Gigabyte GA-7IXE User Manual [zh]

Page 1
FCC Compliance Statement:
Per FCC Part 2 Section 2. 1077(a)
This equipment has been tested and found to comply with limits for a Class B digital device ,
Responsible Party Name: G.B.T. INC.
Address: 18305 Valley Blvd., Suite#A
LA Puent, CA 91744
Phone/Fax No: (818) 854-9338/ (818) 854-9339
hereby declares that the product
Product Name:
Mother Board
Model Number:
Conforms to the following specifications:
FCC Part 15, Subpart B, Section 15.107(a) and Section 15.109(a), Class B Digital Device
Supplementary Information:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful and (2) this device must accept any inference received, including that may cause undesired operation.
Representative Person's Name: ERIC LU
GA-7IXE
Signature:
Date: Jan. 12, 2000
Eric Lu
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television equipment
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna
-Move the equipment away from the receiver
-Plug the equipment into an outlet on a circuit different from that to which the receiver is connected
-Consult the dealer or an experienced radio/television technician for additional suggestions
You are cautioned that any change or modifications to the equipment not expressly approve by the party responsible for compliance could void Your authority to operate such equipment.
This device complies with Part 15 of the FCC Rules. Operation is subjected to the following two conditions 1) this device may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation.
Page 2
Declaration of Conformity
We, Manufacturer/Importer
(full address)
G.B.T. Technology Träding GMbH
Ausschlager Weg 41, 1F, 20537 Hamburg, Germany
( description of the apparatus, system, installation to which it refers)
(reference to the specification under which conformity is declared)
in accordance with 89/336 EEC-EMC Directive
EN 55011 Limits and methods of measurement EN 61000-3-2* Disturbances in supply systems caused
of radio disturbance characteristics of EN60555-2 by household appliances and similar
industrial, scientific and medical (ISM electrical equipment “Harmonics” high frequency equipment
EN55013 Limits and methods of measurement EN61000-3-3* Disturbances in supply systems caused of radio disturbance characteristics of EN60555-3 by household appliances and similar broadcast receivers and associated electrical equipment “Voltage fluctuations” equipment
EN 55014 Limits and methods of measurement EN 50081-1 Generic emission standard Part 1: of radio disturbance characteristics of Residual, commercial and light industry household electrical appliances, portable tools and similar electrical EN 50082-1 Generic immunity standard Part 1: apparatus Residual, commercial and light industry
EN 55015 Limits and methods of measurement EN 55081-2 Generic emission standard Part 2: of radio disturbance characteristics of Industrial environment fluorescent lamps and luminaries
EN 55020 Immunity from radio interference of EN 55082-2 Generic immunity standard Part 2: broadcast receivers and associated Industrial environment equipment
EN 55022 Limits and methods of measurement ENV 55104 Immunity requirements for household of radio disturbance characteristics of appliances tools and similar apparatus information technology equipment
DIN VDE 0855 Cabled distribution systems; Equipment EN 50091- 2 EMC requirements for uninterruptible
part 10 for receiving and/or distribution from power systems (UPS)
part 12 sound and television signals
declare that the product
Mother Board
GA-7IXE
is in conformity with
CE marking (EC conformity marking)
The manufacturer also declares the conformity of above mentioned product
with the actual required safety standards in accordance with LVD 73/23 EEC
EN 60065 Safety requirements for mains operated EN 60950 Safety for information technology equipment
electronic and related apparatus for including electrical business equipment household and similar general use
EN 60335 Safety of household and similar EN 50091-1 General and Safety requirements for electrical appliances uninterruptible power systems (UPS)
Signature
Date : Jan. 12, 2000 Name : Rex Lin
(Stamp)
Manufacturer/Importer
:
Rex Lin
Page 3
7IXE
AMD
TM
Athlon AGP 主機板
中文安裝手冊
AMDTM Athlon 處理器 主機板
R-11-01-000216C
Page 4
REV. 1.1 First Edition
使用手冊之組織架構
此安裝手冊是依下列章節組織而成:
1) 版本修改摘要 使用手冊版本修改資訊
2) 清點附件 產品盒內附件清單
3) 特色摘要 主機板詳細資訊和規格
4) 硬體設定 主機板安裝指南
5) 效能測試和晶片組功能方塊圖 主機板效能測試結果和晶片組功 能方塊圖
6) BIOS 功能設定 BIOS功能設定指南
7) 附錄 參考資料
Page 5
目 錄
版本修改摘要 P.1
清點附件 P.2
特色彙總 P.3
7IXE 主機板的元件配置圖 P.5
CPU 速度設定/插座及接腳設定的快速安裝指南 P.6
效能測試 P.18
晶片組功能方塊圖 P.19
記憶體安裝指南 P.20
BIOS 功能設定目錄 P.21
附錄 P.51
Page 6
Page 7
7IXE主機板
版本修改摘要
版本 修改摘要 日期
1.1 7IXE 主機板中文安裝手冊首版發行 Feb.200
0
本手冊所有提及之商標與名稱皆屬該公司所有。
本手冊若有任何內容修改,恕不另行通知。
1
Page 8
2000216日 台北,台灣
6ZM7/6ZM7A Motherboard
Page 9
Page 10
清點附件
þ 7IXE 主機板一片 þ 軟、硬碟埠排線各一條 þ主機板驅動程式光碟片(TUCD) o內接式 COM B 接頭排線 o內接式 USB 接頭排線 o SCSI 裝置排線 þ7IXE 中文使用手冊
清點附件
2
Page 11
7IXE主機板
特色彙總
規格 Ÿ 主機板採四層設計 ATX 規格( 30.5 公分 x 20.5 公分)
CPU
晶片組 AMD 750 ,包含:
時脈產生器 Ÿ 支援 90 / 95 / 100 / 105 / 110 / 115MHz 記憶體 Ÿ 3 168-pin DIMM 插槽
I/O 控制器 Ÿ Winbond 83977 擴充槽 Ÿ 1 個AGP (Accelerated Graphics Port) 擴充槽
內建IDE Ÿ IDE 控制器內建在AMD 756 PCI 晶片內,提供
內建周邊設備 Ÿ 1 個軟碟連接埠支援兩台磁碟機
硬體監控 (選購配備)
Ÿ AMD Athlon(K7) Slot A 處理器 Ÿ CPU 內建512 KB 2nd 快取記憶體 Ÿ 支援 500MHz ~ 1GHz 或更高速CPU
Ÿ AMD 751 PCI/AGP 控制器(PAC) Ÿ AMD 756 PCI ISA IDE 控制器
Ÿ 支援 SDRAM 16MB~768MB(最大) Ÿ 僅支援3.3V SDRAM DIMM
- 支援66 / 133 MHz 3.3V AGP-Bus 裝置
Ÿ 5 個32-bit 的PCI Bus 擴充槽 Ÿ 2 個16-bit 的ISA Bus 擴充槽
PIO, Bus Master , Ultra DMA/33ATA 66 操作模式 的IDE HDD/CD-ROM
Ÿ 可連接四個IDE裝置
Ÿ (360K ,720K ,1.2M ,1.44M 2.88M bytes) Ÿ 1 個並連連接埠可支援 SPP/EPP/ECP 模式 Ÿ 2 個串列埠 (COMA & COMB) Ÿ 4 個USB 連接埠 Ÿ 1 個紅外線連接端(可連接 Fast IrDA )
Ÿ CPU/電源供應器/系統風扇轉速偵測 Ÿ CPU 風扇控制 Ÿ CPU 過熱警報器 Ÿ 防侵入保護 Ÿ 顯示真實電壓值
3
Page 12
特色彙總
續下頁….
