Graco 122193, 15W034 User Manual

Page 1
Instructions-Parts
Beacon Tower
Diagnostic indicator for use with ProMix® 2KS and ProMix 2KE Proportioner. For professional use only.
Important Safety Instructions
Read all warnings and instructions in your propor­tioner installation, operation, and repair manuals. Save these instructions.
313542D
ENG
Part No. 122193 Beacon Tower
Includes beacon tower only.
Part No. 15W034 Beacon Tower Kit
Includes beacon tower, cable, connectors, and mounting hardware.
122193 Beacon
Tower Shown
TI14039a
Page 2

15W034 Beacon Tower Kit Installation

15W034 Beacon Tower Kit Installation
NOTE: Kit 15W034 is for ProMix 2KS manual systems.
1. Remove the 3/4 in. (19 mm) knockout on top of the EasyKey. Feed the wires through the hole and secure the beacon (1) with jam nuts (N) on the inside and outside of the box. See F
IG. 1.
1
N
4. Connect orange, brown, and red wires to header (5) pins 3, 4, and 5. See F
IG. 6 on page 6.
5. To enable the optional audible alarm, connect sky blue wire to pin 3 on header (5). See F
IG. 6 on page
6. When enabled, it will sound for all system alarms.
6. When beacon wiring is completed, insulate the end of each unused lead wire with insulation tape.
Beacon Signals
Flashing Signal/ Audible Description
Amber A system warning is active; verify alarm. Red A potlife alarm exists. System goes to
Standby. Green Not used. Audible A system warning is active; verify alarm.
NOTE: See the ProMix 2KS operation manual for details of the specific alarms.
TI14040a
F
IG. 1: Install Beacon on EasyKey
2. See F
IG. 4. Install the din rail (7) with two screws (8).
Install the header (5) on the din rail and connect the cable (4) to J5 on the EasyKey display board.
3. Connect yellow and gray wires from beacon to the power terminal. See F
DC OK
+
-
OUTPUT DC
-
IG. 2.
N (-)
NC
INPUT AC
NC
L (+)
Gray (Common)
Yellow (+24V)
TI14041a
FIG. 2: Power Terminal Connections
2 313542D
Page 3

122193 Beacon Tower Installation

122193 Beacon Tower Installation

Install on a ProMix 2KS

NOTE: Beacon Tower 122193 is for ProMix 2KS auto-
matic systems (ADxxxx or RDxxxx), or manual systems with wire harness 15W023 installed.
1. Remove the 3/4 in. (19 mm) knockout on top of the EasyKey. Feed the wires through the hole and secure the beacon (1) with jam nuts (N) on the inside and outside of the box. See F
2. Connect yellow and gray wires from beacon to the power terminal. See F
IG. 2.
3. Connect orange, brown, and red wires to header pins 6, 7, and 8. See F
IG. 5 on page 6.
4. To enable the optional audible alarm, connect sky blue wire to pin 6 on header. See F When enabled, it will sound for all system alarms.
5. When beacon wiring is completed, insulate the end of each unused lead wire with insulation tape.
IG. 1.
IG. 5 on page 6.

Install on a ProMix 2KE

1. Disconnect the existing alarm from pins 1 and 2 on the terminal strip. See F
2. Mount the beacon near the control box and secure with jam nuts. Feed the wires into the box.
3. Connect the yellow wire from the beacon to pin 12 on the terminal strip.
4. Connect the gray wire from the beacon to pin 2 on the terminal strip.
5. Connect either the orange, brown, or red wire to pin 1 on the terminal strip.
6. To enable the optional audible alarm, connect sky blue wire to pin 1 on the terminal strip. When enabled, it will sound for all system alarms.
7. When beacon wiring is completed, insulate the end of each unused lead wire with insulation tape.
IG. 3.
Beacon Wires Schematic
12 12 14
GRAY
YELLOW
ORANGE, BROWN, OR RED
SKY BLUE
NOTE: Sky Blue wire is for optional audible alarm.
FIG. 3. Beacon Connections in Control Box, ProMix 2KE
ti15730a
313542D 3
Page 4
122193 Beacon Tower Installation
4 313542D
Page 5

Parts

122193 Beacon Tower, includes item 1 only
15W034 Beacon Tower Kit, includes items 1-8
Ref Description Qty
1 LIGHT TOWER, Part No. 122193 2 CONNECTOR, terminal, female 3 CONNECTOR, 10 position 4 WIRE HARNESS, 3 conductor with shield;
24 in. (0.6 m) 5 HEADER, 5 position, din rail mount 6 CONNECTOR, 5 position 7 DIN RAIL 8 SCREW, machine; 6-32 x 1/4 in. (6 mm)
1 3 1 1
1 1 1 2
Parts
2, 3
Last Pin
Pin 1 Pin 2
F
IG. 4: 15W034 Beacon Kit Parts
INPUT AC
OUTPUT DC
1
Mount din rail (7) in these holes, using two screws (8).
6
TI14039a
4
TI12578a
5
TI14038a
313542D 5
Page 6

Wiring Diagrams

122193 Beacon Tower (for ProMix 2KS Automatic Systems)

Communications and I/O Harness 15W023 is included with Automatic Systems. Connection points inside the dashed line are already made in the EasyKey.
POWER DISTRIBUTION TERMINALS
-
+
DISPLAY BOARD
1 2 3 4 5
J5
6 7 8 9 10
FLOW CONTROL CAL. (BLK) GUN TRIGGER (WHT ) DIGITAL IN COMMON (RED) REMOTE STOP (GRN) ALARM RESET (BRN) ALARM OUTPUT (BLU) DIGITAL OUTPUT COMMON (ORG) POT LIFE (YEL) FLOW RATE ANALOG IN (PUR) FLOW RATE ANALOG COMMON (GRAY)
Wire Harness 15W023
1 2 3 4 5 6 7 8 9 10
NOTE: Sky Blue wire is for optional audible alarm.
F
IG. 5: 122193 Beacon Tower Wiring Diagram

15W034 Beacon Tower Kit (for ProMix 2KS Manual Systems)

NOTE: Item 4 Wire Harness is included with Kit 15W034.
DISPLAY BOARD
2 3 4 5
J5
6 7 8 9 10
NOT USED NOT USED NOT USED NOT USED NOT USED ALARM OUTPUT (BLK) DIGITAL OUTPUT COMMON (WHT) POT LIFE (RED) NOT USED NOT USED
4
GND LUG
65
1 2 3 4 5
POWER DISTRIBUTION TERMINALS
- +
(+24) YELLOW (COM) GRAY
NOTE: Sky Blue wire is for optional audible alarm.
(+24)
YELLOW
(COM)
ORANGE BROWN
SKY BLUE
ORANGE
BROWN
RED
SKY BLUE
GRAY
RED
1
ALARM
1
ALARM
IG. 6: 15W034 Beacon Tower Kit Wiring Diagram
F
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 313542
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2009, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 11/2010