AUTOMATIC SHUT-OFF NOZZLE FOR 333468A DIESEL EXHAUST FLUID (DEF) (ISO 22241) EN • FR • ES
NOT APPROVED FOR USE IN EXPLOSIVE ATMOSPHERES OR HAZARDOUS LOCATIONS
MODEL 127649 MAX WPR 345 kPa (3.4 bar) (50 psi)
Important Safety Instructions
EN
INDEX
A GENERAL WARNINGS 3
B FIRST AID RULES 3 B.1 WARNINGS 4
C THE DISPENSING NOZZLE 6 C.1 INTENDED USE 6
D TECHNICAL DATA 6
E INSTALLATION 6
F MODES OF OPERATION 7
G PREVENTION MISFILLING (optional) 7
H PRELIMINARY CHECK 8
I INITIAL START UP 9
J MAINTENANCE 9
K MALFUNCTIONS 9
L DEMOLITION AND DISPOSAL 10
M DIMENSIONS 10
WARRANTY 12
2 M0302
A GENERAL WARNINGS
Important precautions
Symbols used in the manual
Manual preser­vation
Reproduction rights
To ensure operator safety and to protect the pump from potential damage, workers must be fully acquainted with this instruction manual before performing any operation.
The following symbols will be used throughout the manual to highlight safety information and precautions of particular importance:
WARNING This symbol indicates safe working practices for operators and/or potentially exposed persons.
NOTICE
This symbol indicates that there is risk of damage to the equipment and/or its components.
NOTE
This symbol indicates useful information.
This manual should be complete and legible throughout. It should remain available to end users and specialist installation and maintenance technicians for consultation at any time.
All reproduction rights are reserved by Graco Inc. The text cannot be reprinted without the written permission
B FIRST AID RULES
Contact with the uid
WARNING
In the event of problems developing following EYE/SKIN CONTACT, INHALATION or INGESTION of the treated product, please refer to the SAFETY DATA SHEET of the uid handled.
EQUIPMENT MISUSE HAZARD Keep the product to be dispensed away from eyes and skin Keep the product to be dispensed out of reach of children The nozzle must only be used for the purposes for which it
was designed Using unsuitable component parts and materials could be hazardous Not checking correct part installation could be hazard­ous.
EN
M0302 3
EN
B.1 WARNINGS
The following warnings are for the setup, use, grounding, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specic risks. When these symbols appear in the body of this manual or on warn­ing labels, refer back to these Warnings. Product-specic hazard symbols and warnings not covered in this section may apear thoughout the body of this manual where applicable.
EQUIPMENT MISUSE
!
Toxic Fluid or Fumes Hazard
Misuse can cause death or serious injury
Toxic uids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
WARNING
Do not operate the unit when fatigued or un­der the inuence of drugs or alcohol. Do not exceed the maximum working pres­sure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. Use uids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read uid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer. Do not leave the work area while equipment is energized or under pressure. Turn o all equipment when equipment is not in use. Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. Do not alter or modify equipment. Altera­tions or modications may void agency ap­provals and create safety hazards. Make sure all equipment is rated and approved for the environment in which you are using it. Use equipment only for it intended purpose. Call your distributor for information. Route hoses and cables away from trac areas, sharp edges, moving parts, and hot surfaces. Do not kink or over bend hoses or use hoses to pull equipment. Keep children and animals away from work area. Comply with all applicable safety regulations.
Read MSDS’s to know the specic hazards of the uids you are using. Store hazardous uid in approved contain­ers, and dispose of it according to applicable guidelines. Prolonged contact with the treated product may cause skin irritation: always wear protec­tive gloves during dispensing.
4 M0302
Personal Protective Equipment
Wear appropriate protec­tive equipment when in the work area to help pre­vent serious injury, includ­ing eye injury, hearing loss, inhalation of toxic fumes, and burns.
This equipment includes but is not limited to: Protective eyewear, safety shoes, close-tting
clothing and hearing protection. Respirators, protective clothing, and gloves as
recommended by the uid and solvent manu­facturer.
Wear protective equipment that is suited to the operations that need to be performed and re­sistant to cleaning products.
