Graco 225 User Manual

Installation and Operation
Mascott Equipment Co Portland Seattle Pasco (800) 452-5019 (800) 481-7311 (888) 450-7867
Fire-Ball
®
225, 300, and 425 Oil Pumps
For non-corrosive and non-abrasive oils and lubricants only.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
540 psi (3.7 MPa, 37 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 300, 5:1 Parts 203876, 203872, 203857, 204254, and 222087
900 psi (6.2 MPa, 62 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
309868B
Fire-Ball 425, 10:1 Parts 205626, 222065, and 222095
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001

Contents

Contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . 4
Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Mounting the Pump . . . . . . . . . . . . . . . . . . . . . . . 7
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mobil Mounting . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Relieving Pressure . . . . . . . . . . . . . . . . . . . . . . 15
Starting and Adjusting the Pump . . . . . . . . . . . 15
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Universal Pump Package
Fire-Ball 225 Model 248230 Fire-Ball 300 Model 225852
Fire-Ball 425 Model 225853 . . . . . . . . . . . . 16
16-gallon (60 Liter) Gear Lube Dispenser
Fire-Ball 225 Model 246903
Fire-Ball 300 Model 225728 . . . . . . . . . . . . 18
16-gallon (60 Liter) Drum Cover Pump
Fire-Ball 225 Model 246904
Fire-Ball 300 Model 225094 . . . . . . . . . . . . 20
55-gallon (208 Liter) Drum Cover Pump
Fire-Ball 225 Model 246906 Fire-Ball 300 Model 225642
Fire-Ball 425 Model 225782 . . . . . . . . . . . . 22
55-/275-gallon (208 Liter) Drum Bung-Mount Pump
Fire-Ball 225 Model 246907
Fire-Ball 300 Model 225640 Fire-Ball 300 Model 225931
Fire-Ball 425 Model 225786 . . . . . . . . . . . . 24
16-gallon (60 Liter) Drum Cover, Truck Mounted
Pump
Fire-Ball 300 Model 222086 . . . . . . . . . . . . 26
55-gallon (208 Liter) Drum Cover, Truck Mounted
Pump Fire-Ball 300 Model 206655
Fire-Ball 425 Model 206656 . . . . . . . . . . . . 27
55-gallon (208 Liter) Bung Adapter, Truck Mounted
Pump Fire-Ball 300 Model 204264
Fire-Ball 425 Model 222067 . . . . . . . . . . . . 28
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Fire-Ball 225 (3:1) . . . . . . . . . . . . . . . . . . . . . . . 30
Fire-Ball 300 (5:1) . . . . . . . . . . . . . . . . . . . . . . . 30
Fire-Ball 425 (10:1) . . . . . . . . . . . . . . . . . . . . . . 30
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fire-Ball 225 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fire-Ball 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Fire-Ball 425 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 34
Graco Information . . . . . . . . . . . . . . . . . . . . . . . 34
Additional Reference Manuals
This manual covers the installation and operation of Graco Fire-Ball pumps. For information on service and repair of these pumps, please see the following manual.
Fire-Ball Pump Service, Troubleshooting, and Repair 309869.
You should also read the instruction manuals for all components of your system.
2 Installation and Operation

Packages

Packages
Model/
Package No. Pump Description
Fire-Ball 225 Packages
248230
246903
246904
246906
246907
Fire-Ball 300 Packages
225852
225728
225094
225642
225640
225931
222086
206655
204264
246775 Universal
248097
248097 16 gallon (60 liter), drum
248097 55 gallon (208 liter), drum
248097 55/275 gallon (208/1041 liter),
203876
203872
203872 16 gallon (60 liter), drum
203857 55 gallon (208 liter), drum
204254 55 gallon (208 liter), bung
222087 275 gallon (1041 liter)
203872 16 gallon (60 liter), drum
203857 55 gallon (208 liter) drum
204254 55 gallon (208 liter) bung
16 gallon (60 liter), gear lube 204574 237075 224512
cover 222063 204574 224512
cover 222063 200326 224512
bung mount 222063 222308
Universal 222062
16 gallon (60 liter), gear lube 204574 237075 224512
cover 222063 204574
cover 222063 200326
mount 222063 222308
obround tank 222063 222308
cover, truck mount 222063 222060
cover, truck mount 222063 207367
adapter, truck mount 222063 204076
Hose/
Fitting Kit
222062
Cover/Bung
Adapter
Dispense
Kit
Air
Regulator
Fire-Ball 425 Packages
225853
225782
225786
206656
222067
Installation and Operation 3
205626
222065 55 gallon drum (208 liter),
222095 55 gallon (208 liter), bung
222065 55 gallon (208 liter) drum
222095 55 gallon (208 liter) bung
Universal 222068
drum cover 222066 200326
adapter 222066 222308
cover, truck mount 222066 207367
adapter, truck mount 222066 224579