4
Page 13
7IXE Motherboard
PS/2 連接埠 BIOS Ÿ 使用經授權 AMI BIOS, 2M bit 快閃記憶體
附加特色 Ÿ 內接型/外接型數據機開機功能
Ÿ PS/2
Ÿ 鍵盤密碼開機功能 Ÿ 滑鼠開機功能 Ÿ 網路遠端開機功能 Ÿ 支援 AC back電源管理模式
鍵盤 連接埠及PS/2滑鼠連接埠
5
Page 14
Page 15
7IXE主機板
7IXE 主機板的元件配置圖
PS/2
JP10
USB
JP2
ATX POWER
COMA COMB
LPT
PCISLOT1
CPU
AGP
AMD751
J9
DIMM2
DIMM3
FLOPPY
IDE1
IDE2
DIMM1
BAT1
JP1
JP13
7IXE
BZ1
BIOS
J3
USB
JP5
J22
J6
JP12
ISA1
ISA2
PCISLOT2
PCISLOT3
PCISLOT4
PCISLOT5
JP4
SW1
AMD756
JP9
5
Page 16
7IXE主機板元件配置圖
$
CPU 速度設定 / 插座及接腳設定的快速安裝指南
插座 P.8 COMA / COMB串列插座 / LPT 並列插座 P.8 USB 規格插座 P.8 PS/2 鍵盤及PS/2 滑鼠插座 P.9 JP2 電源散熱風扇電源接腳 P.9 J9 CPU / J6系統散熱風扇電源接腳 P.10 ATX 電源插座 P.11 FLOPPY(軟碟插座) P.11 第一組IDE 1插座 / 第二組IDE 2插座 P.12 USB 接腳 P.12 IR(紅外線接腳) (選購配備) P.13 JP9 (內接式數據機接腳) P.13 JP4 (網路遠端開機) P.14 接腳定義說明 P.15 J22 (2x11 pins 接腳)說明 P.15 JP10 (鍵盤開機功能) P.16 JP1 (CASE OPEN) P.16 JP3 (清除CMOS功能) P.17
頁數
6
Page 17
7IXE主機板
1
2
3
1
2
3
1
2
3
1 2 3
1 23
1 2 3
CPU 速度設定
系統速度可藉由SW1調整到 90MHz, 95MHz, 100MHz, 105MHz, 110MHz and 115MHz
M請注意主機板上Jumper外頻的設定,需要和CPU的外頻相符合,否則易造成系 統當機。
SW1: CPU Speed Setup
90MHz
ON
95MHz
ON
100MHz
ON
4
SW1
105MHz
ON
4
SW1
圖1
M請依據您CPU的規格來設定CPU 的頻率,我們不建議您將系統速度設定超過硬
體之標準範圍,因為這些規格對於周邊設備而言並不算是符合標準規格。
4
SW1
110MHz
ON
4
SW1
4
SW1
115MHz
ON
4
SW1
7
Page 18
插座
1
2
COM A / COM B串列插座 / LPT 並列插座
LPT PORT
插座及接腳設定的快速安裝指南
COM A
COM B
USB 規格插座
接腳 定義
8 7 6 5
3
4
1 USB V0 2 USB D0­3 USB D0+ 4 接地線
5 USB V1 6 USB D1­7 USB D1+ 8 接地線
8
Page 19
7IXE主機板
PS/2 鍵盤及PS/2 滑鼠插座
PS/2 Mouse
4
PS/2 Keyboard
JP2 電源散熱風扇電源接腳
PS/2
鍵盤/滑鼠
接腳
1
6
2
5
3
1
2 3 4 VCC(+5V)
5 6
資料訊號線
無作用 接地線
無作用
定義
時脈
1
接腳 定義
1
接地線
2 +12V 3
感應線
9
Page 20
J9 CPU 散熱風扇電源接腳
插座及接腳設定的快速安裝指南
1
J6 系統散熱風扇電源接腳
接腳
1 2 +12V
3
接腳
1 2 +12V
3
定義
接地線
感應線
1
定義
接地線
感應線
10
Page 21
7IXE主機板
11 1
ATX 電源插座
FLOPPY : 軟碟插座
接腳 定義
10
20
3,5,7,13,15-17 接地線
1,2,11 3.3V
4,6,19,20 VCC
10 +12V 12 -12V 18 -5V
8 電源良好訊號 9 5V SB stand by+5V
14 PS-ON(Soft On/Off)
紅色線
11
Page 22
第一組IDE1插座/第二組IDE2 插座
插座及接腳設定的快速安裝指南
USB 接腳
5
8
IDE 1
4
1
紅色線
IDE 2
接腳
定義
1 VCC 2
USB D0 3 USB D0+ 4
接地線
5 VCC 6
USB D1 7 USB D1+ 8
接地線
12
Page 23
7IXE主機板
紅外線接腳 (選購配備
IR :
)
內接式數據機接腳
JP9 :
接腳
1 IR
1
2 3 IR 4 5
( Ring Power On)
1
接腳
1 2
資料輸出
接地線
資料輸入 無作用 電源線
定義 訊號線 接地線
定義
(+)
13
Page 24
JP4 : 網路遠端開機
插座及接腳設定的快速安裝指南
1
接腳
定義
1 +5V SB 2
3
接地線 訊號線
14
Page 25
7IXE主機板
接腳定義說明
J22 : For 2X11 Pins 接腳說明
GN : 省電模式開關 (Green Switch)
GD : 省電模式指示燈 (Green LED)
HD : 硬碟存取指示燈接頭 (IDE Hard Disk Active LED)
SPK : 內建蜂鳴器 (Speaker Connector)
RE : 重置開關接頭 (Reset Switch)
P+PP : 電源指示燈 (Power LED)
PW : 按鍵開/關機 (Soft Power Connector)
1
GN GD PW
1
HD
P
1
P+P
1
開路: 一般運作 短路: 進入省電模式
接腳 1: LED 燈號正極(+) 接腳 2: LED 燈號負極()
接腳 1: LED 燈號正極(+) 接腳 2: LED 燈號負極()
接腳 1: 電源線VCC(+) 接腳 2- 接腳 3: 無作用 接腳 4: 資料輸出線()
開路: 一般運作 短路: 強迫系統重新開機
接腳 1: LED 燈號正極(+) 接腳 2: LED 燈號負極() 接腳 2: LED 燈號負極()
開路: 一般運作 短路: 啟動電源開關
S P K
RE
15
Page 26
插座及接腳設定的快速安裝指南
16
Page 27
7IXE主機板
JP10 :
鍵盤開機功能
JP1 : CASE OPEN
1
接腳
1-2
短路 啟動鍵盤開機功能
2-3
短路 關閉鍵盤開機功能
(預設值)
1
接腳
1 2
定義 訊號線 接地線
定義
17
Page 28
JP3 : 清除 CMOS 功能
插座及接腳設定的快速安裝指南
1
接腳
1-2
短路 清除
2-3
短路 一般運作(預設值)
CMOS
(使用此功能必須將 1-2
短路直到開機完成)
定義
18
Page 29
Page 30
效能測試
效能測試
以下是7IXE的測試數據,基本上這些測試數值僅供參考,因為不同的軟、硬體配 備都會影響測試結果,所以我們無法保證使用者自行測試的數據會與下列公佈數 值完全吻合。
CPU AMD Athlon
記憶體
快取記憶體 CPU內建512 KB快取記憶體
顯示介面卡
儲存裝置
作業系統
驅動程式
TM
750MHz 處理器
(128x1) MB SDRAM (Hyundai Hy57V1298020 TC-75)
GA-660 32D (32MB) 內建 IDE 連接埠(硬碟Quantum KA13600AT) Windows NT™ 4.0 SPK5
顯示卡驅動程式使用 1024 x 768 x 64k colors x 75Hz 解析度 TUCD 1.3
Processor
AMD AthlonTM
750MHz(100x7.5)
Winbench99
CPU mark99 65.2
FPU Winmark 99 4150
Business Disk Winmark 99 5950
Hi-End Disk Winmark 99 13800
Business Graphics Winmark 99 363
Hi-End Graphics Winmark 99 697
Winstone99
Business Winstone99 41.4
Hi-End Winstone99 38.4
18
Page 31
7IXE主機板
9248-110/9179-06
W83977
晶片組功能方塊圖
AMD-K7TM
AGP
66MHz
5 PCI
ATA66 IDE
Channels
4 USB Ports
System Bus 100MHz
AMD
751
AMD
756
100MHz
66MHz
33MHz
33MHz
33MHz
100MHz
14.318MHz
3.3V SDRAM
100MHz
ICS
14.318MHz
BIOS
8MHz
COM Ports
LPT Ports
Winbond
PS/2
ISA Bus
Game Port
IR Floppy
19
Page 32
記憶體安裝指南
記憶體安裝指南
7IXE 主機板有3個(DIMM)擴充槽. BIOS 會自動偵測記憶體的規格及其大小. 安裝記憶 體只需將DIMM插入其插槽內即可, 由於記憶體模組有兩個凹痕, 所以只能以一個 方向插入,在不同的插槽,記憶體大小可以不同.
