This manual is to be used by qualified, professionally trained HVAC technicians only.
Goodman does not assume any responsibility for property damage or personal injury
due to improper service procedures or services performed by an unqualified person.
®
is a registered trademark of Maytag Corporation or its related companies
and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
LINE VOLT AGE WIRING.............................................................................................................................................. 17
SYSTEM OPERATION ...................................................................................................................... 18
HEA TING CYCLE......................................................................................................................................................... 18
FAN OPERA TION ........................................................................................................................................................ 19
ONCE A MONTH ......................................................................................................................................................... 22
ONCE A YEAR............................................................................................................................................................. 22
TEST EQUIPMENT...................................................................................................................................................... 22
S-4 CHECKING TRANSFORMER AND CONTROL CIRCUIT ....................................................................................... 25
S-7 CHECKING CONT ACTOR AND/OR RELA YS........................................................................................................ 25
S-8 CHECKING CONT ACTOR CONT ACTS .................................................................................................................. 26
S-9 CHECKING FAN RELA Y CONTACTS..................................................................................................................... 26
S-11 CHECKING LOSS OF CHARGE PROTECT OR ................................................................................................... 27
S-15 CHECKING CAP ACITOR ..................................................................................................................................... 27
S-17A RESIST ANCE TEST .......................................................................................................................................... 30
S-17B GROUND TEST ................................................................................................................................................. 30
2
INDEX
S-17D Operation T est ................................................................................................................................................. 31
S-18 TESTING CRANKCASE HEA TER ........................................................................................................................ 31
S-18A CHECKING CRANKCASE HEA TER THERMOST AT........................................................................................... 31
S-21 CHECKING REVERSING V ALVE AND SOLENOID .............................................................................................. 31
S-24 TESTING DEFROST CONTROL .......................................................................................................................... 32
S-50 CHECKING HEA TER LIMIT CONTROL(S) ........................................................................................................... 32
S-52 CHECKING HEA TER ELEMENTS ........................................................................................................................ 32
S-102 EV ACUA TION..................................................................................................................................................... 33
S-108 SUPERHEA T ...................................................................................................................................................... 35
OT18-60A OUTDOOR THERMOST A T ......................................................................................................................... 42
OT18-60A OUTDOOR THERMOST A T ......................................................................................................................... 43
SINGLE PHASE HKR** HEA T KITS ............................................................................................................................ 44
SPK* - SINGLE POINT WIRING KIT ......................................................................................................................... 46
3
IMPORTANT INFORMATION
Pride and workmanship go into every product to provide our customers with quality products. It is possible, however,
that during its lifetime a product may require service. Products should be serviced only by a qualified service technician
who is familiar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testing
instruments and the appropriate service manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE
SERVICE MANUAL BEFORE BEGINNING REPAIRS.
IMPORTANT NOTICES FOR CONSUMERS AND SERVICERS
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
WARNING
T
HIS UNIT SHOULD NOT BE CONNECTED TO. OR USED IN CONJUNCTION WITH, ANY DEVI CES THAT ARE NOT DESIGN CERTIFI ED FOR US E WITH THI S UNIT OR HAV E NOT BEEN
TESTED AND APPROVED BY
FROM THE USE OF DEVICES THAT HAVE NOT BEE N APPROVED OR CERTIFED BY
GOODMAN. SERIOUS PROPERTY DAMAGE OR PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/OR HAZARDOUS CONDITI ONS MAY RESULT
GOODM AN .
WARNING
T
O PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,
DO NOT STORE COMBUSTIBLE MATE RIALS OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.
WARNING
GOODMAN WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES.
IF YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH
MAY RESU LT.
MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERV ICE HEATING AND AIR CONDITIONING EQUIPMENT.
To locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased this
product. For further assistance, please contact:
CONSUMER INFORMA TION LINE
GOODMAN® BRAND PRODUCTS
TOLL FREE 1-877-254-4729 (U.S. only)
email us at: customerservice@goodmanmfg.com
fax us at: (713) 856-1821
(Not a technical assistance line for dealers.)
Outside the U.S., call 1-713-861-2500
(Not a technical assistance line for dealers.)
Your telephone company will bill you for the call.
4
IMPORTANT INFORMATION
SAFE REFRIGERANT HANDLING
While these items will not cover every conceivable situation, they should serve as a useful guide.
