Gigabyte gv-nx66256dp_10_pvt Schematics

1
P229-B02 DESIGN
2
3
4
5
6
7
8
HGFEDCBA
1
A A
PAGE SUMMARY:
2
B B
3
C C
REVISION HISTORY:
X1
Initial Release
1
2
3
4
SKU
BASE
B
nv43dvivgatv128m16x
1 2
nv43dvivgatv128m8x
3
43gldvivgatv128m8x
4
nv43dvivgatv256m16x
5
<UNDEFINED>
6
<UNDEFINED>
7
<UNDEFINED>
8
<UNDEFINED>
9
<UNDEFINED>
10
<UNDEFINED>
11
<UNDEFINED> <UNDEFINED>
12
<UNDEFINED>
D D
5
ASSEMBLY
ALL NVIDIA DESIGN SPECIFICATIONS, REFERENCE SPECIFICATIONS, REFERENCE BOARDS, FILES, DRAWINGS, DIAGNOSTICS, LISTS AND OTHER DOCUMENTS OR INFORMATION (TOGETHER AND SEPARATELY, 'MATERIALS') ARE BEING PROVIDED 'AS IS'. THE MATERIALS MAY CONTAIN KNOWN AND UNKNOWN VIOLATIONS OR DEVIATIONS OF INDUSTRY STANDARDS AND SPECIFICATIONS. NVIDIA MAKES NO WARRANTIES, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE WITH RESPECT TO THE MATERIALS OR O THERWISE, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARR ANTIES INCLU DING, WITHOU T LIMITATION, THE WARRANTIES OF DESIGN, OF NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING, TRADE USAGE, TRADE PRACTICE, OR INDUSTRY STANDARDS.
A B D F H
1
2
3
PAGE DETAIL
4
13
<UNDEFINED>
14
<UNDEFINED>
15
BASE LEVEL GENERIC SCHEMATIC ONLY, COMMON & NO_STUFF ASSEMBLY NOTES AND BOM NOT FINAL PAGE SUMMARY
NVPN
602-10229-BASE-SCH 602-10229-0002-101 602-10229-0003-101 602-50229-0001-101 602-10229-0004-101 <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED>
E GC
5
BASE LEVEL GENERIC SCHEMATIC ONLY, COMMON & NO_STUFF ASSEMBLY NOTES AND BOM NOT FINAL P229-B02 NV43 GEN DVI-I/VGA/HD TV 128MB 16Mx16 TSOP P229-B02 NV43 GEN DVI-I/VGA/HDT V 128MB 8Mx16 TSOP P229-B02 NV43-GL GEN DVI-I/VGA/HD TV 128MB 8Mx16 TSOP P229-B02 NV43 GEN DVI-I/VGA/HD TV 256MB 16Mx16 TSOP <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED>
6
星期四, 十月 28, 2004
GIGABYTE
P229-B02 DESIGN
GV-NX66256DP
Title
Size Document Number Rev
Custom
Date: Sheet of
7
1.0
116
8
4
5
1
16X PCIe Interface
3V3AUX
C39 .100UF
25V 10% X7R 0603
1
COMMON
A A
GND
PRSNT
NTP_PE_PRSNT2_A
NTP_PE_RSVD2
2
NTP_PE_PRSNT2_B NTP_PE_RSVD3 NTP_PE_RSVD4 NTP_PE_RSVD5
B B
NTP_PE_PRSN T2_C NTP_PE_RSVD6
3
NTP_PE_RSVD7 NTP_PE_RSVD8
C C
4
D D
5
ALL NVIDIA DESIGN SPECIFICATIONS, REFERENCE SPECIFICATIONS, REFERENCE BOARDS, FILES, DRAWINGS, DIAGNOSTICS, LISTS AND OTHER DOCUMENTS OR INFORMATION (TOGETHER AND SEPARATELY, 'MATERIALS') ARE BEING PROVIDED 'AS IS'. THE MATERIALS MAY CONTAIN KNOWN AND UNKNOWN VIOLATIONS OR DEVIATIONS OF INDUSTRY STANDARDS AND SPECIFICATIONS. NVIDIA MAKES NO WARRANTIES, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE WITH RESPECT TO THE MATERIALS OR O THERWISE, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARR ANTIES INCLU DING, WITHOU T LIMITATION, THE WARRANTIES OF DESIGN, OF NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING, TRADE USAGE, TRADE PRACTICE, OR INDUSTRY STANDARDS.
CN1
NONPHY-X16
COMMON
12V_PEX
B1
+12V
B2
+12V
A2
+12V
A3
+12V
B3
+12V/RSVD
3V3_PEX
B8
+3V3
A9
+3V3
A10
+3V3
3V3AUX
B10
+3V3AUX
A1
PRSNT1
B17
PRSNT2
B12
RSVD
B4
GND
A4
GND
B7
GND
A12
GND
B13
GND
A15
GND
B16
GND
B18
GND
A18
GND
GND
B31
PRSNT2
A19
RSVD
B30
RSVD
A32
RSVD
A20
GND
B21
GND
B22
GND
A23
GND
A24
GND
B25
GND
B26
GND
A27
GND
A28
GND
B29
GND
A31
GND
B32
GND
GND
B48
PRSNT2
A33
RSVD
A34
GND
B35
GND
B36
GND
A37
GND
A38
GND
B39
GND
B40
GND
A41
GND
A42
GND
B43
GND
B44
GND
A45
GND
A46
GND
B47
GND
B49
GND
A49
GND
GND
B81
PRSNT2
A50
RSVD
B82
RSVD
A51
GND
B52
GND
B53
GND
A54
GND
A55
GND
B56
GND
B57
GND
A58
GND
A59
GND
B60
GND
B61
GND
A62
GND
A63
GND
B64
GND
B65
GND
A66
GND
A67
GND
B68
GND
B69
GND
A70
GND
A71
GND
B72
GND
B73
GND
A74
GND
A75
GND
B76
GND
B77
GND
A78
GND
A79
GND
B80
GND
A82
GND
GND
A B D F H
1
END OF X1
END OF X4
END OF X8
END OF X16
TRST* JTAG1
TCLK JTAG2
TDI JTAG3 TDO JTAG4 TMS JTAG5
SMCLK SMDAT
PERST
REFCLK REFCLK
PERP0 PERN0
PETP0 PETN0
PERP1 PERN1
PETP1 PETN1
PERP2 PERN2
PETP2 PETN2
PERP3 PERN3
PETP3 PETN3
PERP4 PERN4
PETP4 PETN4
PERP5 PERN5
PETP5 PETN5
PERP6 PERN6
PETP6 PETN6
PERP7 PERN7
PETP7 PETN7
PERP8 PERN8
PETP8 PETN8
PERP9 PERN9
PETP9 PETN9
PERP10 PERN10
PETP10 PETN10
PERP11 PERN11
PETP11 PETN11
PERP12 PERN12
PETP12 PETN12
PERP13 PERN13
PETP13 PETN13
PERP14 PERN14
PETP14 PETN14
PERP15 PERN15
PETP15 PETN15
WAKE
2
12V_PEX
C706
C31 .100UF
.01UF
16V
25V
10%
10%
X7R
X7R
0402
0603
COMMON
COMMON
TP_PEXJTAG_TRST*
B9
TP_PEXJTAG_TCLK
A5
PEXJTAG_TDIO
A6
R571
A7
0402
A8
TP_PEXJTAG_TMS
NTP_PEX_SMCLK
B5
NTP_PEX_SMDAT
B6
NTP_PEX_WAKE*
B11
A11
A13 A14
A16 A17
B14 B15
A21 A22
B19 B20
A25 A26
B23 B24
A29 A30
B27 B28
A35 A36
B33 B34
A39 A40
B37 B38
A43 A44
B41 B42
A47 A48
