Glastender BB108L Parts List

Operation Manual, Parts Directory and Price List
A Family Company Manufacturing
In The USA Since 1969
Vertical Door coolers
self-containeD MoDels - BB24, BB36, BB60*, BB84*, BB108*, ND52*, ND72*, ND92*,
FV24*, FV48*, LP60*, LP84*, LP108*, PT60, PT84, PT108, KC24, KC48, KC52, KC72, KC84*
*see Page 2 for iMPortant cooler serial nuMber inforMation
Rev. 01-24-17
FV24-BS(L)
BB60-L1-XSH(LR)
BB72-R1-BLN(LLR)
shown with optional wood panel doors
Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780
800.748.0423 · 989.752.4275 · Fax 800.838.0888 / 989.752.4444 · www.glastender.com
PT60-L1-LLH(LR/RL)
© 2008 Glastender, Inc.
serVice anD Parts
Cooler Serial Number Information ................................................................. 2
Terms and Conditions...................................................................................... 3
Warranty .......................................................................................................... 4
installation
Introduction ..................................................................................................... 5
Utility Requirements and Connections ........................................................... 5
Uncrating and Start-Up Instructions ............................................................... 5
Operation ......................................................................................................... 5
Cleaning Instructions ..................................................................................5 - 6
Floor Sealing Instructions ............................................................................... 6
BB24 Minimum Air Flow Clearance Diagram ............................................... 6
Cooler Installation Checklist ........................................................................... 7
Cooler Design Change .................................................................................... 8
sPecifications
Electrical and Refrigeration Specifications ..................................................... 9
Wiring Diagrams ...................................................................................... 10-14
Endwall Models ...................................................................................... 10
Self-Contained Models ............................................................................11
Remote Models ....................................................................................... 12
Remote Models with Solenoid Control .................................................. 13
Built-in Fluorescent Light Fixtures ........................................................ 13
BB24 Self-contained and KC24 Models ................................................ 14
rePlaceMent Parts
Compressor and Condenser Related Parts ............................................... 15-22
BB24 Self-Contained & KC24 ............................................................... 15
BB36 ....................................................................................................... 16
LP60, LP84, LP108, and Non Endwall BB60, BB84, BB108,
ND52, ND72, ND92, KC72, and KC84 ................................................. 17
BB36, BB60, ND52, and KC52 Endwall ............................................... 18
BB84, BB108, ND72, ND92, KC72, and KC84 Endwall ..................... 19
KC48 ....................................................................................................... 20
PT60, PT84, PT108 ................................................................................ 21
FV24 and FV48 ..................................................................................... 22
Evaporator and Related Parts ................................................................... 23-25
Doors and Related Parts ........................................................................... 26-29
Shelving, Racks and Related Parts ................................................................ 30
Refrigeration Compartment Covers .............................................................. 31
220 Volt Electrical Parts ........................................................................... 32-33
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
1
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
cooler serial nuMber inforMation
bb & nD cooler serial nuMber inforMation
This manual is specic to self-contained BB60, BB84, BB108, ND52, ND72, and ND92 coolers
prior to the serial numbers and dates listed below.
BB60R 134121363F 02/26/09 BB60L 134121425F 03/03/09 BB84R 134121457F 03/04/09 BB84L 134121456F 03/04/09 BB108R 134121452F 03/04/09 BB108L 134121226F 02/17/09
ND52R 134121519F 03/09/09 ND52L 134121559F 03/11/09 ND72R 134121906F 04/08/09 ND72L 134121475F 03/11/09 ND92R 134121126F 02/09/09 ND92L 134122745F 06/10/09
fV cooler serial nuMber inforMation
This manual is specic to self-contained FV coolers prior to the serial numbers and dates listed below.
FV24 SN 134143788F and excluding SN 134142753F & SN 134143411F 05-13-13 FV48 SN 134143788F and excluding SN 134142796F 05-13-13
lP cooler serial nuMber inforMation
This manual is specic to self-contained LP coolers prior to the serial numbers and dates listed below.
LP60R SN 134128786F 09-28-10 LP60L SN 134128783F 09-28-10 LP84R SN 134129050N 09-28-10 LP84L SN 134128771N 09-28-10 LP108R SN 134131070N 09-28-10 LP108L SN 134129406N 09-28-10
Kc cooler serial nuMber inforMation
This manual is specic to self-contained KC84 coolers with serial numbers beginning with 404.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
2
terMs anD conDitions
Prices:
All prices are LIST. Applicable taxes will be added.
