Goodman A-HEPA650, GHEPA650 Installation And Maintenance Instructions Manual

Page 1
INSTALLATION AND MAINTENANCE INSTRUCTIONS
MODEL A-HEPA650, GHEPA650
WHOLE-HOUSE TRUE HEPA AIR CLEANER
IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT
Features
Long-life, Cert ified True HEPA (High Efficiency Particulate Air) Filter is
99.97% efficient at removing par t icles 0. 3 m icron
Carbon VOC After Filter r em oves additional unpleasant odor s and gases (optional)
Easy-to-change filters
Heavy gauge steel cabinet and powder-coat paint finish provide rigid inst allation and durability
Powerful motor delivers 540 CFM of filter ed air
Small footprint f or easier, more convenient installation
Three air outlets f or versatility
Versatile installation can be freestanding, floor, ceiling or wall mounted
FOR QUESTIONS REGARDING INSTALLATION, OPERATION & SERVICE,
CALL THE AIR CLEANER HOTLINE TOLL-FREE
1-800-267-8305
Page 2
SAFETY CONSIDERATIONS
Read and follow instruc tions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage the HEPA Air Cleaner.
inch) and larger. This HEPA filter has m ore than 133 ft² of collection surface area.
Clean air is discharged through an 8 inch duct, back into the return air duct.
INSTALLATION
Understand the signal words WARNING and CAUTION which are present in the Owner’s Manual. WARNING and CAUTION signify a hazard which could result in property damage, personal injury or death.
WARNING
Before beginning any installation or modification, be certain that the main line electrical disconnect switch is in the OFF position. Electric shock could result. Tag disconnect switch with suitable warning labels.
Only a heating/air conditioning installer or qualified service person should install, repair, or service your Whole-House HEPA Air Cleaner.
Homeowners or untrained personnel can perform the basic maintenance functions of replacing filters.
When working on air cleaning equipment, observe precautions in the Owner’s M anual, labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves.
WHAT THE HEPA AIR CLEANER DOES
The Whole-House HEPA Air Cleaner has been designed to remove particulate such as atmospheric and household dust, coal dust, insectic ide dust, mites, pollen, mold spores, fungi, bacteria, viruses, pet dander, cooking smok e and grease, tobacc o smok e and more. It also removes odors with the Carbon Prefilter.
BENEFITS
Helps provide relief from allergies, asthma, and other respiratory illness.
Helps reduce housekeeping tim e and redecorating costs.
Provides a healthier, more comfortable environment, year-round.
HOW IT WORKS
Millions of airborne pollutants are ca rried through the return air ducts of the heating/cooling system. The HEPA Air Cleaner has been designed to be duc ted to the return air duct. A portion of this return air is by­passed through a 12 inch intake duct on the top of the unit and passes through a 2-stage filtration system.
The Activated Carbon Prefilter (activated carbon impregnated polyester filter) first removes lint and odors before they enter the HEPA filter.
Smaller particles then pass through a long-life, True HEPA (High Efficiency Particulate Air) Filter which captures 99.97% of particles 0.3 micron (1/84,000 of an
SUPPLY AIR
RETURN AIR
HEATING COOLING
SYSTEM
AIR CLEANER
HEPA
UNIT
DEFLECTOR
WARNING
This unit must be installed on the return air side of the system only. Do not connect to supply side. Do not install in a cooking ar ea or connect direc tly to any appliance.
LOCATION
The HEPA Air Cleaner should be located as close to the return air duct as possible. This allows for shorter lengths of ducting which helps keep the static pressur e lower. The unit can be adapted to mount on a wall or be suspended from the ceiling. Care should be taken to keep the unit away from an area where there is a possibility of moisture leaking on to it. Ensure there is 36 inches in front of the unit to remove the filters for cleaning or replacing.
NOTE: If the unit is going to be mounted on it’s back you must contact the distributor for special mounting kit.
GENERAL INSTALLATION STEPS
1. Remove any packaging or plastic from filters before installing. See Maintenance for instructions to remove the filters.
2. When the unit is shipped, the intake and exhaust collars are reverse m ounted to prevent damage in shipping. The intake collar must be removed and reattached with the collar ring facing out. The exhaust collar can be mounted on one of three sides of the unit with the ring out. The other two sides will be covered with the exhaust covers.
These covers must be installed for the unit to operate properly.
