Gigabyte GS-R114L User Manual

GS-R114L

1U Rack Mount Server

System Installation Guide

Intel® Pentium Prescot LGA775 Processor Serverboard

Rev. 1.1

25A080-01140-F00

GS-R114L Rack Mount Server

 

Table of Content

 

Safety, Care and Regulatory Information ................................................

4

Introduction ..............................................................................................

8

Contents Packages ................................................................................

8

WARNING! ...............................................................................................

8

Chapter 1 Features Summary .................................................................

9

Chapter 2 System Overview .................................................................

11

Chapter 3 System Hardware Installation ...............................................

12

Step 3-1: Chassis Removal and Installation ................................................................

12

Step 3-2: CPU Installation ...............................................................................................

13

Step 3-3: Heat Sink Installation .......................................................................................

14

Step 3-4: Memory Installation ........................................................................................

14

Step 3-5: PCI Expansion Card Installation ....................................................................

15

Step 3-6: Hard Disk Drive Installation ............................................................................

16

Step 3-7: FAN Duct Removal and Installation ..............................................................

17

Chapter 4 Appearance of GS-R114L ...................................................

18

4-1: Front View of GS-R114L .........................................................................................

18

4-2: Rear View of GS-R114L .........................................................................................

19

4-3: Switch and LED Indicators Introduction .................................................................

20

4-4: LAN LED Description ...............................................................................................

21

4-5 : Connector Icon Description ...................................................................................

22

Chapter 5 Motherboard Layout & Jumper Setting ................................

23

5-1: GA-4MPSV Motherboard Layout ............................................................................

23

5-2: Jumper Setting .........................................................................................................

24

Chapter 6 BIOS Setup ..........................................................................

26

Main ...........................................................................................................

28

Advanced Processor Options ........................................................................................

31

2

 

 

Table of Content

Advanced ...................................................................................................

 

33

Memory Configuration .....................................................................................................

34

PCI Configuration .............................................................................................................

35

I/O Device Configuration .................................................................................................

37

Advanced Chipset Control .............................................................................................

42

Hardware Monitor ............................................................................................................

44

Security ......................................................................................................

 

46

Server .........................................................................................................

 

48

System Management ......................................................................................................

49

Console Redirection ........................................................................................................

50

Boot ............................................................................................................

 

53

Exit .............................................................................................................

 

54

Chapter 6 Driver Installation ..................................................................

58

A.Intel Chipset Software Installation Utilities ..................................................................

58

B.Intel

LAN Driver Installation ........................................................................................

60

C.Intel

Host RAID Driver Installation .............................................................................

62

D.VGA ES100 Driver Installation ....................................................................................

64

E.DirectX 9.0 Driver Installation ......................................................................................

65

Chapter 7 Appendix ..............................................................................

66

7-1: Acronyms .................................................................................................................

66

3

GS-R114L Rack Mount Server

Safety, Care and Regulatory Information

Important safety information

Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use.

*The product should be operated only from the type of power source indicated on the rating label.

*If your computer has a voltage selector switch, make sure that the switch is in the proper position for your area. The voltage selector switch is set at the factory to the correct voltage.

*The plug-socket combination must be accessible at all times because it serves as the main disconnecting device.

*All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power outlet. This is a safety feature. The equipment grounding should be in accordance with local and national electrical codes. The equipment operates safely when it is used in accordance with its marked electrical ratings and product usage instructions

*Do not use this product near water or a heat source.

*Set up the product on a stable work surface or so as to ensure stability of the system.

*Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you provide adequate space around the system for ventilation when you set up your work area. Never insert objects of any kind into the ventilation openings.

*To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets before removing covers.

*Allow the product to cool before removing covers or touching internal components.

Precaution for Product with Laser Devices

Observe the following precautions for laser devices:

*Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than those specified in the product's documentation.

*Only authorized service technicians should repair laser devices.

Precaution for Product with Modems, Telecommunications, ot Local Area Network Options

Observe the following guidelines when working with options:

* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical shock from lightning.

4

Safety Information

*To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.

*Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.

*Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.

*Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.

Federal Communications Commission (FCC) Statement

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Neither the provider nor the manufacturer are responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operatetheequipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1)this device may not cause harmful interference, and

(2)this device must accept any interference received, including interference that may cause undesired operation.

FCC part 68 (applicable to products fitted with USA modems)

The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment. You must, upon request, provide this information to your telephone company.

If your telephone equipment causes harm to the telephone network, the Telephone Company may discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC.

5

GS-R114L Rack Mount Server

Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.

The FCC prohibits this equipment to be connected to party lines or coin-telephone service.

