Graco 15V534 User Manual

Instructions-Parts
15V534 Gun Flush
313212A
Box Interface Kit
Interfaces a Graco Gun Flush Box with a ProMix® 2KS Electronic Proportioner using a RoboMix Fluid Station. For professional use only.
Approved for use in explosive atmospheres only when used in conjunction with ProMix 2KS Electronic Proportioners.
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual. For complete warnings and instructions see your proportioning system manual and gun flush box manual 312784. Hazard symbols refer to spe­cific procedure risks. Save all instructions.
ENG
GFB Interface Kit shown with two air flow switches installed
0359
II 2 G
TI14275a
#53

Related Manuals

Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mount the Enclosure . . . . . . . . . . . . . . . . . . . . . . 3
Install the Cable . . . . . . . . . . . . . . . . . . . . . . . . . 4
Install the Air Flow Switch . . . . . . . . . . . . . . . . . . 5
Install the Pressure Switch . . . . . . . . . . . . . . . . . 6
Install the Solenoid . . . . . . . . . . . . . . . . . . . . . . . 7
Connect the Cable to the
RoboMix Control Board . . . . . . . . . . . . . . . . 8
Connect the Gun Flush Box . . . . . . . . . . . . . . . . 9
Connect Air Supply to Module . . . . . . . . . . . . . . 9
Replace the Cover . . . . . . . . . . . . . . . . . . . . . . . 9
Ground the Enclosure . . . . . . . . . . . . . . . . . . . . . 9
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Connect a Booth Control to the RoboMix
(to operate as a manual system) . . . . . . . . . . 12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 14
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . 14
Related Manuals
See the following manuals for additional information on the ProMix 2KS and Gun Flush Box Kits.
Manual Description
312778 ProMix 2KS Automatic System
Installation
312779 ProMix 2KS Automatic System
Operation
312780 ProMix 2KS Automatic System
Repair-Parts
312784 Gun Flush Box Kits

Overview

Gun Flush Box Interface Kit 15V534 provides electrical and air connections to enable a ProMix 2KS RoboMix proportioner to operate one or two gun flush boxes. See F
IG. 1 for the identification label.
Order Gun Flush Box Kit 15V826 separately (see man­ual 312784). Each 15V826 Kit includes one gun flush box and related parts. The pressure switch, air flow switch, and solenoid valve included in Gun Flush Box Kit 15V826 will be installed in this interface module.
ProMix™ 2KS
PART NO. SERIES SERIAL
GFB CONTROL MODULE
MAX AIR WPR
.7 7 100
Intrinsically safe equipment for Class I, Div 1, Group D, T3
CUS
Ta = -20°C to 50°C Install per 289833
Artwork No. 293514 Rev. B
F
IG. 1. GFB Interface Module Identification Label
MPa bar PSI
FM08ATEX0073 II 2 G Ex ia IIA T3
GRACO INC. P.O. Box 1441 Minneapolis, MN 55440 U.S.A.
2 313212A

Installation

To avoid electric shock, ground all equipment. Turn off equipment power and shut off power at main circuit breaker before installing.
All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.
Do not substitute system components as this may impair intrinsic safety.
To reduce the risk of serious injury, including fluid injection, splashing, pinching or injury from moving parts, relieve pressure before installing the kit. Fol­low the Pressure Relief Procedure in the ProMix 2KS Operation or Service manual.
Installation

Location

Install the gun flush box module enclosure (1) within 15 ft (4.5 m) of the RoboMix, to ensure that the cable (23) will reach the RoboMix. The module is approved for use in a hazardous location. See F
IG. 1.

Mount the Enclosure

1. See Dimensions, page 13.
2. Ensure that the wall and mounting hardware are strong enough to support the weight of the equip­ment, fluid, hoses, and stress caused during opera­tion.
3. Using the equipment as a template, mark the mounting holes on the wall at a convenient height for the operator and so equipment is easily accessi­ble for maintenance.
4. Drill mounting holes in the wall. Install anchors as needed.
5. Bolt equipment securely.
313212A 3
Installation

Install the Cable

1. Loosen the captive screws and remove the front cover from the enclosure.
2. The cable (23) has bare wires at both ends. Thread the shortest end (4 in. [102 mm]) into the enclosure through the strain relief bushing (7). See F
IG. 2.
3. Connect the cable wires to the left side of the termi­nal strip (12), as indicated by the label (20). See F
IG.
2 and Table 1.
20 12
7
F
IG. 2. Connect Cable to Terminal Strip
TI14279a
4. Connect the other end of the cable (5 in. [127 mm]) to pins 1-4 and 7-10 of the 10 position connector (24) and pins 1-4 of the 6 position connector, as shown in the Cable (23) Wire Harness Detail on page 11.
Table 1: Terminal Strip Wire Connections
Pin No. Cable Wire Colors Pin No. Switch Wires
1 Black 1 Air Flow Switch 1 + 2 White 2 Air Flow Switch 1 ­3 Red 3 Air Flow Switch 2 + 4 Green 4 Air Flow Switch 2 ­5 Orange 5 Pressure Switch 1 + 6 Blue 6 Pressure Switch 1 ­7 White/Black 7 Pressure Switch 2 + 8 Red/Black 8 Pressure Switch 2 ­9 Green/Black 9 Solenoid 1, + (12V), Red 10 Orange/Black 10 Solenoid 1, - (COM), Black 11 Blue/Black 11 Solenoid 2, + (12V), Red 12 Red/White 12 Solenoid 2, - (COM), Black
4 313212A
Installation

Install the Air Flow Switch

NOTE: The GFB Interface Module Kit does not include
an air flow switch (AFS). The AFS is supplied with the gun flush box kit. Install the AFS in the interface module as follows.
1. Each gun flush box kit includes one air flow switch (AFS). The GFB interface module can accommo­date 1 or 2 air flow switches. Install the switch(es) in the right side of the enclosure. See F
1
AFS is part of gun flush box kit; not included with GFB Interface Kit.
IG. 3.
AFS#1
1
AFS#2
1
2. Connect the wires from AFS#1 to the right side of the terminal strip (12) pins 1 (+) & 2 (-), as indicated by the label (21). See F
IG. 4 and Table 1.
2112
TI14279a
FIG. 4. Connect Air Flow Switch to Terminal Strip
3. If using a second gun flush box, connect the wires from AFS#2 to the right side of the terminal strip (12) pins 3 (+) & 4 (-), as indicated by the label (21). See F
IG. 4 and Table 1.
TI14281a
IG. 3. Install Air Flow Switch (two shown)
F
313212A 5