記憶體安裝組合如下表:
DIMM 168-pin SDRAM DIMM Modules DIMM 1 支援16 / 32 / 64 / 128 / 256 MB X 1 pcs DIMM 2 支援 16 / 32 / 64 / 128 / 256 MB X 1 pcs DIMM 3 支援 16 / 32 / 64 / 128 / 256 MB X 1 pcs
20
Page 33
7IXE主機板
$ BIOS組態設定目錄 頁數 主畫面功能 P.23 標準CMOS設定 P.25 進階BIOS功能設定 P.28 主機板晶片組的進階功能設定 P.31 省電功能設定 P.35 隨插即用與PCI組態設定 P.38 載入BIOS預設值 P.40 載入SETUP 預設值 P.41 整合週邊設定 P.42 電腦健康狀態 P.45 設定管理者(Supervisor)/使用者(User)密碼 P.47 自動偵測IDE硬碟 P.48 離開SETUP並儲存設定結果 P.49 離開SETUP但不儲存設定結果 P.50
21
Page 34
BIOS 組態設定
BIOS 組態設定
基本上主機板所附AMI BIOS便包含了CMOS SETUP程式,以供使用者自行依照需 求,設定不同的數據,使電腦正常工作,或執行特定的功能. CMOS SETUP會將各項數據儲存於主機板上內建的CMOS RAM中,當電源關閉時, 則由主機板上的鋰電池繼續供應CMOS RAM所需電力。ENTERING SETUP
當電源開啟之後,BIOS開始進行POSTPower On Self Test開機自我測試)時,按下Del>鍵便可進入AMI BIOSCMOS SETUP主畫面中。
如果您來不及在POST過程中按下<Del>鍵順利進CMOS SETUP,那麼可以補按
<Ctrl>+<Alt>+<Del>暖開機或按下機殼上的Reset按鈕,以重新開機再次進 POST程序,再按下<Del>鍵進入CMOS SETUP程式中。
操作按鍵說明
á(向上鍵) 移到上一個項目 â(向下鍵) 移到下一個項目 ß(向左鍵) 移到左邊的項目 à(向右鍵) 移到右邊的項目
Esc 回到主畫面,或從主畫面中結束SETUP程式 Page Up Page Down F1 功能鍵 F2 功能鍵 F3 功能鍵 F4 功能鍵 F5 功能鍵 可載入該畫面原先所有項目設定(但不適用主畫面) F6 功能鍵 可載入該畫面之BIOS預設設定(但不適用主畫面) F7 功能鍵 可載入該畫面之SETUP預設設定(但不適用主畫面) F8 功能鍵 F9 功能鍵 F10 功能鍵 儲存設定並離開CMOS SETUP 程式
改變設定狀態,或增加欄位中之數值內容 改變設定狀態,或減少欄位中之數值內容 可顯示目前設定項目的相關說明 功能保留 功能保留 功能保留
功能保留 功能保留
如何使用輔助說明
主畫面的輔助說明 當您在SETUP主畫面時,隨著選項的移動,底下便跟著顯示︰目前被選到的
SETUP項目的主要設定內容。
22
Page 35
7IXE主機板
設定畫面的輔助說明 當您在設定各個欄位的內容時,只要按下<F1>,便可得到該欄位的設定預
設值及所有可以的設定值,如BIOS預設值或CMOS SETUP預設值,若欲跳離輔 助說明視窗,只須按<Esc>鍵即可。
主畫面功能
當您進入CMOS SETUP設定畫面時,便可看到如下之主畫面,從主畫面中可以讓你 選擇各種不同之設定選單,你可以用上下左右鍵來選擇你要設定之選項並按Enter
進入子選單。
AMIBIOS SIMPLE SETUP UTILITY – VERSION 1.20
(C) 1998 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP PC HEALTH STATUS
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP / PCI CONFIGURATION IDE HDD AUTO DETECTION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING ESC: Quit
F6: Load BIOS Defaults F7: Load Setup Defaults F10:Save & Exit
↑↓→ ←
: Select Item (Shift)F2 : Change Color F5: Old Values
Time, Date , Hard Disk Type…
1: 主畫面功能
Standard CMOS Features (標準CMOS設定)
設定日期、時間、軟硬碟規格、及顯示器種類。
BIOS features setup(BIOS功能設定)
設定BIOS提供的特殊功能,例如病毒警告、開機磁碟優先順序、磁碟代號交
換....等。
23
Page 36
BIOS 組態設定
Chipset features setup (晶片組特性設定)
設定主機板採用的晶片組相關運作參數,例如「 DRAM Timing」、「 ISA Clock」....
