Page 1
Phone/Fax No: (818) 854- 9338/ (818) 854-9339
hereby declare s that the product
FCC Compliance Statement:
DECLARATION OF CONFORMITY
Per FCC Part 2 Section 2. 1077(a)
This equipment has been tested and found to
comply with limits for a Class B digital device ,
Responsible Party Name: G.B.T. INC.
Address: 18305 Valley Blvd., Suite#A
LA Puent, CA 91744
pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable
protection against harmful interference in
residential installations. This equipment
generates, uses, and can radiate radio
Conforms to the following specifications:
FCC Part 15, Subpart B, Section 15.107(a) and Section 15.109(a),
Class B Digital Device
Supplementary Information:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful
and (2) this device must accept any inference received, including
that may cause undesired operation.
Representative Person's Name: ERIC LU
Eric Lu
frequency energy, and if not installed and used
in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause interference to radio or
television equipment reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna
-Move the equipment away from the receiver
-Plug the equipment into an outlet on a circuit different from that to which
the receiver is connected
You are cautioned that any change or modifications to the equipment not
expressly approve by the party respons ible for compliance could void Your
authority to operate such equipment.
This device complies with Part 15 of the FCC Rules. Operation is subjected to
the following two conditions 1) this device may not cause harmful interference
and 2) this device must accept any interference received, including interference
that may cause undesired operation.
-Consult the dealer or an experienced radio/television technician for
additional suggestions
Page 2
Declaration of Conformity
We, Manufacturer/Importer
(full address)
G.B.T. Technology Träding GMbH
Ausschlager Weg 41, 1F, 20537 Hamburg, Germany
( description of the apparatus, system, installation to which it refers)
(reference to the specification under which conformity is declared)
in accordance with 89/336 EEC-EMC Directive
EN 55011 Limits and methods of measurement EN 61000-3-2* Disturbances in supply systems caused
of radio disturbance characteristics of EN60555-2 by household appliances and similar
industrial, scientific and medical (ISM electr ical equipment “Harmonics”
high frequency equipment
EN55013 Limits and methods of measurement EN61000-3-3* Disturbances in supply systems caused
of radio disturbance characteristics of EN60555-3 by household appliances and similar
broadcast receivers and associated electrical equipment “Voltage fluctuations”
equipment
EN 55014 Limits and methods of measurement EN 50081-1 Generic emission standard Part 1:
of radio disturbance characteristics of Residual, commercial and light industry
household electrical appliances,
