AUTOMATIC SHUT-OFF NOZZLE FOR 333468A
DIESEL EXHAUST FLUID (DEF) (ISO 22241) EN • FR • ES
NOT APPROVED FOR USE IN EXPLOSIVE
ATMOSPHERES OR HAZARDOUS LOCATIONS
MODEL 127649
MAX WPR 345 kPa (3.4 bar) (50 psi)
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions
EN
INDEX
A GENERAL WARNINGS 3
B FIRST AID RULES 3
B.1 WARNINGS 4
C THE DISPENSING NOZZLE 6
C.1 INTENDED USE 6
D TECHNICAL DATA 6
E INSTALLATION 6
F MODES OF OPERATION 7
G PREVENTION MISFILLING (optional) 7
H PRELIMINARY CHECK 8
I INITIAL START UP 9
J MAINTENANCE 9
K MALFUNCTIONS 9
L DEMOLITION AND DISPOSAL 10
M DIMENSIONS 10
WARRANTY 12
2 M0302
A GENERAL WARNINGS
Important
precautions
Symbols used
in the manual
Manual preservation
Reproduction
rights
To ensure operator safety and to protect the pump from
potential damage, workers must be fully acquainted with
this instruction manual before performing any operation.
The following symbols will be used throughout the manual
to highlight safety information and precautions of particular
importance:
WARNING
This symbol indicates safe working practices for
operators and/or potentially exposed persons.
NOTICE
This symbol indicates that there is risk of damage to
the equipment and/or its components.
NOTE
This symbol indicates useful information.
This manual should be complete and legible throughout.
It should remain available to end users and specialist
installation and maintenance technicians for consultation at
any time.
All reproduction rights are reserved by Graco Inc. The text
cannot be reprinted without the written permission
B FIRST AID RULES
Contact with
the uid
WARNING
In the event of problems developing following EYE/SKIN
CONTACT, INHALATION or INGESTION of the treated product,
please refer to the SAFETY DATA SHEET of the uid handled.
EQUIPMENT MISUSE HAZARD
Keep the product to be dispensed away from eyes and skin
Keep the product to be dispensed out of reach of children
The nozzle must only be used for the purposes for which it
was designed
Using unsuitable component parts and materials
could be hazardous
Not checking correct part installation could be hazardous.
EN
M0302 3
EN
B.1 WARNINGS
The following warnings are for the setup, use, grounding, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to
procedure-specic risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specic hazard symbols and warnings not
covered in this section may apear thoughout the body of this manual where applicable.
EQUIPMENT
MISUSE
!
Toxic Fluid
or Fumes
Hazard
Misuse can cause death
or serious injury
Toxic uids or fumes can
cause serious injury or
death if splashed in the
eyes or on skin, inhaled, or
swallowed.
WARNING
Do not operate the unit when fatigued or under the inuence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated
system component. See Technical Data in all
equipment manuals.
Use uids and solvents that are compatible
with equipment wetted parts. See Technical
Data in all equipment manuals. Read uid
and solvent manufacturer’s warnings. For
complete information about your material,
request MSDS from distributor or retailer.
Do not leave the work area while equipment
is energized or under pressure.
Turn o all equipment when equipment is
not in use.
Check equipment daily. Repair or replace worn
or damaged parts immediately with genuine
manufacturer’s replacement parts only.
Do not alter or modify equipment. Alterations or modications may void agency approvals and create safety hazards.
Make sure all equipment is rated and approved
for the environment in which you are using it.
Use equipment only for it intended purpose.
Call your distributor for information.
Route hoses and cables away from trac areas,
sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses
to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
Read MSDS’s to know the specic hazards of
the uids you are using.
Store hazardous uid in approved containers, and dispose of it according to applicable
guidelines.
Prolonged contact with the treated product
may cause skin irritation: always wear protective gloves during dispensing.
4 M0302
Personal
Protective
Equipment
Wear appropriate protective equipment when in
the work area to help prevent serious injury, including eye injury, hearing loss,
inhalation of toxic fumes,
and burns.
This equipment includes but is not limited to:
Protective eyewear, safety shoes, close-tting
clothing and hearing protection.
Respirators, protective clothing, and gloves as
recommended by the uid and solvent manufacturer.