EN
M0302 5
EN
C THE DISPENSING NOZZLE
FOREWORD DISPENSER NOZZLE FEATURING AUTOMATIC STOP DE-
C.1 INTENDED USE
P.N. 127649 WATER/UREA SOLUTION - D.E.F. - AUS 32, ACCORDING TO DIN
CONDITIONS OF USE AND ENVIRONMENTAL CONDITIONS
VICE, MADE OF NON-CONDUCTIVE PLASTIC AND DE­SIGNED TO BE USED WITH WATER/UREA SOLUTION (DEF, AUS32). ALSO COMPATIBLE WITH WATER
70070 WATER Refer to the product technical data
D TECHNICAL DATA
Part number
127649 15 l/min 45 l/min 0.9 bar 1” GAS 20 mm 3.5 bar 0.6 Kg
NOTE
Min. ow-rate
4 gpm 12 gpm 13 psi 1” BSP .787 inc 50 psi 1.3 lb
Max. ow-rate
Pressure loss at 35 l/
min (9.3 gpm)
Inlet thread with
swivel
External diameter
hose-end tting
Max. operating
pressure
The wetted materials used in this device are : stainless steel, plastic and rubber suitable for AdBlue.
Weight
E INSTALLATION
FOREWORD The automatic nozzles are supplied ready for use.
NOTICE
NOTICE
The nozzle features SWIVEL hose-end tting (complete with O-ring) useful for connecting to the supply hose. TO ENSURE PERFECT OPERATION, THE DEVICE MUST BE USED TO DISPENSE FLUIDS WITH CHARACTERISTICS FALL­ING WITHIN THE FOLLOWING PARAMETERS:
- Qmin .: 15 l/min / 4 gpm -- Qmax: 45 l/min / 12 gpm
- Pmin. : 1,5 bar / 22 psi - - Pmax: 3,5 bar / 50 psi
During installation, use adequate sealants, being careful no residues remain inside the hose. So as not to negatively affect product operation, couple the hose-end fitting with the hose without using tools such as pliers, etc. Assembly will be easier if the swivel hose-end fitting is already fitted on the nozzle. Make sure the hoses and the suction tank are with­out threading scale or residues which could dam­age the nozzle and the accessories. Apply adequate sealants on the male threads of the connections and swivels Do not use PTFE tape
NO PTFE TAPE
6 M0302
F MODES OF OPERATION
FOREWORD The main feature of these nozzles is that they are easy to
1 ASSISTED MODE
2 AUTOMATIC MODE
NOTICE
use. Two operating modes are available:
Dispense by operating the nozzle lever. To interrupt dis­pensing manually, release the lever.
Use the opening lever lock device for automatic dispens­ing. To continue dispensing after automatic stop, the lever must be fully released before proceeding to operate it again. To interrupt dispensing in manual mode, press the lever again, thereby releasing the device, and then release.
Do not use the nozzle outside the parameters indi­cated on the ”technical specifications” chart
EN
NOTE
Dispensing is automatically interrupted due to the shut-off device, which operates when the level of the liquid reaches the end of the spout.
G PREVENTION MISFILLING (optional)
PREMISE
OPERATION
NOTICE
PART NUMBER DESCRIPTION PICTURE
127652 Magnet switch misl spout
127654 Magnet adapter misl
Refuelling with the nozzle equipped with “magnet switch” is only possible in combination with the “magnet adapter” , so misfuelling into tanks is made impossible
The “magnet switch” is a xed magnetic eld within the ller necks of the nozzle. This opens the magnet switch in the spout, so it is only possible to dispense from the tank where the magnet adaptor is installed.
Nozzles equipped with “magnet switch” work only in combination with the “magnet adapter”. The “mag­net adapter” is an optional to be bought separately.
adapter (installs into DN40 ller necks only
M0302 7
EN
H PRELIMINARY CHECK
NOTICE Check the correct operation of the lock device, ac-
LOW CLIP
5 cm
CLIP
HIGH CLIP
MEDIUM
cording to the following procedure:
1 Take a graduated receptacle with a capacity of 20 litres (5
gal)
2 Begin dispensing into the receptacle, setting the lever in
the minimum ow position, until the receptacle is full.