B45 B46
A52 A53
B50 B51
A56 A57
B54 B55
A60 A61
B58 B59
A64 A65
B62 B63
A68 A69
B66 B67
A72 A73
B70 B71
A76 A77
B74 B75
A80 A81
B78 B79
5%
PEX_RESET_IN*
PEX_REFFCLK
PEX_REFFCLK*
PEX_TXX0 PEX_TXX0*
PEX_RX0*
PEX_TXX1 PEX_TXX1*
PEX_RX1*
PEX_TXX2 PEX_TXX2*
PEX_RX2*
PEX_TXX3 PEX_TXX3*
PEX_RX3*
PEX_TXX4 PEX_TXX4*
PEX_RX4*
PEX_TXX5 PEX_TXX5*
PEX_RX5*
PEX_TXX6 PEX_TXX6*
PEX_RX6*
PEX_TXX7 PEX_TXX7*
PEX_TXX8
PEX_RX8*
PEX_TXX9 PEX_TXX9*
PEX_RX9*
PEX_TXX10 PEX_TXX10*
PEX_RX10
PEX_RX10*
PEX_TXX11 PEX_TXX11*
PEX_RX11
PEX_RX11*
PEX_TXX12 PEX_TXX12*
PEX_RX12
PEX_RX12*
PEX_TXX13 PEX_TXX13*
PEX_RX13
PEX_RX13*
PEX_TXX14 PEX_TXX14*
PEX_RX14
PEX_RX14*
PEX_TXX15 PEX_TXX15*
PEX_RX15
PEX_RX15*
0/X
DNP
PEX_RX0
PEX_RX1
PEX_RX2
PEX_RX3
PEX_RX4
PEX_RX5
PEX_RX6
PEX_TXX8*
PEX_RX8
PEX_RX9
Place Close to fingers
3V3_PEX
5 1
2
U505
3
SC70-5 COMMON
GND
C692
COMMON 1 0VX5R
10% 0402
C690
X5R 10V0402COMMON 10%
C683
C679
10% 0402X5RCOMMON 1 0V
C666
C662 .1UF
C650
10%X5RCOMMON 1 0V
C634
COMMON 10% 0402 10V
X5R
C603
COMMON X5R 10% 0402
C586
COMMON X5R 10% 0402 10V
C567
COMMON X5R 10% 0402 10V
C547
COMMON X5R 10% 0402 10V
C541
COMMON X5R 10% 0402
C530
COMMON X5R 10% 0402 10V
C526
COMMON X5R 10% 0402 10V
C523
COMMON X5R 10% 0402 10V
R638
4
040210%COMMON X5R
0402COMMON X5R 10% 10V
0402
0402
5%
PEX_RESET_BUF_IN*
.1UF
.1UF
.1UF
10V
.1UF
.1UF
10VCOMMON X5R 10% 0402
.1UF
.1UF
.1UF
10V
.1UF
.1UF
.1UF
.1UF
10V
.1UF
.1UF
.1UF
2
C34 1UF
16V 10% X5R 0603 COMMON
GND
0/X
COMMON
R6395%100
COMMON0402
R528 200/X
C693 0/4
C691 .1UF
C689
C682
C678
0402
C664
C659
0402 10V
C649
C626
C599
0402 X5R
C579
C558
C545
0402 10V 10% X5R
C535
0402 10V 10%
C527
C525
C522
3
3V3_PEX
C699 .01UF
16V 10% X7R 0402 COMMON
R640 10K
5% 0402 COMMON
GND
PEX_TSTCLK*
DNP1%0402
C697 0/4
X5R10%
10V0402
.1UF
10% COMMON10V0402
.1UF
.1UF
.1UF
.1UF
10% COMMONX5R
.1UF
.1UF
10%10V
.1UF
.1UF
10V0402 10% COMMON
.1UF
.1UF
.1UF
.1UF
10V0402
.1UF
.1UF
3
C700 .1UF
10V 10% X5R 0402 COMMON
PEX_RESET_GPU_IN*
NTP_PD_VDDQ NTP_PU_GND
PEX_TSTCLK PEX_TSTCLK*
PEX_REFCLK
0402 10V 10% X5R COMMON
COMMON
PEX_TX0 PEX_TX0*
COMMON10%10V X5R0402
PEX_TX1 PEX_TX1*
X5R
PEX_TX2 PEX_TX2*
COMMON10%10V0402 X5R
PEX_TX3 PEX_TX3*
COMMON10%10V X5R
PEX_TX4 PEX_TX4*
COMMONX5R0402 10V 10%
PEX_TX5 PEX_TX5*
PEX_TX6 PEX_TX6*
X5R COMMON0402 10V 10%
PEX_TX7 PEX_TX7*
X5R COMMON0402
PEX_TX8 PEX_TX8*
COMMON10%10V
PEX_TX9 PEX_TX9*
X5R
PEX_TX10 PEX_TX10*
COMMON0402 10V 10%
X5R
PEX_TX11 PEX_TX11*
COMMON
PEX_TX12 PEX_TX12*
COMMONX5R
PEX_TX13 PEX_TX13*
X5R COMMON10%
PEX_TX14 PEX_TX14*
X5R0402 10%
COMMON10V
PEX_TX15 PEX_TX15*
COMMON0402 10V 10%
X5R
GND
PEX_REFCLK*
C698 1UF
16V 10% X5R 0603 COMMON
AH15
AG12 AH13
AM12 AM11
AH14 AJ14
AJ15 AK15
AK13 AK14
AH16 AG16
AM14 AM15
AG17 AH17
AL15 AL16
AG18 AH18
AK16 AK17
AK18 AJ18
AL17 AL18
AJ19 AH19
AM18 AM19
AG20 AH20
AK19 AK20
AG21 AH21
AL20 AL21
AK21 AJ21
AM21 AM22
AJ22 AH22
AK22 AK23
AG23 AH23
AL23 AL24
AK24 AJ24
AM24 AM25
AJ25 AH25
AK25 AK26
AH26 AG26
AL26 AL27
AK27 AJ27
AM27 AM28
AJ28 AH27
AL28 AL29
U7H
BGA820 COMMON
1/14 PCI_EXPRESS
PEX_RST
RFU RFU
PEX_TSTCLK_OUT PEX_TSTCLK_OUT
PEX_REFCLK PEX_REFCLK
PEX_TX0 PEX_TX0
PEX_RX0 PEX_RX0
PEX_TX1 PEX_TX1
PEX_RX1 PEX_RX1
PEX_TX2 PEX_TX2
PEX_RX2 PEX_RX2
PEX_TX3 PEX_TX3
PEX_RX3 PEX_RX3
PEX_TX4 PEX_TX4
PEX_RX4 PEX_RX4
PEX_TX5 PEX_TX5
PEX_RX5 PEX_RX5
PEX_TX6 PEX_TX6
PEX_RX6 PEX_RX6
PEX_TX7 PEX_TX7
PEX_RX7 PEX_RX7
PEX_TX8 PEX_TX8
PEX_RX8 PEX_RX8
PEX_TX9 PEX_TX9
PEX_RX9 PEX_RX9
PEX_TX10 PEX_TX10
PEX_RX10 PEX_RX10
PEX_TX11 PEX_TX11
PEX_RX11 PEX_RX11
PEX_TX12 PEX_TX12
PEX_RX12 PEX_RX12
PEX_TX13 PEX_TX13
PEX_RX13 PEX_RX13
PEX_TX14 PEX_TX14
PEX_RX14 PEX_RX14
PEX_TX15 PEX_TX15
PEX_RX15 PEX_RX15
4
4
ASSEMBLY PAGE DETAIL
5
Place near balls
160mA
PEX_IO_VDD
C571 .022UF
PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD
PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ
VDD_LP VDD_LP VDD_LP VDD_LP VDD_LP VDD_LP
VDD_SENSE GND_SENSE
VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33
PEX_PLLAVDD PEX_PLLDVDD
PEX_PLLGND
AD23 AF23 AF24 AF25 AG24 AG25
AC16 AC17 AC21 AC22 AE18 AE21 AE22 AF12 AF18 AF21 AF22
K16
VDD
K17
VDD
N13
VDD
N14
VDD
N16
VDD
N17
VDD
N19
VDD
P13
VDD
P14
VDD
P16
VDD
P17
VDD
P19
VDD
R16
VDD
R17
VDD
T13
VDD
T14
VDD
T15
VDD
T18
VDD
T19
VDD
U13
VDD
U14
VDD
U15
VDD
U18
VDD
U19
VDD
V16
VDD
V17
VDD
W13
VDD
W14
VDD
W16
VDD
W17
VDD
W19
VDD
Y13
VDD
Y14
VDD
Y16
VDD
Y17
VDD
Y19
VDD
Y20
VDD
P20 T20 T23 U20 U23 W20
N20 M21
AC11 AC12 AC24 AD24 AE11 AE12 H7 J7 K7 L10 L7 L8 M10
AF15 AE15 AE16
16V 10% X7R 0402 COMMON
1280mA
C588 .022UF
16V 10% X7R 0402 COMMON
Place near balls
Place near balls
7000mA ?