3. An inlet collar is provided on the unit to allow a flexible 12 inch intake duc t, f rom the cold air return, to be attached. The 12 inch intake m ust be drawn from the cold air return duct at a location that will be ahead of the clean exhaust air, that will be retur ned to the duct from the Air Cleaner.
Page 3
4. A duct adapter and a length of 12 inch flexible hose or duct is required to attach between the 12 inch intake collar and the existing cold air return duct. When running the hose, make sure that there are no kinks or sharp bends that will impede the air flow to the unit. Secure and seal the hose and connections to prevent air leakage.
5. The 8 inch exhaust collar can be conveniently mounted on one of three sides of the unit. A duct adapter and a length of 8 inch flexible hose or duct is required to attach between the exhaust collar and the existing cold air return. The exhaust hose should be attached to the return air duct, close to the furnace. The ideal location is low on the return air boot pointing at the furnace. To prevent air shear inside the duct, it is recomm ended that you install a deflector inside the boot, so the discharged air is deflected down into the boot. When running the hose, make sure that there are no kinks or sharp bends that will impede the air flow from the unit. Secure and seal the hose and connections to prevent air leakage.
6. It is im portant to maintain some distance between the intake and the exhaust openings in the return air duct. Failure to do this may result in short cycling between the intake and the clean air discharge. It is recommended you leave 10 feet between the intake and the exhaust; however, as little as 6 feet will work effectively. If the distance is sm aller than 6 feet, it is important that an air deflector is installed in the duct.
7. If outside air is introduced into the retur n air duct, either through a HRV (Heat Recovery Ventilator) or direct, it should be added to the system before the intake inlet to the Air Cleaner.
OPERATING INSTRUCTIONS
WARNING
Never use the unit without all of the filters in place.
The HEPA Air Cleaner is des igned to run continuously to provide clean, filtered air 24 hours a day. The fan on the heating/cooling system, to which the HEPA Air Cleaner is dependent on for circ ulated air, s hould be on ‘continuous’.
Note: If the system fan setting is on ‘automatic’, it is recommended the HEPA Air Cleaner be operated through an air switch or relay to turn the Air Cleaner off, when there is no system fan on.
The unit plugs into a regular 120 volt outlet and is controlled by a switch located on the rear panel, near the cord.
Note: Do not allow the cord to be placed where it may be walked on or allow anything to roll over it.
The door must be secured for the Air Cleaner to operate. All filters must be in place for the unit to operate properly.
MAINTENANCE
CAUTION
Make sure to turn Air Cleaner OFF before per f orming any maintenance or removing any components.
For efficient operation, the filters m ust be changed on a regular basis. If you notice a reduction in air flow from the system, check the filters.
1. To access the filters, turn the Air Cleaner OFF at the switch and remove the front door.
2. Release the filter hold down bar by pulling it forward one side at a time.
3. Carefully remove filters to avoid spilling of collected contaminants. Dispose of f ilter s in a plastic bag and discard with regular household trash.
4. Remove plastic from new filters bef ore installing. Discard plastic safely. Tak e car e not to damage the filters.
5. Date the replacement filter in the space provided.
6. Place the Carbon prefilter around the HEPA filter and secure with the Velcro.
7. Ensure the open end of the HEPA filter is toward the motor.
8. Replace the filter hold down bar by placing one side under the bracket on the side of the cabinet. Onc e you have one side started force the bar under the bracket on the other side of the cabinet. This insures the filter has a good seal.
9. Use genuine replacement filters only. Call the original installer for parts.
Note: When the filters are new, you may notic e a new smell from the system. This is normal and will dissipate within a few days.
Carbon Prefilter: This must be replac ed every 3 - 6 months and m ay be vacuumed between changes. Use a soft brush attachment when cleaning. If there are heavy odors in the home from cooking, smoking, painting or other sources, the filter will require changing more often.
True HEPA Filter: Replace every 2-4 years. The life of this filter depends on the amount of contaminants in the air and the frequency in which the prefilter has been changed. Renovations in the home that create wood, drywall dust or similar contaminants will shorten the life expectancy of the HEPA filter. T o improve airflow, the HEPA filter can be vacuumed between changes, preferably outdoors. Use a soft brush attachment for vacuuming this filter.
Note: Handle the HEPA filter by the frame only. The paper is fragile and a puncture or tear will reduce efficiency.
VOC After Filter (optional): This filter is positioned inside the HEPA filter, and must be replaced every 6-12 months. If there are heavy odors in the home from cooking, smoking, painting or other sources, the filter may require changing more often.