Manual Conventions

Warning Caution
Manual Conventions
WARNING
A warning alerts you to possible serious injury or death if you do not follow instructions.
Symbols, such as fire and explosion (shown), alert you to a specific hazard and direct you to read the indi­cated hazard warnings beginning on page 4.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your Graco distributor for information.
For professional use only.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not use hoses to pull equipment.
Comply with all applicable safety regulations.
CAUTION
A caution alerts you to possible equipment damage or destruction if you do not follow instructions.
Note
A note indicates additional helpful information.
WARNINGS
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.
Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
Tighten all fluid connections before operating the equipment.
Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
4 Installation and Operation
Warning
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
Do not point gun at anyone or at any part of the body.
Do not put your hand over the spray tip.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Do not spray without tip guard and trigger guard installed.
Engage trigger lock when not spraying.
Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
Ground equipment and conductive objects. See Grounding instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering into pail.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
Installation and Operation 5

Installation

The typical stationary installation shown in is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco distributor for
assistance in designing a system to meet your needs.
.
F
A
C
L
D
Installation
Letters used to identify components in FIG. 1 are referred to in the package installation drawings, F
IG. 3 through FIG. 7. Additional letter references
are used in installation drawings as necessary.
E
J
N
H
P
Key
A Bleed-type master air valve B Air line filter C Air regulator and gauge D Air inlet E Ground wire F Pump G Drain valve
M
B
G
K
H Dispensing valve J Fluid hose K Thermal relief kit (235998) L Air line lubricator M Bung adapter N Fluid outlet P Extension tube
FIG. 1
6 Installation and Operation
Installation
Mounting the Pump
WARNING
Mount the pump securely so that it cannot move dur­ing operation. Failure to do so could result in personal injury or equipment damage.
Select a location that allows the operator easy access to the pump and air controls, sufficient room to change supply containers, and a secure mount­ing platform.
If you are mounting the pump directly on the supply container, be sure it is positioned so the pump’s intake tube is no more than 1 in. (25 mm) from the bottom of the container. Mount the pump to the cover or other suitable mounting device.
To prevent damage to the pump, remove sedi­ment from the bottom of the container before installing a pump in an existing container.
Grounding
To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the dispensing valve firmly to the side of a metal pail and then open the dispensing valve.
To maintain grounding continuity when flushing or reliev­ing pressure, always hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.
To ground the pump, remove the ground screw (Z) and insert through the eye of the ring terminal at end of ground wire, (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See F a ground wire and clamp order Part No. 222011.
Z
IG. 2. To order
Y
Proper grounding is essential to maintaining a safe sys­tem.
To reduce the risk of static sparking, ground the pump. Check local electrical codes for detailed grounding instructions for your area and equipment type. Be sure the following equipment is properly grounded:
Pump: See F
Air and Fluid hoses: Use only electrically conductive hoses.
Air compressor: Follow manufacturer’s recommen­dations.
Dispensing valve: Obtain grounding through con­nection to a properly grounded fluid hose and pump.