Wear protective equipment that is suited to the
operations that need to be performed and resistant to cleaning products.
P.N. 127649WATER/UREA SOLUTION - D.E.F. - AUS 32, ACCORDING TO DIN
CONDITIONS
OF USE AND
ENVIRONMENTAL
CONDITIONS
VICE, MADE OF NON-CONDUCTIVE PLASTIC AND DESIGNED TO BE USED WITH WATER/UREA SOLUTION (DEF,
AUS32). ALSO COMPATIBLE WITH WATER
70070
WATER
Refer to the product technical data
D TECHNICAL DATA
Part number
12764915 l/min 45 l/min 0.9 bar 1” GAS 20 mm 3.5 bar0.6 Kg
NOTE
Min. ow-rate
4 gpm 12 gpm 13 psi1” BSP .787 inc 50 psi1.3 lb
Max. ow-rate
Pressure loss at 35 l/
min (9.3 gpm)
Inlet thread with
swivel
External diameter
hose-end tting
Max. operating
pressure
The wetted materials used in this device are :
stainless steel, plastic and rubber suitable for AdBlue.
Weight
E INSTALLATION
FOREWORDThe automatic nozzles are supplied ready for use.
NOTICE
NOTICE
The nozzle features SWIVEL hose-end tting (complete
with O-ring) useful for connecting to the supply hose.
TO ENSURE PERFECT OPERATION, THE DEVICE MUST BE
USED TO DISPENSE FLUIDS WITH CHARACTERISTICS FALLING WITHIN THE FOLLOWING PARAMETERS:
- Pmin. : 1,5 bar / 22 psi - - Pmax: 3,5 bar / 50 psi
During installation, use adequate sealants, being
careful no residues remain inside the hose.
So as not to negatively affect product operation,
couple the hose-end fitting with the hose without
using tools such as pliers, etc.
Assembly will be easier if the swivel hose-end fitting
is already fitted on the nozzle.
Make sure the hoses and the suction tank are without threading scale or residues which could damage the nozzle and the accessories.
Apply adequate sealants on the male threads of the
connections and swivels
Do not use PTFE tape
NO PTFE TAPE
6 M0302
F MODES OF OPERATION
FOREWORDThe main feature of these nozzles is that they are easy to
1
ASSISTED MODE
2
AUTOMATIC MODE
NOTICE
use.
Two operating modes are available:
Dispense by operating the nozzle lever. To interrupt dispensing manually, release the lever.
Use the opening lever lock device for automatic dispensing.
To continue dispensing after automatic stop, the lever
must be fully released before proceeding to operate it
again.
To interrupt dispensing in manual mode, press the lever
again, thereby releasing the device, and then release.
Do not use the nozzle outside the parameters indicated on the ”technical specifications” chart
EN
NOTE
Dispensing is automatically interrupted due to the
shut-off device, which operates when the level of the
liquid reaches the end of the spout.
G PREVENTION MISFILLING (optional)
PREMISE
OPERATION
NOTICE
PART NUMBERDESCRIPTIONPICTURE
127652Magnet switch misl spout
127654Magnet adapter misl
Refuelling with the nozzle equipped with “magnet switch”
is only possible in combination with the “magnet adapter”
, so misfuelling into tanks is made impossible
The “magnet switch” is a xed magnetic eld within the
ller necks of the nozzle. This opens the magnet switch in
the spout, so it is only possible to dispense from the tank
where the magnet adaptor is installed.
Nozzles equipped with “magnet switch” work only in
combination with the “magnet adapter”. The “magnet adapter” is an optional to be bought separately.
adapter (installs into DN40
ller necks only
M0302 7
EN
H PRELIMINARY CHECK
NOTICECheck the correct operation of the lock device, ac-
LOW
CLIP
5 cm
CLIP
HIGH CLIP
MEDIUM
cording to the following procedure:
1 Take a graduated receptacle with a capacity of 20 litres (5
gal)
2 Begin dispensing into the receptacle, setting the lever in
the minimum ow position, until the receptacle is full.
3 Keeping the lever open, make sure the spout is sub-
merged by about 5 cm (2 inches).