Quotations:
Unless otherwise stated, quotations are effective for 30 days only.
accePtance:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell.
shiPMents:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifica­tions are:
• Glasswashers - Class 125
• All Underbar Equipment (including Bar Die) – Class 150
• Portable Bars - Class 150
• Remote refrigerators (i.e., no compressor) or dry storage back bar equipment - Class 125
• Self-contained refrigeration equipment - Class 150
• Ice Display Units (IDU and GDU) - Class 85
• Lighted Liquor Displays - Class 85
• Beer line chillers and beer towers (beverage dispensing equipment)
- Class 92.5
• Bottle Disintegration System - Class 150
• Ice Cream Freezers - Class 77.5
All small items are evaluated to see the most cost effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive, LTL carriers are the most cost effective choice. Spare parts orders received before 1:00 PM EST can usually be shipped the same day.
The order department is happy to assist with routing or shipping questions.
PayMent terMs:
Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of ship­ment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount.
DeliVery:
The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information.
returns:
Items specified as “Manufactured to Order” are NOT returnable.
A Return Authorization number must be issued by the factory in advance for any items that are returnable. The number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the issue date. Shipping charges must be prepaid. A mini­mum 20% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging.
The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for elec­tronic or electrical parts or within 90 days for all other parts.
loss or DaMage:
For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add ship­ments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer’s expense.
custoM orDers:
Custom orders must be paid in advance and are not subject to cancellation.
laMinates:
Some products include common, readily available plastic laminates of the customer’s selection. There may be an additional charge if uncom­mon varieties are ordered.
07/21/16
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
3
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
Warranty stateMent
APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA
Glastender, Inc. warrants all products to be free of defects in mate­rial and workmanship. One-year labor and parts warranty applies to all glasswashers, self-contained refrigeration models, and BDS model bottle disintegration units. In established areas, a start up is included with GT-24 and GT-30 model glasswashers. Warranty is effective for one year from the date of installation or up to 18 months from date of factory shipment, whichever occurs sooner. Glastender, Inc. will replace any part or assembly found defective under normal use and service.
For warranty labor claims beyond 15 months from the date of factory shipment, proof of date of installation or occupancy must be provided. Authorization for labor must be obtained from Glastender within the warranty period and prior to the service being performed.
Labor warranty applies to the United States and Canada only.
Remote refrigeration models and beer line chillers include a one-year parts warranty only. There is no labor warranty on these products.
Field replacement parts not covered under the original warranty include a 90-day part warranty from the date of installation.
FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY: Glastender will warrant to the original user the compressor for all self­contained refrigeration models for an additional four years following the regular one-year warranty period. This plan applies to the compressor only.
A completed warranty claim form MUST accompany all returned defec­tive parts or assemblies. Upon request, a defective part or assembly must be returned to Glastender, Inc., Saginaw, Michigan, with all transporta­tion and delivery charges prepaid. Warranty repairs or replacements will be shipped FOB factory in Saginaw, Michigan. Reimbursement for applicable freight charges covers ground service only.
Glastender provides in-warranty repairs during a service company’s regular working days and hours. There is no provision for payment of a premium rate during “overtime” hours. When warranty service is requested during other than normal working hours, the end user will be charged the premium portion of the overtime rate.
The warranty covers substantiated travel expenses for up to 2 hours / 100 miles round trip up to a maximum of $150. Any additional costs due to installations that require extra work, time, or travel to gain access for service are the sole responsibility of the equipment purchaser. Any exceptions to these travel and access limitations must be pre-approved by a factory representative.
The warranty does not cover equipment subjected to accidents, freight damage, alterations from the original design, improper power and/or plumbing hookups, improper chemical use, general misuse, or lack of routine required maintenance as determined by Glastender, Inc. Installation, normal control adjustments, general maintenance, correct­ing an installation error, or service calls that reveal the unit is function­ing normally will not be reimbursed under warranty.
Condenser coils on self-contained refrigeration products must be cleaned regularly. Failure to provide adequate air flow to a refrigeration unit will void the warranty.
Glastender shall not be liable for loss of use, revenue, or profit, or for any other indirect, incidental, special, or consequential damage includ­ing, but not limited to, product spoilage or loss.
This warranty is conditioned upon Glastender receiving notice of any defect subject to this warranty within sixty (60) days of its discovery by the end user or dealer. All products are warranted only for the initial place of installation. Removal of a product automatically terminates this warranty.
SECOND YEAR EXTENDED PARTS & LABOR WARRANTY:
Glastender’s one-year parts and labor warranty on self-contained refrig­eration units, excluding beer line chillers, can be extended to two years with the purchase of a two year parts and labor warranty. Specify part number EWR2 ($150 net price) when ordering.
EXPORT WARRANTY - One year parts only.
