Goodman AGZ040 Parts List

Replacement Parts List No. 700028500
Revision A 06/2015
Daikin
TrailBlazer
Air-Cooled Scroll Chiller
AGZ
Vintage E
Unit Revision 00
To nd your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
Contents
Parts List Revision History...............................................................................................................3
Serial Number Nonenclature ...........................................................................................................4
Unit Model Nomenclature ...........................................................................................................5 - 7
Electrical Legend ........................................................................................................................8 - 9
Unit Controls ........................................................................................................................... 10 - 11
Refrigeration Circuit
Compressor Layout Diagrams ................................................................................................. 12
Compressors
AGZ 030- 040 ...................................................................................................................13
AGZ 045- 065 ...................................................................................................................14
AGZ 070 ............................................................................................................................15
Evaporator .............................................................................................................................. 16
Evaporator Insulation ...............................................................................................................17
Liquid Line Piping .............................................................................................................18 - 19
Discharge Line Piping ..............................................................................................................20
Suction Line Piping .................................................................................................................. 21
Hot Gas Bypass Piping ............................................................................................................22
Sensor & Solenoid Valve Location Diagrams ................................................................... 23 - 24
Condenser Section
Fan Motor and Fan Deck Components & Condenser Coils ..............................................25- 26
Cabinet Components ..................................................................................................................... 27
Coil & Base Guards
Coil Grilles & Coil Louvers ....................................................................................................... 28
Base Grilles ......................................................................................................................29 - 30
Base Louvers ....................................................................................................................31 - 32
Optional Equipment ................................................................................................................33 - 36
Critical Parts List.......................................................................................................................CPL1
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 2
Parts List Revision History
Revision Date Description