WARNING
REFRIGERANTS ARE H EAVIER T HAN AIR. THEY CAN "PUS H OUT" THE
OXYGEN IN YOUR LUNGS OR IN ANY ENCLOSED SPACE.
POSSI BLE DIFFI CULTY IN BRE ATHIN G OR DEATH:
EVER PURGE REFRIGERANT INTO AN ENCLOSED ROOM OR SPACE. BY
•
N
LAW, ALL REFRIGERANTS MUST BE RECLAIMED.
IF AN INDOOR LEAK IS SUSPECTED, THOROUGHLY VENTIL ATE THE AREA
•
BEFORE BEGINNING WORK.
IQUID REFRIGERANT CAN BE VERY COLD. TO AVOID POSSIBLE FROST-
•
L
BITE OR BL INDNESS, AVOID CONTACT W ITH REFR IGERANT AND WEAR
I
GLOVES AND GOGGLES.
SKIN OR EYES, SEEK MEDICAL HELP IMMEDIATELY.
A
LWAYS FOLLOW
•
AS POIS ONOUS GA S WILL BE PRODUC ED.
F LIQUID REFRIGERANT DOES CONTACT YOUR
EPA
REGULATIONS. NEVER BURN REFRIGERANT,
O AVO ID
T
WARNING
TO AVOID POSSIBLE EXPLOSION:
EVER APPLY FLAME OR S TEAM TO A REFRIGERAN T CYLINDER. IF YOU
•
N
MUST HEAT A CYLINDE R FOR FASTER CHARGING , PARTIALLY IMMERSE
IT IN WARM WATER.
NEVER FILL A CYLINDE R MORE THAN 80% FULL OF LIQUID REFRIGERANT.
•
NEVER ADD ANYTHING OTHER THAN R-22 TO AN R-22 CYLINDER OR
•
R-410A TO AN R-410A CYLINDER . THE SERVICE EQUIPMENT USED MUST
BE LISTED OR CERTIF IED FOR THE TYPE OF REF RIGERANT USED.
TORE CYLINDERS IN A CO OL, DRY PLACE. NEVER USE A CYLIND ER
•
S
AS A PLATFORM OR A ROLLER.
WARNING
TO AVOID POSSIBLE EXPLOSION, USE ONLY RETURNABLE (NOT DISPOSABLE)
SERVICE CYLINDERS WHEN REMOVING REFRIGERANT FROM A SYSTEM.
•
ENSURE THE CYLINDER IS FREE OF DAMAGE WHICH COULD LEAD TO A
LEAK OR EX PLOS ION.
•
ENSURE THE HYDROST ATIC TEST DATE DOES NO T EXCEED 5 YEARS.
•
ENSURE THE PRESSURE RATING MEETS OR EXCEEDS 400 LBS.
WHEN IN DOUBT, DO NOT USE CYLINDER.
WARNING
WARNING
SYSTEM CONTAMINANTS, IMPROPER SERVICE PROCEDURE AND/OR PHYSICAL
ABUSE AFFECTING HERMETIC COMPRESSOR ELE CTRICAL TERMINALS MAY
CAUSE DANGEROUS SYSTEM VENTING.
The successful development of hermetically sealed refrigeration compressors has completely sealed the compressor's
moving parts and electric motor inside a common housing,
minimizing refrigerant leaks and the hazards sometimes associated with moving belts, pulleys or couplings.
Fundamental to the design of hermetic compressors is a
method whereby electrical current is transmitted to the compressor motor through terminal conductors which pass
through the compressor housing wall. These terminals are
sealed in a dielectric material which insulates them from the
housing and maintains the pressure tight integrity of the hermetic compressor. The terminals and their dielectric embedment are strongly constructed, but are vulnerable to careless compressor installation or maintenance procedures and
equally vulnerable to internal electrical short circuits caused
by excessive system contaminants.
T
O AVOID POSSIBLE INJURY, EXPLOSION OR DEATH, PRACTICE SAFE
HANDLING OF REFRIGERANTS.
In either of these instances, an electrical short between the
terminal and the compressor housing may result in the loss
of integrity between the terminal and its dielectric embedment. This loss may cause the terminals to be expelled,
thereby venting the vaporous and liquid contents of the compressor housing and system.
A venting compressor terminal normally presents no danger
to anyone, providing the terminal protective cover is properly
in place.