GND
PEX_PLL_AVDD PEX_PLL_DVDD
AGPVDDQ
C585
0.1UF
16V 10% X7R 0402 COMMON
C595
0.1UF
16V 10% X7R 0402 COMMON
C619
0.1UF
16V 10% X7R 0402 COMMON
GND
NTP_G3_NC0
AM8
NC
NTP_G3_NC1
AM9
NC
NTP_G3_NC2
B32
NC
NTP_G3_NC3
J6
NC
BASE LEVEL GENERIC SCHEMATIC ONLY, COMMON & NO_STUFF ASSEMBLY NOTES AND BOM NOT FINAL PCI EXPRESS, VDD, VDD33, VDD_LP
E GC
5
C559 .022UF
16V 10% X7R 0402 COMMON
C612 .022UF
16V 10% X7R 0402 COMMON
PEX_PLL_AVDD
20mA
C591
0.1UF
16V 10% X7R 0402 COMMON
C601
0.1UF
16V 10% X7R 0402 COMMON
C582
0.1UF
16V 10% X7R 0402 COMMON
Place near balls
C620 .1UF
10V 10% X5R 0402 COMMON
C616 .1UF
10V 10% X5R 0402 COMMON
Place near balls
180mA
Place near balls
C602 4700PF
25V X7R 0402 COMMON
C546 .022UF
16V 10% X7R 0402 COMMON
C576 .01UF
16V 10% X7R 0402 COMMON
C572
0.1UF
16V 10% X7R 0402 COMMON
C598 .1UF
10V 10% X5R 0402 COMMON
10%
C609
0.47UF
6.3V 10% X5R 0402 COMMON
C615
0.47UF
6.3V 10% X5R 0402 COMMON
C577
0.47UF
6.3V 10% X5R 0402 COMMON
C636 4700PF
25V 10% X7R 0402 COMMON
C631 4700PF
25V 10% X7R 0402 COMMON
C611 .01UF
16V X7R 0402 COMMON
C573
0.1UF
16V 10% X7R 0402 COMMON
C578 .01UF
16V 10% X7R 0402 COMMON
Place Close to GPU
220R@100MHz
C607
0.47UF
6.3V 10% X5R 0402 COMMON
C608
0.47UF
6.3V 10% X5R 0402 COMMON
C605
0.47UF
6.3V 10% X5R 0402 COMMON
C647 .022UF
16V 10% X7R 0402 COMMON
C625 .022UF
16V 10% X7R 0402 COMMON
C597 .01UF
10%
16V X7R 0402 COMMON
10%
LB501
C550
4.7UF
6.3V X5R 0603 COMMON
C592 .01UF
16V 10% X7R 0402 COMMON
C563
0.47UF
6.3V 10% X5R 0402 COMMON
Place Near BGA
20%
Place Near BGA
6
COMMONBEAD_0603
PEX1V2
GND
C713 10UF
6.3V 20% X5R 0805 COMMON
GND
NVVDD
C581 10UF
6.3V 20% X5R 0805 COMMON
C622 10UF
6.3V
GND
20% X5R 0805 COMMON
C584
0.47UF
6.3V 10% X5R 0402 COMMON
LB504 220R@100MHz
C565
4.7UF
6.3V 20% X5R 0603 COMMON
C648 .022UF
16V 10% X7R 0402 COMMON
C552 .022UF
16V 10% X7R 0402 COMMON
C587
4.7UF
20%6.3V X5R 0603 COMMON
GND
C610
4.7UF
20%
6.3V X5R 0603 COMMON
6
C549
4.7UF
6.3V X5R 0603 COMMON
C594 10UF
6.3V 20% X5R 0805 COMMON
3V3
GND
GND
PEX1V2
20%
Place Close to GPU
COMMONBEAD_0603
C665 1UF
16V 10% X5R 0603 COMMON
LB505
LB506
C618 .01UF
16V 10% X7R 0402 COMMON
GND
GND
GND
150-220R@100MHz
COMMONBEAD_0603
150-220R@100MHz
COMMONBEAD_0603
C604
4.7UF
6.3V 20% X5R 0603 COMMON
C596 .01UF
16V 10% X7R 0402 COMMON
NVVDD
NVVDD
7
NET RULES
PEX_TX0 PEX_TX0* PEX_TX1 PEX_TX1* PEX_TX2 PEX_TX2* PEX_TX3 PEX_TX3* PEX_TX4 PEX_TX4* PEX_TX5 PEX_TX5*
C617 .01UF
16V 10% X7R 0402 COMMON
GND
PEX1V2
C574
4.7UF
20%
6.3V X5R 0603 COMMON
PEX_TX6 PEX_TX6* PEX_TX7 PEX_TX7* PEX_TX8 PEX_TX8* PEX_TX9 PEX_TX9* PEX_TX10 PEX_TX10* PEX_TX11 PEX_TX11* PEX_TX12 PEX_TX12* PEX_TX13 PEX_TX13* PEX_TX14 PEX_TX14* PEX_TX15 PEX_TX15*
PEX_TXX0 PEX_TXX0* PEX_TXX1 PEX_TXX1* PEX_TXX2 PEX_TXX2* PEX_TXX3 PEX_TXX3* PEX_TXX4 PEX_TXX4* PEX_TXX5 PEX_TXX5* PEX_TXX6 PEX_TXX6* PEX_TXX7 PEX_TXX7* PEX_TXX8 PEX_TXX8* PEX_TXX9 PEX_TXX9* PEX_TXX10 PEX_TXX10* PEX_TXX11 PEX_TXX11* PEX_TXX12 PEX_TXX12* PEX_TXX13 PEX_TXX13* PEX_TXX14 PEX_TXX14* PEX_TXX15 PEX_TXX15*
PEX_RX0 PEX_RX0* PEX_RX1 PEX_RX1* PEX_RX2 PEX_RX2* PEX_RX3 PEX_RX3* PEX_RX4 PEX_RX4* PEX_RX5 PEX_RX5* PEX_RX6 PEX_RX6*PEX_RX7 PEX_RX7PEX_R X7* PEX_RX7* PEX_RX8 PEX_RX8* PEX_RX9 PEX_RX9* PEX_RX10 PEX_RX10* PEX_RX11 PEX_RX11* PEX_RX12 PEX_RX12* PEX_RX13 PEX_RX13* PEX_RX14 PEX_RX14* PEX_RX15 PEX_RX15*
PEX_REFCLK PEX_REFCLK* PEX_TSTCLK PEX_TSTCLK* PEX_REFFCLK PEX_REFFCLK*
Net Name MIN_LINE_WIDTH NET_SPACING_TYPE
AGPVDDQ PEX_IO_VDD PEX_PLL_AVDD PEX_PLL_DVDD
PEX_TX0 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX1 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX1 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX2 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX2 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX3 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX3 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX4 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX4 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX5 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX5 2 0MIL_G2G_30MIL_USER_DIFF
PEX_TX6 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX7 2 0MIL_G2G_30MIL_USER_DIFF
