Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : HWC081GBMK0 (WG8005R)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.

1. Specification
MODELS
ITEMS
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT (A)
.
E.E.R (BTU/W.h)
OPERATING
CONDITION
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
INDOOR ( C)
OUTDOOR ( C)
..
C)
WG8005R
1Ø , 115, 60Hz
8,00 0
820
7.6
9.8
26.7(DB) * 19.4(WB) **
35(DB) * 23.9(WB) **
360g(12 . 7oz)
Ø
7, 2R 14 STACKS
Ø 7, 2R 16STACKS
TURBO FAN
AXIAL TYPE FAN WITH SLINGER RING
3/3
6 POLES
REMOTE CONTROLLER
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
POWER CORD
DRAIN SYSTEM
OUTSIDE DIMENSION
(W x H x D)
H x
* DB:Dry Bulb
**
WB:Wet Bulb
COMPRESSOR
FAN MOTOR
(inch)
(mm)
THERMISTOR
HORIZONTAL LOUVER (UP & DOWN), VERTICAL LOUVER (RIGHT&LEFT)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
3 WIRE WITH GROUNDING
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
18
1/2
x 13
7/8
x 20
11/16
470 x 353 x 525
Room Air Conditioner

3. Wiring Diagrams3. Wiring Di a grams
Room Air Conditioner

4. Exploded Vi e w
731373
267110
130910
349480
148000
346811
349600
359012
149980
W48602
359011
554030
352390
354210
159830
135312
147582
147581
249950
238310
237200
130410
567480
W0CZZB
268711A
264110
135500
268711B
567502
554160
550140
352115
552111
352113
35211A
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Room Air Conditioner