EXCLUSION OF WARRANTIES
EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
LIMITATION OF REMEDIES AND DAMAGES If Buyer makes a valid and timely claim as outlined above, Glastender’s liability and Buyer’s remedies under this agreement will be limited solely to labor charges authorized and/or replacement or credit, at Glastender’s option, with respect to Products returned at Buyer’s expense within thir­ty (30) days after warranty repair. GLASTENDER’S LIABILITY WILL IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE RETURNED PRODUCTS. GLASTENDER WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF PERISHABLE PRODUCTS RESULTING FROM THE USE OF OR INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS’ INCORPORATION INTO OR BECOMING A COMPONENT OF ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS AGREEMENT.
GOVERNING LAW - JURISDICTION
The terms and conditions of an order are to be governed and construed according to the laws of the State of Michigan, without regard to conflict of laws principles. Buyer hereby consents to the jurisdiction and venue of the courts located in Saginaw County, Michigan.
No representative, distributor, dealer, or any other person is authorized to modify this warranty. This warranty replaces all other written or verbal warranties.
NOTE: Glastender, Inc.’s policy of constant quality improvement means that prices, specifications, and policies are subject to change without notice. Questions regarding this warranty should be directed to Glastender’s Warranty Administrator.
01-12-16
IMPORTANT!!
Attention Service Companies
Please review the important warranty information on this page. If you believe a service call should be covered by the factory, please call the factory for authorization between 8AM and 5PM EST, Monday through Friday.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
4
installation
introDuction
This manual describes the operational features of Vertical Door Coolers. Please review this information before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for selecting Glastender, Inc. products.
utility reQuireMents anD connections
Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 6-foot grounded cord and plug is included with self-contained models.
Plumbing:
required.
through one of the 3/4 Self-contained Keg Coolers: The drain pain drain is pre-plumbed at the factory to stub out below
the compressor compartment. A field connection to an external drain must be made from that point.
uncrating anD start-uP instructions
All models are shipped in one carton. These steps should be followed:
Self-contained Models: Automatic condensate evaporator is included. No drain connection
Remote Models: An external drain connection is required. Use the ten foot length of 1/2" ID by
5/8" OD plastic tubing provided to run the drain line for condensate. The tubing should exit
"
side knock-out holes.
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base if included.
3. Position unit and level and/or seal as required (see page 2 and 3).
4. The evaporator drain pan on remote models must be plumbed to an external drain. All units with draft beer must be plumbed to an external drain (except model KC24 which includes an internal plastic drain bottle). On self­contained models with draft beer and a factory installed finished top, the beer tower drain pan is plumbed through the cabinet and stubs out in the 3" space below the compressor compartment. Connection to an external drain must be made from that point.
5. Place shelves in desired location.
6. Plug into 115 volt AC outlet if a power cord is included. Remote models require electrical connections to be made by an electrician or remote refrigeration contractor.
7. Load with bottles or cans and allow time for products to cool.
8. Your Glastender equipment is now ready for use.
oPeration
The operating temperature range is 36°F (2°C) to 40°F (5°C).
Self-contained models include an automatic defrost system. The refrigerator will defrost every six hours for approximately 20 minutes. Endwall coolers will defrost every four hours for approximately 15 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off
cleaning instructions
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
Cleaning Instructions continued on page 4
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
5
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
MINIMUM CLEARANCE
installation
1" BASE
Cleaning Instructions continued from page 3
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact sur-
faces.
2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as possible.
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces,
since they will break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always
scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not
removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product
can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to prema-
ture failure, since alcohol and moisture build-up breaks down the gasket material.
sealing Vertical Door cooler to floor
To comply with NSF & health codes, the cooler base must be sealed to the floor using NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not apply to models that include legs or casters.
Side View of Cabinet
bb24 MiniMuM air floW clearance DiagraM
WARNING:
COMPRESSOR FAILURE DUE
TO RESTRICTION OR
BLOCKAGE OF AIR FLOW WILL
WARRANTY.
VOID
COMPRESSOR
COMPARTMENT
COOLER DOOR
FLOOR
BEAD SEALANT
FOR AIR FLOW
8"
7"
8 1/2"
1 1/2"
24" 21"
AIR FLOW
MAGNETIC GASKET
COOLER CABINET
8"
10"
SWING WILL CONTINUE IF NO CABINET TO IMPEDE
EVAPORATOR
HOUSING
180° SWING
Plan View
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
6
installation
skin
attention installer: WARNING!!
Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems.
COOLER WITH 6" LEGS
cooler installation checKlist
Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots?
COOLER WITHOUT LEGS
If the unit was designed for legs, are they attached?
Is the unit level at the base, from end to end?
Do the doors open and close freely, without touching any other part of the unit in travel?
Are there open holes to the outside of the cabinet which are not plugged or insulated?
Are there obstructions of any kind to air flow into or out of the condensing unit?
