Dear buyer, we thank you for purchase of our product.
PRIOR TO INSTALLATION AND FIRST USE, PLEASE CAREFULLY READ THESE
GB
INSTRUCTIONS
This water heater has been manufactured in compliance with the relevant standards
and tested by the relevant authorities as indicated by the Safety Certicate and the
Electromagnetic Compatibility Certicate. Its basic technical properties are stated upon the
nameplate, glued between the connection pipes. The water heater may be connected to
water and electric power supply only by a qualied specialist. The reach in its inside due to
the repair or removal of limestone and checking and replacement of anti-corrosion protection
anode may be performed only by an authorised service workshop.
BUILDING-IN
The water heater shall be built as close as possible to the outlets. It has to be tted to the wall
using appropriate rag bolts with minimum diameter of 8 mm. The walls with great portability
must be at place where the water heater shall hanged up be suitably reinforced. Due the
universal construction the waterheater it can be xed vertically on the wall or horizontally on
the wall (output pipes must be on the left).
TECHNICAL PROPERTIES OF THE APPLIANCE
TypeGB 50GB 80GB 100GB 120GB 150
ModelGBFU50/V6GBFU80/V6GBFU100/V6GBFU120/V6GBFU150/V6
Volume [l]5080100120150
Rated pressure [MPa]0,6
Weight / Filled with water [kg]24/7430/11034/13438/15841/191
Anti-corrosion protection of tankEnameled / Mg Anode
Power of electrical heater [ W ]2000
Number and power of heating elements
[ W ]
Connection voltage [V~]230
Protection classI
Degree of protectionIP 25
Heating time to 75°C
Quantity of mixed water at 40°C [l]96/80151/130199/174238/210296/260
Energy consumption
Inlet and outlet of water are on the water heater pipes marked with colour. The supply of cold
water is marked with blue, the outlet of warm water is marked with red. The water heater can
be connected to the water supply in two manners. Closed pressure system of connection
enables the outlet of water on several outlet spots, non-pressure system enables only one
outlet point. With regard to the system of connection chosen, also the suitable mixing taps
must be purchased. By open non-pressure system it must before the water heater a non-
return valve be built-in preventing the running of water of the tank if in the network the
water runs short. By this system of connection, the cross-ow mixing tap must be used. In
the water heater, due to the heating the volume of water is increasing, which causes the
dropping of water of the mixing tap pipe. By strong squeezing of knob of the mixing tap the
dropping of water can not be prevented, but the mixing tap can only be damaged.
By closed pressure system of connection on the outlet spots the pressure mixing tap must
be used. For safety reasons the supply pipe must be tted with a return safety valve or
alternatively, a valve of the safety class that prevents the pressure in the tank from exceeding
the nominal pressure by more than 0.1 MPa.
The heating of water in the heater causes the pressure in the tank to increase to the level set
by the safety valve. As the water cannot return to the water supply system, this can result in
the dripping from the outlet of the safety valve. The drip can be piped to the drain by installing
a catching unit just below the safety valve. The drain installed below the safety valve outlet
must be piped down vertically and located in the environment that is free from the onset of
freezing conditions. In case the existing plumbing does not enable you to pipe the dripping
water from the return safety valve into the drain, you can avoid the dripping by installing a
3-litre expansion tank on the inlet water pipe of the boiler.
You should ensure that the return safety valve is functioning properly by checking it on a
regular basis i.e. every 14 days. To check the valve, you should open the outlet of the return
safety valve by turning the handle or unscrewing the nut of the valve (depending on the type
of the valve). The valve is operating properly if the water comes out of the nozzle when the
outlet is open.
GB
5
GB
Closed (pressure) system Open (non-pressure) system
Legend: 1- Safety valve 6- Checking tting
2- Test valve 7- Funnel with outlet connection
3- Non-return valve
4- Pressure reduction valve H - Cold water
5- Closing valve T - Hot water
Between the water heater and non-return valve no closing valve may be built-in
because it would disable the operation of non-return safety valve.
The water heater may be connected to the water supply in the house without reduction valve
if the pressure in the network is lower than 0.5 MPa If the pressure in the network surpasses
1.0 MPa, two reduction valves must be built-in, one after another.
Prior to the electric connection, the water heater must mandatorily be lled with water. By
rst lling the tap for the hot water upon the mixing tap must be opened. When the heater is
lled with water, the water starts to run through the outlet pipe of the mixing tap.
CONNECTION OF THE WATER HEATER TO THE ELECTRIC NETWORK
Prior to the connection to electric network in the water heater the connecting cable must be
built-in, for it the plate must be removed inserted in the front side of the plastic cover. The
plate is released so that in the slot between inserting plate and protecting cover at rst at
the knob of thermostat and than on the side opposite the knob, cautiously a screwdriver is
pushed. When the plate is removed from both sides, it can be removed by hand. In order
to take off the protecting plastic cover, also the thermostat knob must be removed and both
xing screws screwed off. The replacement of protecting plastic cover is done in reversed
order.
The connection of the water heater to the electric network must be performed according to
standards for electric installation. Because the water heater has no component which would
permanently separate it from the electric network, upon the cable connection between it
and permanent installation a switch must be installed which breaks both power supply poles
having between the opened contacts a gap at least 3 mm wide.
CAUTION: Prior to each reach in the inner of the water heater it must absolutely be
disconnected from the electric network!