等。
Power management setup(省電功能設定)
設定CPU、硬碟、GREEN螢幕等裝置的省電功能運作方式。
PNP/PCI configuration(即插即用與PCI組態設定)
設定ISAPnP即插即用介面以及PCI介面的相關參數。
Load BIOS defaults (載入BIOS預設值)
執行此功能可載入BIOSCMOS設定預設值,此設定是比較保守,但較能進 入開機狀態的設定值。
Load Setup defaults (載入Setup預設值)
執行此功能可載入SetupCMOS設定預設值,此設定是較能發揮主機板速 度的設定。
Integrated peripherals (整合週邊設定)
在此設定畫面包括所有週邊設備的的設定。如COM Port 使用的IRQ 位址,LPT
Port 使用的模式SPPEPPECP以及IDE 介面使用何種PIO Mode…..等。
PC Health Status (電腦健康狀態)
系統自動偵測電壓,溫度及風扇轉速等。
Supervisor password (管理者的密碼)
設定一個密碼,並適用於進入系統或進入SETUP修改CMOS設定。
User password (使用者密碼)
設定一個密碼,並適用於開機使用PC及進入BIOS修改設定 。
IDE HDD auto detection (自動偵測IDE硬碟)
自動偵測IDE的參數設定,並可選擇寫入CMOS(記得要存檔)。
Save & exit setup (儲存並結束)
儲存所有設定結果並離開SETUP程式,此時BIOS會重新開機,以便使用新的 設定值,按<F10>亦可執行本選項。
Exit without save (結束SETUP程式)
不儲存修改結果,保持舊有設定重新開機,按<ESC>亦可直接執行本選項。
24
Page 37
7IXE主機板
標準CMOS設定
STANDARD CMOS SETUP中,主要是為了設定IDE硬碟的種類,以順利開機,除 此之外,還有日期、時間、軟碟規格、及顯示卡的種類可以設定。
AMIBIOS SETUP – STANDARD CMOS SETUP
( C ) 1998 American Megatrends, Inc. All Rights Reserved Date (mm/dd/yyyy) : Mon, Sep 06, 1999 Time (hh/mm/ss) : 04:05:37
TYPE SIZE CYLS HEAD PRECOMP LANDZ SECTOR MODE Pri Master Auto Pri Slave Auto Sec Master Auto Sec Slave Auto
Floppy Drive A : 1.44 MB 3½ Floppy Drive B : Not Installed Other Memory : 384 Kb Extended Memory : 63 Mb Boot Sector Virus Protection : Disabled Total Memory : 64 Mb
Month : Jan – Dec ESC : Exit Day : 01– 31 ↑↓ : Select Item
Year : 1901 – 2099 PU / PD / + / – :Modify (Shift) F2 : Color
圖 2: 標準CMOS設定
Base Memory : 640 Kb
Date(mm:dd:yy) (日期設定)
即設定電腦中的日期,格式為「星期,月//年」,各欄位設定範圍如下表示:
星期 月(mm)
(dd) (yy)
由目前設定的「月//年」自萬年曆公式推算出今天為星期幾,
此欄位無法自行修改.
112.
128/29/30/31日,視月份而定.
19012099.
25
Page 38
BIOS 組態設定
Time(hh:mm:ss) (時間設定)
即設定電腦中的時間是以24小時為計算單位,格式為「時:分:秒」舉例而 言,下午一點表示方式為13 : 00 : 00。當電腦關機後,RTC功能會繼續執行, 並由主機板的電池供應所需電力。
IDE Primary Master (Slave) / IDE Secondary Master (Slave) (第一組硬碟/第二組硬碟參
數設定) 設定第一、二組IDE硬碟參數規格,設定方式有兩種,建議的是設定方式是採
方式1,但經常更換IDE硬碟的使用者則可採方式2,省去每次換硬碟都要重新 設定CMOS的麻煩。
方式1:設成User TYPE ,自行輸入下列相關參數,即CYLS、HEADS、SECTORS、 MODE,以便順利使用硬碟。
方式2:設定AUTO,將TYPEMODE皆設定AUTO,讓BIOSPOST過程中,自 動測試IDE裝置的各項參數直接採用。
CYLS. Number of cylinders(磁柱的數量). HEADS number of heads(磁頭的數量). PRECOMP write precomp. LANDZONE Landing zone. SECTORS number of sectors(磁區的數量).
如果沒有裝設硬碟,請選擇”NONE後按<Enter>
Drive A / Drive B (軟式磁碟機 A:/ B:種類設定)
可設定的項目如下表示:
None 沒有安裝磁碟機. 360K, 5.25 in.
1.2M, 5.25 in. 720K, 3.5 in.
1.44M, 3.5 in.
2.88M, 3.5 in.
5.25吋磁碟機,360KB容量.
5.25吋磁碟機,1.2MB容量. 3吋半磁碟機,720KB容量. 3吋半磁碟機,1.44MB容量. 3吋半磁碟機,2.88MB容量.
Floppy 3 Mode Support (支援日本常用之 3 Mode規格軟碟)
Disabled Drive A Drive B Both
沒有安裝任何3 Mode軟碟. A:安裝的是3 Mode軟碟. B:安裝的是3 Mode軟碟. A:B:安裝的都是3 Mode軟碟.
26
Page 39
7IXE主機板
Video(顯示界面種類設定)
設定電腦之要顯示介面,包括以下各種選擇:
EGA/VGA 加強型顯示介面,EGA, VGA, SVGA, or PGA彩色螢幕均選此項. CGA 40 CGA 80 MONO
Color Graphics Adapter,40行顯示模式. Color Graphics Adapter,80行顯示模式. 黑白單色介面.
Halt on(暫止選項設定)
當開機時,若POST偵測到異常,是否要提示,並等候處理?可選擇的項目有:
NO Errors All Errors All, But Keyboard All, But Diskette All, But Disk/Key
不管任何錯誤,均開機 有何錯誤均暫停等候處理 有何錯誤均暫停,等候處理,除了鍵盤以外 有何錯誤均暫停,等候處理,除了軟碟以外 有何錯誤均提示,等候處理,除了軟碟、鍵盤以外
Memory(記憶體容量顯示)
目前主機板所安裝的記憶體皆由BIOSPOST(Power On Self Test)自動偵測,並 顯示於STANDARD CMOS SETUP右下方。
Base Memory:傳統記憶體容量
PC一般會保留640KB容量做為MS-DOS作業系統的記憶體使用空間。
Extended Memory:延伸記憶體容量
可做為延伸記憶體的容量有多少,一般是總安裝容量扣除掉Base Other Memory之後的容量,如果數值不對,可能是有Module沒安裝好, 請仔細檢查。
27
Page 40
BIOS 組態設定
進階 BIOS 功能設定
AMIBIOS SETUP – BIOS FEATURES SETUP
( C ) 1998 American Megatrends, Inc. All Rights Reserved
Quick Boot Enabled 1st Boot Device Floppy 2nd Boot Device IDE-0
3rd Boot Device CDROM
Try Other Boot Devices Yes
Floppy Access Control Read-Write
Hard Disk Access Control Read-Write
BootUp Num-Lock On
Floppy Drive Swap Disabled
Floppy Drive Seek Disabled
Security Option Setup
Boot To OS/2 > 64MB No BIOS Write Protect Disabled C000, 32K Shadow Cached
C800, 16K Shadow Disabled
CC00, 16K Shadow Disabled
D000, 16K Shadow Disabled F1 : Help PU/PD+/-/ : Modify
D400, 16K Shadow Disabled F5 :Old Values(Shift)F2:Color
D800, 16K Shadow Disabled F6 : Load BIOS Defaults
DC00, 16K Shadow Disabled F7 : Load Setup Defaults
ESC: Quit
↑↓→ ←
: Select Item
3: 進階 BIOS 功能設定
Quick Boot(快速開機自我測試)
設定BIOS採用快速的POST方式,也就是簡化測試的方式與次數,讓POST過 程所需時間縮短。無論設成EnabledDisabled,當POST進行時,仍可按<Esc> 跳過測試,直接進入開機程序
Enabled Disabled
採用快速POST方式.(預設值) 不採用快速POST方式.
First / Second / Third Boot device (第一//三次開機裝置)
Floppy 由軟碟機為第一次優先的開機裝置. LS/ZIP LS/ZIP為第一次優先的開機裝置. HDD-0~3 由硬碟機為第一次優先的開機裝置. SCSI SCSI裝置為第一次優先的開機裝置. CDROM 由光碟機為第一次優先的開機裝置. Disable 關閉此功能. LAN 由網路卡為第一次優先的開機裝置.
28
Page 41
7IXE主機板
Try Other Boot Device(由其它裝置開機)
Yes No
啟動由其它裝置開機.(預設值) 關閉由其它裝置開機.
Floppy Access Control (軟碟機存取控制)
Read-Write 設定軟碟機存取控制為Read-Write. (預設值) Read-Only 設定軟碟機存取控制為Read-Only.
