15H876 Pressure
Transducer Kit
To replace pressure transducer on E-Flo® Electric Circulation Pumps.
For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual
and in E-Flo Repair-Parts manual 311594. Save
these instructions.
311600C
ENG
Kit also includes circuit board and label.
ti8721a
Pressure Relief Procedure
Pressure Relief
Procedure
System pressure can cause the pump to cycle unexpectedly, which could result in serious injury from
splashing or moving parts.
1. Set START/STOP switch to STOP.
2. Push in SECURE DISABLE switch.
3. Open the back pressure regulator and all fluid drain
valves in the system, having a waste container
ready to catch drainage. Leave open until you are
ready to pressurize system again.
4. Check that pressure gauges on fluid supply and
return lines read zero. If gauges do not read zero,
determine cause and carefully relieve pressure by
VERY SLOWLY loosening a fitting. Clear obstruction before pressurizing system again.
Kit Installation
1. Jog the motor to bring the stand side lower to the
bottom of its stroke.
2. Relieve pressure, page 2.
3. Shut off electrical power to the unit.
4. See F
IG. 1. Remove two screws (12) and the cover
(A).
12*
A
Kit Parts
NOTE: Pressure Transducer Kit 15H876 includes parts
to replace the pressure transducer. Parts included in the
kit are marked with an asterisk, for example (12*). Use
all the new parts in the kit.
Ref.
No. Part No. Description Qty
12* 116719 SCREW, 8-32 hex washer head
25a* n/a PRESSURE TRANSDUCER
25c* n/a CIRCUIT BOARD
33* n/a GASKET, circuit board
36* n/a LABEL, calibration
41* 111316 O-RING; chemically resistant fluo-
roelastomer
58* n/a SPACER; brass
Parts designated n/a are not available separately.
12
1
1
1
FIG. 1. Remove Cover
1
1
1
12*
ti8317b
2 311600C