Goldstar Wg8005r Service Manual

Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : HWC081GBMK0 (WG8005R)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
MODELS
ITEMS
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT (A)
.
E.E.R (BTU/W.h)
OPERATING
CONDITION
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
INDOOR ( C)
OUTDOOR ( C)
..
C)
WG8005R
1Ø , 115, 60Hz
8,00 0
820
7.6
9.8
26.7(DB) * 19.4(WB) **
35(DB) * 23.9(WB) **
360g(12 . 7oz)
Ø
7, 2R 14 STACKS
Ø 7, 2R 16STACKS
TURBO FAN
AXIAL TYPE FAN WITH SLINGER RING
3/3
6 POLES
REMOTE CONTROLLER
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
POWER CORD
DRAIN SYSTEM
OUTSIDE DIMENSION
(W x H x D)
H x
* DB:Dry Bulb **
WB:Wet Bulb
COMPRESSOR
FAN MOTOR
(inch)
(mm)
THERMISTOR
HORIZONTAL LOUVER (UP & DOWN), VERTICAL LOUVER (RIGHT&LEFT)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
3 WIRE WITH GROUNDING
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
18
1/2
x 13
7/8
x 20
11/16
470 x 353 x 525
Room Air Conditioner
Loading...