HDD Access Control (硬碟存取控制)
Read-Write 設定硬碟存取控制為Read-Write. (預設值) Read-Only 設定硬碟存取控制為Read-Only.
Boot Up Num-Lock (起始時數字鍵鎖定狀態)
On Off
開機後將數字區設成數字鍵功能.(預設值) 開機後將數字區設成方向鍵功能.
Floppy Drive Swap(交換軟碟代號)
Enabled Disabled
DOS模式下,A:B:的磁碟位置對調. A:B:位置維持正常. (預設值)
Floppy Drive Seek(開機時測試軟碟)
設定在PC開機時,POST程式需不需要對FLOPPY做一次SEEK測試。可設定的 項目為:
Enabled Disabled
要對Floppy做Seek測試. 不必對Floppy做Seek測試. (預設值)
Security Option(檢查密碼方式)
System Setup
M 欲取消密碼之設定時,只要於SETUP內重新設定密碼時,不要按任何鍵,
接按<Enter>使密碼成為空白,即可取消密碼的設定。
無論是開機或進入CMOS SETUP均要輸入密碼. 只有在進入CMOS SETUP時才要求輸入密碼.(預設值)
29
Page 42
OS Select For DRAM>64MB(設定OS2使用記憶體容量)
BIOS 組態設定
No Yes
BIOS Write Protect (BIOS 防寫保護)
Enabled 起動BIOS防寫保護. Disabled 關閉BIOS防寫保護. (預設值)
C000 32K Shadow- DC00 16K Shadow (特定區塊Shadow)
設定以下區域,是否也要做Shadow動作,每一屈塊皆為16K.當您安裝其他介面 卡介(如SCSI卡),若卡上有BIOS,即可設定正確位址開啟Shadow功能.
Enabled 啟動Optional shadow. Disabled 關閉Optional shadow . Cached 設定Optional shadow為快取.
非使用IBM OS/2作業系統.(預設值) 使用IBM OS2,且DRAM容量大於64MB.
30
Page 43
7IXE主機板
主機板晶片組的進階功能設定
AMIBIOS SETUP – CHIPSET FEATURES SETUP
( C ) 1998 American Megatrends, Inc. All Rights Reserved
**** SDRAM Timing **** Config SDRAM Timing Manual *SDRAM PH Limit 32 Cycles
*SDRAM Idle Cycle Limit 8 Cycles
*SDRAM TRC Bank Cycle Time 7 Cycles
*SDRAM TRP SRAS Precharge 2 Cycles
*SDRAM TRAS Timing 5 Cycles
*SDRAM CAS Latency 3 Cycles
*SDRAM TRCD Timing 3 Cycles
DRAM Integrity Mode Disabled
Memory Hole Disabled
DRAM Burst Refresh Enabled
Graphics Aperture Size 64MB USB Function Enabled
USB KB Legacy Support Disabled ESC: Quit
F1 : Help PU/PD+/-/ : Modify
F5 :Old Values(Shift)F2:Color
F6 : Load BIOS Defaults
F7 : Load Setup Defaults
↑↓→ ←
: Select Item
4: 主機板晶片組的進階功能設定
* Config SDRAM Timing 設為Manual時,此7項有星號的項目才會被啟動.
Config SDRAM Timing
Auto 設定 Config SDRAM Timing Auto. Manual 設定 Config SDRAM Timing Manual. ( 預設值 )
SDRAM PH Limit
This function specify the number of consecutive Page-Hit requests to allow before choosing a non-Page-Hit request.
1 Cycle 設定 SDRAM PH Limit 1 Cycle. 4 Cycle 設定 SDRAM PH Limit 4 Cycle. 32 Cycle 設定 SDRAM PH Limit 32 Cycle. ( 預設值 ) 64 Cycle 設定 SDRAM PH Limit 64 Cycle.
31
Page 44
BIOS 組態設定
SDRAM Idle Cycle Limit
This function specify the number of idle cycles to wait before precharging an idle bank.(Idle cycles are defined as cycles where no valid request is asserted to the MCT.)
0 Cycles 設定 SDRAM Idle Limit to 0 Cycles. 8 Cycles 設定SDRAM Idle Limit to 8 Cycles. ( 預設值 ) 12 Cycles 設定SDRAM Idle Limit to 12 Cycles. 16 Cycles 設定SDRAM Idle Limit to 16 Cycles. 24 Cycles 設定SDRAM Idle Limit to 24 Cycles. 32 Cycles 設定SDRAM Idle Limit to 32 Cycles. 48 Cycles 設定SDRAM Idle Limit to 48 Cycles. Disabled 關閉此功能.
SDRAM TRC Bank Cycle Time
This function specify the minimum time from activate to activate of the same bank.
3 Cycle 設定 SDRAM TRC Bank Cycle Time 3 Cycle. 4 Cycle 設定 SDRAM TRC Bank Cycle Time 4 Cycle. 5 Cycle 設定 SDRAM TRC Bank Cycle Time 5 Cycle. 6 Cycle 設定 SDRAM TRC Bank Cycle Time 6 Cycle. 7 Cycle 設定 SDRAM TRC Bank Cycle Time 7 Cycle. ( 預設值 ) 8 Cycle 設定 SDRAM TRC Bank Cycle Time 8 Cycle.
SDRAM TRP SRAS Precharge
This function specify the delay from precharge command to activate command.
3 Cycle 設定 SDRAM TRP SRAS Precharge 3 Cycle. 2 Cycle 設定 SDRAM TRP SRAS Precharge 2 Cycle. ( 預設值 )
SDRAM TRAS Timing
This function specify the minimum bank (SRAS[2:0]#) active time.
2 Cycle 設定 SDRAM TRAS Timing Value 2 Cycle. 3 Cycle 設定 SDRAM TRAS Timing Value 3 Cycle. 4 Cycle 設定 SDRAM TRAS Timing Value 4 Cycle. 5 Cycle 設定 SDRAM TRAS Timing Value 5 Cycle. ( 預設值 ) 6 Cycle 設定 SDRAM TRAS Timing Value 6 Cycle.
32
Page 45
7IXE主機板
7 Cycle 設定 SDRAM TRAS Timing Value 7 Cycle.
33
Page 46
SDRAM CAS Latency
This function specify the delay from SCAS[2:0]# to data valid.
2 Cycles 設定SDRAM CAS Latency to 2 Cycles. 3 Cycles 設定SDRAM CAS Latency to 3 Cycles.( 預設值 )
SDRAM TRCD Timing
1 Cycle 設定 SDRAM Trcd Timing Value 1 Cycle. 2 Cycle 設定 SDRAM Trcd Timing Value 2 Cycle. 3 Cycle 設定 SDRAM Trcd Timing Value 3 Cycle. ( 預設值 ) 4 Cycle 設定 SDRAM Trcd Timing Value 4 Cycle.
DRAM Integrity Mode
Disabled Disabled this function.( 預設值 ) ECC 設定DRAM Integrity Mode to ECC.
Memory Hole (保留記憶體 15M~16M之間)
Disabled Normal Setting. (預設值) 14MB-15MB 設定Address=14~15MB remap to ISA BUS. 15MB-16MB 設定Address=15~16MB remap to ISA BUS. 14MB-16MB 設定Address=14~16MB remap to ISA BUS.