The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part 68, Sec. 68.381 (c) (3)).

/ for Canadian users only /

Canadian Department of Communications Compliance Statement

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of Industry Canada.

Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte par Industrie Canada.

DOC notice (for products fitted with an Industry Canada-compliant modem)

The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user satisfaction.

Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the local Telecommunications Company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions might not prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier.Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if resent are connected together. This precaution may be particularly important in rural areas.

Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

6

Safety Information

NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.

/ for European users only /

CAUTION

Danger of explosion if battery is incorrectly replaced.

Replace only with the same or equivalent type recommended by the manufacturer.

Dispose of used batteries according to the manufacturer’sinstructions.

7

GS-R114L Rack Mount Server

Introduction

Welcome to Gigabyte GS-R114L Rack mount Server System Installation Guide. The guide provides instructions for configuration hardware for the GS-R114L your system.

This installation guide will assist you in installing all the essential components for the sever system. For your protection, please read and undertand all of the safety and operating instructions regarding your Gigabyte Server and retain for future reference. The procedures in this guidebook assume that your are a system or network administrator experienced in installing similar hardware.

Contents Packages

When opening the package, please ensure the system components are not damaged during the shipping. Using the following checklist to verify the contents. If any component is missing or damaged in the

system, please contact your vendor immediately.

 

; Chassis

;

GA-4MPSV Motherboard (Installed)

; Power Supply (Installed)

;

GSMT User’s Manual

; FAN Duct x 1

;

CPU Heat Sink x 1

; Standard Floppy Drive (Installed)

;

Silm type CD-ROM drive (Installed)

; Cables (RJ45)

;

GS-R114L System Installation Guide

; Case Handle Kit x 2

;

Driver CD for motherboard driver & utility

WARNING!

Computer motherboards and expansion cards contain very delicate Integrated Circuit (IC) chips. To protect them against damage from static electricity, you should follow some precautions whenever you work on your computer.

1.Unplug your computer when working on the inside.

2.Use a grounded wrist strap before handling computer components. If you do not have one, touch both of your hands to a safely grounded object or to a metal object, such as the power supply case.

3.Hold components by the edges and try not touch the IC chips, leads or connectors, or othercomponents.

4.Place components on a grounded antistatic pad or on the bag that came with the components whenever the components are separated from the system.

5.Ensure that the ATX power supply is switched off before you plug in or remove the ATX power connector on the motherboard.

8

 

 

Feature Summary

 

Chapter 1 Features Summary

 

 

 

 

Motherboard

GA-4MPSV

 

Processor Supported

Supports Intel® Pentium Prescot and Smithfield processor

 

 

Intel® Prescott LGA 775 supports 800/1066MHz FSB

 

 

L2 cache on-die per processor from 1M

 

 

 

 

Chipset

Intel® Mukilteo Chipset

 

 

Intel® ICH7R

 

 

Intel® 6702PXH-V

 

System Memory:

 

 

Memory Capacity

4 x DDRII socket up to 8 GB

 

Memory Type

Un-buffered DDRII 533/667

 

DIMM Size

Support 256MB, 512MB, and 1GB memory

 

Error Correction:

Single-bit Errors Correction, Multiple Bit Errors Detection

 

 

 

 

Expansion Slot

1 Riser card supports 1 x 64/133 MHz & 1 PCI-E x8 add-on cards

 

 

(3.3V)

 

 

1 x Low Profile PCI-X add-on card (Half-High/Half-Length)

 

 

1 x Full-Size add-on card (Full-High/Half-Length)

 

 

 

 

SATA RAID controller

ICH7R

 

 

Supports SATA RAID 0,1,5 without Linux support

 

 

 

 

Cooling Fans:

8 X System Fan

 

 

1 X Power Fan

 

 

 

 

Integrated LANs:

 

 

Controller

Dual Intel 82573V® Gigabit Ethernet controllers

 

 

 

 

Integrated Graphics:

 

 

Controller

ATI RN50 ES1000

 

Graphics Memory

16Mb DDR SDRAM

 

 

 

 

Mass Storage System

2 x Internal SATA HDD

 

 

1 x Silm Type FDD

 

 

1 Slim Type CD-ROM

 

 

Optional DVD Combo

 

 

 

9

GS-R114L Rack Mount Server

Super I/O

 

 

Controller

ITE IT8712FIX-A Super I/O

 

 

 

Built-in I/O

1 x Serial port (COM)

 

2 x USB 2.0 dual-port connector (1 at front panel)

 

1 x VGA connector

 

2 x RJ45 LAN ports

 