PEX_TX8 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX8 2 0MIL_G2G_30MIL_USER_DIFF PEX_TX9 2 0MIL_G2G_30MIL_USER_DIFF
PEX_TX10 20MIL_G2G_30MIL_USER_DIFF
PEX_TX11 20MIL_G2G_30MIL_USER_DIFF PEX_TX11 20MIL_G2G_30MIL_USER_DIFF PEX_TX12 20MIL_G2G_30MIL_USER_DIFF PEX_TX12 20MIL_G2G_30MIL_USER_DIFF PEX_TX13 20MIL_G2G_30MIL_USER_DIFF PEX_TX13 20MIL_G2G_30MIL_USER_DIFF PEX_TX14 20MIL_G2G_30MIL_USER_DIFF PEX_TX14 20MIL_G2G_30MIL_USER_DIFF PEX_TX15 20MIL_G2G_30MIL_USER_DIFF PEX_TX15 20MIL_G2G_30MIL_USER_DIFF
PEX_TXX0 20M IL_G2G_30MIL_USER_DIFF PEX_TXX0 20M IL_G2G_30MIL_USER_DIFF PEX_TXX1 20M IL_G2G_30MIL_USER_DIFF
PEX_TXX2 20M IL_G2G_30MIL_USER_DIFF
PEX_TXX3 20M IL_G2G_30MIL_USER_DIFF
PEX_TXX4 20M IL_G2G_30MIL_USER_DIFF PEX_TXX5 20M IL_G2G_30MIL_USER_DIFF PEX_TXX5 20M IL_G2G_30MIL_USER_DIFF PEX_TXX6 20M IL_G2G_30MIL_USER_DIFF
PEX_TXX7 20M IL_G2G_30MIL_USER_DIFF
PEX_TXX8 20M IL_G2G_30MIL_USER_DIFF PEX_TXX9 20M IL_G2G_30MIL_USER_DIFF PEX_TXX9 20M IL_G2G_30MIL_USER_DIFF PEX_TXX10 20MIL_G2G_30MIL_USER_DIFF PEX_TXX10 20MIL_G2G_30MIL_USER_DIFF PEX_TXX11 20MIL_G2G_30MIL_USER_DIFF
PEX_TXX12 20MIL_G2G_30MIL_USER_DIFF
PEX_TXX13 20MIL_G2G_30MIL_USER_DIFF PEX_TXX13 20MIL_G2G_30MIL_USER_DIFF
PEX_TXX14 20MIL_G2G_30MIL_USER_DIFF PEX_TXX15 20MIL_G2G_30MIL_USER_DIFF PEX_TXX15 20MIL_G2G_30MIL_USER_DIFF
PEX_RX0 20MI L_G2G_30MIL_USER_DIFF PEX_RX0 20MI L_G2G_30MIL_USER_DIFF PEX_RX1 20MI L_G2G_30MIL_USER_DIFF
PEX_RX2 20MI L_G2G_30MIL_USER_DIFF PEX_RX2 20MI L_G2G_30MIL_USER_DIFF PEX_RX3 20MI L_G2G_30MIL_USER_DIFF
PEX_RX4 20MI L_G2G_30MIL_USER_DIFF PEX_RX5 20MI L_G2G_30MIL_USER_DIFF PEX_RX5 20MI L_G2G_30MIL_USER_DIFF PEX_RX6 20MI L_G2G_30MIL_USER_DIFF PEX_RX6 20MI L_G2G_30MIL_USER_DIFF PEX_RX7 20MI L_G2G_30MIL_USER_DIFF PEX_RX7 20MI L_G2G_30MIL_USER_DIFF
PEX_RX10 20M IL_G2G_30MIL_USER_DIFF PEX_RX10 20M IL_G2G_30MIL_USER_DIFF PEX_RX11 20M IL_G2G_30MIL_USER_DIFF PEX_RX11 20M IL_G2G_30MIL_USER_DIFF PEX_RX12 20M IL_G2G_30MIL_USER_DIFF PEX_RX12 20M IL_G2G_30MIL_USER_DIFF PEX_RX13 20M IL_G2G_30MIL_USER_DIFF PEX_RX13 20M IL_G2G_30MIL_USER_DIFF
PEX_RX14 20M IL_G2G_30MIL_USER_DIFF PEX_RX15 20M IL_G2G_30MIL_USER_DIFF PEX_RX15 20M IL_G2G_30MIL_USER_DIFF
PEX_REFCLK 20MIL_G2G_30MIL_USER_DI FF
PEX_REFFCLK 20MIL_G2G_30MIL_USER_DI FF
8
HGFEDCBA
NET_SPACING_RULEDIFFPAIRNET
20MIL_G2G_30MIL_USER_DI FFPEX_TX0
20MIL_G2G_30MIL_USER_DI FFPEX_TX6
20MIL_G2G_30MIL_USER_DI FFPEX_TX7
20MIL_G2G_30MIL_USER_DI FFPEX_TX9
20MIL_G2G_30MIL_USER_DI FFPEX_TX10
20MIL_G2G_30MIL_USER_DI FFPEX_TXX1
20MIL_G2G_30MIL_USER_DI FFPEX_TXX2
20MIL_G2G_30MIL_USER_DI FFPEX_TXX3 20MIL_G2G_30MIL_USER_DI FFPEX_TXX4
20MIL_G2G_30MIL_USER_DI FFPEX_TXX6
20MIL_G2G_30MIL_USER_DI FFPEX_TXX7 20MIL_G2G_30MIL_USER_DI FFPEX_TXX8
20MIL_G2G_30MIL_USER_DI FFPEX_TXX11
20MIL_G2G_30MIL_USER_DI FFPEX_TXX12
20MIL_G2G_30MIL_USER_DI FFPEX_TXX14
1
2
3
20MIL_G2G_30MIL_USER_DI FFPEX_RX1
20MIL_G2G_30MIL_USER_DI FFPEX_RX3 20MIL_G2G_30MIL_USER_DI FFPEX_RX4
20MIL_G2G_30MIL_USER_DI FFPEX_RX8 20MIL_G2G_30MIL_USER_DI FFPEX_RX8 20MIL_G2G_30MIL_USER_DI FFPEX_RX9 20MIL_G2G_30MIL_USER_DI FFPEX_RX9
20MIL_G2G_30MIL_USER_DI FFPEX_RX14
20MIL_G2G_30MIL_USER_DI FFPEX_REFCLK 20MIL_G2G_30MIL_USER_DI FFPEX_TSTCLK 20MIL_G2G_30MIL_USER_DI FFPEX_TSTCLK
20MIL_G2G_30MIL_USER_DI FFPEX_REFFCLK
10MIL16 10MIL16 10MIL12 10MIL12
4
AGPVDDQ
5
GND
星期四, 十月 28, 2004
GIGABYTE
16X PCIe Interface
GV-NX66256DP
1.0
216
8
Title
Size Document Number Rev
Custom
Date: Sheet of
7
1
FB BANK A
OUT
BI
C528 .1UF/X
10V 10% X5R 0402 DNP
C529 .1UF
10V 10% X5R 0402 COMMON
DDR2:
DDR3:
FBAD[63..0]
BI
FBADQM[7..0]
FBADQS[7..0]
VREF = FB VDDQ * Rbot/(Rtop + Rbot)
VREF = 0.50 * FBVDDQ
0.9V = 1.8V * 1.0K/1.0K + 1.0K)
VREF = 0.70 * FBVDDQ
1.26V = 1.8V * 2.7K/()1.15K + 2.7K)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
0
FBADQM0
1
FBADQM1
2
FBADQM2
3
FBADQM3
4
FBADQM4
5
FBADQM5
6
FBADQM6
7
FBADQM7
0
FBADQS0
1
FBADQS1
2
FBADQS2
3
FBADQS3
4
FBADQS4
5
FBADQS5
6
FBADQS6
7
FBADQS7
NTP_FBADQS_RN<0> NTP_FBADQS_RN<1> NTP_FBADQS_RN<2> NTP_FBADQS_RN<3> NTP_FBADQS_RN<4> NTP_FBADQS_RN<5> NTP_FBADQS_RN<6> NTP_FBADQS_RN<7>
5<> 6<>
1
A A
2
B B
3
5< 6<
5< 6<
C C
FBVDDQ
4
1K
Rtop
1%
0402 COMMON
R519
1K
COMMON
Rbot
1%
0402
R520
GND
D D
5
FB_VREF1
2
U7B
BGA820 COMMON