portable tools and similar electrical EN 50082-1 Generic immunity standard Part 1:
apparatus Residual, commercial and light industry
EN 55015 Limits and methods of measurement EN 55081-2 Generic emission standard Part 2:
of radio disturbance characteristics of Industrial environment
fluorescent lamps and luminaries
EN 55020 Immunity from radio interference of EN 55082-2 Generic immunity standard Part 2:
broadcast receivers and associated Industrial environment
equipment
EN 55022 Limits and methods of measurement ENV 55104 Immunity requirements for household
of radio disturbance characteristics of appliances tools and similar apparatus
information technology equipment
DIN VDE 0855 Cabled distribution systems; Equipment EN 50091- 2 EMC requirements for uninterruptible
part 10 for receiving and/or distribution from power systems (UPS)
part 12 sound and television signals
declare that the product
Mother Board
GA-6VX-4X
is in conformity with
CE marking (EC conformity marking)
The manufacturer also declares the conformity of above mentioned product
with the actual required safety standards in accordance with LVD 73/23 EEC
EN 60065 Safety requirements for mains operated EN 60950 Safety for information technology equipment
electronic and related apparatus for including electrical business equipment
household and similar general use
EN 60335 Safety of household and similar EN 50091-1 General and Safety requirements for
electrical appliances uninterruptible power systems (UPS)
Signature
Date : Dec. 01, 1999 Name : Rex Lin
(Stamp)
Manufacturer/Importer
:
Rex Lin
Page 3
6VX-4X
Pentium
II / III / Celeron
TM
處理器主機板
中文安裝手冊
Pentium II/III/Celeron TM處理器主機板
REV. 1.1 First Edition
R-11-01-000316C
Page 4
Page 5
使用手冊之組織架構
此安裝手冊是依下列章節組織而成 :
1) 版本修改摘要 使用手冊版本修改資訊
2) 清點附件 產品盒內附件清單
3) 特色摘要
4) 硬體設定
5) 效能測試和晶片組功能方塊 圖 主機板效能測試結果和晶片組功能
6) Suspend to RAM & Dual BIOS STR & Dual BIOS 安裝說明
7) BIOS 功能設定 BIOS 功能設定指南
8) 附錄 參考資料
主機板詳細資訊和規格
主機板安裝指南
方塊圖
Page 6
Page 7
目
錄
版本修改摘要
清點附件 P.2
特色彙總 P.3
6VX -4X 主機板的元件配置圖 P.5
插座及接腳設定的快速安裝指南 P.6
效能測試 P.27
晶片組功能方塊圖 P.2 8
安裝 Suspend to RAM 功能 P.29
雙 BIOS(Dual BIOS) 功能介紹 P.3 5
記憶體安裝指南 P.4 2
BIOS 功能設定目錄 P.43
附錄 P.73
P.1
Page 8
6VX-4X 主機板
版本修改摘要
版本 修改摘要 日期
1.1
6VX -4X 主機板中文安裝手冊首版發行。
Mar.2000
本手冊所有提及之商標與名稱皆屬該公司所有。
本手冊若有任何內容修改,恕不另行通知。
2000 年 03 月 16 日 台北,台灣
1
Page 9
清點附件
þ 6VX -4X 主機板一片
þ 軟、硬碟插座排線各一條
þ 主機板驅動程式光碟片 (TUCD)
o 內接式 COM B 接頭排線 (選購設備)
o 內接式 USB 接頭排線(選購設備)
o SCSI 裝置排線
þ 6VX -4X 中文使用手冊
清點附件
2
Page 10
6VX-4X 主機板
特色總彙
規格 Ÿ 主機板採四層設計 ATX 規格 30.6 公分 x 20.4 公分
CPU Ÿ Pentium II/III /Celeron 處理器
nd
晶片組
時脈產生器
Ÿ 2
Ÿ VT82C694X (VIA Apollo Pro 133A)
Ÿ VT82C686A
Ÿ ICS 9248AF-63/9279BF-01
Ÿ 支援 66/100/133 MHz system bus speeds (PCI 33MHz)
Ÿ 112/124/142/152 MHz system bus speeds
快取記憶體取決於 CPU
(PCI 44MHz) (reserved)
記憶體 Ÿ 4 支 168-pin DIMM 插槽支援 6 banks.
Ÿ 支援 PC-100 / PC-133 SDRAM and VCM SDRAM
Ÿ 支援 6 banks up to 1.5GB DRAM(256 MB DRAM)