New 02/2014 New A 06/2015 Pages 5-7: Updated Unit Model Nomenclature. Page 10: Added Control Box label example. Page 11: Added new page for common Unit Controls. Page 15: Corrected Ref. Numbers for all Compressors. Page 16: Updated part # for Flow Sensor, was 331796201, added Adapter. Changed footnote1 to include Kit part #. Page 24: Removed page 24 by moving content to other pages. New page 24- Corrected part #s for S01,02 Transducers, were 331764511. Corrected part #s for S03, 04 Transducers, were
331764611. Added info for Remote Evap Sensors for S00, S05, S08, S12, S13. Page 26: Corrected heading to 065-070, was 070. Pages 27-32: Updated Coil & Base Guard Kits. Pages 33-36: Added 3 new pages to include several optional kits. CPL1: Added page for Critical Parts List.
Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 3
Serial Number Nomenclature
STN U 13 05 048200
Plant Identication
STN = Staunton, VA
U = Unit
Year of Manufacture
13 = 2013 14 = 2014 15 = 2015
etc.
Sequence Number
Month of Manufacture
01 = January 02 = February 03 = March 04 = April 05 = May 06 = June 07 = July
08 = August 09 = September 10 = October 11 = November 12 = December
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 4
Unit Model Nomenclature
AGZ 030E D SE NN ST S M AL Y 27 MN N N N N NN N N Y N N LH B T L
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
Code
F N NN N NN NNNN N 0000 000 N N N N Y NNNN NN NN 000 0000 E
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Code
N DSU DPN Y NNNN NON NNNN NNN D00 D2 J S NN Y S 00
47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62
Code
1 Unit Type
AGZ = Air-Cooled Scroll Compressor Chiller
2 Unit Size & Vintage
030E - 070E = 4 Fan, 4 Compressor Units
3 Compressors
D = 2 Compressors per Circuit
4 Platform
SE = Standard Package - Std. Efciency SM = Remote Evaporator - Std. Efciency
5 Construction NN = Standard Base w/o Unit Wraps
FP= Fully Painted Base w/Wraps SN = Seismic Rated, Unpainted Base w/o Wraps SF = Seismic Rated, Fully Painted Base w/Wraps
6 Sound
ST = Standard Sound SB = Sound Reduction Compressor Blankets
7 Unit Operation
K = Standard Operation (51F - 65F LWT) S = Standard Operation (40F - 50F LWT) A = Lower Operation (34F - 39F LWT) B = Lower Operation (15F - 33F LWT)
8 Condenser Coil Fins
M = MicroChannel (standard) P = MicroChannel (Electro Fin Coating) A = Aluminum Fin, Copper Tubing B = Alum Fin w/Prefab Blackn Coat, Copper Tubing C = Copper Fin, Copper Tubing E = Alum Fin with Electron Coating, Copper Tubing F = Copper Fin w/Electron Coating, Copper Tubing
9 Compressor Starter
AL = Across the Line
10 Future
11 Voltage
12 = 208V / 60Hz / 3PH 29 = 230V / 60Hz / 3PH 46 = 380V / 60Hz / 3PH 27 = 460V / 60Hz / 3PH 37 = 575V / 60Hz / 3PH 52 = 400V / 50Hz / 3PH (De-rated 60 Hz unit)
12 Power Connection
PC = Single Pt Pwr Blk & Ckt Protection DC = Single Pt Disc Switch & Ckt Protection DH = HSCC w/Sgl Pt Disc Switch & Ckt Protection MN = Multiple Pt Pwr Blk & 1/3 Ckt Protection WN =Multiple Pt Disc Switches & 1/3 Ckt Protection
13 Phase Voltage
N = None V = Phase & Over/Under Volt Protection w/LED
14 Future
15 Control Box Ambient
N = None H = With Exhaust Fans & Vents
16 Compressor Capacitor N = None - Std.
17 Communication
NN = None LN = LonMark MN = Mod Bus BN = BACnet MSTP EN = BACnet IP NA = D-net LA = D-net & LonMark MA = D-net & Mod Bus BA = D-net & BACnet MSTP EA = D-net & BACnet IP
18 Display Options
N = On Controller Only U = Unit Remote Display
19 Ground Fault
N = None G= With Ground Fault Protection for the Unit
20 Future
21 Unit Options
N = No unit options C = 115V Convenience Outlet (Unit Supplied Power)
22 Water Flow
N = No Water Flow Indication A = Water Flow Indication on Evaporator only S = With Factory Installed Strainer B = With Factory Installed Strainer & Flow Indicator