FBAD0 FBAD1 FBAD2 FBAD3 FBAD4 FBAD5 FBAD6 FBAD7 FBAD8 FBAD9 FBAD10 FBAD11 FBAD12 FBAD13 FBAD14 FBAD15 FBAD16 FBAD17 FBAD18 FBAD19 FBAD20 FBAD21 FBAD22 FBAD23 FBAD24 FBAD25 FBAD26 FBAD27 FBAD28 FBAD29 FBAD30 FBAD31 FBAD32 FBAD33 FBAD34 FBAD35 FBAD36 FBAD37 FBAD38 FBAD39 FBAD40 FBAD41 FBAD42 FBAD43 FBAD44 FBAD45 FBAD46 FBAD47 FBAD48 FBAD49 FBAD50 FBAD51 FBAD52 FBAD53 FBAD54 FBAD55 FBAD56 FBAD57 FBAD58 FBAD59 FBAD60 FBAD61 FBAD62 FBAD63
2/14 FBA
N27
FBAD0
M27
FBAD1
N28
FBAD2
L29
FBAD3
K27
FBAD4
K28
FBAD5
J29
FBAD6
J28
FBAD7
P30
FBAD8
N31
FBAD9
N30
FBAD10
N32
FBAD11
L31
FBAD12
L30
FBAD13
J30
FBAD14
L32
FBAD15
H30
FBAD16
K30
FBAD17
H31
FBAD18
F30
FBAD19
H32
FBAD20
E31
FBAD21
D30
FBAD22
E30
FBAD23
H28
FBAD24
H29
FBAD25
E29
FBAD26
J27
FBAD27
F27
FBAD28
E27
FBAD29
E28
FBAD30
F28
FBAD31
AD29
FBAD32
AE29
FBAD33
AD28
FBAD34
AC28
FBAD35
AB29
FBAD36
AA30
FBAD37
Y28
FBAD38
AB30
FBAD39
AM30
FBAD40
AF30
FBAD41
AJ31
FBAD42
AJ30
FBAD43
AJ32
FBAD44
AK29
FBAD45
AM31
FBAD46
AL30
FBAD47
AE32
FBAD48
AE30
FBAD49
AE31
FBAD50
AD30
FBAD51
AC31
FBAD52
AC32
FBAD53
AB32
FBAD54
AB31
FBAD55
AG27
FBAD56
AF28
FBAD57
AH28
FBAD58
AG28
FBAD59
AG29
FBAD60
AD27
FBAD61
AF27
FBAD62
AE28
FBAD63
M29
FBADQM0
M30
FBADQM1
G30
FBADQM2
F29
FBADQM3
AA29
FBADQM4
AK30
FBADQM5
AC30
FBADQM6
AG30
FBADQM7
L28
FBADQS_WP0
K31
FBADQS_WP1
G32
FBADQS_WP2
G28
FBADQS_WP3
AB28
FBADQS_WP4
AL32
FBADQS_WP5
AF32
FBADQS_WP6
AH30
FBADQS_WP7
M28
FBADQS_RN0
K32
FBADQS_RN1
G31
FBADQS_RN2
G27
FBADQS_RN3
AA28
FBADQS_RN4
AL31
FBADQS_RN5
AF31
FBADQS_RN6
AH29
FBADQS_RN7
E32
FB_VREF1
FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD
FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ
FBA_CMD0 FBA_CMD1 FBA_CMD2 FBA_CMD3 FBA_CMD4 FBA_CMD5 FBA_CMD6 FBA_CMD7 FBA_CMD8
FBA_CMD9 FBA_CMD10 FBA_CMD11 FBA_CMD12 FBA_CMD13 FBA_CMD14 FBA_CMD15 FBA_CMD16 FBA_CMD17 FBA_CMD18 FBA_CMD19 FBA_CMD20 FBA_CMD21 FBA_CMD22 FBA_CMD23 FBA_CMD24 FBA_CMD25 FBA_CMD26
FBA_CLK0
FBA_CLK0
FBA_CLK1
FBA_CLK1
FBA_DEBUG
FBA_REFCLK FBA_REFCLK
FBA_PLLVDD
FBA_PLLAVDD
FBA_PLLGND
3
NTP_FBVDD0
A12
NTP_FBVDD1
A15
NTP_FBVDD2
A18
NTP_FBVDD3
A21
NTP_FBVDD4
A24
NTP_FBVDD5
A27
NTP_FBVDD6
A3
NTP_FBVDD7
A30
NTP_FBVDD8
A6
NTP_FBVDD9
A9
NTP_FBVDD10
AA32
NTP_FBVDD11
AD32
NTP_FBVDD12
AG32
NTP_FBVDD13
AK32
NTP_FBVDD14
C32
NTP_FBVDD15
F32
NTP_FBVDD16
J32
NTP_FBVDD17
M32
NTP_FBVDD18
R32
NTP_FBVDD19
V32
AA25 AA26 AB25 AB26 G11 G12 G15 G18 G21 G22 H11 H12 H15 H18 H21 H22 L25 L26 M25 M26 R25 R26 V25 V26
FBAA3
P32
FBAA0
U27
FBAA2
P31
FBAA1
U30
FBBA3
Y31
FBBA4
W32
FBBA5
W31
NTP_FBACS1*
T32
FBACS0*
V27
FBAWE*
T28
FBABA0
T31
FBACKE
U32
NTP_G3A_CMD12
W29
FBBA2
W30
FBAA12
T27
FBARAS*
V28
FBAA11
V30
FBAA10
U31
FBABA1
R27
FBAA8
V29
FBAA9
T30
FBAA6
W28
FBAA5
R29
FBAA7
R30
FBAA4
P29
FBACAS*
U28
NTP_G3A_CMD26
Y32
FBACLK0
P28
FBACLK0*
R28
FBACLK1
Y27
FBACLK1*
AA27
PLACE BELOW GPU
C533 4700PF
25V 10% X7R 0402 COMMON
C540 4700PF
25V 10% X7R 0402 COMMON
C570 4700PF
25V 10% X7R 0402 COMMON
C575 4700PF
25V 10% X7R 0402 COMMON
C566 4700PF
25V 10% X7R 0402 COMMON
3 0 2
1 3 4 5
2
12
11 10
8
9
6
5
7
4
OUT
OUT
OUT
OUT
PLACE close to balls
RFU
TP_FBA_DEBUG
AC27
TP_FBA_REFCLK
D32
TP_FBA_REFCLK*
D31
FBA_PLLVDD
G23
FBA_PLLAVDD
G25
G24
NTP_FBA_DBI0
Y30
RFU
NTP_FBA_DBI1
AC26
GND
FB_DLLVDD
ON NV3x version's of G3 FB_DLLVDD will be routed on FB_PLLVDD
C532 .022UF
16V 10% X7R 0402 COMMON
C534 .022UF
16V 10% X7R 0402 COMMON
C537 .022UF
16V 10% X7R 0402 COMMON
C561 .022UF
16V 10% X7R 0402 COMMON
C580 .022UF
16V 10% X7R 0402 COMMON
4
C531
C556 4700PF
25V 10% X7R 0402 COMMON
C656 4700PF
25V 10% X7R 0402 COMMON
C600 4700PF
25V 10% X7R 0402 COMMON
C548 4700PF
25V 10% X7R 0402 COMMON
C562 .1UF
10V 10% X5R 0402 COMMON
C539 .022UF
16V 10% X7R 0402 COMMON
C652 .022UF
16V 10% X7R 0402 COMMON
C590 .022UF
16V 10% X7R 0402 COMMON
C613 .022UF
16V 10% X7R 0402 COMMON
C560 .1UF
10V 10% X5R 0402 COMMON
.1UF
10V 10% X5R 0402 COMMON
C538 .1UF
10V 10% X5R 0402 COMMON
C536 .1UF
10V 10% X5R 0402 COMMON
C606 .1UF
10V 10% X5R 0402 COMMON
C589 .1UF
10V 10% X5R 0402 COMMON
C635 .1UF
10V 10% X5R 0402 COMMON
C583 .1UF
10V 10% X5R 0402 COMMON
C614 .1UF
10V 10% X5R 0402 COMMON
C553 .1UF
10V 10% X5R 0402 COMMON
C564 220PF
50V 5% COG 0402 COMMON
FBVDDQ
5
C630 .1UF
10V 10% X5R 0402 COMMON
C551 .1UF
10V 10% X5R 0402 COMMON
C554
4.7UF
