Graco 223627, 208085, 223621, 208082, 223622 Instructions-parts List Manual

...
Instructions–Parts List
Fluid Controls and Fittings
200 psi (1.4 MPa, 14 bar) Maximum Inbound Fluid Pressure
Part No.s 223625 and 223628
300 psi (2.1 MPa, 21 bar) Maximum Inbound Fluid Pressure
TWIST LOCK SLIP RING
COUPLER
STEMS
3/8 npsm
Models
GUN
MOUNTED
REGULATORS
FLUID
1/4 npsm inlet &
return ports
5 to 35 psi
(0.5 to 2.5 bar)
Regulated
Pressure
223627*
1.0 oz
208085*
1.5 oz
UNION ADAPTER
307016S
TWIST LOCK
223628*
1.3 oz
02286
Important Safety Instructions
Read all warnings and instructions in this manual. See page 2 for Table of Contents. Save these instructions.
* Stainless Steel Models
Models
STRAIGHT
ADAPTERS
3/8 npsm inlet
Models
CIRCULATING
ADAPTERS
1/4 npsm inlet &
return ports
Models
223621*
7.0 oz
223624*
214019 223626*
208082*
7.5 oz
208250
223622*{
7.0 oz
223623*
7.3 oz
223625*
210097
Table of Contents
Symbols
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Standard Warranty 10. . . . . . . . . . . . . . . . . . . . . .
Graco Information 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.
NOTE: The following warning applies only to Models 214018, 208250, 214019, & 210097, which contain aluminum housings.
WARNING
Hazard of Using Fluids Containing Halogenated Hydrocarbons
Never use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids contain­ing such solvents in the models listed in the not above. Such use could result in a serious chemical reaction, with the possibility of explosion, which could cause death, serious injury and/or substantial property damage.
Consult you fluid suppliers to ensure that the fluids being used are compatible with aluminum parts.
Installation
Connect the Fluid Hose
Regulators or Circulating Adapters:
Connect the fluid hoses to the 1/4 npsm(m) inlet and return fittings.
Straight Adapter:
Connect a hose to the 3/8 npsm(m) inlet fitting.
Connect the Regulator or Adapter to the Gun
Model 223622:
Screw the regulator union adapter onto the gun fluid inlet.
Models with Twist-lock Couplers:
Screw the coupler stem onto the gun inlet. Connect the twist-lock couplers by lining up the coupler slots with the pins on the stem, pushing the coupler onto the stem, then twisting the coupler clockwise to lock it.
Models with Slip-ring Couplers:
Pull the slip ring back as you push the coupler onto the stem.
2 307016
Operation
CAUTION
To avoid damaging the regulator diaphragm, never exceed 200 psi (1.4 MPa, 14 bar) Maximum Inbound Fluid Pressure to the regulator.
Service
WARNING
To reduce the risk of serious injury, including splashing in the eyes or on the skin, always shut off the air and fluid pressure to the gun and trigger the gun to relieve fluid pressure in the hoses before disconnecting hoses from the regulator or adapter.
To Clean or Service the Regulator
1. Relieve the air and fluid pressures.
2. Disconnect the regulator from the gun and the hoses from the regulator.
To Adjust the Fluid Pressure
Trigger the gun. Turn the fluid regulator setscrew (2) clockwise to the desired setting. Release the gun trigger, tighten the locknut (1), and install the acorn nut (16).
4. Clean and inspect the parts carefully.
5. Replace worn or damaged parts and reassemble the regulator. Be sure the nylon side of the dia­phragm (12) faces the fluid.
Torque Notes:
Diaphragm Nut (3) onto Valve Stem (8):
6 to 10 in-lb (0.7 to 1.1 NSm)
Screws (5) into the Housing (18):
20 to 30 in-lb (2.3 to 3.4 NSm)
3. Disassemble the regulator. Refer to the Parts Drawing.
Cap (14 )into the Housing (18):
10 to 15 ft-lb (13.5 to 20.0 NSm)
307016 3