4 The nozzle must stop, with a click of the lever.
5 Repeat the same operations with the lever in medium-
ow and maximum-ow position.
Check the correct operation of the stop device as described above.
6 If the nozzle stops during dispensing, check and reduce
the ow.
7 If the dispensing stop device fails to operate, replace the
nozzle.
8 M0302
I INITIAL START UP
FOREWORDOnly start dispensing after making sure that assembly and
WARNING
NOTICE
NOTICE
NOTICE
installation have been correctly performed.
TOXIC FLUID OR FUMES HAZARD
The faulty operation of this device could cause the spill
of liquids that are hazardous for people and the environment.
It is a good practice to only operate the nozzle lever
after making sure the spout has been properly inserted in the mouth of the tank to be filled.
When using for the first time and every time the
nozzle is used, following the connection of the supply hose, gently operate the lever to enable the air
to escape from the circuit, until normal operation is
achieved.
Check the correct operation of the automatic stop
device once the tank is full.
EN
NOTICE
Keep fresh water in nozzle path to prevent DEF
crystals from forming on nozzle end. The nozzle automatic cut off may fail if crystallization plugs the
nozzle orifice. The nozzle tip must be submerged in
water when the nozzle is holstered.
J MAINTENANCE
1
2
3
PERIODICALLY CHECK THE CORREC T OPERATION OF THE AUTOMATIC
STOP DEVICE
IF FITTED, IT IS BEST TO PERIODICALLY CHECK THE FILTER AND CLEAN
IT EVERY 1000 LITRES OF TRANSFER.
PERIODICALLY CHECK THE TIGHTNESS OF THE CONNECTIONS
K MALFUNCTIONS
FOREWORDTHE POSSIBLE CAUSES OF MALFUNCTION ARE MAINLY AT-
NOTICE
TRIBUTABLE TO THREE FACTORS:
1NOZZLE DIRTY IN INNER HOLE OF LIP AT END OF SPOUT
2OPERATING PRESSURE OF LIQUID TO BE DISPENSED BELOW
0.5 bar OR ABOVE 3.5 bar
3FLOW RATE TOO LOW OR TOO HIGH
Correct and regular maintenance of the nozzle and
of the system to which it is connected prevents
malfunctions and possible accidental spills of hazardous liquids.
M0302 9
EN
170
L DEMOLITION AND DISPOSAL
ForewordIf the system needs to be disposed, the parts which make it up
Disposal of
packing materials
Disposal of metal
parts
Disposal of electric
and electronic
components
Information
regarding the
environment for
clients residing
within the
European Union
Disposal of miscellaneous parts
must be delivered to companies that specialize in the recycling and
disposal of industrial waste and, in particular:
The packaging consists of biodegradable cardboard which can be
delivered to companies for normal recycling of cellulose.
Metal parts, whether paint-nished or in stainless steel, can be
consigned to scrap metal collectors.
These must be disposed of by companies that specialize in
the disposal of electronic components, in accordance with the
indications of directive 2002/96/CE (see text of directive below).
European Directive 2002/96/EC requires that all equipment marked
with this symbol on the product and/or packaging not be disposed
of together with non-dierentiated urban waste. The symbol
indicates that this product must not be disposed of together with
normal household waste. It is the responsibility of the owner to
dispose of these products as well as other electric or electronic
equipment by means of the specic refuse collection structures
indicated by the government or the local governing authorities.
Other components, such as pipes, rubber gaskets, plastic parts and
wires, must be disposed of by companies specialising in the disposal
of industrial waste.
M DIMENSIONS
396
170
19
O
10 M0302
51
1'' BSP
This page left intentionally blank
Graco Extended Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from
defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twenty-four months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed,
operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused
by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering,
or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design,
manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor
for verication of the claimed defect. If the claimed defect is veried, Graco will repair or replace free of charge any defective parts.
The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose
any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts,
labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PAR TICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no
other remedy (including, but not limited to, incidental or consequential damages for lost prots, lost sales, injury to person or
property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought
within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are
subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim
for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of
contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties
reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures
concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reects the latest product information available at the time of
publication. Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 333468 / M0302
Graco Headquarters: Minneapolis
International Oces: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
April 2014
M0302 rev.00
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.