HOSE, (for 222068)1
•UNION, swivel, 90°; 1/2 npt(m) x
1/2 npsm(f) (for 222062)
•UNION, 90°, 3/4-14 (for 222068)1
•AIR HOSE, 3/8 in. ID, cpld
3/8-18 npt(m), 18 in. (457 mm)
(for 222062)
•AIR HOSE, (for 222068)1
•UNION, swivel, 90°; 3/8 npt(m) x
3/8 npsm(f) (for 222062)
•UNION, swivel, 90°; 1/2 npt(m) x
1/2 npsm(f)
(for 222068)
1
1
1
1
1
1
Installation and Operation17
Page 18
16-gallon (60 Liter) Gear Lube Dispenser
Fire-Ball 225 Model 246903
Fire-Ball 300 Model 225728
1
Parts
3b
3d
3d
3a
4
3c
5
2a
2b
18Installation and Operation
Page 19
Parts List
Parts
Ref.
No. Part No. Description
1248097 PUMP, Mini-Fire-Ball 225 3:1,
multi-length; (for 246903, see
309869 for parts)
203872 PUMP, Fire-Ball 300 5:1; (for
225728, see 309869 for parts)
2237075 DISPENSE KIT;
Included items 2a and 2b
See manual 307884
2a220591
2b238463
• HOSE, coupled, 6 ft.
(1/2 in. npt (mbe)
• VALVE, dispense1
3224512 AIR REGULATOR KIT
Includes items 3a-3d
3a110234
• REGULATOR, air; 3/8 npt(f)
0-250 psi
0-1.7 MPa, 0-14.4 bar) range
See manual 308167
3b100960
3c110224
3d156849
• GAUGE, air pressure1
• VALVE, air, bleed-type; 3/8 npt(f)
• NIPPLE, 3/8 npt
4204574 COVER, drum;
See manual 306345 for parts
5203622 PORTABLE BASE;
See manual 308668 for parts
Qty.
1
1
1
1
1
1
2
1
1
Installation and Operation19
Page 20
16-gallon (60 Liter) Drum Cover Pump
Fire-Ball 225 Model 246904
Fire-Ball 300 Model 225094
1
3d
3b
3d
3c
2d
Parts
2b
2a
2c
3a
4
20Installation and Operation
Page 21
Parts List
Parts
Ref.
No. Part No. Description
1248097 PUMP, Mini-Fire-Ball 225 3:1,
multi-length; (for 246904, see
309869 for parts)
203872 PUMP, Fire-Ball 300 5:1; (for
225094, see 309869 for parts)
2222063 HOSE AND FITTING KIT
Includes items 2a-2d
2a220591
2b155470
2c203320
2d155494
• HOSE, fluid; nitrile; 1/2 in. ID;
1/2 npt(mbe); 6 ft (1.83 m)
• UNION, swivel, 90°; 1/2 npt(m) x
1/2 npsm(f)1
• HOSE, air; buna–N; 3/8 in. ID;
3/8 npt(mbe); 6 ft (1.83 m)
• UNION, swivel, 90°; 3/8 npt(m) x
3/8 npsm)
3224512 AIR REGULATOR KIT
Includes items 3a-3d
3a110234
• REGULATOR, air; 3/8 npt(f)
0-250 psi
0-1.7 MPa, 0-14.4 bar) range
See manual 308167
3b100960
3c110224
3d156849
• GAUGE, air pressure1
• VALVE, air, bleed-type; 3/8 npt(f)
• NIPPLE, 3/8 npt
4204574 COVER, drum;
See 306345 for parts
Qty.
1
1
1
1
1
1
1
1
1
1
2
1
Installation and Operation21
Page 22
55-gallon (208 Liter) Drum Cover Pump
Fire-Ball 225 Model 246906
Fire-Ball 300 Model 225642
Fire-Ball 425 Model 225782
1
3d
3b
3d
3c
2d
Parts
2b
2a
2c
3a
4
22Installation and Operation
Page 23
Parts
Ref.
No. Part No. Description
1248097 PUMP, Mini-Fire-Ball 225 3:1,
multi-length; (for 246906, see
309869 for parts)
203857 PUMP, Fire-Ball 300 5:1; (for
225642, see 309869 for parts)
222065 PUMP, Fire-Ball 425 10:1; (for
225782, see 309869 for parts)
2222063 HOSE AND FITTING KIT
(for 246906 and 225642)
Includes items 2a-2d
222066 HOSE AND FITTING KIT
(for 225782) Includes items 2a-2d
2a220591
• HOSE, fluid; nitrile; 1/2 in. ID;
1/2 npt(mbe); 6 ft (1.83 m)
(for 222063)
109105
• HOSE, fluid; nitrile; 3/4 in. ID;
3/4 npt(mbe); 6 ft (1.83 m)
(for 222066)
2b155470
160327
2c203320
• UNION, swivel, 90°; 1/2 npt(m) x
1/2 npsm(f)
• UNION, swivel, 90°; 3/4 npt(m) x
3/4 npsm(f)
• HOSE, air; buna–N; 3/8 in. ID;
3/8 npt(mbe); 6 ft (1.83 m)
(for 222063)
(for 222066)
(for 222063)
205418
• HOSE, air; buna–N; 1/2 in. ID;
1/2 npt(mbe); 6 ft (1.83 m)
(for 222066)
2d155494
• UNION, swivel, 90°; 3/8 npt(m) x
3/8 npsm)
(for 222063)
155470
• UNION, swivel, 90°; 1/2-14 npt(m) x
1/2 npsm(f)
(for 222066)
3224512 AIR REGULATOR KIT
(for 246906 and 225642 only)
Includes items 3a-3d
3a110234
• REGULATOR, air; 3/8 npt(f)
0-250 psi
0-1.7 MPa, 0-14.4 bar) range
See manual 308167
3b100960
3c110224
3d156849
• GAUGE, air pressure1
• VALVE, air, bleed-type; 3/8 npt(f)
• NIPPLE, 3/8 npt
4200326 COVER, drum;
See 306345 for parts
Qty.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Installation and Operation23
Page 24
55-/275-gallon (208 Liter) Drum Bung-Mount Pump
Fire-Ball 225 Model 246907
Fire-Ball 300 Model 225640
Fire-Ball 300 Model 225931
Fire-Ball 425 Model 225786
1
2b
Parts
2c
2d
2a
24Installation and Operation
Page 25
Parts List
Parts
Ref.
