Instructions-Parts
Beacon Tower
Diagnostic indicator for use with ProMix® 2KS and ProMix 2KE Proportioner.
For professional use only.
Not for use in explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in your proportioner installation, operation, and repair manuals.
Save these instructions.
313542D
ENG
Part No. 122193 Beacon Tower
Includes beacon tower only.
Part No. 15W034 Beacon Tower Kit
Includes beacon tower, cable, connectors, and mounting hardware.
122193 Beacon
Tower Shown
TI14039a
15W034 Beacon Tower Kit Installation
15W034 Beacon Tower Kit
Installation
NOTE: Kit 15W034 is for ProMix 2KS manual systems.
1. Remove the 3/4 in. (19 mm) knockout on top of the
EasyKey. Feed the wires through the hole and
secure the beacon (1) with jam nuts (N) on the
inside and outside of the box. See F
IG. 1.
1
N
4. Connect orange, brown, and red wires to header (5)
pins 3, 4, and 5. See F
IG. 6 on page 6.
5. To enable the optional audible alarm, connect sky
blue wire to pin 3 on header (5). See F
IG. 6 on page
6. When enabled, it will sound for all system alarms.
6. When beacon wiring is completed, insulate the end
of each unused lead wire with insulation tape.
Beacon Signals
Flashing
Signal/
Audible Description
Amber A system warning is active; verify alarm.
Red A potlife alarm exists. System goes to
Standby.
Green Not used.
Audible A system warning is active; verify alarm.
NOTE: See the ProMix 2KS operation manual for details
of the specific alarms.
TI14040a
F
IG. 1: Install Beacon on EasyKey
2. See F
IG. 4. Install the din rail (7) with two screws (8).
™
Install the header (5) on the din rail and connect the
cable (4) to J5 on the EasyKey display board.
3. Connect yellow and gray wires from beacon to the
power terminal. See F
DC
OK
+
-
OUTPUT DC
-
IG. 2.
N (-)
NC
INPUT AC
NC
L (+)
Gray
(Common)
Yellow (+24V)
TI14041a
FIG. 2: Power Terminal Connections
2 313542D