Goodman PCK024-1F, PCK030-1F, PCK036-1F, PCK036-3F, PCK042-1F REPAIR PARTS

...
PRODUCT SPECIFICATIONS
PCK SERIES
10 SEER
Packaged
Air Conditioner
2 to 5 Ton
Cooling Capacity: 23,200 - 58,000 BTUH
C
The PCK packaged air conditioner
allows for side-by-side ground-level or
rooftop application and is approved for
manufactured or modular homes.
Standard Features
• Hermetically sealed compressor with internal relief valve
• Totally enclosed, permanently lubricated condenser fan motor
• Copper tube/aluminum fin coil
• Fully charged R-22 system
• Liquid line filter drier
• Quiet-operating top grille condenser discharge
• Fully insulated air handling compartment
• Bottom pan rails elevate the unit above the slab
• Convenient access panels
Cabinet Construction
• Powder-paint finish with 500-hour salt spray approval
• Fully insulated air handling compartment
• Convenient access panels
• When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for hurricane-type winds
Accessories
• Roof Curb
• Downflow Plenum (includes filter rack)
• Manual Fresh Air Damper (to be used with Downflow Plenum)
• Economizer (to be used with Downflow Plenum)
• Louvered Panel Kit (LPAK-00A, LPAK-01A, LPAK-02A)
• Square-to-Round Duct Converter for Round Duct applications (horizontal and downflow)
• Elbow and Flashing Downflow Kit
• Room Thermostat (CHT18-60)
• Outdoor Thermostat (OT18-60)
• Heat Kit from 5 to 20 kW with plug-in connection
Accessory Heat Kit Features
• Controlled by sequencers for better temperature control (single-phase units only)
• Control circuitry arranged to readily permit staging (HK10, 15, 20-1 only)
• Primary/secondary limit protection
• Rust-resistant nickel chromium heating elements
• Factory-installed circuit breakers on certain models (see Electrical Data)
SS-278D
www.goodmanmfg.com
1/05
Supercedes 8/04
PRODUCT SPECIFICATIONS
Nomenclature
PCK 024 -1 F
Revision
Electrical Designator
1 - 208/230 VAC, 1 Ph, 60 Hz 3 - 208/230 VAC, 3 Ph, 60 Hz 4 - 460 VAC, 3 Ph, 60 Hz
Nominal Capacity
024 - 24,000 BTUH 030 - 30,000 BTUH 036 - 36,000 BTUH 042 - 42,000 BTUH 048 - 48,000 BTUH 060 - 60,000 BTUH
Unit Type
Packaged Air Conditioner (2nd Generation)
All Units Are Direct Drive
Specifications
PCK024-1F PCK030-1F PCK036-1F PCK036-3F PCK042-1F Total Cooling (BTUH) Sensible Cooling (BTUH)
1
SEER
2
EER
a
Sound Rating (bels) Indoor Blower Type Size (D” x W”) Motor Horsepower Evaporator Coil Face Area (ft Fins per Inch No. of Rows Outdoor Fan Fan Diameter Motor Horsepower Condenser Coil Face Area (ft Fins per Inch No. of Rows Electrical Ph Volts Compressor RLA Compressor LRA Indoor Blower FLA Outdoor Blower FLA Minimum Circuit Ampacity Maximum Overcurrent Protection Net Weight (pounds) 240 245 265 265 335 Shipping Weight (pounds) 255 260 280 280 350
(1) Certified per ARI 210 (2) BTU/Watt @ 80/67 °F inside - 95 °F outside air Note - May use fuses or HACR type Circuit Breakers of the same size as noted.
2
)
2
)
23,200 16,800
10.0
9.0
8.0
DD
9 x 6
1/5
3.33 14
2
18” 1/6
12.1 19
1
1
208/230
9.8
56.0
1.7
1.0
15.0 20
28,400 20,600
10.0
9.0
8.0
DD
9 x 6
1/3
3.33 14
2
18” 1/6
12.1 19
1
1
208/230
13.8
75.0
2.6
1.0
20.9 30
35,000 25,600
10.0
9.0
8.0
DD
9 x 6
1/3
3.33 14
3
18” 1/6
12.1 19
1
1
208/230
16.2
96.0
2.6
1.0
23.9 40
35,000 25,600
10.0
9.0
8.0
DD
9 x 6
1/3
3.33 14
3
18” 1/6
12.1 19
1
3
208/230
10.3
75.0
2.6
1.0
16.5 20
208/230
42,000 32,000
10.0
9.0
8.4
DD
9 x 8
1/3
5.25 14
3
22” 1/4
14.7 19
1
1
17.1
105.0
2.6
1.6
25.6 40
2
PRODUCT SPECIFICATIONS
Specifications (cont.)
PCK048-1F PCK048-3F PCK060-1F PCK060-3F PCK060-4F Total Cooling (BTUH) Sensible Cooling (BTUH)
1
SEER
2
EER
a
Sound Rating (bels) Indoor Blower Type Size (D” x W”) Motor Horsepower Evaporator Coil Face Area (ft Fins per Inch No. of Rows Outdoor Fan Fan Diameter Motor Horsepower Condenser Coil Face Area (ft Fins per Inch No. of Rows Electrical Ph Volts Compressor RLA Compressor LRA Indoor Blower FLA Outdoor Blower FLA Minimum Circuit Ampacity Maximum Overcurrent Protection Net Weight (pounds) 340 340 350 350 350 Shipping Weight (pounds) 365 365 375 375 375
(1) Certified per ARI 210 (2) BTU/Watt @ 80/67 °F inside - 95 °F outside air Note - May use fuses or HACR type Circuit Breakers of the same size as noted.
2
)
2
)
46,000 35,800
10.0
9.0
8.4
DD
10 x 8
1/2
5.75 14
4
22” 1/4
14.7 19
1
1
208/230
18.3
102.0
3.6
1.6
28.2 40
46,000 35,800
10.0
9.0
8.4
DD
10 x 8
1/2
5.75 14
4
22” 1/4
14.7 19
1
3
208/230
12.6
91.0
3.6
1.6
21.0 30
58,000 43,500
10.0
9.0
8.4
DD
10 x 8
3/4
6.22 14
4
22” 1/3
16.2 19
1
1
208/230
25.0
170.0
5.1
2.5
38.9 60
58,000 43,500
10.0
9.0
8.4
DD
10 x 8
3/4
6.22 14
4
22” 1/3
16.2 19
1
3
208/230
15.5
124.0
5.1
2.5
27.0 40
58,000 43,500
10.0
9.0
8.4
DD
10 x 8
3/4
6.22 14
4
22” 1/3
16.2 19
1
3
460
7.5
59.6
2.2
1.2
12.8 20
3