Global Industrial 246105 User Manual

globalindustrial.ca
User's manual Manual del usuario Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
US: 1-800-645-2986
Service à la clientèle
Canada: 888-645-2986
Energy Efficient Portable Dehumidifier
Model 246105
30 Pint Dehumidifier
Model 246106
50 Pint Dehumidifier
Model 246107
70 Pint Dehumidifier
Model 246108
70 Pint Dehumidifier
w/Built-in Pump
WARNING
DO NOT allow children or non-qualified persons operate this dehumidifier.
• Disconnect unit from its power source before cleaning, maintenance, servicing or replacing parts.
Disconnect all supply circuits before accessing terminals.
• NEVER attempt to plug in or operate dehumidifier with defective or damaged wires, power cord, or power cord plug. All defective parts should be replaced immediately by a qualified service technician using genuine replacement parts.
• Check the nameplate for the type of refrigerant gas used in the appliance. Maintenance and disposal operations must be carried out by qualified personnel only.
• This hermetically sealed system contains fluorinated Greenhouse gases covered by Kyoto Protocol.
• DO NOT damage the cooling circuit of the machine.
• DO NOT use this unit for functions other than those described in this manual.
• Ensure power plug is firmly and completely plugged into the outlet. Doing so will avoid risk of electric shock or fire.
• DO NOT plug other appliances into the same outlet. Doing so may result in the risk of electric shock.
Please read entire manual carefully before use. Save
manual for future reference.
• DO NOT disassemble or modify the appliance or any of its parts. Doing so may result in the risk of electric shock or fire. All services should be referred to a qualified technician.
• DO NOT place the power cord or dehumidifier near a heater, radiator, or other heat source. Doing so may result in the risk of electric shock or fire.
• This unit is equipped with a cord that has a grounded wire connected to a pin or grounding tab. The plug must be plugged into a socket that is properly installed and grounded. DO NOT under any circumstances cut or remove the grounded pin or grounding tab from the plug.
• The unit should be used or stored in such a way that it is protected from moisture, condensation, water, etc.
• ALWAYS transport your appliance in a vertical position and place on a stable, level surface during use. If the unit is transported on its side it should be stood up and left unplugged for 6 hours prior to use.
• ALWAYS use the power switch on the control panel or remote control to turn the unit on/off. DO NOT start or stop operation by plugging or unplugging the power cord. Doing so can result in the risk of electric shock.
• DO NOT press the buttons on the control panel with anything other than your fingers.
1
062019
Energy Efficient Portable
Dehumidifier
User's Manual
• DO NOT use hazardous chemicals to clean or come into contact with the unit. To prevent damage to the surface finish, use only a soft cloth to clean the appliance. DO NOT use solvents, or strong detergents.
• DO NOT use the unit in the presence of flammable substances or vapors such as alcohol, insecticides, or gasoline.
• If the appliance is making unusual sounds or is emitting smoke or an unusual odor, unplug it immediately.
• DO NOT clean the unit with water. Water can enter the unit and damage the insulation, creating a shock hazard. If water enters the unit, unplug it immediately and contact Global Industrial Customer Service at 1-800-645-2986.
• Utilize two or more people to lift and install the unit.
• Be sure all accessories are removed from the packaging before installation and use.
• Avoid contact with the metal parts of the appliance when removing or re-installing the filter.
• DO NOT block the air inlet or outlet of the dehumidifier. Reduced air flow will result in poor performance and could damage the unit.
• ALWAYS grasp the plug when plugging or unplugging the unit. Unplugging the unit by pulling on the cord can run the risk of electrical shock and damage.
• Install the dehumidifier on a sturdy, level surface capable of supporting up to 110 lbs. (50kg). Installation on a weak or non level surface can result in the risk of property damage and personal injury.
• Close all doors and windows to the room for efficient operation.
