website http://www.lgservice.com
e-mail http:flwwwJgeservice.com/techsup.htmt
I
E
Please
and thoroughly before installing and operating your room air conditioner,
MANUEL
Veuillez lire a_entivement et en entier ce guide d'utilisation et les mesures de
s6curite ci-incluses avant de proceder & Finstallation et au fonctionnement de
votre ciimatiseur.
read the operating
T
instructions and safety precautions carefully
'UTILI
E E FE
TIONE
L
A
ET
I ACONDICIO
U
L P P[ET
O
Por favor lea las instrucciones de operaciOn y las precauciones de seguridad
cuidadosa y totalmente antes de instalar y operar su acondicionador de aire
de ventana.
MODEL, MODE, MODELO: R1203H
FEATURES 2
SAFE_¢ PRECAUTIONS 3
OPERATING ...................................................................................................................................... 5
FUNCTI,ON ........................................................................................................................................ 5
VENTILATION .................................................................................................................................. 6
TO CONTROL AIR DIRECTION ................................................................................................... 6
HOW TO SECURE THE DRAIN PiPE .......................................................................................... 6
AIR FILTER CLEANING ............................................................................................................... 7
HOW TO USE THE REVERSIBLE INLET GRILLE ...................................................................... 7
ELECTRICAL DATA ........................................................................................................................... 8
BEFORE CALLING FOR SERVICE ................................................................................................... 8
INSTALLATION INSTRUCTIONS ......................................................................................................... 9
ELECTR ICAL SAFETY. ..................................................................................................................... 13
1, CABINET
2, HORIZONTAL AIR DEFLECTOR
(VERTICAL LOUVER)
3, VERTICAL AIR DEFLECTOR
(HORIZONTAL LOUVER)
4. AiR DISCHARGE
5, FRONT GRILLE
6, AIR INTAKE
(INLET GRILLE)
7, AIR FILTER
8, CONTROL BOARD
9, POWER CORD
10. EVAPORATOR
11. CONDENSER
12. COMPRESSOR
13. BASE PAN
14. BRACE
15, ELECTRIC HEATER
To prevent injury to the user or other people and property damage, the,foliowing instructions must be fol-
lowed.
m incorrect operation due to ignoring of instruction wilJcause harm or damage The seriousness is classified
by the following indications,
I Z_ WARNING " This symbol indicates the possibility of death or serious injury:
_ CAUTION , This symbol indicates the possibility of injury or damage to prop-
[] Meanings of symbols used in this manual are as shown below,
" erties only.
Be sure not to do.
_ Be sure to follow the instruction.
• Otherwise, it will cause electric
shock or fire due to heat genera-
tion.
. _twill cau_ ellectdc shock or fire
due to heat generation.
. _twill cause electric shock or fire
due to heat generation.
• it will cause el_tric: shoals,.
• _twill cause e_ectric shock or fire,
• If the _er _rd is damaged, it must
be r_laced by the manufacturer or
an authorized service center or a
similarly qualified personJnorder to
avoid a hazard.
• This could damage your health.
°3-
- It may cause an iniury. • 'Water may enter the unit
and degrade the insula-
tion. It may cause an
electric shock.
•An oxygen shortage may
o_ur.
• Since the fan rotates at
high speed during oper-
ation, it may cause an
injury.
•This could injure the pets or
plants.
• It may cause a fire or deformation
of the cabinet
• Do not usethis airconditioner to
preserve precision devices, food,
pets, p_ant&and art:obje_s.
It may cause deterioration of quaF
ity,etc.
• It may cause imperfect combus-
tion,
• It may cause an ele_ric shock,
• Usecautionwhen handlingthe
case. Gripit firmlyand do not allow
it to slipwhite holdingit,
• Useheavy#lovestohandlethecaseif
necessary.
• DONOT
allowthe
casetoslide
-4-
OPERATING
• WARNING
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY
INSTRUCTIONS before operating this appliance.
• CAUTION
When the air conditioner has been performing its cooling operation and is turned off or set to the fan
position, wait at least 3 minutes before resetting to the cooling operation again.
FUNCTION
O
Warmer Cooler _ _
Thermostat WAIT THREE MINUTES Operation
• THERMOSTAT
Turn the thermostat control to the desired setting.
The centrol position is a normal setting for average
conditions. You can change this setting, if neces-
sary, in accordance with your temperature prefer-
ence.
The thermostat automatically controls cooling or
heating, but the fan runs continuously whenever
the air conditioner is in operation. If the room is too
warm, turn the thermostat control clockwise. If the
room is too cool, turn the themostat control anti-
clockwise.
