To replace pressure transducer on E-Flo® Electric Circulation Pumps. For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual and in E-Flo Repair-Parts manual 311594. Save these instructions.
311600C
ENG
Kit also includes circuit board and label.
ti8721a

Pressure Relief Procedure

Pressure Relief Procedure
System pressure can cause the pump to cycle unex­pectedly, which could result in serious injury from splashing or moving parts.
1. Set START/STOP switch to STOP.
2. Push in SECURE DISABLE switch.
3. Open the back pressure regulator and all fluid drain valves in the system, having a waste container ready to catch drainage. Leave open until you are ready to pressurize system again.
4. Check that pressure gauges on fluid supply and return lines read zero. If gauges do not read zero, determine cause and carefully relieve pressure by VERY SLOWLY loosening a fitting. Clear obstruc­tion before pressurizing system again.

Kit Installation

1. Jog the motor to bring the stand side lower to the bottom of its stroke.
2. Relieve pressure, page 2.
3. Shut off electrical power to the unit.
4. See F
IG. 1. Remove two screws (12) and the cover
(A).
12*
A

Kit Parts

NOTE: Pressure Transducer Kit 15H876 includes parts
to replace the pressure transducer. Parts included in the kit are marked with an asterisk, for example (12*). Use all the new parts in the kit.
Ref. No. Part No. Description Qty
12* 116719 SCREW, 8-32 hex washer head 25a* n/a PRESSURE TRANSDUCER 25c* n/a CIRCUIT BOARD 33* n/a GASKET, circuit board 36* n/a LABEL, calibration 41* 111316 O-RING; chemically resistant fluo-
roelastomer
58* n/a SPACER; brass
Parts designated n/a are not available separately.
12
1 1 1
FIG. 1. Remove Cover
1 1
1
12*
ti8317b
2 311600C