CAN ICES-3 (B)/NMB-3(B)
FCC CAUTION: This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
any circumstances, be cut or removed. Never use the cord, the plug or the appliance when they show any sign of damage. Do not use your appliance with an extension cord unless it has been checked and tested by a qualified electrical supplier. Improper connection of the grounding plug can result in risk of fire, electric shock and/or injury to persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is properly grounded.
ELECTRICAL CONNECTIONS
Before plugging the appliance into outlet check that:
• The power supply corresponds to the value indicated on the rating plate on the back of the dehumidifier.
• The power outlet and electrical circuit are adequate for the dehumidifier.
• The outlet matches the plug. If this is not the case, have the plug replaced.
The outlet is adequately grounded. Failure to follow these important safety instructions may result in injury or damage and exempts Global Industrial of all liability.
Check local regulations for proper waste disposal procedures. As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-out wheeled dustbin.
NOTES ON HUMIDITY
Air always contains a certain amount of water in the form of vapor. This determines the level of humidity in an atmosphere. The capacity of the air to hold water vapor increases with temperature. This is why in our homes, as soon as the temperature decreases, the vapor contained in the air condenses. This is evident on the colder surfaces in the room, such as the windows, walls, etc. The purpose of a dehumidifier is to remove the excess moisture from the air, avoiding damage caused by condensation.
Experts have established that the optimum environmental conditions for our well-being and for the home are between 40% and 60% relative humidity. In low temperatures, it is recommended to heat the room minimally. This considerably increases the dehumidifying power of the appliance. With heating, the condensation formed by the water vapor on windows and other cold surfaces evaporates into the air to be collected by the dehumidifier. Air leaving the dehumidifier is usually about 1-2° warmer than room temperature.
IMPORTANT - GROUNDING METHOD
This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under
2
COMPONENT BREAKDOWN
User's Manual
Energy Efficient Portable
Dehumidifier
1
2
6
7
1 Control Panel 2 Air Outlet 3 Bucket 4 Water Level Indicator 5 Casters
8
3
6 Handle 7 Air Intake Grille
4
8 Drainage Holes 9 Power Cord
5
9
*Note: All illustrations in this manual are for explanatory purposes only. Your unit might look slightly different.
Before using, remove all accessories from the bucket: Detach the bucket, open the cover, remove the plug and all other accessories. Reinstall the cover, and correctly reattach the bucket into the dehumidifier.
Accessories Included:
Casters (4)
Pump Adapter
Casters (4)
Plug
Pump Adapter (for model 246108 only)
Drain Hose (for model 246108 only)
Attaching the Casters
Tilt the unit no more than 45° and insert the casters with force. Make sure the plate of the casters is flush against the bottom of the unit.
1
F F
E ED DC CGB BA A
The above figure is for models 246105, 246106, & 246107 (without pump) The above figure is for model 246108 (with pump)
A 45°
Plate on
Caster
12
23 384 5 476 5 6 7
PUMP
PUMP
1 Clean Filter Symbol 5 Timer "On" Symbol A On/Off Button E Fan Speed Button 2 High Fan Speed Symbol 6 Bucket Full Alarm B Timer Button F Filter Reset Button 3 Display Screen 7 Continuous Symbol C Decrease Button G Pump Button 4 Timer "Off" Symbol 8 Pump Symbol D Increase Button
3
Energy Efficient Portable
Dehumidifier
User's Manual
On/Off power supply is used to control the start-up or
shut down of the dehumidifier.
Increase and decrease the indoor humidity level,
or set the time.
• Humidity adjustable range is 35%RH-80%RH. The screen will display the setting humidity, and after few seconds, turn to display the ambient humidity.
• When the ambient humidity is lower than the set humidity, the compressor will stop running and after a few minutes, the fan will stop running.
• To continuously run, press the button until is displayed on the screen and the continuous symbol lights up.
Fan speed is used to select the speed from Low to
High. Speed is on high when the symbol lights up.
T
imer button is used to to delay start-up or shutdown.
This avoids wasting electricity by optimizing operating periods.
PROGRAMMING START-UP
• Turn machine on and choose mode; for example: Dehumidify Mode, High Fan Speed. Turn machine off.