Page 4
TECHNICAL DATA
Dimensions Length
Width Height
18 in 18 in 31 in
45.7 cm
45.7 cm
78.7 cm Intake 12 in 30.5 cm Outflow 8 in 20.3 cm Unit Weight 57 lbs 25.9 kg Input Voltage 120 v 60 hz Power Consumption 215 watts Air Flow 540 cfm 918 m³/hr Power Cord 9.0 ft 2.74 m Filter Dimensions Carbon Prefilter
HEPA Filter Carbon VOC After Filter
47 x 15.5 x 0.25 in
16 (H) x 14.25 (Dia) x 2.375 in
26.63 x 15.5 x 0.5 in
119.4 x 39.4.2 x 0.63 cm
40.6 x 36.2 x 6 cm
67.6 x 39.4 x 1.3 cm Carbon Prefilter Collecting Surface Area 4.98 ft² 0.46 m² HEPA Collecting Surface Area 133 ft² 12.4 m² Carbon VOC After Filter (optional) Surface Area 2.87 ft² 0.27 m²
WHOLE-HOUSE HEPA AIR CLEANER
LIMITED FIVE (5) YEAR WARRANTY
FIVE YEAR WARRANTY - This GOODMAN product is warranted to be free from electrical and m echanical defects in material and workmanship, under norm al use and
maintenance within its listed capacity, for a period of FIVE (5) years from the date of purchase, excluding the fan/motor assembly which is warranted for ONE (1) year from the date of purchase. This warranty does not include the Carbon Prefilter, HEPA or VOC Filter . This GOODMAN product must not have been moved from the site of original installation. A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through an authori zed GOODMAN servic e dealer, provided the defective part is returned to the GOODMAN distributor prepaid. The replacement part assumes the unused portion of the warranty. Proof of Purchase and Installation must be provided. Failing this, GOODMAN MANUFACTURING COMPANY, L.P. will guarantee the unit for a period of sixty (60) months from the date of manufacture, according to the manufacturer’s records and the conditions within this warranty.
THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS incurred for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement parts.
LIMITATIONS OF WARRANTY - THE EXPRESS WARRANTIES CONTAINED HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES. IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY ARE LIMITED TO THE DURATION OF THE WARRANTY DESCRIBED HEREIN. CONSEQUENTIAL OR INCIDENTAL DAMAGES F OR THE BREACH OF ANY WARRANTY WHETHER EXPRESSED OR IM PL I ED, I NCL UDI NG BUT NO T LI MITED TO LOSSES TO PERSO NS OR PROPERTY ARISING OUT OF THE FAILURE OF THIS EQUIPMENT TO OPERATE FOR ANY REASON WHATSOEVER ARE EXCLUDED. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DI STRI BUTOR, DEALER OR O THER PERSON WHATSOEVER.
Some states do not allow limitations on how long an implied warranty lasts or the exclusions of consequential or incidental damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
GOODMAN MANUFACTURING COMPANY, L.P. WILL NOT BE RESPONSIBLE F OR:
1. Normal maintenance as outlined in the Installation And Maintenance Instructions including cleaning and/or replacement of filters.
2. Damage or repairs needed as a consequence of any misapplication, negligent handling, improper servicing, unauthorized alteration, or improper operations.
3. Damage or repairs required as a consequence of faulty installation or application by others.
4. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of electrical service.
5. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditi ons beyond the control of GOODMAN MANUFACTURING COMPANY, L.P.
6. Parts, including filters, not supplied or designated by GOODMAN M ANUFACTURING COMPANY, L.P.
7. GOODMAN MANUFACTURING COMPANY, L.P. products installed outside the continental U.S.A., Alaska, Hawaii, and Canada.
Model No. Serial No. Date Of Installation Installed By Owner’s Name & Address
RETAIN THIS CERTIFICATE WITH YOUR VALUABLE DOCUMENTS
ATTENTION INSTALLING CONTRACTOR: IF FAILURE SHOULD OCCUR, DO NOT RETURN PRODUCT TO T HE
2550 North Loop West, Suite 400, Houston, Texas 77092
FOR MORE INFORMATION, CALL THE AIR CLEANER HOTLINE TOLL FREE
DISTRIBUTOR. CALL THE TOLL-FREE HOTLINE 1-800-267-8305 FOR TECHNICAL ASSISTANCE.
GOODMAN MANUFACTURING COMPANY, L.P.
1-800-267-8305
good650.pub