( OFF on scale)
2 Sliding function switch
3 Rotary range selector switch
4 Rotary knob for mid-scale setting of the electrical zero
5 Safety connection sockets
6 Nose to open the meter
7 Battery compartment
2GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
Table of Contents
Page
1Safety Features and Safety Precautions ............................. 4
5.4Device Return and Environmentally Compatible Disposal ................... 16
6Repair and Replacement Parts Service
DAkkS Calibration Lab
and Rental Instrument Service ......................................... 17
7Product Support ................................................................ 19
.10
GMC-I Messtechnik GmbH3
www.GlobalTestSupply.com
1Safety Features and Safety Precautions
This instrument fulfills the requirements of the applicable
EU guidelines and national regulations. We confirm this
with the CE marking. The relevant declaration of conformity
can be obtained from GMC-I Messtechnik GmbH.
The analog multimeter METRAmax 2 is manufactured in
accordance with safety regulations IEC 61010-1/
DIN EN 61010-1/VDE 0411-1. When used for its intended
purpose, the safety of the operator, as well as that of the
instrument, is assured. Their safety is however not guaranteed if the instrument is used improperly or handled carelessly. It is therefore imperative that you read the operating
instructions thoroughly and carefully before placing the
METRAmax 2 into service, and that you follow all instructions contained therein.
Observe the following safety precautions:
•The instrument may only be operated by persons who
are capable of recognizing contact hazards and taking
the appropriate safety precautions.
•Contact hazards exist anywhere, where voltages of
greater than 30 V may occur (effective value).
•Be prepared for the occurrence of unexpected voltages
at devices under test (e.g. defective devices).
For example, capacitors can be dangerously charged!
•Housing and measurement cables may not be dam-
aged, e.g. by cracks or ruptures.
•No measurements may be made with the METRAmax 2 in
electrical circuits with corona discharge (high-voltage).
•Special care is required when measurements are made
in HF electrical circuits. Dangerous pulsating voltages
may be present.
4GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
•Measurements under moist ambient conditions are not
!
allowable. Hands, shoes, floor and workplace must be
dry.
•Be absolutely certain that the measuring ranges are not
overloaded beyond their allowable capacities.
Meaning of Symbols on the Instrument
indicates EC conformity
Warning concerning a point of danger.
(Attention: observe documentation!)
This device may not be disposed of with the
trash. Further information regarding the WEEE
mark can be accessed on the Internet at
www.gossenmetrawatt.com by entering the
search term ’WEEE’.
GMC-I Messtechnik GmbH5
www.GlobalTestSupply.com
2Description
On the METRAmax 2, the measuring ranges are selected
with a sliding function switch and a rotary range selector
switch. The scale is mirror-backed.
The rugged plastic case and the spring-loaded jewel bearings of the stray-field-insensitive moving-coil movement
with core magnet protect the meter against damages in the
case of severe mechanical stress.
The electrical zero of the pointer can be positioned at midscale. This allows for bipolar DC voltage and DC current
measurements regardless of the polarity.
The connection sockets are protected against accidental
contact. Both the special test leads with contact-protected
connection plugs and all test leads with commercial
banana plugs (4 mm diameter) can be used.
The DC current measuring ranges can be expanded by
means of a shunt (e.g. 10 A/100 mV).
The meter is of service-friendly design.
6GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
3Operation
Attention!
!
Note
3.1 Initial Start-up
3.1.1 Connecting the Battery
The battery compartment (7) contains a 9-V battery (IEC
6F22) which is not connected. To connect the battery, it is
required to remove the lower part of the case. For this purpose, press the nose (6) on the front of the meter inwards,
using an adequate tool. Securely connect the battery contacts to the battery clip located in the battery compartment. Ensure reliable contact making. Replace the lower
part of the case and press the two parts together until they
engage.
Both measurement cables must be disconnected
from the measuring circuit before opening the
meter!
The integrated battery switches off automatically
after 45 minutes. Switching off and on again of the
sliding function switch activates the power supply.
3.1.2 Checking the Mechanical Zero
The METRAmax 2 must not be connected when checking
the mechanical zero.
➭ Set the sliding function switch (2) to the "0" position
➭ Place the METRAmax 2 in a horizontal position
➭ The pointer must be located exactly above the line
marked " OFF"
GMC-I Messtechnik GmbH7
www.GlobalTestSupply.com
➭ Correct the deviation by means of the adjustment
screw 1 on the bottom of the case using a screwdriver,
if required.