23 Evaporator Connection
UC = Universal Connection - Facing out back LH = Left Hand Connections RH = Right Hand Connections
24 Evaporator Insulation
S = Sgl Layer Insulation to Suct Compr Tee B = Sgl Layer Insulation to Suct at each Compressor D = Dbl Layer Insul on Evap & Sgl Suct Piping
25 Unit Controls
T = Thermal Expansion Valve E = Electronic Expansion Valve
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 5
Unit Model Nomenclature
Continued
26 Fans
L = Std Low Noise Fan Motors
27 Head Pressure
F = Fantrol Only (32F Min.) D = VFD w/o Line Reactors V = VFD w/ Line Reactors B= VFD w/ Control Box Heater L = VFD w/ Line Reactor & Control Box Heater
28 Guards
N = No Cond Coil Guards, No Base Guards G = Cond Coil Wire Grilles Only L = Cond Coil Louvers Only P = No Cond Coil Guards, with Base Wire Grilles R = No Cond Coil Guards, with Base Louvers F = Cond Coil & Base Wire Grilles C = Cond Coil Louvers & Base Wire Grilles B = Cond Coils & Base Louvers
29 Tubing Options NN =Sealed Filt Drier, No Disch or Liq Valves, No HG
VN = Repl Filter Drier, w/Disch & Liq Valves, No HG NH = Sealed Filt Drier, No Disch or Liq Valves, w/HG VH = Repl Filter Drier, w/Dosch & Liq Valves, w/HG FH = Repl Filt Drier, w/Dis & Liq Valves, w/ HG Ready
30 Suction Valve
N = No valve V = With Shut-off Valve
31 Water Pump
NN = None FB = Field Pwr - 1 HP Pump Mtr, 1800 RPM FB = Field Pwr - 1.5 HP Pump Mtr, 1800 RPM FB = Field Pwr - 2 HP Pump Mtr, 1800 RPM FB = Field Pwr - 3 HP Pump Mtr, 1800 RPM FB = Field Pwr - 5 HP Pump Mtr, 1800 RPM FB = Field Pwr - 7.5 HP Pump Mtr, 1800 RPM FB = Field Pwr - 10 HP Pump Mtr, 1800 RPM UB = Unit Pwr - 1HP Pump Mtr, 1800 RPM UC = Unit Pwr - 1.5 HP Pump Mtr, 1800 RPM UD = Unit Pwr - 2 HP Pump Mtr, 1800 RPM UE = Unit Pwr - 3 HP Pump Mtr, 1800 RPM UG = Unit Pwr - 5 HP Pump Mtr, 1800 RPM UH = Unit Pwr - 7.5 HP Pump Mtr, 1800 RPM UJ = Unit Pwr - 10 HP Pump Mtr, 1800 RPM GB = Field Pwr - 1 HP Pump Mtr, 3600 RPM GC = Field Pwr - 1.5 HP Pump Mtr, 3600 RPM GD = Field Pwr - 2 HP Pump Mtr, 3600 RPM GE = Field Pwr - 3 HP Pump Mtr, 3600 RPM GG = Field Pwr - 5 HP Pump Mtr, 3600 RPM GH = Field Pwr - 7.5 HP Pump Mtr, 3600 RPM GJ = Field Pwr - 10 HP Pump Mtr, 3600 RPM VB = Unit Pwr - 1HP Pump Mtr, 3600 RPM VC = Unit Pwr - 1.5 HP Pump Mtr, 3600 RPM VD = Unit Pwr - 2 HP Pump Mtr, 3600 RPM VE = Unit Pwr - 3 HP Pump Mtr, 3600 RPM VG = Unit Pwr - 5 HP Pump Mtr, 3600 RPM VH = Unit Pwr - 7.5 HP Pump Mtr, 3600 RPM VJ = Unit Pwr - 10 HP Pump Mtr, 3600 RPM
32 Pump Type
NNNN = No Pump Package PPZS = Pump Package Air Cooled Scroll Single Pump PPZD = Pump Package Air Cooled Scroll Dual Pump
33 Pump Conn at Evap
N = No Pump Package 2 = 2.5 Inch 3 = 3.0 Inch 4 = 4.0 Inch 8 = 8.0 inch
34 Pump Flow 0000 = Determined by Rep based on conditions
35 Total Head 000 = Determined by Rep based on conditions
36 Pump Package Starter
N = No Pump Package S = Pump Package Starter V = Pump Pkg VFD Starter w/o Line Reactors R = Pump Pkg VFD Starter w/ Line Reactors
37 Pump Gauges N = No Pressure Gauges
G = Pressure Gauges
38 Pump Suction Valve N = No Pump Pkg Suction Shut-off Valve
V = With Pump Pkg Suction Shut-off Valve
39 Pump Discharge Valve N = No Pump Pkg Discharge Shut-off Valve
V = With Pump Pkg Discharge Shut-off Valve
40 Future
41 Impeller Trim NNNN = No Pumps
0000 = Impeller Size
42 Expansion Tank
N = None 14 = Factory Installed - 14 Gallons
43 Buffer Tank NN = None
44 % of Glycol
000 = None E00 = Ethylene 00 = % (ex: E30 = 30% Ethylene) P00 = Propylene 00 = % (ex: E30 = P0% Propylene)
45 Pump #
0000 = None