Ÿ 支援 only 3.3V SDRAM DIMM
Ÿ 支援 72bit ECC type DRAM integrity mode.
I/O 控制器
Ÿ VT82C686A
擴充槽 Ÿ 1 AMR (Audio Modem Riser) 擴充槽
Ÿ 1 AGP Slot Supports 4X mode & AGP 2.0 compliant
Ÿ 5 個 32-bit 的 PCI Bus 擴充槽
Ÿ 1 個 16-bit 的 ISA Bus 擴充槽
內建 IDE Ÿ IDE 控制器內建在 VIA VT82C82686A PCI 晶片內,提供
PIO, Bus Master (Ultra DMA/33 及 ATA 66) 操作模式的
IDE HDD/CD-ROM
Ÿ 可連接四個 IDE 裝置
內建周邊設備 Ÿ 1 個軟碟插座支援兩台磁碟機
(360K ,720K ,1.2M ,1.44M 及 2.88M bytes )
Ÿ 1 個並列插座可支援 SPP/EPP/ECP 模式
Ÿ 2 個串列插座 (COM A & COM B)
Ÿ 4 個 USB 插座
Ÿ 1 個紅外線連接端(可連接 IR )
硬體監控 Ÿ CPU/電源供應器/系統風扇轉速偵測
Ÿ CPU 風扇控制
Ÿ 系統電壓自動偵測
PS/2 插座
Ÿ CPU 過熱警報器
Ÿ PS/2
鍵盤 連接埠及 PS/2 滑鼠連接埠
To be continued…
3
Page 11
BIOS Ÿ 使用經授權 AMI BIOS, 2M bit 快閃記憶體
Ÿ Support Dual BIOS
內建音效(選購設備)
附加特色 Ÿ 內接型/外接型數據機開機功能
Ÿ 內建 VIA sound (VIA VT82C686A)
Ÿ Aureal AU8810 sound (選購設備)
Ÿ 網路遠端開機功能
Ÿ 支援 AC back 電源管理模式
Ÿ USB 鍵盤/ 滑鼠 STR 開機功能
Ÿ STR 功能(Suspend-To-RAM)
特色總彙
4
Page 12
6VX-4X 主機板
6VX-4X 主機板的元件配置圖
JP15
USB
PS/2
JP16
JP5
LED1
ATX POWER
JP10
J9
COMB
COMA
J8
J7
LPT
GAME & AUDIO
AU8810
BACKUP
BIOS
MAIN
BIOS
J5
SW2
ISA
AMR
JP18
PCI1
PCI2
PCI3
PCI4
PCI5
JP8
JP7
JP11
VT82C694
CPU
JP6
DIMM3
DIMM2
DIMM1
DIMM4
FLOPPY JP1 USB2 J2
IDE2
IDE1
6VX-4X
BAT1
AGP
SW1
VT82C686A
J11
J1
J3
JP2
IR
5
Page 13
6VX-4X 主機板的元件配置圖
$
CPU 速度設定 / 插座及接腳設定的快速安裝指南
CPU 速度設定
插座
遊戲搖桿及音源插座
COM A 串列插座 / COM B 串列插座 / LPT 並列插座
USB 規格插座
PS/2 鍵盤及 PS/2 滑鼠插座
JP16 (CPU散熱風扇電源接腳)
JP15 (電源散熱風扇電源接腳)
JP2 (系統散熱風扇電源接腳)
ATX 電源插座
前面板 USB 2規格插座[選購設備 ]
IR (紅外線連接端 )
Floppy Port(軟碟插座)
第一組 IDE 1插座 / 第二組 IDE 2插座
J3 (Ring Power On) (內建數據機喚醒功能接腳)
J1 (Wake on LAN) (網路喚醒功能接腳)
J7 (TEL) (數據機內部發聲接腳)
J5 (AUX IN 接腳)
J8 (光碟機音源線接腳)
J9 (SPDIF接腳) (提供數位音效輸出到喇叭或供給AC杜比解碼器)
[選購設備 ]
JP5 (STR 指示燈連接腳 & DIMM LED)
J11 (外部 SMBUS 設備接腳)
接腳定義說明
J2 (2x11 pins 接腳)說明
JP1 (清除 CMOS 功能接腳)
JP18/JP7/JP8 (內建 AC97& AMR 選擇)
JP11 (STR 功能選擇接腳)
JP10 (內建音效卡功能選擇接腳) [選購設備]
Page
P.7
P.14
P.14
P.14
P.15
P.15
P.16
P.16
P.17
P.17
P.18
P.18
P.19
P.19
P.20
P.20
P.21
P.21
P.22
P.22
P.23
P.2 3
P.24
P.24
P.25
P.25
P.26
P.26
6
Page 14
6VX-4X 主機板
CPU 速度設定
您可以利用JP6 及DIP SWITCH (SW1)來調整系統外頻切換, 選擇 100MHz 及
133MHz 或Auto由 BIOS自動去偵測控制. 使用DIP SWITCHSW2 來調整CPU 的倍頻
數, 所支援CPU的頻率從 233 - 733MHz.
Set System Bus Speed
SW1: O : ON, X : OFF
CPU (MHz) PCI(MHz) JP6 1 2 3 4
66 33 1-2 X X O O
100 33 1-2 X X X X
112 37 1-2 O X X X
124 41 1-2 O O X X
133 33 N/C O O O X
142 35 N/C X O O X
152 38 N/C O X O X
M
請注意主機板上DIP SWITCH (SW1) 設定的倍頻及外頻,需要和CPU 的倍頻及
外頻相符合,否則易造成系統當機。
SW2:
FREQ. RATIO
X 3
X 3.5
X 4
X 4.5
X 5
X 5.5
X 6
X 6.5
X 7
X 7.5
X 8
X 8.5
X 9
X 9.5
1 2 3 4
O X O O
X X O O
O O X O
X O X O
O X X O
X X X O
O O O X
X O O X
O X O X
X X O X
O O X X
X O X X
O X X X
X X X X
DIP SWITCH
7
Page 15
F
For 133MHz Jumper Setting:
JP6
CPU JP6
66 /100MHz 1-2 (closed)
133 MHz N/C(open)
CPU 速度設定
ON 1
1 2 3 4
SW1
我們不建議您設定
¬
如果您要將系統速度設定為
設定
112 / 124 / 142 /150MHz,
, 例如;CPU,
顯示卡, 記憶體,硬碟來設定
112 / 124 / 142 /150MHz ,
因為那不屬於硬體標準規格範圍
1. Pentium II /CeleronTM 233 / 66 MHz FSB
ON
JP6
1 2 3 4
SW2
SW2
ON
1 2 3 4
SW1
1
.