BIOS 組態設定
DRAM Burst Refresh
Disabled Disabled this function. Enabled Enabled DRAM Burst Refresh function.( 預設值 )
Graphics Aperture Size
64 MB Display Graphics Aperture Size 64MB (預設值) 32 MB Display Graphics Aperture Size 32MB 16 MB Display Graphics Aperture Size 16MB 4 MB Display Graphics Aperture Size 4MB 8 MB Display Graphics Aperture Size 8MB 128 MB Display Graphics Aperture Size 128MB 256 MB Display Graphics Aperture Size 256MB
34
Page 47
7IXE主機板
35
Page 48
USB Function(通用序列匯流排功能)
Disabled 不啟動USB 功能. Enabled 啟動USB 功能. (預設值)
USB KB Legacy Support
啟動USB 功能,USB的支援形態將可被設定.
Disabled Disable USB 鍵盤Legacy Support. (預設值) Keyb+ Mouse 支援USB 鍵盤和USB 滑鼠. Keyboard 支援USB 鍵盤.
BIOS 組態設定
36
Page 49
7IXE主機板
省電功能設定
AMIBIOS SETUP – POWER MANAGEMENT SETUP
( C ) 1998 American Megatrends, Inc. All Rights Reserved
Power Management/APM Enabled Data (of Month) Alarm 15 Video Power Down Mode Suspend Hour Alarm 12 Hard Disk Power Down Mode Suspend Minute Alarm 30 Suspend Time Out (Minute) Disabled Second Alarm 30 Display Activity Ignore Keyboard PowerOn Function Disabled
IRQ3 Both Password for PowerOn N/A IRQ4 Both Mouse PowerOn function Disabled IRQ5 Ignore IRQ7 Both IRQ9 Both IRQ10 Both IRQ11 Both IRQ13 Both IRQ14 Both IRQ15 Both Soft-off by Power Button Instant Off System after AC Back Memory F1 : Help PU/PD+/-/ : Modify
Modem Ring On/Wake On Lan
PME Event Wake Up Disabled F6 : Load BIOS Defaults Resume by Alarm Disabled F7 : Load Setup Defaults
Enabled F5 :Old Values(Shift)F2:Color
ESC: Quit
↑↓→ ←
: Select Item
5: 省電功能設定
Power Management / APM(省電功能)
Enabled 依照APM標準來做省電功能管理. (預設值) Disabled 不依照APM標準做省電功能管理.
Video Power Down Mode
Disabled 不使用此功能. Suspend 設定螢幕關閉時,會進入Suspend省電模式. (預設值) Stand By 設定螢幕關閉時,會進入Stand By省電模式.
Hard Disk Power Down Mode(硬碟電源關閉模式)
Disabled 不使用此功能. Suspend 設定硬碟關閉時,會進入Suspend省電模式. (預設值) Stand By 設定硬碟關閉時,會進入Stand By省電模式.
37
Page 50
Suspend Time Out (Minute)
Disabled 不設定此功能. (預設值) 1 設定電腦離線1分鐘後進入Suspend省電模式. 2 設定電腦離線2分鐘後進入Suspend省電模式. 4 設定電腦離線4分鐘後進入Suspend省電模式. 8 設定電腦離線8分鐘後進入Suspend省電模式. 10 設定電腦離線10分鐘後進入Suspend省電模式. 20 設定電腦離線20分鐘後進入Suspend省電模式. 30 設定電腦離線30分鐘後進入Suspend省電模式. 40 設定電腦離線40分鐘後進入Suspend省電模式. 50 設定電腦離線50分鐘後進入Suspend省電模式. 60 設定電腦離線60分鐘後進入Suspend省電模式.
Display Activity
Ignore 忽略螢幕顯示動作而進入省電模式. (預設值) Monitor 監督螢幕顯示動作而不進入省電模式
IRQ[3,4,5,7,8,9,10,11,13,14,15]
Ignore 設定IRQ to Ignore. Both 設定IRQ to Both. WakeUp 設定IRQ to WakeUP. Monitor 設定IRQ to Monitor.
BIOS 組態設定
Soft-off by Power Button(關機方式)
Instant-off 按一下Soft-off開關便直接關機.(預設值) Delay 4 Sec. 需按住Soft-off 開關4秒後才關機.
System after AC Back 斷電後,電源回復時的系統狀態選擇)
Memory 電源回復時,恢復系統斷電前狀態. (預設值) Full-On 電源回復時,立刻啟動系統. Soft-Off 需按Soft PWR button才能重新啟動系統.
ModemRingOn/WakeOnLan (數據機開機/網路開機狀態)
Disabled 不啟動數據機開機/網路開機功能. Enabled 啟動數據機開機/網路開機功能. (預設值)
38
Page 51
7IXE主機板
PME Event Wake Up(電源管理事件喚醒功能)
Disabled 不啟動電源管理事件喚醒功能. (預設值) Enabled 啟動電源管理事件喚醒功能.
Resume by Alarm(定時開機)
Disabled 不啟動此功能.(預設值) Enabled 啟動此功能.
若啟動定時開機,則可設定以下時間:
Data(of Month) Alarm : 0~31 Hour Alarm: 0~23 Minute Alarm : 0~59 Second Alarm : 0~59
Keyboard PowerOn Function ( 鍵盤開機)
Disabled 關閉鍵盤開機功能.(預設值) Password 自設1-5個字元為鍵盤開機密碼. Power Key 若是您的鍵盤上有”POWER Key”此鍵,則可以由此鍵開機.
Password for PowerOn
Enter 自設
個字元為鍵盤開機密碼..
1-5
Mouse PowerOn Function (滑鼠開機)
Disabled 關閉PS/2 滑鼠開機功能. (預設值) Left-button Right-button
按兩次PS/2滑鼠左鍵開機. 按兩次PS/2滑鼠右鍵開機.
39
Page 52
隨插即用與PCI組態設定
AMIBIOS SETUP – PNP / PCI CONFIGURATION
( C ) 1998 American Megatrends, Inc. All Rights Reserved
PnP OS Installed No Reset Configuration Data No PCI Latency Timer 64
VGA Boot from AGP
PCI VGA Palette Snoop Disabled
DMA Channel 0
DMA Channel 1 PnP
DMA Channel 3 PnP
DMA Channel 5 PnP
DMA Channel 6
DMA Channel 7 PnP
IRQ 3 PCI/PnP
IRQ 4 PCI/PnP
IRQ 5 PCI/PnP
IRQ 7 PCI/PnP
IRQ 9 PCI/PnP
IRQ 10 PCI/PnP
IRQ 11 PCI/PnP F1 : Help PU/PD+/-/ : Modify
IRQ 14 PCI/PnP F5 :Old Values(Shift)F2:Color
IRQ 15 PCI/PnP F6 : Load BIOS Defaults
F7 : Load Setup Defaults
PnP
PnP
ESC: Quit
↑↓→ ←
: Select Item
6: 隨插即用與PCI組態設定
PNP OS Installed(是否安裝即插即用作業系統)
BIOS 組態設定
作業系統是否支援PnP即插即用功能,如Windows 95
Yes 是的,安裝的OS有支援PnP. No 沒有支援(MS-DOS).(預設值)
Reset Configuration Data(清除組態資料)
指示BIOS將所有PnP等相關組態清除,以便寫入或恢復部份預設值。
No 不執行Reset Configuration Data. (預設值) Yes 清除在ESCD內的隨插隨用資料.
40
Page 53
7IXE主機板
PCI Latency Timer
32 設定 PCI Latency Timer to 32. 64 設定PCI Latency Timer to 64. (預設值) 96 設定PCI Latency Timer to 96. 128 設定PCI Latency Timer to 128. 160 設定PCI Latency Timer to 160. 192 設定PCI Latency Timer to 192. 224 設定PCI Latency Timer to 224. 248 設定PCI Latency Timer to 248.
VGA Boot from
AGP 主要的圖形顯示插槽為 AGP. (預設值) PCI 主要的圖形顯示插槽為 PCI.
