Remote Display
for
Aqua LogicAqua Logic
Aqua Logic
Aqua LogicAqua Logic
Automation and Chlorination
®
G
(model AQL-WW-PS-8 shown above)
Installation/Operation Manual
for model
AQL-WW-PS-4
AQL-WW-PS-8
AQL-WW-PS-16
LD
LINE
C
ONTROLS
www.goldlinecontrols.com
888-921-7665
COMPATIBILITY: This display/keypad is compatible with all Aqua Logic-PS-4/8/16
systems running main software r2.00 or higher.
INSTALLATION
Mounting
The AQL-WW-PS-4/8/16 Aqua Logic Remote Display/Keypad must be mounted indoors or in a weather protected area (rain should never hit the display/keypad). Up to
3 remote display/keypads can be installed. The display/keypad is designed to mount
onto a standard electrical utility box (same size as used for a triple light switch) or can
be mounted directly onto any wall surface. When selecting a location, note that the
wire to the Aqua Logic main unit must be less than 500 feet long. Follow the steps
below:
1. Remove display/keypad baseplate from the cover by lifting up on the cover at the
lower end of the keypad as shown below.
Pull up on bottom edge
to remove cover
2. Screw the baseplate in the desired position (screws supplied by installer).
Wiring
The Aqua Logic main unit can connect to a maximum of 3 remote display/keypads.
Use four conductor cable (typically phone cable) to connect the remote display/
keypad with the Aqua Logic Control Center as shown on page 2. The maximum wiring
distance is 500ft. (160m). Note that the terminals on both the Aqua Logic main unit
and the remote display/keypad are numbered: Connect 1 to 1, 2 to 2, etc. Refer to
diagram on the top of the following page.
If multiple remote display/keypads are installed: Never connect more than 2 wires to
any terminal block. Two remotes can be wired back to the Aqua Logic main unit or the
second display/keypad (and third, if applicable) can be “daisy chained” with one
display/keypad wired to the next. The maximum wire run from the Aqua Logic main
unit to the furthest remote display/keypad is 500 ft. (160m).
1 6
Connect screw terminals
“1” to “1”, “2” to “2”, etc.
1
2
3
4
qua Logic Control Center
Wired Remote
Display unit
12
34
500 ft max
OPERATION
When power is turned on, all the LED indicators will flash briefly, the display backlight will illuminate, and the following display will appear for a short period of time:
Goldline Aqua Logic
Display r3.00
The "r3.00" is the software revision level. The actual revision level for your display/
keypad may be different.
Refer to the Aqua Logic Operation Manual for complete operating instructions.
25