P/S 2 Keyboard and Mouse Connectors

 

1 x RJ45 on front for console redirection

 

 

 

System BIOS:

 

 

BIOS Type

Phoenix® BIOS, Multi-boot BBS 1.0 Compliant 8Mb Flash

 

Memory

Special Features

BIOS HW Monitoring reporting (The values monitored by HW

 

Monitoring chipset)

 

Console Redirection via COM ports

 

Intel® Hyper Threading Support

 

Resume after AC Back

 

Wake On LAN

 

ACPI 1.0B Compliant/ ACPI defined S1, S4, and S5

 

Software Mini BMC supported

 

 

Server Management Functions: (Optional)

BMC Chip

NS IPMI 1.5 controller

Failure Detection

IPMI 1.5 specification of Server management

Event Logging

32KB Nonvolatile Memory to Log System Failure Events

Remote Management

Follow the IPMI 1.5 specification of Server management

 

 

 

Environment

 

 

AmbientTemperature

Operating Temperature: 5oC to 35oC

 

Non-operating Temperature: 0oC to 50oC

Relative Humidity

10-80% operating Humidity at 30o C

Safety Regulations

FCC, CE, BSMI, CB, Win2000, 2003 WHQLIPMI 1.5 ( Option)

 

System Dimention:

427.5mm x 521mm x 42.6 mm

 

Electrical Power Supply

Single Power Supply 250W

 

1 0

System Overview

Chapter 2 System Overview

A

D

 

 

E

B

C

 

F

G

F

 

H

A. Chassis Cover

E. Fan Wall

B. Motehrboard - GA-4MPSV

F. Hard Disk Drive Plate

C. System Fans

G. Floppy Drive

D. Riser Card Support

H. Front LED

 

 

1 1

GS-R114L Rack Mount Server

Chapter 3 System Hardware Installation

Please observe the safety information in chapter “Important Safety Information”

Do not expose the server to extreme environmental conditions. Protect it from dust, humidity, and heat.

Step 3-1: Chassis Removal and Installation

Step 1

Loosen the thumbscrew from the back of the server.

Step 2

Push down the indentation located at two sides of the chassis, and slide toward to remove the

 

top cover.

 

 

Step 3

Reverse Step 1, and 2 to replace the chassis cover.

 

 

 

 

Step 1

 

Step 2

 

 

 

 

 

 

Thumbscres

Note: Before installing CPU, you must remove the FAN duct. For FAN duct removal, please see Sub-section 3-7 “FAN Duct Removal and Installtion” for detail instruction.

1 2

Gigabyte GS-R114L User Manual

Hardware Installation Process

Step 3-2: CPU Installation

Please make sure the CPU type and speed that are supported by the motherboard.

Step 1 Gently lift the metal lever located on the CPU socket to the upper-right position. Step 2 Remove the plastic covering on the CPU socket.

Step 3 Align the indented corner of the CPU with the triangle and gently insert the CPU into position. (Grasping the CPU firmly between your thumb and forefinger, carefully place it into the socket in a straight and downwards motion. Avoid twisting or bending motions that might cause damage to the CPU during installation.)

Step 4 Once the CPU is properly inserted, please replace the plastic covering and push the metal lever back into its original position.

Step 5 Close the lever, reverse step 1 & 2.

Step 1

 

Step 2

 

 

 

Step 3

 

Step 4

 

 

 

1 3

GS-R114L Rack Mount Server

Step 3-3: Heat Sink Installation

Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU.

Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.

Step 3-4: Memory Installation

1.Unlock a DIMM socket by pressing the retaining clips outwards.

2.Aling a DIMM on the socket such that the notch on the DIMM exactly match the notches in the socket.

3.Firmly insert the DIMMinto the socket until the retaining clips snap back in place.

4.When installing the DIMM into the DIMM socket, we recommend to populate one DIMM in Channel A module and one in Channel B module for best performance.

Please note that each logical DIMM must be made of two identical DIMMs having the same device size on each and the same DIMM size.

5.Reverse the installation steps when you wish to remove the DIMM module.

Step 1

 

Step 2

 

 

 

Retaining Clip

1 4

Hardware Installation Process

Step 3-5: PCI Expansion Card Installation

GS-R114L provides expansion riser slots for one PCI-X full-height/full-length 64/66~100MHz; and one with PCI-E x8 slot. To install the peripheral, please go through the following steps.

Note!! Before installing the PCI expansion card, please check the card size limitation. Size limitation for PCI-X full-height/full-length is 228.5 mm x 91.5 mm; size limitation for Low-Profile Card : 167.5 mm x 56 mm .