PCI/VGA Palette Snoop(顏色校正)
當您安裝MPEG後,若發現顯示顏色異常,可試設定此值為Enabled,以校正 顏色輸出。
Enabled 要作顏色校正動作. Disabled 不需要作顏色校正動作.(預設值)
IRQ (3,4,5,7,9,10,11,12,14,15), DMA(0,1,3,5,6,7) assigned to
( Legacy ISA or "PCI/ISA PnP ) 以上IRQ資源也是以往PC固定在使用的,如 COM 1(IRQ 4)、COM 2(IRQ 3)、LPT(IRQ
7)IDE(IRQ 14,15),其餘IRQ5/9/10/11DMA 0,1,3,5,6,7則由BIOS做為分配給其
PnP介面的資源,如VGA卡、音效卡、網路卡....等。
Legacy ISA 指定給傳統(Legacy)ISA介面卡使用. PCI/ISA PnP 指定給PCI或ISA有PnP功能的介面卡使用.
41
Page 54
載入BIOS預設值
AMIBIOS SIMPLE SETUP UTILITY-VERSION 1.20
( C ) 1998 American Megatrends, Inc. All Rights Reserved STANDARD CMOS SETUP INTEGRATED PERIPHERALS BIOS FEATURES SETUP PC HEALTH STATUS CHIPSET FEATURES SETUP SUPERVISOR PASSWORD POWER MANAGEMENT SETUP USER PASSWORD PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION LOAD BIOS DEFAULTS SAVE & EXIT SETUP LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
Load BIOS Defaults except Standard CMOS SETUP
Load BIOS Defaults (Y/N)?
7: 載入BIOS預設值
Load BIOS Defaults
請按<Y>、<Enter>,即可載入BIOS預設值。
BIOS 組態設定
42
Page 55
7IXE主機板
載入SETUP預設值
AMIBIOS SIMPLE SETUP UTILITY-VERSION 1.20
( C ) 1998 American Megatrends, Inc. All Rights Reserved STANDARD CMOS SETUP INTEGRATED PERIPHERALS BIOS FEATURES SETUP PC HEALTH STATUS CHIPSET FEATURES SETUP SUPERVISOR PASSWORD POWER MANAGEMENT SETUP USER PASSWORD PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION LOAD BIOS DEFAULTS SAVE & EXIT SETUP LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
Load Setup Defaults except Standard CMOS SETUP
Load SETUP Defaults (Y/N)?
8: 載入SETUP預設值
Load Setup Defaults
請按<Y>、<Enter>,即可載入Setup預設值。
43
Page 56
BIOS 組態設定
整合週邊設定
AMIBIOS SETUP – INTEGRATED PERIPHERALS
( C ) 1998 American Megatrends, Inc. All Rights Reserved
OnBoard IDE Both
OnBoard FDC Auto OnBoard Serial Port A OnBoard Serial Port B Auto
Serial PortB Mode Normal
*IR Duplex Mode N/A
OnBoard Parallel Port Auto
Parallel Port Mode SPP
**Parallel Port IRQ Auto
# Parallel Port DMA N/A
F1 : Help PU/PD+/-/ : Modify
F5 :Old Values(Shift)F2:Color
F6 : Load BIOS Defaults
F7 : Load Setup Defaults
Auto
9: 整合週邊設定
*”Serial PortB Mode” 設為 IrDA 時此項才被啟動.
**”Onboard Parallel Port” 設為 378,278,3BC時此項才被啟動.
#”Onboard Parallel Port” 設為 378,278,3BC,並且”Parallel Mode”設為”ECP”, 此項才被啟
動.
ESC: Quit
↑↓→ ←
: Select Item
On Board IDE (內建IDE介面)
Disabled 關閉內建IDE介面. Both 設定內建IDE介面為 Both.(預設值). Primary 設定內建IDE介面為Primary. Secondary 設定內建IDE介面為Secondary.
On Board FDC (內建軟碟介面)
Enabled 要使用主機板內建的軟碟介面. Disabled 不使用主機板內建的軟碟介面. Auto 自動偵測主機板內建的軟碟介面.(預設值)
44
Page 57
7IXE主機板
On Board Serial Port A(內建串列插座介面A)
Auto BIOS自動設定. (預設值) 3F8/COM1 指定內建串列插座A且使用3F8位址. 2F8/COM2 指定內建串列插座A且使用2F8位址. 3E8/COM3 指定內建串列插座A且使用3E8位址. 2E8/COM4 指定內建串列插座A且使用2E8位址. Disabled 關閉內建串列插座A.
Onboard Serial Port B (內建串列插座介面B)
Auto BIOS自動設定. (預設值) 3F8/COM1 指定內建串列插座B且使用3F8位址. 2F8/COM2 指定內建串列插座B且使用2F8位址. 3E8/COM3 指定內建串列插座B且使用3E8位址. 2E8/COM4 指定內建串列插座B且使用2E8位址. Disabled 關閉內建串列插座B.
Serial Port B Mode (此功能要遵循主機板上I/O 是否支援IR功能)
ASKIR 主機板上I/O有支援ASKIR.. IrDA Normal 主機板上I/O支援正常模式.(預設值)
主機板上I/O有支援IrDA
IR Duplex Mode
Half Duplex Full Duplex
設定IR 模式為半雙工. (預設值) 設定IR 模式為全雙工.
On Board Parallel Port (內建並列插座)
378 278 3BC 指定內建並列插座位址為3BC. Auto 將內建並列插座位址設為自動偵測. (預設值) Disabled 關閉內建的並列插座.
指定內建並列插座位址為378. 指定內建並列插座位址為278.
45
Page 58
Parallel Port Mode (並列插座模式)
EPP 使用EPPEnhanced Parallel Port)傳輸模式. ECP 使用ECPExtended Capabilities Port)傳輸模式.(預設值) Normal 支援一般速度單向傳輸.
Parallel Port IRQ (並列插座IRQ設定)
7 設定 Parallel Port IRQ 7. 5 設定 Parallel Port IRQ 5. Auto 設定 Parallel Port IRQ 自動偵測. (預設值)
Parallel Port DMA (並列插座DMA設定)
3 設定 3 Parallel Port DMA . 1 設定 1 Parallel Port DMA . Auto 設定 Parallel Port DMA 為自動偵測. (預設值)
BIOS 組態設定
46
Page 59
7IXE主機板
電腦健康狀態
AMIBIOS SETUP – PC HEALTH STATUS
( C ) 1998 American Megatrends, Inc. All Rights Reserved
Reset Case Open Status No 5V SB 4.896 V
Case Open No Shut Down Temperature CPU Temperature Alarm Current CPU Temperature
CPU Fan Fail Alarm No
Power Fan Fail Alarm
System Fan Fail Alarm No
Current CPU Fan Speed 5273 RPM
Current Power Fan Speed 0 RPM
Current System Fan Speed 0 RPM
Current System Temp.
Vcore 1.620 V
Vcache 3.310 V
Vcc3 3.312 V
+5.000V 5.030 V
+12.000V 11.923 V F1 : Help PU/PD+/-/ : Modify
-12.000V -11.579 V F5 :Old Values(Shift)F2:Color
-5.000V -4.675 V F6 : Load BIOS Defaults
Battery 3.040V F7 : Load Setup Defaults
70°C/ 158°F 65°C/ 149°F
34°C/ 93°F
No
29°C/ 84°F
ESC: Quit
↑↓→ ←
: Select Item
10: 電腦健康狀態
Reset Case Open Status
重置Case Opened 狀況
Case Opened
如果您的電腦外殼是關閉的, “ Case Opened” 這項值將會是 “No”. 如果您的電腦外殼是曾經被打開的, “ Case Opened” 這項值將會是 “YES”. 如果您希望重置 “Case Opened” 的值,將 ”Reset Case Open Status” 的值設為 “Yes” 並 重新開機即可.