If, however, the terminal protective cover is not properly in
place, a venting terminal may discharge a combination of
(a ) hot lubricating oil and refrigerant
(b ) flammable mixture (if system is contaminated
with air)
in a stream of spray which may be dangerous to anyone in
the vicinity. Death or serious bodily injury could occur.
Under no circumstances is a hermetic compressor to be electrically energized and/or operated without having the terminal
protective cover properly in place.
See Service Section S-17 for proper servicing.
5
PRODUCT IDENTIFICATION
®
The model number is used for positive identification of component parts used in manufacturing. Please use this number when
requesting service or parts information.
is a registered trademark of Maytag Corporation or its related companies and is used under license to
Goodman Company, L.P., Houston, TX. All rights reserved.
6
PRODUCT IDENTIFICATION
MODE L # PACKAGE COOLING DE SCRIPTION
GPC1324-42H41AA
GPC1348-60H41BA
GPC1324-42H41AB
GPC1349H41AA
GPC1360H41BB
GPC1324-49H41BA
GPC1360H41C A
GPC1324-42H41AC
GPC1349H41AB
GPC1360H41BC
GPC1424-48H41AA
GPC1424-48H41AB
GPC1424-48H41BA
GPC1460H41BA
GPC1424-48H41AC
GPC1460H41AB
GPC1324H41C A
GPC1424H41C A
GPC1330-49H41CA
GPC1360H41D A
GPC1430-60H41CA
oodman® Brand or Distinctions Package Cooling -
G
13 Seer 208-230/1/60 Single -Phase Elect ric Cooling Unit with R-410A
oodman
G
®
Brand or Distinc tions
ackage Coo l ing -
P
13 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Models with 5 mm condenser coils.
G
oodman
Brand or Distinc tions
P
ackage Coo l ing -
®
13 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Models w ith aluminum evaporat or coils .
oodman
G
®
Brand or Distinc tions
ackage Coo l ing -
P
13 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Adds " T" to liquid line and re-locates t he p ressure switch on "H" series coo ling
models.
oodman® Brand or Distinctions Package Cooling -
G
14 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
oodman® Brand or Distinctions Package Cooling -
G
14 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Models with 5 mm condenser coils.
G
oodman® Brand or Distinctions Package Cooling 14 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Models w ith aluminum evaporat or coils .
oodman® Brand or Distinctions Package Cooling -
G
14 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Mode ls with 5 mm condenser coils and aluminum evaporator coils.
oodman
G
®
Brand or Distinc tions
ackage Coo l ing -
P
14 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A.
Adds " T" to liquid line and re-locates t he p ressure switch on "H" series coo ling
models.
G
oodman
®
Brand or Distinc tions
P
ackage Coo l ing 13 & 14 Seer 2 08-230/1/60 Single-Phase Electric Cooling Unit with R-410A. Two
ton model s with a Rechi c ompressor.
G
oodman
®
Brand or Distinc tions
P
ackage Coo l ing 13 & 14 Seer 2 08 -230/1/6 0 Si n gle-Phase Elec tric Cooling Unit with R-410A.
Models with Broad Ocean Digi motor.
APC1324-49H41CA
APC1360H41DA
®
mana
A
Brand or Dis tinct ions Package Cooling 13 Seer 208-230/1/60 Single -Phase Elect ric Cooling U nit wit h R-410A. New
models will fi ll gaps current ly in product line.
7
PRODUCT IDENTIFICATION
MODEL # PACKAGE HEAT PUMP DESCRIPTION
GPH1324-42H41AA
GPH1348-60H41BA
GPH1324,30,42H41AB
GPH1336H41AC
GPH1348-60H41BB
GPH1424-60H41AB
GPH1424-60H41AA
GPH1324-42H41AC
GPH1348-60H41BC
GPH1424-60H41AC
GPH1324-42H41BA
GPH1348-60H41CA
GPH1424-60H41BA
GPH1324-42H41CA
GPH1348H41D A
GPH1424-60H41CA
APH1324-42H41CA
G
oodman
13 Seer 208-230/1/60 Single -Phase Heat Pump with R-410A.
oodman
G
13 & 14 Seer 2 08-230/1/60 Single-Phase Heat Pump with R-410A. Models are
changing to the PCBDM133 defros t control and with the addition of the crankcase
heaters where necessary.