• Press Timer Button, the screen will begin to flash. Press the buttons to adjust the set-time from 0.5 to 24 hours.
• After 5 seconds without operation, the timer will begin and the symbol will light up.
• To cancel Timer, press Timer button again and the will disappear.
BUCKET FULL ALARM
• When the bucket is full, the compressor will shut-off and after a few minutes the fan will stop. The machine will begin to beep and the bucket full symbol will flash.
• The unit will not run again until the bucket is emptied and properly placed back inside the dehumidifier.
• Clean the bucket weekly to prevent growth of mold, mildew and bacteria. Use a mild detergent to clean. Ensure bucket is completely dry before reinstalling back into dehumidifier.
• NOTE: Hold the bucket with both hands when emptying.
• NOTE: When the bucket is full or removed from the unit, the compressor will turn off but the fan will continue to run for a few minutes. This is completely normal; the machine will not be removing moisture from the air at this time.
• NOTE: During normal operation, the humidifier will exhaust warm air from the top of the unit.
CAUTION: DO NOT place the bucket on the floor when full as bottom is uneven and may cause spillage.
AUTOMATIC DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears. When the coils are completely defrosted, the compressor or fan (depending on the model) will automatically restart and dehumidification will resume.
CONTINUOUS DRAINAGE
Using Built-In Pump (Model 246108 Only)
Drain Adapter
• Connect the drain pipe on the back of the dehumidifier; this will allow the unit to run continuously without the use of the bucket.
1. Place the dehumidifier on a level
surface and unscrew the cap on the back of the unit.
2. Install the drain and gasket connector.
3. Install the drain pipe to the connector.
4. Press Power button to run the
unit. For Model 246108 Pump Drain:
5. Press the “PUMP” button to start the pump drain
function, and the “PUMP” symbol will light up. The maximum height of pump drainage is 16.4 ft (5 meters).
Seal Ring
Drain Hose
MAX. 5m (16.4 ft.)
CONTINUOUS DRAIN HOSE ROUTING
Without Pump (All Models)
1. Connect 1 onto the units drain hole.
2. Make sure hose is installed correctly, otherwise the water will not drain properly, (see image below).
3. Use gravity to drain water to a nearby drain or other location.
Correct Incorrect
• If the continuous drain function is not needed, install the
cap on the drain hole on the back of the unit and the water will flow into the bucket.
NOTE: Ensure the unit is placed on a level surface, otherwise the water will not drain properly.
1
/16" threaded garden hose (not included)
4
Energy Efficient Portable
Dehumidifier
User's Manual
LOCATION REQUIREMENTS
Note: Basement operation will have little to no effect in drying out an adjacent enclosed area, such as a closet, unless there is adequate circulation of air in and out of the area.
YES NO
Above
5°C
41°F
18"
Below
5°C
41°F
CLEANING AND MAINTENANCE
WARNING
Before cleaning and maintenance, turn the power off on the control panel of the dehumidifier. Wait a few minutes then unplug the unit from the outlet. Not doing so increases the risk of electric shock or fire.
The dehumidifier’s water collection tank must be cleaned with soap and warm water or a mild detergent frequently. Mold and mildew can build up quickly, and when inside a dehumidifier tank, it can get dispersed into the air, affecting air quality.
Several times a season, use a vacuum with a brush attachment to clean the intake and exhaust grilles. Dust and debris build-up can cause blockages that can lead to deterioration of the unit.
Cleaning Filter
To keep the appliance working efficiently, it is recommended to clean the filter every week of operation:
• Use a vacuum with a brush attachment to remove dust
accumulation from the filter.
• If filter is very dirty, immerse it in warm water and rinse
several times. The water temperature should never be hotter than 104°F (40°C). Allow filter to fully dry before reattaching back to the dehumidifier.
18"
18"
• This unit is designed for indoor use only.
• Place the dehumidifier on a level floor surface that is strong enough to support the unit with a full bucket of water.
• Allow at least 18 inches of air flow on all sides.