Step 1 Lift the riser bracket slightly, then pull it out from the server chassis. Step 2 Lossen the screw on the riser bracket.

Step 2 Align the expansion card with the guiding groove. Slide the expansion card into the slot until the card firmly seats.

Step 3 Align the riser bracket to the system module (see the arrow direction mark 1), and push it to locked position.

Step 4 Reverse Step 1 & 2 to lock the riser bracket firmly. Installation completed.

Step 1

 

Step 2

 

 

 

Step 3

 

 

Step 4

 

 

 

 

 

 

1 5

GS-R114L Rack Mount Server

Step 3-6: Hard Disk Drive Installation

Step 1 Lossen the screws securing the hard drive plate.

Step 2 Slide toward to remove the hard drive plate from system.

Step 3 Place hard disk on the plate and lock hard drive with 4 screws.

Step 4 Replace the hard drive plate, slide the blank into the bay until it locks into place.Connect HDD power cable.

Step 5 Reverse step 1, 2, 3 and 4 to complete the HDD installtion.

 

 

Step 2

Step 1

 

 

 

 

Remove

Step 3

 

Step 4

 

 

 

1 6

Hardware Installation Process

Step 3-7: FAN Duct Removal and Installation

Step 1 Pull up the screw-holder and lossen the thumbscrews. Lift up to remove the fan duct.

Step 2 For FAN Duct Installation, place the fan duct on the top of heat sinks. Fasten the screws to the locked position and push down the screw-holders.

Step 1 Step 2

1 7

GS-R114L Rack Mount Server

Chapter 4 Appearance of GS-R114L

4-1: Front View of GS-R114L

Slim Type CD-ROM

Slim Floopy

USB Connector

LEDs

RJ45 (For Console Redirection)

1 8

System Appearance

4-2: Rear View of GS-R114L

Power

VGA Port

COM Port

Low Profile Riser Slot

Full-size/Full-length Riser Slot

Keyboard Connector

Mouse Connector

USB Connectors

LAN 1 & 2 Ports

1 9

GS-R114L Rack Mount Server

4-3: Switch and LED Indicators Introduction

Status HDD Fail Warning

HDD

Power/Sleep

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAN1/2 Activities

 

 

 

 

 

 

 

NMI

 

 

 

 

 

 

ID

 

 

 

 

Name

 

Color

 

Condition

 

 

Description

Power

 

Green

 

On

 

 

Power On

 

 

Green

 

Blink

 

 

Sleep (S1)

 

 

--

 

Off

 

 

Power Off (S4/S5)

Status

 

Green

 

On

 

 

System Ready On/ Alarm

 

 

Amber

 

Blink

 

 

System Ready but deqraded, CPU Failed,

 

 

 

 

 

 

 

 

 

DIMM Killed.

 

 

 

 

 

 

 

 

 

 

Amber

 

On

 

 

Critical Alarm: Critical Power Module Failure,

 

 

 

 

 

 

 

 

 

Critical FANs Failure, Voltage (Power Supply)

 

 

 

 

 

 

 

 

 

Critical Temperature and Voltage

 

 

 

 

 

 

 

 

 

--

 

Off

 

 

System Not Ready/ Post error/NMI event/CPU

 

 

 

 

 

 

 

 

 

or terminator missing

 

 

 

 

 

 

 

 

HDD

 

Green

 

Blink

 

 

Hard Disk Drive Access

 

 

Amber

 

On

 

 

HDD Fault

 

 

--

 

Off

 

 

No Access and No HDD Fault

LAN1

 

Green

 

On

 

 

LAN Link / No access

Activity

 

Green

 

Blink

 

 

LAN access

 

 

--

 

Off

 

 

Idle

LAN2

 

Green

 

On

 

 

LAN Link / No access

Activity

 

Green

 

Blink

 

 

LAN access

 

 

--

 

Off

 

 

Idle

Identification

 

Blue

 

Blink

 

 

Unit selected for identification

 

--

 

Off

 

 

No identification

 

 

 

 

 

 

 

 

 

 

 

2 0

LED Description

4-4: LAN LED Description

Name

Color

Condition

Description

LAN

Green

ON

LAN Link / no Access

Link/Activity

 

 

 

Green

BLINK

LAN Access

 

-

OFF

Idle

GbE LAN

Yellow

ON

1Gbps connection

Speed

 

 

 

Yellow

BLINK

Port identification with 1Gbps connection

 

Green

ON

100Mbps connection

 

Green

BLINK

Port identification with 10 or 100Mbps connection

 

-

OFF

10Mbps connection

 

 

 

 

2 1