G
oodman® Brand or Distinctions Package Hea t Pump -
14 Seer 208-230/1/60 Single -Phase Heat Pump with R-410A.
G
oodman® Brand or Distinctions Package Hea t Pump - 13/14 Seer 208-230/1 /60
Single-Phase H eat Pump with R -410A. Add s "T" to liquid line and re-locates t h e
pressure switch on "H " series heat pumps .
oodman® Brand or Distinctions Package Hea t Pump - 13/14 Seer 208-230/1 /60
G
Single-Phase Heat Pump w ith R-410 A. Models with Aluminum Evaporator Coils.
oodman® Brand or Distinctions Package Hea t Pump - 13/14 Seer 208-230/1 /60
G
Single-Phase Heat Pump w ith R-410 A. Models with Broad Ocean Digi motor.
A
mana
13 Seer 208-230/1/60 Single -Phase Heat Pump with R-410A. New models wil l fill
gaps cur rent ly in produc t line.
®
Brand or Distinc tions
®
Brand or Distinc tions
®
Brand or Dis tinct ions Package Hea t Pump -
P
ackage Hea t Pump -
ackage Hea t Pump -
P
APH1348-60H41DA
mana® Brand or Dis tinct ions Package Hea t Pump -
A
13 Seer 208-230/1/60 Single -Phase Heat Pump with R-410A. New models wil l fill
gaps cur rent ly in produc t line.
8
ACCESSORIES
Part NumberD escript ion
OT18-60A
OT/H E R- 60AOutdoor Thermostat with Emergency Heat Relay
HKR05A, 08, 10, CAHeater K it for all *PC/*PH (H) Ser ies
HKP15*Heater k it for *PC/ *P H13/14 (30-60) ( H) S er ies
HKP20*Heater K it for *PC/ *P H13/14 (42-60) (H) S er ies
PCCP101- 103Roof Curb
PCP101-103Downflow Plenum Kit
PCP101-103R8Downflow P lenum Kit w/ R-8 Insulation
GPCED101-103Downfl ow E c onomizer for H Ser ies Pack age Units (A/C) - To Be Used Wit h P CP101-103
GPHED101-103Downfl ow E c onomizer for H Ser ies Pack age Units (Heat P ump) - To Be Used With PCP101-103
GPCEH101-103Horizontal Economizer for H Series Package Units (A/C)
GPHEH101-103Horizontal Economizer for H Series Package Units (Heat Pump)
PCMD101-103M anual Damper - To B e Used Wit h PCP 101- 103
PCMDM101-103Motorized Damper - To Be Used With PCP101-103
GPHMD101-103Manual Damper for Horizontal Applications
SPK*Single Point Wiring Kit
SQRPCH101Square to Round Adapters 16"&14"
SQRPCH102-103Square to Round Adapters 18"&14"
SQRPC101Square to Round Adapter - For Use With P CCP 101-103 Curb 16" R ounds
SQRPC102-103Square to Round Adapt er F or Use With PCCP101-103 Curb 18" Rounds
PCFR101-103External Horizontal Filter Rac k
PCEF 101- 103Elbow & Flashing w/ R-8 Liner
CDK36Flush Mount Conc entric Duc t Kit
CDK36515Flush Mount Conc entric Duc t Kit w/ Fil ter
CDK36530Step D own Conc entric Duct Kit
CDK36535Step D own Conc entric Duct K it w/ Filt er
CDK4872Flush Mount Conc entric Duc t Kit
CDK4872515Flush Mount Conc entric Duc t Kit w/ Fil ter
CDK4872530Step D own Conc entric Duct Kit
CDK4872535Step D own Conc entric Duct K it w/ Filter
*PC/*PH[13-14]**H41*
ACCESS ORI E S * P C/*PH H SERIES
Out door T hermostat (Requir ed for heat pumps with 0° outdoor
ambient and 50% or higher relative humidit y.
GOODMAN® BRAND THERMOSTATS
CH70TGManual Changeover
CHSATGManual ChangeoverMechanical, Nonprog ra m m a ble1 Heat - 1 Cool
CHT18-60Manual Changeover
CHT90-120Manual Changeover
CHTP18-60HDManual Changeover
CT18-60Manua l Cha ngeover
Digital, Nonprogramma bl e1 Heat - 1 Cool
Mechanical, Nonprog ram m able1 Heat - 1 Cool
Mechanical, Nonprog ram m able2 Heat - 2 Cool