• Place the unit in an area where the temperature will not fall below 41°F (5°C).
Utilize the dehumidifier in areas of excessive moisture, such as basements, kitchens, laundry rooms and bathrooms.
• Keep dehumidifier away from clothes dryer.
• The dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows and any other outside openings for best results.
End of Season Maintenance and Storage
• T urn off power and unplug from outlet.
• Empty the bucket.
• Remove cap and drain remaining water into a basin.
• When all water has been drained, put the cap back in place.
• Clean filter and dry thoroughly before reinstalling.
• Cover the appliance for dust protection.
• Store the dehumidifier upright in a dry location.
Start of Season Checks
• Inspect dehumidifier for signs of damage.
• Inspect power cable and plug for signs of damage.
• Follow the installation instructions precisely.
• Please contact Global Industrial Customer Service at 1-800-645-2986 for questions and inquiries.
5
TROUBLESHOOTING
Problem Possible Cause Solution
Energy Efficient Portable
Dehumidifier
The dehumidifier is unplugged.
The fuse is blown/circuit breaker is tripped.
User's Manual
Make sure the dehumidifier's plug is pushed
completely into the outlet.
Check the house fuse/circuit breaker box
and replace fuse or reset breaker.
Dehumidifier does
not start.
Dehumidifier does
not dry air as it should.
Appliance runs
too long.
Dehumidifier has reached its present level
or the bucket is full.
Bucket is not in the proper position.
Power Failure.
Not enough time allowed for unit
to remove moisture.
Airflow is restricted.
Dirty filter
The humidity control may not
be set low enough.
Doors and windows may not
be closed tightly.
Clothes dryer may be blowing moist
air into the room.
Room temperature is too low.
The area is too large.
Doors and windows are open. Close all doors and windows.
The dehumidifier automatically turns off when
either condition occurs. Change to a lower setting
or empty the water bucket and replace properly.
The bucket must be in place and securely seated
for the dehumidifier to operate.
There is a protective time delay
(up to 3 minutes) to prevent tripping of the
compressor overload. For this reason, the unit
may not start normal operation for 3 minutes
after it is powered back on.
When first installed, allow at least 24 hours
to maintain the desired dryness.
Make sure there are no curtains, blinds, or
furniture blocking the front or back of the
dehumidifier. See the Location Requirements
section of this manual for more information.
See the Cleaning Filter section of this
manual for more information.
For drier air, press the button to lower the
percent humidity desired in the room, or set the dehumidifier to for maximum dehumidify.
Check that all doors, windows, and other
openings are securely closed.
Install the dehumidifier away from the dryer.
The dryer should be vented outside.
Moisture removal is best at higher room
temperatures. Lower room temperatures
will reduce the moisture removal rate. This
dehumidifier is designed to operate at
temperatures above 5°C (41°F).
The capacity of the appliance cannot
meet the area of the room.
Frost appears on heat
exchanger.
Fan noise The air is passing through the appliance. This sound is normal.
Water on the floor.
Appliance has been operated recently or
the room temperature is too low.
Drain connections are not fastened properly.
dehumidifier is not on a level surface.
This is normal, frost usually disappears
within 60 minutes.
Check the drain connection for leaks and fasten
properly. Make sure the appliance is operating
on a level surface.
If any of the following error codes appear, contact a certified after-sales service department for inspection and/or repair. For additional information, contact Global Industrial Customer Service at 1-800-645-2986.
Code Description
P1 Bucket Pull Out
EH Humidity sensor failure
E1
Temperature sensor failure
E2
• Code P1 applies to model 246108 (with pump) only.
If code E3 appears, check to see if the room temperature is above 90°F (32°C). If this is the case, relocate the dehumidifier in a location below 86°F (30°C) and allow to sit for 2 hours before running again. Start the unit again; if the E3 code still appears, contact a service department or Global Industrial Customer Service at 1-800-645-2986 for further instructions.
E3 Gas leakage
6
Loading...
+ 12 hidden pages