3.1.3 Checking the Electrical Zero
➭ Set the sliding function switch (2) to the position,
select the measuring range
➭ The pointer must rest exactly above the line for the zero
at mid-scale
➭ Correct deviations by means of the rotary knob (4), if
required
3.1.4 Battery Test
➭ Set the sliding function switch (2) to the " " position
➭ Set the rotary range selector switch (3) to the " "
position
➭ The pointer must travel into the battery test section
marked " "
If the pointer no longer travels into the battery test section,
or if there is an instable indication, the battery is exhausted.
It must be replaced with a new one (see chapter 5.1 on
page 16, Battery Replacement).
8GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
3.2 Voltage Measurement
+
3.2.1 DC Voltage Measurement
Operating Mode: Electrical Zero at the Left
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector (3) to the corresponding
measuring range position:
V 300 V ... 100 mV
➭ Connect the METRAmax 2
➭ Read the measured value: black scale
Operating Mode: Electrical Zero at Mid-scale
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector (3) to the corresponding
measuring range position: V 300 V ... 100 mV
➭ Check that the pointer rests at mid-scale, see chapter
3.1.3 on page 8
➭ Connect the METRAmax 2
➭ Read the measured value: red scale +/–
GMC-I Messtechnik GmbH9
www.GlobalTestSupply.com
3.2.2 Direct AC Voltage Measurement up to 300 V
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector switch (3) to the corre-
sponding measuring range: V 300 V ... 3 V
➭ Connect the METRAmax 2
➭ Read the measured value: black scale
To keep the influence of the frequency as low as possible,
the connection socket " " should be connected to the
ground potential as directly as possible or to lowest point
with respect to ground.
3.2.3
AC Voltage Measurement with Superimposed DC Voltage
Component
The DC voltage component, such as occurs with an amplifier output stage, for example, can be cut off by means of a
capacitor (recommended value: 4.7 μF/630 V). In this case,
the additional service error is smaller than 0.2% at a measuring frequency of 50 Hz. The measuring procedure corresponds to the one described above.
10GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
The DC component can be determined same as with DC
Attention!
!
+
voltage measurement.
To protect the meter against overload, the selected mea-
suring range must always be higher than the DC voltage
component determined at first.
Both voltage components must be tested before
switching to a lower measureing range.
3.3 Current Measurement
For all current measurements, connect the METRAmax 2 in
series with the consumer in the line having the lower potential to ground.
3.3.1 Direct DC Current Measurement
Operating Mode: Electrical Zero at the Left
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector switch (3) to the corre-
sponding measuring range: A 3 A...100 μA
➭ Connect the METRAmax 2
➭ Read the measured value: black scale
GMC-I Messtechnik GmbH11
www.GlobalTestSupply.com
Operating Mode: Electrical Zero at Mid-scale
+
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector switch (3) to the corre-
sponding measuring range: A 3 A...100 μA
➭ Check that the pointer rests at mid-scale, see chapter
3.1.3 on page 8
➭ Connect the METRAmax 2 according to the wiring dia-
gram
➭ Read the measured value: red scale +/–
3.3.2 DC Current Measurement via Shunts
The accuracy of the measurement is influenced by the
measuring error of the shunt.
Operating Mode: Electrical Zero at the Left
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector switch (3) to the following
position: V 100 V
➭ Connect the METRAmax 2
➭ Read the measured value: black scale
12GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
Operating Mode: Electrical Zero at Mid-scale
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector switch (3) to the following
position: V 100 mV
➭ Check that the pointer rests at mid-scale, see chapter
3.1.3 on page 8
➭ Connect the METRAmax 2
➭ Read the measured value: red scale +/–
3.3.3 AC Current Measurement
➭ Set the sliding function switch (2) to the position
➭ Set the rotary range selector switch (3) to the corre-
sponding measuring range: A 3 A...100 μA
➭ Connect the METRAmax 2
➭ Read the measured value: black scale
3.4 End of Measurement
When no measurements are made, the sliding function
switch (2) should always be set to "0" to conserve the battery life.
