Instructions-Parts
15V534 Gun Flush
313212A
Box Interface Kit
Interfaces a Graco Gun Flush Box with a ProMix® 2KS Electronic Proportioner using a
RoboMix Fluid Station. For professional use only.
Approved for use in explosive atmospheres only when used in conjunction with ProMix
2KS Electronic Proportioners.
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual. For complete
warnings and instructions see your proportioning system manual
and gun flush box manual 312784. Hazard symbols refer to specific procedure risks. Save all instructions.
ENG
GFB Interface Kit shown with
two air flow switches installed
0359
II 2 G
TI14275a
#53
Related Manuals
Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mount the Enclosure . . . . . . . . . . . . . . . . . . . . . . 3
Install the Cable . . . . . . . . . . . . . . . . . . . . . . . . . 4
Install the Air Flow Switch . . . . . . . . . . . . . . . . . . 5
Install the Pressure Switch . . . . . . . . . . . . . . . . . 6
Install the Solenoid . . . . . . . . . . . . . . . . . . . . . . . 7
Connect the Cable to the
RoboMix Control Board . . . . . . . . . . . . . . . . 8
Connect the Gun Flush Box . . . . . . . . . . . . . . . . 9
Connect Air Supply to Module . . . . . . . . . . . . . . 9
Replace the Cover . . . . . . . . . . . . . . . . . . . . . . . 9
Ground the Enclosure . . . . . . . . . . . . . . . . . . . . . 9
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Connect a Booth Control to the RoboMix
(to operate as a manual system) . . . . . . . . . . 12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 14
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . 14
Related Manuals
See the following manuals for additional information on
the ProMix 2KS and Gun Flush Box Kits.
Manual Description
312778 ProMix 2KS Automatic System
Installation
312779 ProMix 2KS Automatic System
Operation
312780 ProMix 2KS Automatic System
Repair-Parts
312784 Gun Flush Box Kits
Overview
Gun Flush Box Interface Kit 15V534 provides electrical
and air connections to enable a ProMix 2KS RoboMix
proportioner to operate one or two gun flush boxes. See
F
IG. 1 for the identification label.
Order Gun Flush Box Kit 15V826 separately (see manual 312784). Each 15V826 Kit includes one gun flush
box and related parts. The pressure switch, air flow
switch, and solenoid valve included in Gun Flush Box Kit
15V826 will be installed in this interface module.
ProMix™ 2KS
PART NO. SERIES SERIAL
GFB CONTROL MODULE
MAX AIR WPR
.7 7 100
Intrinsically safe equipment
for Class I, Div 1, Group D, T3
CUS
Ta = -20°C to 50°C
Install per 289833
Artwork No. 293514 Rev. B
F
IG. 1. GFB Interface Module Identification Label
MPa bar PSI
FM08ATEX0073
II 2 G
Ex ia IIA T3
GRACO INC.
P.O. Box 1441
Minneapolis, MN
55440 U.S.A.
2 313212A
Installation
• To avoid electric shock, ground all equipment.
Turn off equipment power and shut off power at
main circuit breaker before installing.
• All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
• Do not substitute system components as this
may impair intrinsic safety.
To reduce the risk of serious injury, including fluid
injection, splashing, pinching or injury from moving
parts, relieve pressure before installing the kit. Follow the Pressure Relief Procedure in the ProMix
2KS Operation or Service manual.
Installation
Location
Install the gun flush box module enclosure (1) within 15
ft (4.5 m) of the RoboMix, to ensure that the cable (23)
will reach the RoboMix. The module is approved for use
in a hazardous location. See F
IG. 1.
Mount the Enclosure
1. See Dimensions, page 13.
2. Ensure that the wall and mounting hardware are
strong enough to support the weight of the equipment, fluid, hoses, and stress caused during operation.
3. Using the equipment as a template, mark the
mounting holes on the wall at a convenient height
for the operator and so equipment is easily accessible for maintenance.
4. Drill mounting holes in the wall. Install anchors as
needed.
5. Bolt equipment securely.
313212A 3
Installation
Install the Cable
1. Loosen the captive screws and remove the front
cover from the enclosure.
2. The cable (23) has bare wires at both ends. Thread
the shortest end (4 in. [102 mm]) into the enclosure
through the strain relief bushing (7). See F
IG. 2.
3. Connect the cable wires to the left side of the terminal strip (12), as indicated by the label (20). See F
IG.
2 and Table 1.
20 12
7
F
IG. 2. Connect Cable to Terminal Strip
TI14279a
4. Connect the other end of the cable (5 in. [127 mm])
to pins 1-4 and 7-10 of the 10 position connector
(24) and pins 1-4 of the 6 position connector, as
shown in the Cable (23) Wire Harness Detail on
page 11.
Table 1: Terminal Strip Wire Connections
Pin No. Cable Wire Colors Pin No. Switch Wires
1 Black 1 Air Flow Switch 1 +
2 White 2 Air Flow Switch 1 3 Red 3 Air Flow Switch 2 +
4 Green 4 Air Flow Switch 2 5 Orange 5 Pressure Switch 1 +
6 Blue 6 Pressure Switch 1 7 White/Black 7 Pressure Switch 2 +
8 Red/Black 8 Pressure Switch 2 9 Green/Black 9 Solenoid 1, + (12V), Red
10 Orange/Black 10 Solenoid 1, - (COM), Black
11 Blue/Black 11 Solenoid 2, + (12V), Red
12 Red/White 12 Solenoid 2, - (COM), Black
4 313212A
Installation
Install the Air Flow Switch
NOTE: The GFB Interface Module Kit does not include
an air flow switch (AFS). The AFS is supplied with the
gun flush box kit. Install the AFS in the interface module
as follows.
1. Each gun flush box kit includes one air flow switch
(AFS). The GFB interface module can accommodate 1 or 2 air flow switches. Install the switch(es) in
the right side of the enclosure. See F
1
AFS is part of gun flush box kit; not included
with GFB Interface Kit.
IG. 3.
AFS#1
1
AFS#2
1
2. Connect the wires from AFS#1 to the right side of
the terminal strip (12) pins 1 (+) & 2 (-), as indicated
by the label (21). See F
IG. 4 and Table 1.
2112
TI14279a
FIG. 4. Connect Air Flow Switch to Terminal Strip
3. If using a second gun flush box, connect the wires
from AFS#2 to the right side of the terminal strip
(12) pins 3 (+) & 4 (-), as indicated by the label (21).
See F
IG. 4 and Table 1.
TI14281a
IG. 3. Install Air Flow Switch (two shown)
F
313212A 5