Fluid supply container: Follow your local code.
Object being lubricated: Follow your local code.
Any pails used when flushing: Use only metal, grounded pails when flushing. Make firm metal-to-metal contact between a metal part of the dispensing valve and the pail. Use the lowest possi­ble pressure.
IG. 2
F
TI1052
IG. 2
Installation and Operation 7
Installation
Universal Pump Fire-Ball 225 Model 248230 Fire-Ball 300 Model 225852 Fire-Ball 425 Model 225853
1. Apply thread sealant to the male threads of the 3/8 npt swivel union (2d). Screw the union into the pump air inlet (D).
F
D
2d
2. Apply thread sealant to the male threads of the 1/2 npt swivel union (2b). Screw the union into the pump fluid outlet (N).
3. Connect the 1/2 npt(mbe) fluid hose (2a) to the swivel union (2b).
4. Connect the 3/8 npt(mbe) air hose (2c) to the swivel union (2d).
N
2b
2a
F
2c
IG. 3
8 Installation and Operation
Installation
16-Gallon (60 Liter) Gear Lube Dispenser Fire-Ball 225 Model 246903 Fire-Ball 300 Model 225728
1. Assemble the base (5) as shown in FIG. 4. Place an opened 16-gallon (60 liter) drum on the base and secure it with the hold-down clamps. Tighten the hold-down clamp bolts
2. For 246903, cut the extension tube (P) at a 45° angle to a length appropriate for the size of the
F
3b
D
3d
3d
R
N
drum. When installed, the bottom of the angle should be about 1” (25 mm) from the bottom of the drum. The down tube for 225728 is sized for the container.
3. Set the cover (4) on the drum and secure the thumbscrews (Q). Install the pump (F) on the cover (4) with the screws (R), washers and nuts (S) pro­vided
4. Connect the hose (2a) to the pump fluid outlet (N).
2a
2b
3a
4
3c
Q
P
5
S
F
IG. 4
Installation and Operation 9
Installation
16-Gallon (60 Liter) Drum Cover Pump Fire-Ball 225 Model 246904 Fire-Ball 300 Model 225094
1. Set the cover (4) on a 16-gallon (60 liter) drum and secure with the thumbscrews (Q). See F
2. For 246904 cut the extension tube (P) at a 45° angle to a length appropriate for the size of the drum. When installed, the bottom of the angle should be about 1” (25 mm) from the bottom of the drum. The down tube for 225094 is sized for the container.
3. Install the pump (F) on the cover (4) with the screws (R), washers and nuts (S) supplied.
IG. 5.
F
4. Assemble the air regulator kit (items 3a-3d) to the pump air inlet (D) as shown. Use thread sealant and tighten all parts securely.
5. Apply thread sealant to the male threads of the 3/8 npt swivel union (2d). Screw the union into the bleed-type master air valve (3c).
6. Apply thread sealant to the male threads of the 1/2 npt swivel union (2b). Screw the union into the pump fluid outlet (N).
7. Connect the 1/2 npt(mbe) fluid hose (2a) to the swivel union (2b).
8. Connect the 3/8 npt(mbe) air hose (2c) to the swivel union (2d).
2d
2c
3c
3b
3d
Q
3d
D
A
3a
P
4
R
N
2b
2a
S
F
IG. 5
10 Installation and Operation
Installation
55-Gallon (208 Liter) Drum Cover Pump Fire-Ball 225 Model 246906 Fire-Ball 300 Model 225642 Fire-Ball 425 Model 225782
1. For 246906 cut the extension tube (P) at a 45° angle to a length appropriate for the size of the drum. When installed, the bottom of the angle should be about 1” (25 mm) from the bottom of the drum. For 225642 and 225782 the down tube is sized for the container.
2. Set the cover (4) on a 55-gallon (208 liter) drum. Install the pump (F) on the cover with the screws (R) supplied. See F
IG. 6
3b
3d
F
3d
D
3. Assemble the air regulator kit (items 3a-3d) to the pump air inlet (D) as shown. Use thread sealant and tighten all parts securely.
4. Apply thread sealant to the male threads of the 3/8 npt swivel union (2d). Screw the union into the bleed-type master air valve (3c).
5. Apply thread sealant to the male threads of the 1/2 npt swivel union (2b). Screw the union into the pump fluid outlet (N).
6. Connect the 1/2 npt(mbe) fluid hose (2a) to the swivel union (2b).
7. Connect the 3/8 npt(mbe) air hose (2c) to the swivel union (2d).
R
N
2b
2c
3c
2a
2d
3a
4
P
F
IG. 6
Installation and Operation 11
Loading...
+ 23 hidden pages