Is product tubing or are other lines installed in such a manner to not allow shelf access?
sPecial instructions for Keg coolers
Before you begin:
1. Disassemble the tower into three parts, stiffener, skin, and top plate,
by unscrewing the top two screws.
2. Mount the column stiffener with provided four 1/4"-20x1-1/2" bolts.
3. Install insulation provided into the bottom of the column stiffener.
4. Place the column skin over the stiffener. Run the beer lines through
the hole at the same time.
5. Install insulation provided into the top of the tower assembly.
6. Mount the column top plate to the column stiffener with the two #10-32x1/2" phillips at head s/s machine
screws provided.
7. Apply a bead of silicone sealant around the perimeter of the column. Use your nger to smooth out the bead.
8. Wash tapping device and faucet with detergent and water. Flush beer tapping device and faucet lines.
top plate
stiffener
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
7
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
cooler Design change
iMPortant Design change inforMation
In February 2004, Glastender released new BB and ND self contained cooler designs with the evaporator hous­ing moved into an area above the compressor compartment. The serial numbers for these units will be 90000 and above. As of September 2006, KC52, KC72, and KC84 model keg coolers are being manufactured as endwall models. Due to special customer request some BB and ND self contained models may not have the endwall design. Please be sure to verify which cooler design type you are ordering parts for. The term endwall will be used throughout this document to denote parts used for coolers featuring this design.
Standard cooler conguration with evaporator inside cooler area. Compressor compartment
may be located left or right.
Endwall cooler conguration (most BB and ND models manufactured after Feb. 2004, most
KC models manufactured after Sept. 2006) with evaporator located in housing above the compressor compartment. Compressor compartment may be located left or right.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
8
electrical anD refrigeration sPecifications
bb24 self-containeD & Kc24 ManufactureD after 4/14/06
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
4.0 full load amps, 1/6 HP R134a 5.0 oz. 200 85
Kc24 ManufactureD before 4/14/06
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
2.8 full load amps, 1/6 HP R134a 5.0 oz. 200 85
fV24, fV48, anD bb36 self-containeD MoDels ManufactureD before 2/04
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
5.1 full load amps, 1/5 HP R22 13.5 oz. 285 144
bb24 reMote, bb48, bb72, bb96, lP48, lP72, lP96, Pt48, Pt72, Pt96
lectrical refrigerant Pressure P.s.i.g.
e
115V, 1 phase, 60 Hz tyPe charge high loW R22 n/a n/a n/a
lP60,
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
8.8 full load amps, 1/3 HP R22 13.5 oz. 285 144
lP84, lP108 & non-enDWall bb60, bb84, bb108, Kc48, Kc72, & Kc84
PT60, PT84
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
8.8 full load amps, 1/3 HP R404a 9.0 oz. 285 144
PT108
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
8.8 full load amps, 1/3 HP R404a 10.0 oz. 285 144
bb36, bb60, nD52, Kc52 enDWall MoDels
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
7.2 full load amps, 1/3 HP R134a *12.0 oz. 186 88
* 12.0 oz. charge Serial #134-106565-F and after. 20.0 oz. charge prior to Serial #134-106565-F.
bb84, bb108, nD72, nD92, Kc72, Kc84 enDWall MoDels
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
10.1 full load amps, 1/3 HP R404a 16.0 oz. 331 174
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
9
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
Wiring DiagraM for bb36, bb60, nD52, & Kc52 enDWall MoDels
WHITE
LIGHT RECEPTICAL AUX. RECEPTICAL
DEFROST TIMER
BLACK
WHITE
EVAPORATOR FAN
BLUE
WHITE
BLUE
WHITE
THERMOSTAT
ORANGE
MAIN
POWER
SUPPLY
CORD
115v AC
15amp
BLACK
LIGHT SWITCH
BLACK
WHITE
GREEN
CONDENSER FAN
BLACK
COMMON
RUN
COMPRESSOR
START
BLACK
WHITE
OVERLOAD
BLACK
RELAY
STARTER
BLUE
BLUE
Wiring DiagraM for MoDels bb84, bb108,
nD72, nD92, Kc72, & Kc84 e
nDWall MoDels
2 143
ORANGE
MAIN POWER SUPPLY
CORD
115v AC
15amp
WHITE
LIGHT RECEPTICAL AUX. RECEPTICAL
BLACK
BLACK
LIGHT SWITCH
BLACK
WHITE
GREEN
CONDENSER FAN
BLACK
COMMON
RUN
COMPRESSOR
START
BLACK
WHITE
OVERLOAD
RELAY
STARTER
BLUE
BLUE
EVAPORATOR FAN
BLUE
BLACK
DEFROST TIMER
WHITE
2 143
WHITE
BLUE
WHITE
ORANGE
THERMOSTAT
ORANGE
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
10