123456.... = With Pumps, Number determined by
Selection Input
46 Approvals
ETL AHRI ASHRAE Chicago
A ................. None .....None ........ None ........ None
B .................. With ......None .........With .......... With
C .................. With ...... With ..........With ..........With
D .................. With ......None ......... With ......... None
E .................. With ...... With ..........With ......... None
F .................. With ......None ........ None ......... With
V .................. With ...... With ......... None .........With
W ................. With ...... With ......... None ........ None
Z .................. With ......None ........ None ........None
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 6
Unit Model Nomenclature
Continued
47 CRN Evaporator
1 = CRN - British Columbia 2 = CRN - Alberta 3 = CRN - Saskatchewan 4 = CRN - Manitoba 5 = CRN - Ontario 6 = CRN - Quebec 7 = CRN - New Brunswick 8 = CRN - Nova Scotia 9 = CRN - Prince Edward Island 0 = CRN - Newfoundland U = CRN - Yukon N = CRN - No CRN required
48 Unit Start NSU = Startup by others
DSU = Domestic, startup CSU = Canadian, startup ISU = International, No startup provided
49 Standard Warranty
DPN = Domestic, 1-year std warranty - parts only CPN = Canadian, 1-year std warranty - parts only TPN = International, 1-year std warranty - parts only NON = None
50 Future
51 Extended Compressor Warranty
NNNN = None CPE1 = Compressor Only - Ext 1 year parts only CBE1 = Compressor Only - Ext 1 year parts & labor CPE2 = Compressor Only - Ext 2 year parts only CBE2 = Compressor Only - Ext 2 year parts & labor CPE3 = Compressor Only - Ext 3 year parts only CBE3 = Compressor Only - Ext 3 year parts & labor CPE4 = Compressor Only - Ext 4 year parts only CBE4 = Compressor Only - Ext 4 year parts & labor
52 First Year Labor Warranty
NON = None AC1 = Compessor Only AE1 = Entire Unit
54 Refrigerant Warranty
NNN = No Refrigerant Warranty RA1 = 1 yr. R410A refrigerant RA2 = 2 yr. R410A refrigerant RA3 = 3 yr. R410A refrigerant RA4 = 4 yr. R410A refrigerant RA5 = 5 yr. R410A refrigerant
55 Delay Warranty Start
D00 = No Additional Months D02 = 2 Additional Months D04 = 4 Additional Months D06 = 6 Additional Months D08 = 8 Additional Months D10 = 10 Additional Months D12 = 12 Additional Months
56 Field Options
S1 = Single Evap Pumps - Single Control Output D2 = Dual Evap Pumps - Dual Control Output
57 Brand Name
J = Daikin
58 Ship
S = Standard Ship R = Quick Ship
59 Restart
NN = Standard RR = Rapid Restore
60 Future
61 Unit Misc.
S = Standard Unit X = Special Unit
62 Unit Revision
00 = Original Revision
53 Extended Unit Warranty
NNNN = None EPE1 = 1 yr. Entire Unit- Parts Only EBE1 = 1 yr. Entire Unit- Parts & Labor EPE2 = 2 yr. Entire Unit- Parts Only EBE2 = 2 yr. Entire Unit- Parts & Labor EPE3 = 3 yr. Entire Unit- Parts Only EBE3 = 3 yr. Entire Unit- Parts & Labor EPE4 = 4 yr. Entire Unit.- Parts Only EBE4 = 4 yr. Entire Unit- Parts & Labor DPE1 = 1 yr. Entire Unit w/ Dual Pumps- Parts Only DBE1 = 1 yr. Entire Unit w/ Dual Pumps- Parts & Labor DPE2 = 2 yr. Entire Unit w/ Dual Pumps- Parts Only DBE2 = 2 yr. Entire Unit w/ Dual Pumps- Parts & Labor DPE3 = 3 yr. Entire Unit w/ Dual Pumps- Parts Only DBE3 = 3 yr. Entire Unit w/ Dual Pumps- Parts & Labor DPE4 = 4 yr. Entire Unit w/ Dual Pumps- Parts Only DBE4 = 4 yr. Entire Unit w/ Dual Pumps- Parts & Labor SPE1 = 1 yr. Entire Unit w/ Single Pumps- Parts Only SBE1 = 1 yr. Entire Unit w/Single Pumps- Parts & Labor SPE2 = 2 yr. Entire Unit w/ Single Pumps- Parts Only SBE2 = 2 yr. Entire Unit w/Single Pumps- Parts & Labor SPE3 = 3 yr. Entire Unit w/ Single Pumps- Parts Only SBE3 = 3 yr. Entire Unit w/Single Pumps- Parts & Labor SPE4 = 4 yr. Entire Unit w/ Single Pumps- Parts Only SBE4 = 4 yr. Entire Unit w/Single Pumps- Parts & Labor
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 7
Electrical Legend
Schematic Sym. Description Location
ABR Relay- Alarm Bell Control Box CB1- 6 Circuit Breaker- Compressor Control Box CB7 Circuit Breaker- Pump Panel Control Box CB100 Circuit Breaker Control Box CC1, 2 Circuit Controller (Controller Expansion Module) Control Box CHWR1, 2 Relay, Chiller Water Pump Control Box CR1, 3 Relay Pump Pkg. Control Box CT-GF1, 2 Current Transformer- Ground Fault Control Box DS1, 2 Disconnect- Main Control Box EEXV1, 2 Expansion Valve Controller Control Box EXV1, 2 Expansion Valve Liquid Line FAN1, 2 Control Box Exhaust Fan Control Box FLO SWT Flow Switch- Evaporator Evaporator FTB1, 2 Terminal Block- Exhaust Fans Control Box FU4, 5 Fuse- Primary, Control Transformer Control Box/Pump Pkg. CB FU6, 6A Fuse- Secondary, Control Transformer Control Box/Pump Pkg. CB FU7 Fuse- Evaporator Heater Control Box FU8 Fuse- Outlet Control Box FU11-1 to FU21-3 Fuse- Fan Circuit Control Box FU16 Fuse- Secondary, Control Transformer Control Box GF1, 2 Relay- Ground Fault Control Box GND1, 2 Ground Control Box HPR1, 2 Switch - High Pressure Control Box HTR1- 6 Heater- Compressor Compressors HTR7 Heater- Evaporator Control Box HTR8 Heater- Low Ambient Control Box Control Box LR1, 2 Line Reactor- Fan Control Box M1- 6 Contactor- Compressor/Pump Motor Control Box/Pump Pkg. CB M11- 16 Contactor- Fan Circuit #1 Control Box M21- 26 Contactor- Fan Circuit #2 Control Box MPR1, 2 Relay- Compressor Motor Protector Control Box MSP11- 26 Motor Protector- Fan/Pump Motor Control Box/Pump Pkg. CB MSP1- 4 Motor Protector- Compressor Compressors OLF 115V Outlet Control Box PD100 Fan Power Distributor Block Control Box PS1, 2 Switch- Pumpdown Control Box PVM1, 2 Phase Voltage Monitor Control Box S00 Sensor- Leaving Water Temperature Evaporator S01 Pressure Transducer- Suction Circuit #1 Suction Line S02 Pressure Transducer- Suction Circuit #2 Suction Line S03 Pressure Transducer- Discharge Circuit #1 Discharge Line S04 Pressure Transducer- Discharge Circuit # 2 Discharge Line S05 Sensor- Outside Air Temperature Control Box S08 Sensor- Entering Water Temperature Evaporator S12 Sensor- Suction Temperature Circuit #1 Suction Line S13 Sensor- Suction Temperature Circuit #2 Suction Line SN1- 6 Snubber Control Box SR1, 2, 5, 6 Relay- Solenoid Control Box
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 8
Electrical Legend, Continued
Schematic Sym. Description Location
SV1 Solenoid- Circuit #1 Liquid Line SV2 Solenoid- Circuit #2 Liquid Line SV5 Solenoid- Hot Gas Bypass Circuit #1 Hot Gas Bypass Line SV6 Solenoid- Hot Gas Bypass Circuit #2 Hot Gas Bypass Line SW1 Switch- Unit Shutoff Control Box T1 Transformer Control (120V Secondary) Control Box/Pump Pkg. CB T2- 4 Transformer Control (24V Secondary) Control Box TB1 Terminal Block (120V) Control Box/Pump Pkg. CB TB2, 5, 6 Terminal Block (24V) Control Box TB3, 4 Terminal Block, VFD Control Box TS1 Thermostat- Exhaust Fan Control Box TS2 Thermostat- Control Box Heater Control Box UC Unit Controller Control Box VFD1, 2 VFD- Fan/Pump Motor Control Box/Pump Pkg. CB
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 9
Unit Controls
For any control components not detailed on the following pages, refer to the Device ID label found inside the control panel (sample shown below) or contact Daikin Applied with the Control Box GOI number and/or the Unit GO number and Unit serial number.