6.3V 20% X5R 0603 COMMON
C593
4.7UF
6.3V 20% X5R 0603 COMMON
6
FBACLK0
FBACLK0*
FBACLK1
FBACLK1*
GND
GND
GND
GND
FBA_PLLVDD
FBA_PLLAVDD
FB_VREF1
FBARAS*
FBACAS*
FBAWE*
FBACKE
FBACS0*
FBAD[63..0]
FBADQS[7..0]
FBADQM[7..0]
FBAA[12..0]
FBABA[1..0]
FBBA[5..2]
7
NET_SPACING_RULEDIFFPAIRNET
12 10MIL
8
HGFEDCBA
20MIL_G2G_30MILFBACLK0
20MIL_G2G_30MILFBACLK0
20MIL_G2G_30MILFBACLK1
20MIL_G2G_30MILFBACLK1
10MIL12
10MIL12
10MIL
10MIL
10MIL
10MIL
10MIL
10MIL
15MIL
10MIL
10MIL
10MIL
10MIL
1
2
GND
FBBA[5..2]
FBAA[12..0]
FBABA[1..0]
0
1
5< 5< 6< 6<
C569 .01UF
16V 10% X7R 0402 COMMON
C555 .01UF
16V 10% X7R 0402 COMMON
6<
OUT
5< 6<
OUT
5< 6<
OUT
5< 6<
OUT
5< 6<
OUT
5< 6<
OUT
5< 6<
OUT
COMMON
R518
10K
5%
0402
PLACE near GPU
LB502
150-220R@100MHz
COMMON
BEAD_0603
C568 .1UF
10V 10% X5R 0402 COMMON
LB503
150-220R@100MHz
COMMON
BEAD_0603
C557 .1UF
10V 10% X5R 0402 COMMON
5< 6<
OUT
3
GND
FBVDDQ
C513
C519
C509
C515
C514
.01UF
.01UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
A3V3
GND
.01UF
16V 10% X7R 0402 COMMON
.01UF
16V 10% X7R 0402 COMMON
.01UF
16V 10% X7R 0402 COMMON
C517 .01UF
16V 10% X7R 0402 COMMON
4
GND
NVVDD
GND
5
ASSEMBLY
ALL NVIDIA DESIGN SPECIFICATIONS, REFERENCE SPECIFICATIONS, REFERENCE BOARDS, FILES, DRAWINGS, DIAGNOSTICS, LISTS AND OTHER DOCUMENTS OR INFORMATION (TOGETHER AND SEPARATELY, 'MATERIALS') ARE BEING PROVIDED 'AS IS'. THE MATERIALS MAY CONTAIN KNOWN AND UNKNOWN VIOLATIONS OR DEVIATIONS OF INDUSTRY STANDARDS AND SPECIFICATIONS. NVIDIA MAKES NO WARRANTIES, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE WITH RESPECT TO THE MATERIALS OR O THERWISE, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARR ANTIES INCLU DING, WITHOU T LIMITATION, THE WARRANTIES OF DESIGN, OF NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING, TRADE USAGE, TRADE PRACTICE, OR INDUSTRY STANDARDS.
A B D F H
1
2
3
PAGE DETAIL
4
BASE LEVEL GENERIC SCHEMATIC ONLY, COMMON & NO_STUFF ASSEMBLY NOTES AND BOM NOT FINAL FB BANK A, FBVDDQ
E GC
5
星期四, 十月 28, 2004
GIGABYTE
FB BANK A
GV-NX66256DP
1.0
316
8
Title
Size Document Number Rev
Custom
Date: Sheet of
6
7
1
FB BANK C
BI
OUT
BI
FBVDDQ
1K
1%
0402 COMMON
R521
1K
COMMON 1%
0402
R522
GND
VREF = 0.70 * FBVDDQ
1.26V = 1.8V * 2.7K/()1.15K + 2.7K)
FBCD[63..0]
FBCDQM[7..0]
FBCDQS[7..0]
C543 .1UF/X
10V 10% X5R 0402 DNP
C544 .1UF
10V 10% X5R 0402 COMMON
7<> 8<>
1
A A
2
B B
3
7< 8<
7< 8<
C C
4
Rtop
Rbot
D D
5
ALL NVIDIA DESIGN SPECIFICATIONS, REFERENCE SPECIFICATIONS, REFERENCE BOARDS, FILES, DRAWINGS, DIAGNOSTICS, LISTS AND OTHER DOCUMENTS OR INFORMATION (TOGETHER AND SEPARATELY, 'MATERIALS') ARE BEING PROVIDED 'AS IS'. THE MATERIALS MAY CONTAIN KNOWN AND UNKNOWN VIOLATIONS OR DEVIATIONS OF INDUSTRY STANDARDS AND SPECIFICATIONS. NVIDIA MAKES NO WARRANTIES, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE WITH RESPECT TO THE MATERIALS OR O THERWISE, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARR ANTIES INCLU DING, WITHOU T LIMITATION, THE WARRANTIES OF DESIGN, OF NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING, TRADE USAGE, TRADE PRACTICE, OR INDUSTRY STANDARDS.
VREF = FB VDDQ * Rbot/(Rtop + Rbot)
VREF = 0.50 * FBVDDQ
0.9V = 1.8V * 1.0K/1.0K + 1.0K)
DDR2:
DDR3:
A B D F H
1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
NTP_FBCDQS_RN<0> NTP_FBCDQS_RN<1> NTP_FBCDQS_RN<2> NTP_FBCDQS_RN<3> NTP_FBCDQS_RN<4> NTP_FBCDQS_RN<5> NTP_FBCDQS_RN<6> NTP_FBCDQS_RN<7>
FBCDQS0 FBCDQS1 FBCDQS2 FBCDQS3 FBCDQS4 FBCDQS5 FBCDQS6 FBCDQS7
FB_VREF2
FBCD0 FBCD1 FBCD2 FBCD3 FBCD4 FBCD5 FBCD6 FBCD7 FBCD8 FBCD9 FBCD10 FBCD11 FBCD12 FBCD13 FBCD14 FBCD15 FBCD16 FBCD17 FBCD18 FBCD19 FBCD20 FBCD21 FBCD22 FBCD23 FBCD24 FBCD25 FBCD26 FBCD27 FBCD28 FBCD29 FBCD30 FBCD31 FBCD32 FBCD33 FBCD34 FBCD35 FBCD36 FBCD37 FBCD38 FBCD39 FBCD40 FBCD41 FBCD42 FBCD43 FBCD44 FBCD45 FBCD46 FBCD47 FBCD48 FBCD49 FBCD50 FBCD51 FBCD52 FBCD53 FBCD54 FBCD55 FBCD56 FBCD57 FBCD58 FBCD59 FBCD60 FBCD61 FBCD62 FBCD63
FBCDQM0 FBCDQM1 FBCDQM2 FBCDQM3 FBCDQM4 FBCDQM5 FBCDQM6 FBCDQM7
2
U7C
BGA820 COMMON
3/14 FBC
B7
FBCD0
A7
FBCD1
C7
FBCD2
A2
FBCD3
B2
FBCD4
C4
FBCD5
A5
FBCD6
B5
FBCD7
F9
FBCD8
F10
FBCD9
D12
FBCD10
D9
FBCD11
E12
FBCD12
D11
FBCD13
E8
FBCD14
D8
FBCD15
E7
FBCD16
F7
FBCD17
D6
FBCD18
D5
FBCD19
D3
FBCD20
