Product Specifications
Standard Features
•Equipped with a check flowrater for heat pump and cooling operation
•Direct-drive, multi-speed motor to permit air volume variation for heating and cooling application needs
•Built-in coil with horizontal and vertical thermoplastic drain pans with secondary drains
•Rifled aluminum tubing and louvered aluminum fin coils
•Built-in filter provision
•Power supply entry at top
•Low-voltage entry on left side and top
•Transformer and blower time delay on all units
Cabinet Features
•Fully insulated steel cabinet
•Galvanized stucco finish with painted front panels
Accessories
•Pre-tested, pre-wired heat kits in 3, 5, 6, 8, 10, 15, 20 kW, single-phase models; featuring electric heat limit control, rust-resistant nickel chromium heating elements and select models with circuit breakers
•Permanent washable plastic air filters
(FIL18-32, FIL36-42, FIL48-61)
AR Series
Multi-Position Electric Air Handler
50 Hz, 1½- to 5-Ton
SS-AR50 |
www.goodmanmfg.com |
8/11 |
Supersedes 3/11
Product Specifications
Specifications
|
A24-00-2R |
A36-00-2R |
A48-00-2R |
A60-00-2R |
|
|
|
|
|
Electrical Data |
|
|
|
|
Min. Circuit Ampacity 1 |
1.1/1.1 |
1.8/1.8 |
1.8/1.8 |
4.3/4.3 |
Max. Overcurrent Protection 2 |
15/15 |
15/15 |
15/15 |
15/15 |
Min./Max. VAC |
198/264 |
198/264 |
198/264 |
198/264 |
Blower Motor |
|
|
|
|
FLA |
0.85 |
1.4 |
1.4 |
3.4 |
HP |
1/8 |
1/4 |
1/4 |
3/4 |
|
|
|
|
|
Physical Data |
|
|
|
|
Blower |
|
|
|
|
Diameter |
9½” [24.1] |
9½” [24.1] |
9½” [24.1] |
10⅝” [26.9] |
Width |
6” [15.2] |
8” [20.5] |
8” [20.5] |
10⅝” [26.9] |
Coil Drain Connect FPT |
¾” [1.9] |
¾” [1.9] |
¾” [1.9] |
¾” [1.9] |
Refrigerant Connection |
|
|
|
|
Liquid |
⅜” [.95] |
⅜” [.95] |
⅜” [.95] |
⅜” [.95] |
Suction |
¾” [1.9] |
¾” [1.9] |
⅞” [2.2] |
⅞” [2.2] |
|
|
|
|
|
Ship Weight |
106 lbs. [48.0] |
141 lbs. [63.9] |
173 lbs. [78.4] |
192 lbs. [87.0] |
|
|
|
|
|
¹ @220/240V ² @220/240V
[ ] Designates metric equivalents
Airflow Data
Model |
Speed |
Airflow (CFM [L/s]) Delivered against External Static Pressure (in. WC [Pa]) |
|||||
|
|
|
|
|
|||
.1 [2.5] |
.2 [5.0] |
.3 [7.5] |
.4 [10.0] |
.5 [12.5] |
|||
|
|
||||||
|
|
|
|
|
|
|
|
A24-00-2R |
High |
960 [453] |
930 [439] |
890 [420] |
840 [397] |
780 [368] |
|
Low |
810 [382] |
780 [368] |
760 [358] |
720 [340] |
670 [316] |
||
|
|||||||
|
|
|
|
|
|
|
|
A36-00-2R |
High |
1,290 [619] |
1,190 [562] |
1,100 [519] |
970 [458] |
810 [382] |
|
Low |
1,100 [519] |
1,040 [491] |
970 [458] |
860 [406] |
710 [335] |
||
|
|||||||
|
|
|
|
|
|
|
|
A48-00-2R |
High |
1,670 [789] |
1,610 [760] |
1,500 [708] |
1,440 [680] |
1,370 [647] |
|
Low |
1,310 [619] |
1,300 [614] |
1,290 [609] |
1,280 [604] |
1,260 [595] |
||
|
|||||||
|
|
|
|
|
|
|
|
A60-00-2R |
High |
1,830 [864] |
1,750 [826] |
1,700 [802] |
1,610 [760] |
1,490 [703] |
|
Low |
1,740 [821] |
1,660 [783] |
1,640 [774] |
1,540 [727] |
1,420 [670] |
||
|
|||||||
|
|
|
|
|
|
|
|
[ ] Designates metric equivalents;Airflow = Liters per second; External Static Pressure = Pascals |
|
|
|||||
Assumes dry coil with Filter in Place |
SCFM Correction for Wet Coil - 4%. |
|
|
|
2 |
www.goodmanmfg.com |