GOI Number: 123456200200SWB1R01
Device ID McQuay Part # Description
CB100 193550201 Circuit Breaker 3-Pole 15A 480VAC 22kA
CB200 193550201 Circuit Breaker 3-Pole 15A 480VAC 22kA
CC1 193407501 Extension I/O Siemens 2 (15 Points)-MT3025
CC1 193409701 Connector Extension I/O Direct Connect
Device ID McQuay Part # Description
FU5 349937133 Fuse, Class CC, Time Delay, 600VAC, 15A, 200K AIC
FU5 023780231 Fuse Holder, Class CC & Midget (xfmr), 3 Pole, 30A, Ope...
FU5 349938230 Fuse Block Accessories, Fuse Puller, CC M, 30A
FU6 349937038 Fuse, Midget, Time Delay, 500VAC, 30A, 10K AIC
FU6A 349937035 Fuse, Midget, Time Delay, 500VAC, 15A, 10K AIC
FU6A 193465901 Fuse Block 2 Pole 30A 600V Midget
FU6A 349938230 Fuse Block Accessories, Fuse Puller, CC M, 30A
FU7 349937032 Fuse, Midget, Time Delay, 500VAC, 10A, 10K AIC
FU7 023780223 Fuse Holder, Midget, 1 Pole, 30A, Open Clip
FU7 349938230 Fuse Block Accessories, Fuse Puller, CC M, 30A
FU8 193429501 Fuse Glass 10 A Fast 250 VAC
FU8 193429601 Fuseholder Bussmann Panel Mount
FU8 099491629 Label Fuse Selection 250V 10A Glass
FU11 349937125 Fuse, Class CC, Time Delay, 600VAC, 6.0A, 200K AIC
FU11 349938227 Fuse Block Accessories, Fuse Cover, CC M, 30A
FU11 023780232 Fuse Holder, Class CC, 3 Pole, 30A, Open Clip
FU16 349937035 Fuse, Midget, Time Delay, 500VAC, 15A, 10K AIC
FU16 349938230 Fuse Block Accessories, Fuse Puller, CC M, 30A
FU21 349937125 Fuse, Class CC, Time Delay, 600VAC, 6.0A, 200K AIC
FU21 349938227 Fuse Block Accessories, Fuse Cover, CC M, 30A
FU21 023780232 Fuse Holder, Class CC, 3 Pole, 30A, Open Clip
GF1 193466201 Relay GE Ground Fault Panel Mount
GF1 193488601 Bracket Connector Single Ground Fault Relay AWS No
GND1 349938013 Ground Lug Brumell 2X 14ga - 2/0
GND1 193463201 Label Ground Lug Torque
HPR1 349934724 Relay, 120 VAC, 10A, DPDT
HPR1 349934822 Relay Socket, DIN Rail, Screw Terminal, 2 Pole
HPR2 349934724 Relay, 120 VAC, 10A, DPDT
Device ID McQuay Part # Description
MBX_TL 2233 "Heyco Reducer Snap Bushing 1.5"" OD 1.062"" ID"
MBX_TL 193524201 TEMPLATE, DRILLING, DOOR, SMALL, SINGLE DIS...
