•Refer to Service Manual RS6612010 for installation, operation, and troubleshooting information.
•Refer to the appropriate Parts Catalog for part number information.
•Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures performed by an unqualified person.
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
*MVC960603BNAA
12345 67 8 91011121314
BrandMinor Revision
G - GoodmanA - Initial Releas
A - AmanaB - 1s t Revision
Configuration
M - Upflow/HorizontalMajor Revision
C - Downflow/HorizontalA - Initial Releas
K - Dedic at ed UpflowB - 1s t Revision
D - Dedi cate d Downflow
NOx
MotorN - Low Nox
V - Vari able S peed E CM /ComfortNet
E - Multi-Speed ECM
S - Single Speed
Gas V al veCabinet Width
M - ModulatingA - 14"
V - 2 Stage B - 17. 5"
H - Convert i ble 2 S tageC - 21"
S - Single StageD - 24.5"
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
WARNING
WARNING
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
Goodman will not be responsible
for any injury or property damage
2
Installation and repair of this unit
WARNING
WARNING
ments of an "entry level technician", at a minimum, as
specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit
without such background may result in product damage,
personal injury or death.
should be performed
dividuals meeting the require-
ONLY by in-
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by
Goodman for use with this unit.
WARNING
WARNING
als or use gasoline or other flammable liquids or vapors
in the vicinity of this appliance.
To prevent the risk of property
damage, personal injury, or death,
do not store combustible materi-
3
FURNACE SPECIFICATIONS
*MVC96
0403BNA
*MVC96
0603BNA
*MVC96
0803BNA
*MVC96
0804CNA
*MVC96
1005CNA
*MVC96
1205DNA
High Fire Input¹40,00060,00080,00080,000100,000120,000
High Fire Output¹38,40057,60076,80076,80096,000115,200
Available AC @ 0.5" ESP1.5 - 31.5 - 31.5 - 31.5 - 42 - 52 - 5
Size (D x W)10" x 8"11" x 8"11" x 8"11" x 10"11" x 10"11" x 11"
Horsepower @ 1075 RPM
½½½¾
11
SpeedVS ECMVS ECMVS ECMVS ECMVS ECMVS ECM
Filter S ize (in²)
Permanent3417316838538531,024
Disposable171366341427427512
Electrical Data
Min. Circuit Ampacity⁴7.87.87.810.614.414.4
Max. Overcurrent Device (amps)⁵151515152020
Shipping Weight (lbs)
¹NaturalGasBTU/h
²
³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
⁵
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
•
•
and noise issues.
•
may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Temperature Rise Range (°F)20 - 5035 - 6525 - 5545 - 7535 - 65
Vent Diameter³2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"
No. of Burners23456
Circulator Blower
Available AC @ 0.5" ESP1.5 - 31.5 - 31.5 - 42 - 52 - 5
Size (D x W)10" x 8"11" x 8"11" x 10"11" x 10"11" x 11"
Horsepower @ 1075 RPM
½½¾
11
SpeedVSECMVSECMVSECMVSECMVSECM
Filter Size (in²)
Permanent4885128537111,024
Disposable244256427356512
Electrical Data
Min. Circuit Ampacity⁴7.87.810.614.414.4
Max. Overcurrent Device (amps)⁵1515152020
Shipping Weight (lbs)
¹ Natural Gas BTU/h
²
³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
⁵
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
•
•
and noise issues.
•
may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility