Gas Built-in Hob
1 BURNER GAS HOB (GL301N) 2 BURNER GAS HOB (GL2N, GL302N) 3 BURNER GAS HOB (GL3N, GL603N, GL3SS) 4 BURNER GAS HOB (GL4N, GL4SS) 4 BURNER GAS HOB (GL704N)
INSTALLATION INSTRUCTIONS (FOR FITTERS ONLY)
USER AND OPERATOR INSTRUCTIONS
Installation must be in accordance with manufacturer’s instruction, relevant Gas Fitting Regulations or AS5601 – “Gas Installation” regulations.
These instructions should be read carefully prior to initial use and retained in a safe place in order that full advantage can be taken of the features of your HOB COOKER.
REMINDER:
ANY SERVICING AND INSTALLATION OF THE HOTPLATE
MUST BE CARRIED OUT BY AN AUTHORIZED PERSON.
ANY QUERIES SHOULD BE FORWARDED TO:
MANUFACTURER: A’VARD INDUSTRIES P/L. ADDRESS: 58-60 Quantum Close, South Dandenong, Victoria 3175, Australia. TEL: 61 3 9799 9660 FAX: 61 3 9799 9662 WEBSITE: www.goldlinecorp.com.au
Goldline N12- manual-ULPG Jan 2012
1
Goldline N12- manual-ULPG Jan 2012
2
Model GL301N/GL301ND
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
Model GL302N/GL302ND
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
Model GL2N/GL2ND
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
Model GL3N/GL3SS
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
470
475
Model GL603N/GL603ND
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
Model GL4N/GL4SS
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
Model GL704N
Diagram A Tray Dimensions (in mm)
Diagram B Cut-Out (in mm)
Goldline N12- manual-ULPG Jan 2012
3
Goldline N12- manual-ULPG Jan 2012
4
INSTALLATION INSTRUCTIONS
DATA PLATE DETAILS: The data plate is located on the tray oor.
CHECK THAT THE DATA PLATE SHOWS THAT THE APPLIANCE IS SUITABLE FOR THE AVAILABLE GAS SUPPLY. IMPORANT: VERIFY GAS TYPE WITH LOCAL GAS NETWORK
OPERATOR BEFORE CONNECTION OF THIS APPLIANCE.
1. Room Ventilation This cooktop must be installed in a room that has permanent ventilation to effect the correct operation of the appliances and also to provide adequate ventilation. This airow must exceed 20m³ via permanent vented openings in the walls of the room and these must have a section of 100cm² minimum. They must be constructed in a manner so as to avoid any possible blockages. The airow can also be drawn indirectly from an adjacent room provided it complies with any local regulations to vent any fumes outdoors.
Not for use in Marine craft, caravans or Mobile homes unless tted with safety device.
2. Before installing the appliance check that the location provides the required clearances from combustible materials and if necessary provide protection to adjacent surfaces as required by the regulations. Make provision for the gas supply to be connected in the position shown in Diagram A.
3. Cut the opening in the bench top to the dimensions shown in diagram B.
4. Remove the hotplate from the carton.
Refer – Gas tting manual.
Position of gas inlet: See diagram on page 2. Depth from top of glass to bottom of tray: 70mm excluding regulator
5. Install the hotplate in the cut-out (see diagram B on page 2).
Note:
If clearance between side and rear walls and periphery of the burner is less than 250mm, the walls must be protected with a non-combustible material. The protection must extend a minimum distance of 450mm above the burner. Horizontal surfaces less than 750mm vertically above the hotplate must also be protected.
6. Ensure that gas and electrical outlet are accessible with the appliance installed.
The gas connection to the regulator is 1/2” BSP. Please ensure gas supply line to the appliance is of adequate length to allow sufcient withdrawal of appliance for service or disconnection. The connection must be annealed copper pipe or exible hose (if permissible by local authority).
7. In the event that exible hose is being used:
- The exible hose must be certied to AS/NZS1869 - class B or class D.
- The gas connection point must be between 800 to 850mm above the oor and in the
region outside the width of the appliance to a distance of 250mm.