MPR1 349934724 Relay, 120 VAC, 10A, DPDT
MPR1 349934822 Relay Socket, DIN Rail, Screw Terminal, 2 Pole
MPR2 349934724 Relay, 120 VAC, 10A, DPDT
MPR2 349934822 Relay Socket, DIN Rail, Screw Terminal, 2 Pole
MSP1 193543403 CS MMP Class 10 Size S3 43 to 63A
MSP1 193547501 CS Link Kit Siemens MMP to Contactor Size S3
MSP1 193547301 CS MMP Type E Terminal Block Size S3
MSP1 193545801 CS MMP to Contactor Spacer Size S0
MSP2 193543307 CS MMP Class 10 Size S2 40 to 50A
MSP2 193547401 CS Link Kit Siemens MMP to Contactor Size S2
MSP2 193545801 CS MMP to Contactor Spacer Size S0
MSP3 193543307 CS MMP Class 10 Size S2 40 to 50A
MSP3 193547401 CS Link Kit Siemens MMP to Contactor Size S2
MSP3 193545801 CS MMP to Contactor Spacer Size S0
MSP4 193543403 CS MMP Class 10 Size S3 43 to 63A
MSP4 193547501 CS Link Kit Siemens MMP to Contactor Size S3
MSP4 193547301 CS MMP Type E Terminal Block Size S3
MSP4 193545801 CS MMP to Contactor Spacer Size S0
OLF 193466302 Receptacle Ground Fault Interrupter 15A
OLF 193459801 Label Switch AGZ
OLF 193463301 Bracket AGZ Outlet Cover
OLF 349964601 Label, Danger, Service Outlet
PD1 030372783 Power Block, 600V, 420A, 3 Pole, 1 x 8, Line: 600MCM-...
PD100 030372777 Power Block, 600V, 175A, 3 Pole, 1 x 6, Line: 2/0-14, Loa...
PD200 030372777 Power Block, 600V, 175A, 3 Pole, 1 x 6, Line: 2/0-14, Loa...
PS1 193429701 Terminal Flag Right Angle .250x.032 18-22 AWG Ins
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 10
Unit Controls
Ref. Description Part Qty
No. Number
CC1,2 Circuit Control Module 193407501 2
FAN1,2 Exhaust Fan, Control Box (Code 15= H) 193419103 2
GF1 Relay, Ground Fault (Code 19 = G) 193466201 1*
HPR1,2 High Pressure Relay, 120 VAC, 10A 349934724 2
HTR-8 Heater, Control Box (Code 27= B,L) 193440702 1
MPR1,2 Motor Protection Relay, 120 VAC, 10A 349934724 2
PS1,2 Pumpdown Switch 802005045 2
REM Remote Display (Code 18= U) 193408003 1
RR Rapid Restore Module (Code 59 = RR) 193407701 1
SR1,2 Relay, Liquid Line Solenoid, 10A 349934724 2
SR5,6 Relay, Hot Gas ByPass Solenoid, 10A (Code 29= NH,VH,FH) 349934724 2
SW1 Main Control Switch 802005045 1
UC Unit Controller 193407301 1 Battery for Unit Controller 193409001 1
* Qty=1 for units with Single Point Power Connection (Code 12= PC, DC, DH); Qty= 2 for Multi-Point Power Connection (Code 12= MN, WN)
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 11
Compressor Layout Diagrams
Evaporator
Refrigeration Circuit
Compressor #4
Compressor #2
Compressor #3
Compressor #1
Air-Cooled Scroll Chiller, AGZ 030-070, Vintage E, Unit. Rev 00 Rev. A 06/15 RPL 7000285/ Page 12