請依據您的硬體規格
8
Page 16
6VX-4X 主機板
2. Pentium II /CeleronTM 266/66 MHz FSB
ON
ON
JP6
1
SW1
1 2 3 4
1 2 3 4
SW2
3. Pentium II /CeleronTM 300/66 MHz FSB
ON
SW1
ON
JP6
1 2 3 4
1 2 3 4
1
SW2
4. Pentium II /CeleronTM 333/66 MHz FSB
ON
SW1
ON
JP6
1 2 3 4
1 2 3 4
1
SW2
5. Pentium II /CeleronTM 366/66 MHz FSB
ON
ON
JP6
1 2 3 4
SW1
1 2 3 4
SW2
1
9
Page 17
6. Pentium II /CeleronTM 400/66 MHz FSB
ON
ON
JP6
CPU 速度設定
1
SW1
1 2 3 4
1 2 3 4
SW2
7. Pentium II /CeleronTM 433/66 MHz FSB
ON
SW1
ON
JP6
1 2 3 4
1 2 3 4
1
SW2
8. Pentium II 350/100 MHz FSB
ON
SW1
ON
JP6
1 2 3 4
1 2 3 4
1
SW2
9. Pentium II 400/100 MHz FSB
ON
ON
JP6
1 2 3 4
SW1
1 2 3 4
SW2
1
10
Page 18
6VX-4X 主機板
10. Pentium II /III 450/100 MHz FSB
ON
ON
JP6
1
SW1
1 2 3 4
1 2 3 4
SW2
11. Pentium II /III 500/100 MHz FSB
ON
SW1
ON
JP6
1 2 3 4
1 2 3 4
1
SW2
12. Pentium II /III 550/100 MHz FSB
ON
SW1
ON
JP6
1 2 3 4
1 2 3 4
1
SW2
13. Pentium II /III 600/100 MHz FSB
ON
ON
JP6
1 2 3 4
SW1
1 2 3 4
SW2
1
11
Page 19
14. Pentium II /III 650/100 MHz FSB
ON
ON
JP6
CPU 速度設定
1 2 3 4
SW1
1 2 3 4
SW2
15. Pentium® !!! 533/133 MHz FSB
ON
SW1
ON
1 2 3 4
1 2 3 4
SW2
16. Pentium® !!! 600/133 MHz FSB
ON
SW1
ON
1 2 3 4
1 2 3 4
SW2
17. Pentium® !!! 667/133 MHz FSB
ON
ON
1 2 3 4
1 2 3 4
1
JP6
1
JP6
1
JP6
1
SW1
SW2
12
Page 20
6VX-4X 主機板
18. Pentium® !!! 733/133 MHz FSB
ON
ON
JP6
SW1
1 2 3 4
1 2 3 4
SW2
1
13
Page 21
插座
遊戲搖桿及音源插座
插座及接腳設定的快速安裝指南
Game
Port
Line Out
MIC
Line In
COM A 串列插座 / COM B 串列插座 / LPT 並列插座
LPT Port
COM B COM A
14
Page 22
6VX-4X 主機板
USB 規格插座
PS/2 鍵盤及 PS/2 滑鼠插座
1 2 3 4
滑鼠
PS/2
6
4
2
PS/2 鍵盤
8 7 6 5
接腳 . 定義
1 USB V0
2 USB D03 USB D0+
4
接地線
5 USB V1
6 USB D17 USB D1+
8 接地線
1
滑鼠/鍵盤
PS/2
接腳
1
2
3
定義
資料訊號線
無作用
接地線
4 VCC(+5V)
5
6
時脈
無作用
15
Page 23
JP16: CPU散熱風扇電源接腳
JP15: 電源散熱風扇電源接腳
插座及接腳設定的快速安裝指南
1
接腳 定義
1 接地線
2 +12V
3 偵測訊號線
接腳 定義
1 接地線
2 +12V
3
16
無作用
Page 24
6VX-4X 主機板
JP2: 系統散熱風扇電源接腳
ATX 電源插座
1
接腳 定義
1 接地線
2 +12V
3 偵測訊號線
接腳
3,5,7,13,
15-17
1,2,11 3.3V
20 10
4,6,19,20 VCC
10 +12V
12 -12V
18 -5V
8 電源良好訊號
9 5V SB stand by+5V
1
14 PS-ON(Soft On/Off)
接地線
定義
17
Page 25
前面板 USB 2 規格插座
插座及接腳設定的快速安裝指南
IR : 紅外線連接端
4
5
1
8
接腳 定義
1 VCC(+5V)
2 無作用
3 IR data input
4 接地線
5 IR data output
接腳
定義
1 VCC
