All prices are LIST. Applicable taxes will be added.
QuotationS:
Unless otherwise stated, quotations are effective for 30 days only.
dElivEry:
The majority of equipment is manufactured to order and typically ships
within three to six weeks after complete order information is received by
the factory. In-stock equipment typically ships within two to three days
of the factory receiving complete order information.
aCCEptanCE:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in
Saginaw, Michigan. Possession of the Product Directory and Price List
is not an offer to sell.
ShipmEntS:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or
Collect if shipped directly to you. Prepay and Add to Invoice freight
terms are available upon request. The approximate shipping weights of
all products are listed with the prices. Partial shipments will be made
unless otherwise specified by the customer. Surface freight classifications are:
Glasswashers, Line Chillers - Class 92.5
Cocktail Stations, Underbar Equipment - Class 85
Bar Die/Underbar Equipment – Class 125
Refrigeration Equipment, 48” long or smaller - Class 100
Refrigeration Equipment, greater than 48” long - Class 110
All small items are evaluated to see the most cost effective means for
shipment. Many small items ship via UPS or FedEx; however, when
dimensional weight is excessive DB Schenker, UPS Supply Chain, or
even common LTL carriers are the most cost effective choice. Spare
parts orders received before 1:00 PM EST can usually be shipped the
same day.
The order department is happy to assist with routing or shipping questions.
paymEnt tErmS:
Cash should be included with all orders unless credit terms have been
arranged. To establish credit, banking and trade references are required.
A convenient credit application is available upon request. Payment via
credit card is not our normal means of receiving payment. Visa and
MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than
$500 will incur a 3% convenience fee on the total transaction amount.
rEturnS:
Items specified as “Manufactured to Order” are NOT returnable.
A Return Material Authorization (RMA) number must be issued by the
factory in advance for any items that are returnable. The RMA number
MUST be noted on the outside of the returned package. Returns must be
received within 90 days of the RMA issue date. Shipping charges must
be prepaid. A minimum 20% restocking charge will be applied to all
authorized returns if received in new, unused condition in the original
packaging.
The above conditions apply to spare part returns, except spare part
returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts.
loSSor damagE:
For customer routed shipments, Glastender, Inc. is not responsible for
any loss, damage, or delay of merchandise during shipment. Such transit
claims must be filed with the carrier. Merchandise must be examined on
arrival. If shortages occur, Glastender, Inc. must be notified in writing
within five (5) days of delivery to honor any shortage claim. Glastender
will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon
receipt. Failure to do so may result in losses at the customer’s expense.
CuStom ordErS:
Custom orders must be paid in advance and are not subject to cancellation.
laminatES:
Some products include common, readily available plastic laminates of
the customer’s selection. There may be an additional charge if uncommon varieties are ordered.
05/18/10
CoolEr SErial numBEr information
This manual is specic to 2008 Energy Star compliant self-contained BB60, BB84, BB108,
ND52, ND72, and ND92 coolers beginning with the serial numbers and dates listed below in
addition to all BB and ND Two Zone Coolers.
To change the set point - push and hold the SET button for
more than two seconds. When the º F display begins ashing,
push the up arrow or down arrow buttons to adjust the set point
to the desired value.
To save the new set point and return to the temperature
display mode - push and release the SET button or wait ten
seconds.
Factory SettingsRange of Adjustment
Set PointOperating Range†Minimum Set PointMaximum Set Point
Standard Cooler Setting
Two Zone Cooler Settings*
B = Beer
W = White Wine
R = Red Wine
34º F34º F to 39º F33º F35º F
34º F34º F to 39º F33º F35º F
50º F50º F to 55º F45º F55º F
60º F60º F to 65º F55º F65º F
† Adjusting the factory set point will also adjust the operating range by the same amount
* To determine a Two Zone Cooler refrigeration conguration, refer to the 2 digits immediately preceding the rst hyphen of the
model number found on the cooler data tag. These 2 digits will always be BW (Beer/White Wine), BR (Beer/Red Wine), or WR
(White Wine/Red Wine). Example: MODEL: BB60BR-L1-XS(LR).
The refrigerator is programmed to automatically defrost four
times daily for approximately twenty minutes. During defrost,
the fan inside the cooler will remain on and the refrigeration
system will turn off. To initiate defrost manually, push and
hold the DEFROST button for more than two seconds.
The thermostat controller does not have an “OFF” function.
To turn refrigerator off, the unit must be unplugged or power
to the electrical branch circuit has to be turned off via a circuit
breaker or switch.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
This manual describes the operational features of self-contained BB60, BB84, BB108, ND52, ND72, and ND92
coolers and two zone coolers. Please review this information before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed.
Thank you for selecting Glastender, Inc. products.
utility rEQuirEmEntSand ConnECtionS
• Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 6-foot grounded
cord and plug is included with self-contained models.
• Plumbing: Automatic condensate evaporator is included. No drain connection required.
unCratingand Start-up inStruCtionS
All models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base if included.
3. Position unit and level and/or seal as required (see page 4 and 5).
4. All units intended for draft beer must be plumbed to an external drain. On self-contained models with
draft beer and a factory installed finished top, the beer tower drain pan is plumbed through the cabinet
and stubs out in the 3" space below the compressor compartment. Connection to an external drain must
be made from that point.
5. Place shelves in desired location.
6. Plug into 115 volt AC outlet.
7. Load with bottles or cans and allow time for products to cool.
8. Your Glastender equipment is now ready for use.
opEration
The operating temperature range is 34°F (1°C) to 40°F (5°C).
Self-contained models include an automatic defrost system. The refrigerator will defrost four times daily for
approximately 20 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration
system will turn off.