A slight heat odor may come from the unit when first switching to HEAT after the cooling season is
over. This odor, caused by fine dust particles on the heater, will disappear quickly.
BEFORE RESTARTING
• OPERATION
O(OFF) :Turns
LOW FAN ( e ):
LOW COOL ( _ ) :
HIGHCOOL(_):
LOW HEAT ( -_ ):
HIGHHEAT (-}_):
the air conditioner off.
Permits the low fan speed opera-
tion without cooling (heating).
Permits cooling with the low fan
speed operation.
Permits cooling with the high fan
speed operation.
Permits heating with the low fan
speed operation.
Permits heating with the high fan
speed operation.
TheventilationlevermustbeCLOSEpositioninorderto maintainthebestcoolingconditions.
Whenfreshairisnecessaryinthe room,settheventilationlevertotheOPENposition.
Thedamperisopenedandroomairis exhausted. Part
NOTE: Before using the ventilation feature, make a ventilation kit.
First, pull down part @ to horizontal line with part @.
TO CONTROL AIR DIRECTION
The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver and
the vertical louver.
• HORIZONTAL AIR-DIRECTION CONTROL
The horizontal air direction is adiusted by
rotating the vertical louver right or left.
. VERTICAL AIR-DIRECTION CONTROL
The vertical air direction is adjusted by rotating
the horizontal louver forward or backward,
HOW TO SECURE THE DRAIN PIPE
In humid weather, ex_ss water may cause the
BASE PAN to ovedlow. To drain the water,
remove the DRAIN CAP and secure the DRAIN
PIPE to the rear hole of the BASE PAN.
Drain pipe -_
Drain cap
°6-
AIR FILTER CLEANING
The air filter should be checked at least twice a month to see if cleaning is necessary. Trapped
particles in the filter will build up and block the airflow. This reduces the cooling capacity and also
causes an accumulation of frost on the cooling coils.
1. Open the inlet grille upward by pulling out the bottom of the inlet grille.
2. Remove the air filter from the front grille assembly by pulling the air filter up slightly.
3. Wash the filter using lukewarm water below 40°C(104°F).
4. Gently shake the excess water from the filter completely. Replace the filter.
HOW TO USE THE REVERSIBLE INLET GRILLE
The grille is designed to clean the filter both upward and downward.
®
(a) (b) (c)
A. Before attaching the front grille to the cabinet, if you want to pull out the fil-
ter upward;
1. Open the inlet grille slightly (a).
2. Turn inside out the front grille (a).
3. Disassemble the inlet grille from the front grille with separating the hinged part by inserting a
straight type screw-driver tip (b).
4. Then, rotate the inlet grille 180 degrees and insert the hooks into bottom holes of the front grille.
5. Insert the filter and attach the front grille to the cabinet.
B. If you want to pull out the filter downward;
The grille is already designed that way.
ELECTRICAL DATA
Line Cord Plug
DirOcnOt,under any
umstances, cut or
remove the grounding prong
Lfrom the plug.
Power supply cord with
3-prong grounding plug
Use Wall Receptacle Power Supply
Standard 250V, 3-wire grounding
receptacle rated 20A, 250V AC
BEFORE CALLING FOR SERVICE
, Air Conditioner will not operate.
1. Is the air conditioner plugged into the outlet?
2. Is the fuse or breaker good?
3. Is the voltage unusually high or low?
Use 20 AMP, time
delay fuse or circuit
breaker.
• Air from the unit does not feel cold enough on the cooling setting.
1. Is the setting temperature correct?
2. Is the air filter clogged with dust?
3. Is the air flow from the outside(condensers) obstructed?
Leave a clearance of over 1 meter(3.28 feet) between the back of the air conditioner and the wall or
fence behind it.
4. Are the door or windows open, or is there any source of heat in the room?
NOTE: If it is difficult to find out the cause of the trouble, be sure to turn the air conditioner off and
contact the dealer.
° OFF-SEASON MAINTENANCE
1. Clean the air filter and re-install.
2. Turn the power off by operation knob, and disconnect the power plug from the wall receptacle.
INSTA I
SELECT THE BEST LOCATION
1. To prevent vibration and noise, make sure the
unit is installed securely and firmly
2. Install the unit where the sunlight does not
shine directly on the unit.