2 USB D03 USB D0+
4
接地線
5 VCC
6 USB D17 USB D1+
8 接地線
1
18
Page 26
6VX-4X 主機板
Floppy : 軟碟插座
Red Line
第一組 IDE 1 插座 / 第二組 IDE 2 插座
Red Line
IDE 1 IDE 2
19
Page 27
插座及接腳設定的快速安裝指南
J3 : Ring Power On (內建數據機喚醒功能接腳)
1
接腳 定義
1 訊號線
接地線
2
J1 : Wake on LAN(網路喚醒功能接腳 )
1
接腳 定義
1 +5VSB
2 接地線
3 訊號線
20
Page 28
6VX-4X 主機板
J7 : TEL: 數據機內部發聲接腳
J5: AUX IN 接腳
1
接腳 定義
1 Signal-In
2
3 接地線
4 Signal-Out
接地線
接腳 定義
1 AUX-L
2 接地線
3
接地線
4 AUX-R
21
Page 29
插座及接腳設定的快速安裝指南
J8 : CD Audio Line In( 光碟機音源線接腳)
接腳 定義
1 CD-L
2 接地線
3 接地線
4 CD-R
J9 : SPDIF 接腳(提供數位音效輸出到喇叭或供給AC杜比解碼
器) (選購設備)
1
接腳 定義
1 VCC
2 SPDIF OUT
3 接地線
22
Page 30
6VX-4X 主機板
JP5 : STR 指示燈接腳 & DIMM LED
J11:外部 SM BUS 設備接腳
STR 指示燈外部接腳
1
+
DIMM 指示燈
1
接腳 定義
1 SMB CLK
2 無作用
3 接地線
4 SMB DATA
5 +5V
23
Page 31
接腳定義說明
J2 : For 2X11 Pins 接腳說明
GN
HD
插座及接腳設定的快速安裝指南
1
1
GN : 省電模式開關
(Green Switch)
GD : 省電模式指示燈
(Green LED)
HD : 硬碟存取指示燈接頭
(IDE Hard Disk Active LED)
SPK : 內建蜂鳴器
(Speaker Connector)
RE : 重置開關接頭
(Reset Switch)
P+P− P− : 電源指示燈
(Power LED)
PW : 按鍵開 /關機
(Soft Power Connector)
1
PW P+ P− P−
GD
S P K
1
1
開路: 一般運作
短路: 進入省電模式
接腳 1: LED 燈號正極(+)
接腳 2: LED 燈號負極(−)
接腳 1: LED 燈號正極(+)
接腳 2: LED 燈號負極(−)
接腳 1: 電源線VCC(+)
接腳 2- 接腳 3: 無作用
接腳 4: 資料輸出線(−)
開路: 一般運作
短路: 強迫系統重新開機
接腳 1: LED 燈號正極(+)
接腳 2: LED 燈號負極(−)
接腳 2: LED 燈號負極(−)
開路: 一般運作
短路: 啟動電源開關
24
Page 32
6VX-4X 主機板
JP1 : 清除 CMOS 功能接腳
1
接腳 定義
1-2 短路 一般運作(預設值 )
2-3 短路 清除 CMOS
JP7/JP8/JP18 : 內建 AC97& AMR (Primary or Secondary ) 選擇
(AMRà Audio Modem Riser)
JP18
JP8
JP7
1
Jumper
定義
AC97
預設值
(
Only AMR
(Primary)
AC97+MR
(Secondary)
JP7 JP8 JP18
)
1-2
短路
3-4
短路
1-2
短路
1-2 短路
3-4 短路
1-2
短路
1-2
短路
開路
開路
短路
25
Page 33
插座及接腳設定的快速安裝指南
JP11: STR 功能選擇接腳
1
接腳 定義
短路 啟動 STR
開路 關閉 STR
(預設值)
JP10 : 內建音效卡功能選擇接腳(選購設備)
1
接腳
短路 開啟內建音效卡功能
1-2
(預設值)
短路 關閉內建音效卡功能
2-3
定義
26
Page 34
6VX-4X 主機板
效能測試
以下是 6VX-4X的測試數據,基本上這些測試數值僅供參考,因為不同的軟、硬體
配備都會影響測試結果,所以我們無法保證使用者自行測試的數據會與下列公佈
數值完全吻合。
• CPU
• 記憶體 (128MBx1) SDRAM (BUFFALO SEC KM48s8030CT-GA)
• 快取記憶體 CPU 內建 256 KB 快取記憶體
• 顯示介面卡 Gigabyte GA-660 Plus Rev1.4 (Driver 4.00.1381.0208.4.00)
• 儲存裝置 內建 IDE 插座(IBM DTTA -371800)
• 作業系統 Windows NT™ 4.0 SPK5
• 驅動程式 顯示卡驅動程式使用1024 x 768 x 16bit colors x 75Hz 解析
Pentium III 733MHz 處理器 (Coppermine)
度.
