Diagnostic indicator for use with ProMix® 2KS and ProMix 2KE Proportioner.
For professional use only.
Not for use in explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in your proportioner installation, operation, and repair manuals.
Save these instructions.
313542D
ENG
Part No. 122193 Beacon Tower
Includes beacon tower only.
Part No. 15W034 Beacon Tower Kit
Includes beacon tower, cable, connectors, and mounting hardware.
122193 Beacon
Tower Shown
TI14039a
Page 2
15W034 Beacon Tower Kit Installation
15W034 Beacon Tower Kit
Installation
NOTE: Kit 15W034 is for ProMix 2KS manual systems.
1. Remove the 3/4 in. (19 mm) knockout on top of the
EasyKey. Feed the wires through the hole and
secure the beacon (1) with jam nuts (N) on the
inside and outside of the box. See F
IG. 1.
1
N
4. Connect orange, brown, and red wires to header (5)
pins 3, 4, and 5. See F
IG. 6 on page 6.
5. To enable the optional audible alarm, connect sky
blue wire to pin 3 on header (5). See F
IG. 6 on page
6. When enabled, it will sound for all system alarms.
6. When beacon wiring is completed, insulate the end
of each unused lead wire with insulation tape.
Beacon Signals
Flashing
Signal/
Audible Description
AmberA system warning is active; verify alarm.
RedA potlife alarm exists. System goes to
Standby.
GreenNot used.
Audible A system warning is active; verify alarm.
NOTE: See the ProMix 2KS operation manual for details
of the specific alarms.
TI14040a
F
IG. 1: Install Beacon on EasyKey
2. See F
IG. 4. Install the din rail (7) with two screws (8).
™
Install the header (5) on the din rail and connect the
cable (4) to J5 on the EasyKey display board.
3. Connect yellow and gray wires from beacon to the
power terminal. See F
DC
OK
+
-
OUTPUT DC
-
IG. 2.
N (-)
NC
INPUT AC
NC
L (+)
Gray
(Common)
Yellow (+24V)
TI14041a
FIG. 2: Power Terminal Connections
2313542D
Page 3
122193 Beacon Tower Installation
122193 Beacon Tower Installation
Install on a ProMix 2KS
NOTE: Beacon Tower 122193 is for ProMix 2KS auto-
matic systems (ADxxxx or RDxxxx), or manual systems
with wire harness 15W023 installed.
1. Remove the 3/4 in. (19 mm) knockout on top of the
EasyKey. Feed the wires through the hole and
secure the beacon (1) with jam nuts (N) on the
inside and outside of the box. See F
2. Connect yellow and gray wires from beacon to the
power terminal. See F
IG. 2.
3. Connect orange, brown, and red wires to header
pins 6, 7, and 8. See F
IG. 5 on page 6.
4. To enable the optional audible alarm, connect sky
blue wire to pin 6 on header. See F
When enabled, it will sound for all system alarms.
5. When beacon wiring is completed, insulate the end
of each unused lead wire with insulation tape.
IG. 1.
IG. 5 on page 6.
Install on a ProMix 2KE
1. Disconnect the existing alarm from pins 1 and 2 on
the terminal strip. See F
2. Mount the beacon near the control box and secure
with jam nuts. Feed the wires into the box.
3. Connect the yellow wire from the beacon to pin 12
on the terminal strip.
4. Connect the gray wire from the beacon to pin 2 on
the terminal strip.
5. Connect either the orange, brown, or red wire to pin
1 on the terminal strip.
6. To enable the optional audible alarm, connect sky
blue wire to pin 1 on the terminal strip. When
enabled, it will sound for all system alarms.
7. When beacon wiring is completed, insulate the end
of each unused lead wire with insulation tape.
IG. 3.
Beacon Wires Schematic
1212 14
GRAY
YELLOW
ORANGE, BROWN, OR RED
SKY BLUE
NOTE: Sky Blue wire is for
optional audible alarm.
FIG. 3. Beacon Connections in Control Box, ProMix 2KE
ti15730a
313542D3
Page 4
122193 Beacon Tower Installation
4313542D
Page 5
Parts
122193 Beacon Tower, includes item 1 only
15W034 Beacon Tower Kit, includes items 1-8
Ref DescriptionQty
1LIGHT TOWER, Part No. 122193
2CONNECTOR, terminal, female
3CONNECTOR, 10 position
4WIRE HARNESS, 3 conductor with shield;
24 in. (0.6 m)
5HEADER, 5 position, din rail mount
6CONNECTOR, 5 position
7DIN RAIL
8SCREW, machine; 6-32 x 1/4 in. (6 mm)
1
3
1
1
1
1
1
2
Parts
2, 3
Last Pin
Pin 1Pin 2
F
IG. 4: 15W034 Beacon Kit Parts
INPUT AC
OUTPUT DC
1
Mount din rail (7) in these holes,
using two screws (8).
Communications and I/O Harness 15W023 is included with Automatic Systems.
Connection points inside the dashed line are already made in the EasyKey.
POWER DISTRIBUTION
TERMINALS
-
+
DISPLAY BOARD
1
2
3
4
5
J5
6
7
8
9
10
FLOW CONTROL CAL. (BLK)
GUN TRIGGER (WHT )
DIGITAL IN COMMON (RED)
REMOTE STOP (GRN)
ALARM RESET (BRN)
ALARM OUTPUT (BLU)
DIGITAL OUTPUT COMMON (ORG)
POT LIFE (YEL)
FLOW RATE ANALOG IN (PUR)
FLOW RATE ANALOG COMMON (GRAY)
Wire Harness 15W023
1
2
3
4
5
6
7
8
9
10
NOTE: Sky Blue wire is for
optional audible alarm.
NOTE: Item 4 Wire Harness is included with Kit 15W034.
DISPLAY BOARD
2
3
4
5
J5
6
7
8
9
10
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
ALARM OUTPUT (BLK)
DIGITAL OUTPUT COMMON (WHT)
POT LIFE (RED)
NOT USED
NOT USED
4
GND
LUG
65
1
2
3
4
5
POWER DISTRIBUTION
TERMINALS
- +
(+24) YELLOW
(COM) GRAY
NOTE: Sky Blue wire is for
optional audible alarm.
(+24)
YELLOW
(COM)
ORANGE
BROWN
SKY BLUE
ORANGE
BROWN
RED
SKY BLUE
GRAY
RED
1
ALARM
1
ALARM
IG. 6: 15W034 Beacon Tower Kit Wiring Diagram
F
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 313542
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2009, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 11/2010
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.