47
Page 60
Shut Down Temperature
(此功能僅在系統有支援ACPI 模式下有效)
Disabled 關閉此功能. 65°C / 149°F 監控 CPU 溫度在 65°C / 149°F, 若溫度 > 65°C / 149°F 系統
將自動關機.
70°C / 158°F 監控 CPU 溫度在 70°C / 158°F, 若溫度 > 70°C / 158°F 系統
將自動關機.(預設值)
75°C / 167°F 監控 CPU 溫度在 75°C / 167°F, 若溫度 > 75°C / 167°F 系統
將自動關機
CPU Temperature Alarm (CPU溫度設定值)
Disabled 關閉此功能. 65°C / 149°F 偵測CPU設定值 65°C / 149°F.(預設值) 70°C / 158°F 偵測CPU設定值 70°C / 158°F. 75°C / 167°F 偵測CPU設定值 75°C / 167°F.
Current CPU Temperature (°C / °F)
自動偵測CPU 溫度
Fan Fail Alarm (CPU/ Power/System 風扇故障警告功能)
BIOS 組態設定
Yes 啟動CPU / Power / System 風扇故障警告. No 關閉CPU / Power / System 風扇故障警告. (預設值)
Current CPU FAN / System FAN / Power FAN Speed (RPM)
自動偵測風扇的轉速
Current System Temp. (°C / °F)
自動偵測系統溫度
Current Voltage (v) Vcore / Vcache / VCC3 / ±12V / ±5V /VBAT / 5V SB
自動偵測VCORE / VSRAM / VCC3 / ±12V / ±5V /VBAT / 5V SB
48
Page 61
7IXE主機板
管理者(Supervisor)/使用者(User)密碼
當您想設定密碼時,請於主畫面下選擇好項目,並按下Enter,畫面中間即出現的 方框讓您輸入密碼:
AMIBIOS SIMPLE SETUP UTILITY-VERSION 1.20
( C ) 1998 American Megatrends, Inc. All Rights Reserved STANDARD CMOS SETUP INTEGRATED PERIPHERALS BIOS FEATURES SETUP PC HEALTH STATUS CHIPSET FEATURES SETUP SUPERVISOR PASSWORD POWER MANAGEMENT SETUP USER PASSWORD PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION LOAD BIOS DEFAULTS SAVE & EXIT SETUP LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
11: 設定管理者 (Supervisor)/使用者(User)密碼
最多可以輸入8個字元,輸入完畢後按下Enter,BIOS會要求再輸入一次,以確定剛 剛沒有打錯,若兩次密碼吻合,便將之記錄下來。 如果您想取消密碼,只需在輸入新密碼時,直接按Enter,這時BIOS會顯示 「PASSWORD DISABLED」,也就是關閉密碼功能,那麼下次開機時,就不會再被 要求輸入密碼了。
SUPERVISOR 密碼的用途
v
當您設定了Supervisor密碼時,當如果「 BIOS FEATURES SETUP」中的Security option項目設成SETUP,那麼開機後想進入CMOS SETUP就得輸入Supervisor密碼 才能進入。
USER 密碼的用途
v
當您設定了User密碼時,當如果「 BIOS FEATURES SETUP」中 的Security option 項目設成SYSTEM,那麼一開機時,必需輸入User或Supervisor密碼才能進入開 機程序。當您想進入CMOS SETUP時,如果輸入的是USER Password,很抱歉, BIOS是不會允許的,因為只有Supervisor可以進入CMOS SETUP中。
Enter new supervisor password:
Change / Set / Disable Password
49
Page 62
BIOS 組態設定
自動偵測IDE硬碟
AMIBIOS SETUP – STANDARD CMOS SETUP
( C ) 1998 American Megatrends, Inc. All Rights Reserved
Date (mm/dd/yyyy) : Fri Dec 25, 1998 Time (hh/mm/ss) : 10:36:24 TYPE SIZE CYLS HEAD PRECOMP LANDZ SECTOR MODE
Pri Master : Auto Pri Slave : Auto Sec Master: Auto Sec Slave : Auto
Floppy Drive A: 1.44 MB 3 ½ Floppy Driver B: Not Installed
Boot Sector Virus Protection : Disabled Month: Jan – Dec ESC : Exit
Day: 01 – 31 ↑↓ : Select Item Year : 1901– 2099 PU/PD/+/– : Modify (Shift)F2 : Color
12: 自動偵測IDE硬碟
當BIOS偵測出結果時,通常會有三種Mode可供選擇,即Normal、LBALARGE 而目前的BIOS多會將LBA擺在第一項,因此只需按Y,即可將參數寫入STANDARD CMOS中,但記得離開CMOS時要存檔。
Base Memory : 640 kb Other Memory: 384 kb Extended Memory: 31mb Total Memory: 32mb
50
Page 63
7IXE主機板
離開SETUP並儲存設定結果
AMIBIOS SIMPLE SETUP UTILITY-VERSION 1.20
( C ) 1998 American Megatrends, Inc. All Rights Reserved STANDARD CMOS SETUP INTEGRATED PERIPHERALS BIOS FEATURES SETUP PC HEALTH STATUS CHIPSET FEATURES SETUP SUPERVISOR PASSWORD POWER MANAGEMENT SETUP USER PASSWORD PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION LOAD BIOS DEFAULTS SAVE & EXIT SETUP LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
若按Y並按下Enter,即可儲存所有設定結果到RTC中的CMOS RAM 並離開Setup Utility。若不想儲存,則按NEsc皆可回到主畫面中。.
SAVE to CMOS and EXIT(Y/N)? Y
Save Data to CMOS & Exit SETUP
13: 離開SETUP並儲存設定結果
51
Page 64
離開SETUP但不儲存設定結果
AMIBIOS SIMPLE SETUP UTILITY-VERSION 1.20
( C ) 1998 American Megatrends, Inc. All Rights Reserved STANDARD CMOS SETUP INTEGRATED PERIPHERALS BIOS FEATURES SETUP PC HEALTH STATUS CHIPSET FEATURES SETUP SUPERVISOR PASSWORD POWER MANAGEMENT SETUP USER PASSWORD PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION LOAD BIOS DEFAULTS SAVE & EXIT SETUP LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
若按Y並按下Enter,則離開Setup Utility。若按NEsc則可回到主畫面中
Quit without saving(Y/N)? N
Abandon all Datas & Exit SETUP
14: 離開SETUP但不儲存設定結果
BIOS 組態設定
52
Page 65
7IXE主機板
附錄
附錄 A: 內建驅動程式安裝步驟
1.按下 “General” 項目.
2. 按下“AMD EIDE Driver” 項目.
5. 按下“OK”.
(1)
3. 按下“Next”.
(3)
(5)
(2)
4. 按下“Next”.
(4)
6. 按下“Finish” 來重新啟 動您的電腦.
(6)
51
Page 66
附錄
B. AMD AGP Miniport Driver
Insert the support CD that came with your motherboard into your CD-ROM drive or double-click the CD drive icon in My Computer to bring up the setup screen.
2. 按下“AMD AGP Miniport Driver” 項目.
1.按下“General” 項目.
(1)
3. 按下“Next”.
(3)
(2)
4. 按下“Finish”.
(4)
52
Page 67
7IXE Motherboard
53
Loading...