E4
FBCD21
C3
FBCD22
B4
FBCD23
C10
FBCD24
B10
FBCD25
C8
FBCD26
A10
FBCD27
C11
FBCD28
C12
FBCD29
A11
FBCD30
B11
FBCD31
B28
FBCD32
C27
FBCD33
C26
FBCD34
B26
FBCD35
C30
FBCD36
B31
FBCD37
C29
FBCD38
A31
FBCD39
D28
FBCD40
D27
FBCD41
F26
FBCD42
D24
FBCD43
E23
FBCD44
E26
FBCD45
E24
FBCD46
F23
FBCD47
B23
FBCD48
A23
FBCD49
C25
FBCD50
C23
FBCD51
A22
FBCD52
C22
FBCD53
C21
FBCD54
B22
FBCD55
E22
FBCD56
D22
FBCD57
D21
FBCD58
E21
FBCD59
E18
FBCD60
D19
FBCD61
D18
FBCD62
E19
FBCD63
A4
FBCDQM0
E11
FBCDQM1
F5
FBCDQM2
C9
FBCDQM3
C28
FBCDQM4
F24
FBCDQM5
C24
FBCDQM6
E20
FBCDQM7
C5
FBCDQS_WP0
E10
FBCDQS_WP1
E5
FBCDQS_WP2
B8
FBCDQS_WP3
A29
FBCDQS_WP4
D25
FBCDQS_WP5
B25
FBCDQS_WP6
F20
FBCDQS_WP7
C6
FBCDQS_RN0
E9
FBCDQS_RN1
E6
FBCDQS_RN2
A8
FBCDQS_RN3
B29
FBCDQS_RN4
E25
FBCDQS_RN5
A25
FBCDQS_RN6
F21
FBCDQS_RN7
A28
FB_VREF2
3
FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT
FBC_CMD0 FBC_CMD1 FBC_CMD2 FBC_CMD3 FBC_CMD4 FBC_CMD5 FBC_CMD6 FBC_CMD7 FBC_CMD8
FBC_CMD9 FBC_CMD10 FBC_CMD11 FBC_CMD12 FBC_CMD13 FBC_CMD14 FBC_CMD15 FBC_CMD16 FBC_CMD17 FBC_CMD18 FBC_CMD19 FBC_CMD20 FBC_CMD21 FBC_CMD22 FBC_CMD23 FBC_CMD24 FBC_CMD25 FBC_CMD26
FBC_CLK0
FBC_CLK0
FBC_CLK1
FBC_CLK1
FBC_DEBUG
FBC_REFCLK FBC_REFCLK
FBC_PLLVDD
FBC_PLLAVDD
FBC_PLLGND
FBCAL_PD_VDDQ
FBCAL_PU_GND
FBCAL_TERM_GND
4
FBCCLK0 FBCCLK0* FBCCLK1 FBCCLK1*
GND
FBCA3 FBCA0 FBCA2 FBCA1 FBDA3 FBDA4 FBDA5 NTP_FBCCS1* FBCCS0* FBCWE* FBCBA0
NTP_G3C_CMD12 FBDA2 FBCA12 FBCRAS* FBCA11 FBCA10 FBCBA1 FBCA8 FBCA9 FBCA6 FBCA5 FBCA7 FBCA4 FBCCAS* NTP_G3C_CMD26
NTP_FBC_DBI0 NTP_FBC_DBI1
FBCAL_PD
FBCAL_PU
FBCAL_TERM
FBCCKE
TP_FBC_DEBUG
TP_FBC_REFCLK TP_FBC_REFCLK*
FBC_PLLVDD
FBC_PLLAVDD
FBVDDQ
FBDA[5..2]
FBCA[12..0]
3 0
FBCBA[1..0]
2 1
3 4 5
0
2
12
11 10
1 8 9 6 5 7 4
7<
OUT
7<
OUT
8<
OUT
8<
OUT
FBVDDQ
R526
49.9
1% 0402 COMMON
R525
R523
49.9
0
1%
5%
0402
0402
COMMON
COMMON
OUT
OUT
OUT
OUT OUT
OUT
OUT
Place close to balls
8<
7< 8<
7< 8<
7< 8< 7< 8<
7< 8<
7< 8<
C646 .01UF
16V 10% X7R 0402 COMMON
C629 .01UF
16V 10% X7R 0402 COMMON
COMMON
Place near GPU
AA23 AB23 H16 H17 J10 J23 J24 J9 K11 K12 K21 K22 K24 K9 L23 M23 T25 U25
C13 A16 A13 B17 B20 A19 B19 B14 E16 A14 C15 B16 F17 C19 D15 C17 A17 C16 D14 F16 C14 C18 E14 B13 E15 F15 A20
E13 F13 F18 E17
C20
RFU
D1
RFU
F12
B1 C1
G8
G10
G9
K26
H26
J26
5
7< 8<
OUT
FBCCKE
R527
10K
5%
0402
6
7
NET DIFFPAIR NET_SPACING_RULE
FBCCLK0
FBCCLK0*
FBCCLK1
FBCCLK1*
FBC_PLLVDD
FBC_PLLAVDD
FBC_VREF2
FBCRAS*
FBCCAS*
FBCWE*
FBCCKE
FBCCS0*
FBCD[63..0]
FBCDQS[7..0]
FBCDQM[7..0]
FBCA[12..0]
FBCBA[1..0]
FBDA[5..2]
FBCAL_PD
FBCAL_PU
FBCAL_TERM
FBCCLK0 20MIL_G2G_30MIL
FBCCLK0 20MIL_G2G_30MIL
FBCCLK1 20MIL_G2G_30MIL
FBCCLK1 20MIL_G2G_30MIL
12 10MIL
12 10MIL
12 10MIL
8
HGFEDCBA
1
10MIL
10MIL
10MIL
10MIL
10MIL
10MIL
15MIL
10MIL
10MIL
10MIL
10MIL
10MIL
10MIL
10MIL
2
3
GND
FBVDDQ
C518
C524
C675
C641 .01UF
16V 10% X7R 0402 COMMON
C661 .01UF
16V 10% X7R 0402 COMMON
4
C639 .1UF
10V 10% X5R 0402 COMMON
C623 .1UF
10V 10% X5R 0402 COMMON
LB509
LB507
BEAD_0603 CO MMON
150-220R@100MHz
COMMONBEAD_0603
150-220R@100MHz
NVVDD
.01UF
.01UF
16V 10% X7R 0402
A3V3
COMMON
16V 10% X7R 0402 COMMON
.01UF
16V 10% X7R 0402 COMMON
GND
GND
GND
5
GND GND
星期四, 十月 28, 2004
GIGABYTE
FB BANK C
GV-NX66256DP
1.0
416
8
ASSEMBLY PAGE DETAIL
2
3
4
BASE LEVEL GENERIC SCHEMATIC ONLY, COMMON & NO_STUFF ASSEMBLY NOTES AND BOM NOT FINAL FB BANK C, FBVTT
E GC
5
6
Title
Size Document Number Rev
Custom
Date: Sheet of
7
1
2
3
4
5
6
7
8
HGFEDCBA
MEMORY 1st bank 0..31
PLACE ALL DISCRETE COMPONENTS AS NEAR AS POSSIBLE TO MEMORY
1
A A
2
B B
3
C C
4
D D
5
ALL NVIDIA DESIGN SPECIFICATIONS, REFERENCE SPECIFICATIONS, REFERENCE BOARDS, FILES, DRAWINGS, DIAGNOSTICS, LISTS AND OTHER DOCUMENTS OR INFORMATION (TOGETHER AND SEPARATELY, 'MATERIALS') ARE BEING PROVIDED 'AS IS'. THE MATERIALS MAY CONTAIN KNOWN AND UNKNOWN VIOLATIONS OR DEVIATIONS OF INDUSTRY STANDARDS AND SPECIFICATIONS. NVIDIA MAKES NO WARRANTIES, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE WITH RESPECT TO THE MATERIALS OR O THERWISE, AND EXPRESSLY DISCLAIMS ALL IMPLIED WARR ANTIES INCLU DING, WITHOU T LIMITATION, THE WARRANTIES OF DESIGN, OF NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING, TRADE USAGE, TRADE PRACTICE, OR INDUSTRY STANDARDS.