GMC-I Messtechnik GmbH13
www.GlobalTestSupply.com
4Characteristic Values
Measuring Ranges
DC and AC voltage Internal resistance DC and AC voltage Voltage drop
100 mV10 MΩ100 μA /55 mV
300 mV10 MΩ1mA /55mV
1V10MΩ10 mA /55 mV
3V /10MΩ1MΩ100 mA /55 mV
10 V /10 MΩ1MΩ 1A /53mV
30 V /10 MΩ1MΩ3A /51mV
100 V /10 MΩ1MΩ
300 V /10 MΩ1MΩ
Influence Quantities and Nominal Ranges of Use
Temperature
in the range 0 ... +40 ºC± 2%/10 K for
under reference conditions Class 2 for , class 3 for
Reference Conditions
Ambient temperature+23 ºC ± 2K
Position of usehorizontal
Frequency50 ... 60 Hz
±
2.5 % in the range 30 Hz ... 1.5 kHz
± 5% in the range 1.5kHz...3kHz
Moving-coil mechanism with core magnet
87 mm in the range V, A, 0 ... 3/10
red scale: 62 mm
in the range V, A, -10/-3 ... 0 ... +3/+10
14GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
Waveshapesinusoidal
Ambient Conditions
Storage temperatures–25 ... 65 °C (without batteries)
Relative humidity
max. 75%, no condensation allowed
Power Supply
Battery9 V flat cell battery, IEC 6 L R61
Overload Protection
(IEC 6F22), automatic battery switchoff after 45 minutes
Fuse F3,15 H/250 V per
DIN VDE 0820 part 22/EN 60127-2
protects the electrical circuits against
overload. The measuring mechanism is protected by 2 diodes in
inverse-parallel connection.
Electrical Safety
Protection classII per IEC 61010-1/DIN EN 61010-1/
Measuring category300 V CAT II I
Nominal voltage300 V
Contamination degree2
Test voltage3.7 kV∼EMCElectromagnetic Compatibility
Interference emission/immunity
VDE 0411-1
EN 61326-1
Mechanical Design
ProtectionHousing IP50, terminals IP20
IP XY
st
(1
digit X)
Dimensions100 mm x 140 mm x 35 mm
Weightapprox. 0.3 kg
Protection against
foreign object entry
2≥ 12.5 mm dia.0not protected
5dust protected0not protected
Extract from table on the meaning of
IP codes
IP XY
(2nd digit Y)
Protection against the
penetration of water
GMC-I Messtechnik GmbH15
www.GlobalTestSupply.com
5Maintenance
5.1 Battery Replacement
When a battery test reveals that the pointer no longer travels into the battery test section marked " ", the battery must be replaced. Replace the exhausted battery with
a new 9-V flat cell battery according to IEC 6 L R61
(IEC 6F 22). Remove the lower part of the case as
described in chapter 3.1.1 on page 7.
5.2 Fuse Replacement
Remove the case as described in chapter 3.1.1 on page 7.
The fuse holders are soldered to the circuit board.
5.3 Cleaning
The meter may only be cleaned with a soft cloth or brush.
Possible static charges of the glass pane can be eliminated
by means of an antistatic agent or a moist cloth.
5.4 Device Return and Environmentally Compatible Disposal
The METRAmax 2 is a category 9 product (monitoring and
control instrument) in accordance with ElektroG (German
Electrical and Electronic Device Law). This device is subject
to the RoHS directive. Furthermore, we make reference to
the fact that the current status in this regard can be
by entering the search term WEEE.
We identify our electrical and electronic devices in
accordance with WEEE 2012/19/EU and ElektroG with the symbol shown to the right per
DINEN50419.
These devices may not be disposed with the trash. Please
contact our service department regarding the return of old
devices, see chapter 6 on page 17.
16GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
6Repair and Replacement Parts Service
DAkkS Calibration Lab *
and Rental Instrument Service
When you need service, please contact:
GMC-I Service GmbH
Service Center
9
This address is only valid in Germany.
Please contact our representatives or subsidiaries for service in other countries.
* DAkkS Calibration Laboratory
for Electrical Quantities
accredited per DIN EN ISO/IEC 17025:2005
Accredited measured quantities: direct voltage, direct current values, DC
resistance, alternating voltage, alternating current values, AC active
power, AC apparent power, DC power, capacitance, frequency and temperature
Competent Partner
GMC-I Messtechnik GmbH is certified in accordance with
DIN EN ISO 9001:2008.
Our DAkkS calibration laboratory is accredited by the Deutsche Akkreditierungsstelle GmbH (National accreditation
body for the Republic of Germany) in accordance with
DIN EN ISO/IEC 17025:2005 under registration number DK-15080-01-01.
D-K-15080-01-01
GMC-I Messtechnik GmbH17
www.GlobalTestSupply.com
We offer a complete range of expertise in the field of
metrology: from test reports and proprietary calibration certifi-cates right on up to DAkkS calibration certificates.
Our spectrum of offerings is rounded out with free test equipment management.
An on-site DAkkS calibration station is an integral part of our
service department. If errors are discovered during calibration, our specialized personnel are capable of completing
repairs using original replacement parts.
As a full service calibration laboratory, we can calibrate
instruments from other manufacturers as well.
18GMC-I Messtechnik GmbH
www.GlobalTestSupply.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.