3. The outside of the cabinet must extend
outward for at least I2" and there should be
no obstacles, such as a fence or wall, within
20" from the back of the cabinet because it will
prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must
remain exposed to the outside of the structure,
WINDOW REQUIREMENTS
1. This unit is designed for installation in
standard double hung windows with actual
opening widths from 27" to 39",
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of
16" from the bosom of the upper sash to the
window stool_
2 Install the unit a little slanted so the back is
slightly lower than the front(about !/2").
This will force condensed water to flow to the
outside_
3_ Install the unit with the bosom about 30"~60 ''
above the floor level.
INSTALLATION KITS CONTENTS
NO,
1
2
3
4
5
6
7
8
9
10
11
12
13
_nterior wall
I
235/8" rain
(Wffhout frame cumin)
NAME OF PARTS
FRAME CURTAIN
SILL SUPPORT
BOLT
NUT
SCREW(TYPE A)
SCREW(_PE C)
FOAM-STRIP
FOAM-PE
UPPER GUIDE
FOAM-PE
FRAME GUIDE
WINDOW LOCKING BRACKET
Extedor
2
2
2
2
16
3
5
1
1
1
1
2
1
SUGGESTED TOOL REQUIREMENTS
SCREWDRIVER(+,-), RULLER, KNIFE, HAMMER,
PREPARATION OF CHASSIS
1, Remove the screws which fasten the cabinet
at: both sides and at the back.
2. Slide the unit from the cabinet by' gripping the
base pan handle and pulling forward while
bracing the cabinet.
3. Remove EPS Material.
4, Cut the window sash seal to the proper length.
Peel off the backing and attach the foam-pc @
to the underside of the window sash.
5, Remove the backing from the top upper guide
Foam PE @ and attach it to the bosom of the
upper guide Q,
6. A_ach the upper guide onto the top of the
cabinet with 3 type A screws.
7. insert the frame guides @ into the bottom of
the cabinet.
8. insert the Frame Curtain O) into the upper
guide @ and frame guides @.
9, Fasten the curtains to the unit with 4 Type A
screws.
(Type A}_. i
PENCIL,
LEVEL
Shipping screws
EPS Matedal
CABINET INSTALLATION
1. Open the window. Mark a line on center of the
window stool(or desired air conditioner
location).
Carefully place the, cabinet on the window
stool and align the center mark on the bottom
front with the _nter line marked in the
window stool.
2, Pull the bottom window sash down behind the
upper guide until it meets.
NOTE:
• Do not puli the window sash down so tightly
that the movement of Frame Curtain is
restricted.
(Type A)
Upper Guid_indow ;_gll
Window Upper guide
Foam-
Fig. 2
-10-
3. Loosely assemble the sill support using the
parts in Fig. 3.
4, Select the position that will place the sill
support near the outer most point on sill
(See Fig. 4)
NOTE: Be, careful when you install the cabinet
(frame guides @ are broken so easily).
5. Attach the sill support to the cabinet track hole
in relation to the selected position using
2 Type A screws in each support(See Fig. 4).
6. The cabinet should be installed with a very
slight tilt(about 1/£) downward toward the
outside (See Fig. 5).
Adjust the bolt and the nut of sift support for
balancing the, cabinet.
F_me Guide @
INDOOR
brew(Type B) Q
NutQ
_rew(Type A) @
11,
i,
Cabinet
OUTDOOR
Fig, 3
Fig. 4
7. Attach the cabinet to the window stool by
driving the screws ®(Type B: Length sixteen
millimeters and below.) through the front angle
into window stool,
8. Pull each Frame curtain fullly to each window
sash track, and repeat step 2.
9. Attach each Frame curtain the window sash
using screws Q(Type C).
(See Fig, 6)
Sill supp,ortQ
FrontAngle
Screw(Type B)
Sill suppod(_)
Fig. 5
c©
-11 o
10.Slidetheunitintothecabinet.(SeeFig.7)
CAUTION:Forsecuritypurpose,reinstall
screws(TypeA)atcabinet'ssides.
11,Cutthefoamostnp® totheproperlength
andinsertbetweentheupperwindowsash
andthelowerwindowsash.
(SeeFig.8)
12.Attachthewindowlockingbracket@witha
typeC screw.(SeeFig.9)
Screw(Type A}
.......Power cord
z
Screw(Type A)
locking bracket@
Fig. 7
Foam-S_rip
Fig. 8
13. Attach the front grille to the cabinet by insert-
ing the tabs on the grille into the tabs on the
front of the cabinet. Push the grille in until it
snaps into pLace.(See Fig. 10)
14. Lift the inlet grille and secure it with a type A
screw through the front griHe.(See Fig. 11)
Fig, 9
..............................................
Fig, i0
Fig. 11
Fig. 12
_12o