A B D F H
1
3<> 6<
FBAA[12..0]
3> 6<
IN
FBARAS* FBARAS*
3> 5< 6<
IN
FBACAS* FBACAS*
3> 5< 6<
IN
FBAWE* FBAWE*
3> 5< 6<
IN
FBACS0* FBACS0*
3> 5< 6<
IN
FBAA0 FBAA0
0
FBAA1 FBAA1
1
FBAA2 FBAA2
2
FBAA3 FBAA3
3
FBAA4 FBAA4
4
FBAA5 FBAA5
5
FBAA6 FBAA6
6
FBAA7 FBAA7
7
FBAA8 FBAA8
8
FBAA9 FBAA9
9
FBAA10 FBAA10
10
FBAA11 FBAA11
11
FBAA12 FBAA12
12 0
3> 5< 6<
IN
FBAD[63..0]
3<> 6<>
BI
FBADQM[7..0]
3> 6<
IN
FBADQS[7..0]
IN
0
FBADQM0 FBADQM0
FBADQM1
1
FBADQM2
2
3
FBADQM3
0
FBADQS0
FBADQS1
1
2
FBADQS2
FBADQS3
3
FBABA0 FBABA0FBABA[1..0] FBABA[1..0] FBABA1 FBABA1
1
FBACKE FBACKE
3> 5< 6<
IN
FBACLK0
3> 5<
IN
FBACLK0*
3> 5<
IN
U12A
16M66 16M66 COMMON
23
RAS
22
CAS
21
WE
24
CS
29
A<0>
30
A<1>
31
A<2>
32
A<3>
35
A<4>
36
A<5>
37
A<6>
38
A<7>
39
A<8>
40
A<9>
28
AP/A<10>
41
A<11>
42
A<12>
26
BA<0>
27
BA<1>
44
CKE
45
CLK
46
CLK
NC
NC
NC
NC
1415171819
25
NTP_MEM2_NC1
NTP_MEM2_NC2
NTP_MEM2_NC3
NTP_MEM2_NC4
NTP_MEM2_NC5
0
FBAD0
1
FBAD1
2
FBAD2
3
FBAD3
4
FBAD4
5
FBAD5
6
FBAD6
7
FBAD7
FBADQS0
8
FBAD8
9
FBAD9
10
FBAD10
11
FBAD11
12
FBAD12
13
FBAD13
14
FBAD14
15
FBAD15
FBADQM1 FBADQS1
FBVDDQ
1
VDD VDD
33
VDD
3
VDDQ
9
VDDQ VDDQ
55
VDDQ
61
VDDQ
34
VSS VSS VSS
VSSQ VSSQ VSSQ VSSQ VSSQ
Vref
NC
NC
NC
43
505253
NTP_MEM2_NC6
NTP_MEM2_NC7
FBVDDQ
48 66
6 12
GND
58 64
49
U11B
16M66 COMMON
8 7 5 4
2 10 11 13
20 16
U12B
16M66 COMMON
2
4
7
5
8 11 13 10
20 16
R60 1K
1% 0402 COMMON
VREF_B VREF_B
C194 .047UF
16V 10% X7R 0402 COMMON
GND
GND
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS
3> 5<
IN
R62 1K
1% 0402 COMMON
FBACLK0
3> 5< 6<
IN
5> 6>
OUT
FBVDDQ
R504 120/X
5% 0402 DNP
R503 120/X
5% 0402 DNP
R5055%100
3> 5< 6<
IN
3> 5< 6<
IN
3> 5< 6<
IN
3> 5< 6<
IN
0 1 2 3 4 5 6 7 8 9 10 11 12 0 1
3> 5< 6<
IN
FBACLK0
3> 5<
IN
FBACLK0*
3> 5<
IN
16
FBAD16
17
FBAD17
18
FBAD18
19
FBAD19
20
FBAD20
21
FBAD21
22
FBAD22
23
FBAD23
FBADQM2 FBADQS2
24
FBAD24
25
FBAD25
26
FBAD26
27
FBAD27
28
FBAD28
29
FBAD29
30
FBAD30
31
FBAD31
FBADQM3 FBADQS3
R507 120/X
5% 0402 DNP
FBACLK0*
COMMON0603
R506 120/X
5% 0402 DNP
U11A
16M66 16M66 COMMON
23
RAS
22
CAS
21
WE
24
CS
29
A<0>
30
A<1>
31
A<2>
32
A<3>
35
A<4>
36
A<5>
37
A<6>
38
A<7>
39
A<8>
40
A<9>
28
AP/A<10>
41
A<11>
42
A<12>
26
BA<0>
27
BA<1>
44
CKE
45
CLK
46
CLK
NC
NC
NC
NC
NC
1415171819
NC
25
43
505253
FBVDDQ
1
VDD VDD
33
VDD
3
VDDQ
9
VDDQ VDDQ
55
VDDQ
61
VDDQ
34
VSS
48
VSS
66
VSS
6
VSSQ
12
VSSQ VSSQ VSSQ VSSQ
Vref
NC
GND
58 64
C189 .047UF
16V 10% X7R 0402 COMMON
5> 6>
OUT
49
GND
NTP_MEM2_NC10
NTP_MEM2_NC11
NTP_MEM2_NC12
NTP_MEM2_NC13
NTP_MEM2_NC8
NTP_MEM2_NC9
U12C
16M66 COMMON
59
DQ<0>
54
DQ<1>
56
DQ<2>
60
DQ<3>
57
DQ<4>
62
DQ<5>
65
DQ<6>
63
DQ<7>
47
DQM
51
DQS
U11C
16M66 COMMON
56
DQ<0>
54
DQ<1>
65
DQ<2>
57
DQ<3>
62
DQ<4>
60
DQ<5>
59
DQ<6>
63
DQ<7>
47
DQM
51
DQS
3> 5<
IN
NTP_MEM2_NC14
GND GND
ASSEMBLY PAGE DETAIL
2
3
4
BASE LEVEL GENERIC SCHEMATIC ONLY, COMMON & NO_STUFF ASSEMBLY NOTES AND BOM NOT FINAL MEMORY 1ST BANK 0. .31
E GC
5
6
FBVDDQ
C141 .022UF
16V 10% X7R 0402 COMMON
GND
FBVDDQ
C151 220PF
50V 5% COG 0402 COMMON
GND
FBVDDQ
C175 .047UF
16V 10% X7R 0402 COMMON
GND
FBVDDQ
C144 .022UF
16V 10% X7R 0402 COMMON
GND
FBVDDQ
C178 220PF
50V 5% COG 0402 COMMON
GND
FBVDDQ
C160 .047UF
16V 10% X7R 0402 COMMON
GND
Place plane decoupling caps near DQS-DQM pairs.
FBVDDQ
FBVDDQ
C508 .01UF
16V 10% X7R 0402 COMMON
GND
FBVDDQ
FBVDDQ
C505 .01UF
16V 10% X7R 0402 COMMON
GND
C145 4700PF
25V 10% X7R 0402 COMMON
C184 220PF
50V 5% COG 0402 COMMON
C193 4700PF
25V 10% X7R 0402 COMMON
C149 4700PF
25V 10% X7R 0402 COMMON
C165 220PF
50V 5% COG 0402 COMMON
C183 4700PF
25V 10% X7R 0402 COMMON
GND
GND
C202
C201 .022UF
16V 10% X7R 0402 COMMON
C200 220PF
50V 5% COG 0402 COMMON
C188 4700PF
25V 10% X7R 0402 COMMON
C199 .022UF
16V 10% X7R 0402 COMMON
C187 220PF
50V 5% COG 0402 COMMON
C174 4700PF
25V 10% X7R 0402 COMMON
FBVDDQ
FBVDDQ
C506
C501
.01UF
.01UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
GND
GND
FBVDDQ
FBVDDQ
C503
C510
.01UF
.01UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
GND
GND
Title
Size Document Number Rev
Custom
星期四, 十月 28, 2004
Date: Sheet of
C210
4700PF
.022UF
25V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
C166
C179
220PF
220PF
50V
50V
5%
5%
COG
COG
0402
0402
COMMON
COMMON
C155
C162
4700PF
.047UF
25V
16V
10%
10% X7R
X7R
0402
0402
COMMON
COMMON
C192
C209
4700PF
.022UF
25V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
C169
C154
220PF
220PF
50V
50V
5%
5%
COG
COG 0402
0402
COMMON
COMMON
C161
C173
4700PF
.047UF
25V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
FBVDDQ
C502
C511
.01UF
.01UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
GND
FBVDDQ
C516
C512 .01UF
.01UF
16V
16V
10%
10%
X7R
X7R 0402
0402 COMMON
COMMON
GND
GIGABYTE
MEMORY 1st bank 0..31
GV-NX66256DP
7
C214 4700PF
25V 10% X7R 0402 COMMON
C138
4.7UF
6.3V 20% X5R 0603 COMMON
C213 4700PF
25V 10% X7R 0402 COMMON
C146
4.7UF
6.3V 20% X5R 0603 COMMON
516
8
C137
4.7UF
6.3V 20% X5R 0603 COMMON
C206
4.7UF
6.3V 20% X5R 0603 COMMON
1
2
3
4
5
1.0
Loading...