No. Part No. Description
1248097 PUMP, Mini-Fire-Ball 225 3:1, multi-
length; (for 246907, see 309869 for
parts)
204254 PUMP, Fire-Ball 300 5:1; (for
225640, see 309869 for parts)
222087 PUMP, Fire-Ball 300 5:1; (for
225931, see 309869 for parts)
222095 PUMP, Fire-Ball 425 10:1; (for
225786, see 309869 for parts)
2222063 HOSE AND FITTING KIT
(for 246907, 225640 and 225931)
Includes items 2a-2d
222066 HOSE AND FITTING KIT
(for 225786) Includes items 2a-2d
2a220591
• HOSE, fluid; nitrile; 1/2 in. ID;
1/2 npt(mbe); 6 ft (1.83 m)
(for 222063)
109105
• HOSE, fluid; nitrile; 3/4 in. ID;
3/4 npt(mbe); 6 ft (1.83 m)
Air inlet port size ......................................... 1/2 in. npt(f)
Fluid inlet port size ...................................... 1.5 in. npt(f)
Fluid outlet port size.................................... 3/4 in. npt(f)
Sound pressure (measured 1 meter from unit).80.85dB
Sound pressure (ISO 9614-2) ........................... 94.62dB
Page 31
Dimensions
Fire-Ball 225
Model 246775
Universal
Dimensions
Model 246775
Universal
Overall Length: 18.9 in. (48 cm)
3/8 in. npt(f)
air inlet
8.9 in.
(20 cm)
Mounting Hole Layout
Grounding
screw
1/2 in. npt(f)
fluid outlet
1-1/2 in. npt
05752
Model 248097
Variable length
Overall Length: 59.2 in. (150.4 cm)
Model 248097
Variable length
3/8 in. npt(f)
air inlet
8.9 in.
(20 cm)
grounding
screw
1/2 in. npt(f)
fluid outlet
40.68 in. (103.33
cm) drop tube is
4.250 in. (10.8 cm) bolt circle
0.281 in. (7.1 mm) diameter clearance holes
Installation and Operation31
cut to length
Page 32
Fire-Ball 300
Model 203857
Dimensions
3/8 in. npt(f)
air inlet
Model 203876
Universal
8.9 in.
(22.6 cm)
05750
Overall Length: 20.7 in (52.6 cm)
grounding
screw
1/2 in. npt(f)
fluid outlet
55-gal. (400 lb) drum size, cover mount
Overall Length: 45.6 in. (115.8 cm)
Model 203872
16-gal. (120 lb) drum size, cover mount
Overall Length: 38.1 in. (96.8 cm)
Model 204254
55-gal. (400 lb) drum size, bung mount
Overall Length: 49.9 in. (126.7 cm)
Model 222087
275-gal. tank size, bung mount
Overall Length: 59.9 in. (152.1 cm)
Mounting Hole Layout
Part No. 161023
Two 0.265-in. (.673 cm)
diameter holes on 5-in.
(12.7 cm) bolt circle
Four 0.265-in. (.673 cm)
diameter holes on 5-in.
(12.7 cm) bolt circle
3-in. (7.62 cm)
2-Hole
Mounting Pattern
diameter hole
Gasket
4-Hole
Mounting Pattern
3/8 in. npt(f)
air inlet
04127
Model 203857
33.8 in. (85.9 cm)
Model 203872
26.3in. 66.9 cm)
Model 204254
38.1in. (96.8 cm)
Model 222087
48.1 in. (122.2 cm)
grounding
screw
1/2 in. npt(f)
fluid outlet
05754
32Installation and Operation
Page 33
Fire-Ball 425
Model 205626
1/2 in. npt
air inlet
3/4 in. npt
fluid outlet
Dimensions
Universal
18.4in.
(46.7 cm)
Model
205626
25.8 in.
(65.5 cm)
3/4 in npt
muffler port
Note: For
sealed tank
mounting use
gasket 192658.
7.4 in.
(18.8 cm)
06035
Model 222065
32.3 in. (82 cm)
Model 222095
36.6 in. (92.9 cm)
45°
45_
Mounting Hole Layout
2.25-in. (5.7 cm)
diameter clearance hole
Four 0.406-in.
(1.03 cm)
diameter holes
on 7-in. (17.8
cm) bolt circle
Four threaded
holes on bottom
of air motor base
are 1/4-20 UNC
on 4.25-in. (10.8
cm) bolt circle.
8.0-in. (20.3 cm)
diameter of flange
Installation and Operation33
Page 34
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material
and workmanship on the date of sale to the original purchaser. With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance
of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor,orcall this number to identify the distributor closest to you:
1-800-533-9655 Toll Free
612-623-6928
612-378-3590 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
MM 309868
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441MINNEAPOLIS, MN 55440-1441
www.graco.com
Installation and Operation 6/2006
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.