3 Keeping the lever open, make sure the spout is sub-
merged by about 5 cm (2 inches).
4 The nozzle must stop, with a click of the lever. 5 Repeat the same operations with the lever in medium-
ow and maximum-ow position. Check the correct operation of the stop device as de­scribed above.
6 If the nozzle stops during dispensing, check and reduce
the ow.
7 If the dispensing stop device fails to operate, replace the
nozzle.
8 M0302
I INITIAL START UP
FOREWORD Only start dispensing after making sure that assembly and
WARNING
NOTICE
NOTICE
NOTICE
installation have been correctly performed.
TOXIC FLUID OR FUMES HAZARD
The faulty operation of this device could cause the spill of liquids that are hazardous for people and the envi­ronment.
It is a good practice to only operate the nozzle lever after making sure the spout has been properly in­serted in the mouth of the tank to be filled.
When using for the first time and every time the nozzle is used, following the connection of the sup­ply hose, gently operate the lever to enable the air to escape from the circuit, until normal operation is achieved. Check the correct operation of the automatic stop device once the tank is full.
EN
NOTICE
Keep fresh water in nozzle path to prevent DEF crystals from forming on nozzle end. The nozzle au­tomatic cut off may fail if crystallization plugs the nozzle orifice. The nozzle tip must be submerged in water when the nozzle is holstered.
J MAINTENANCE
1
2
3
PERIODICALLY CHECK THE CORREC T OPERATION OF THE AUTOMATIC STOP DEVICE IF FITTED, IT IS BEST TO PERIODICALLY CHECK THE FILTER AND CLEAN IT EVERY 1000 LITRES OF TRANSFER. PERIODICALLY CHECK THE TIGHTNESS OF THE CONNECTIONS
K MALFUNCTIONS
FOREWORD THE POSSIBLE CAUSES OF MALFUNCTION ARE MAINLY AT-
NOTICE
TRIBUTABLE TO THREE FACTORS:
1 NOZZLE DIRTY IN INNER HOLE OF LIP AT END OF SPOUT
2 OPERATING PRESSURE OF LIQUID TO BE DISPENSED BELOW
0.5 bar OR ABOVE 3.5 bar
3 FLOW RATE TOO LOW OR TOO HIGH
Correct and regular maintenance of the nozzle and of the system to which it is connected prevents malfunctions and possible accidental spills of haz­ardous liquids.
M0302 9
EN
170
L DEMOLITION AND DISPOSAL
Foreword If the system needs to be disposed, the parts which make it up
Disposal of packing materials
Disposal of metal parts Disposal of electric and electronic components
Information regarding the environment for clients residing within the European Union Disposal of miscel­laneous parts
must be delivered to companies that specialize in the recycling and disposal of industrial waste and, in particular: The packaging consists of biodegradable cardboard which can be delivered to companies for normal recycling of cellulose.
Metal parts, whether paint-nished or in stainless steel, can be consigned to scrap metal collectors. These must be disposed of by companies that specialize in the disposal of electronic components, in accordance with the indications of directive 2002/96/CE (see text of directive below).
European Directive 2002/96/EC requires that all equipment marked with this symbol on the product and/or packaging not be disposed of together with non-dierentiated urban waste. The symbol indicates that this product must not be disposed of together with normal household waste. It is the responsibility of the owner to dispose of these products as well as other electric or electronic equipment by means of the specic refuse collection structures indicated by the government or the local governing authorities.
Other components, such as pipes, rubber gaskets, plastic parts and wires, must be disposed of by companies specialising in the disposal of industrial waste.
M DIMENSIONS
396
170
19
O
10 M0302
51
1'' BSP
This page left intentionally blank
Graco Extended Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, ex­tended, or limited warranty published by Graco, Graco will, for a period of twenty-four months from the date of sale, repair or re­place any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incom­patibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verication of the claimed defect. If the claimed defect is veried, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PAR TICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost prots, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are
subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equip­ment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceed­ings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procé­dures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reects the latest product information available at the time of
publication. Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 333468 / M0302
Graco Headquarters: Minneapolis
International Oces: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
April 2014
M0302 rev.00
Loading...