Processor
Intel Pentium III
733MHz(133x5.5)
Winbench99
CPU mark99 65.1
FPU Winmark 99 3920
Business Disk Winmark 99 4780
Hi-End Disk Winmark 99 10400
Business Graphics Winmark 99 351
Hi-End Graphics Winmark 99 659
Winstone99
Business Winstone99 39.9
Hi-End Winstone99 35.6
27
Page 35
晶片組功能方塊圖
AGP 2X/4X
晶片組功能方塊圖
14.318MHz
DIMM Sockets
33/ATA66
IDE Ports
AU8810
AGP Bus
ISA Bus
IDE Bus
VIA
VT82C694X
PCI Bus
VT82C686A
VIA
USB Bus
66 /100 /133 MHz
66 /100/133 MHz
ICS 9248AF-63
33 MHz
9279BF-01
33 MHz
14.318MHz
66 /100 /133 MHz
Shared
CODEC
PS/2 KB/Mouse
IR
USB Port
28
Page 36
6VX-4X 主機板
安裝 Suspend to RAM 功能
A.1 STR 功能簡介
STR 是一種 Windows 98 ACPI 下的暫停模式功能。 當恢復 STR 暫停模式,系統能夠
在幾秒鐘之內回復到進 STR(S3)之前的狀態, 這狀態是在系統進入暫停模式之前
就已經被存在記憶體內,當在 STR 暫停模式時,系統將會使用少量的能源去維持
STR 功能重要的資料,並支援各種不同模式的喚醒功能。
A.2 STR 功能安裝
請依照下列步驟來完成 STR 安裝
Step 1:
要使用 STR 功能, 系統必須在 Windows 98 ACPI 模式:
使用 Windows 98 光碟片安裝
A. 將 Windows 98 光碟片放入光碟機中, 選擇開始, 並執行。
B. 依 Window 規定鍵入 “D:\setup /p j”, 按下 enter 或雙擊滑鼠兩下。
『所有在 12/01/99 之後的 BIOS 版本,皆為 Windows98 ACPI Compatible BIOS.此時
只要鍵入"D:\Setup", 便會自動安裝系統為 ACPI mode. 』
C. 當安裝完成後,從光碟機中移除光碟片,並重新啟動您的系統。
(我們假設光碟機的代號為 D:)
29
Page 37
安裝 Suspend to RAM
STEP 2:
當使用
功能之前,您需要設定主機板上的
STR
短路,如下圖所示
JP11
1
接腳 定義
短路 啟動 STR
開路 關閉 STR
(預設值)
STEP 3:
當系統開機開始計算記憶體時, 按下<Del>。您將會進入 BIOS 設定畫面,選
擇”POWER MANAGEMENT SETUP ”,並選”ACPI Sleep Type: S3/STR ”。請務必記得要按
下”ESC”並選擇”SAVE & EXIT SETUP ”來儲存設定。
恭喜您!!您已經順利的完成了 STR 的功能安裝。
:
30
Page 38
6VX-4X 主機板
A.3 如何讓您的系統進入 STR 模式 ?
有兩種方式來完成:
1.選擇”關閉 Windows”中的” 暫停” 選項
A. 在 Windows98 功能列選擇”開始”並選”關機”
B. 選擇”暫停”並按下”確定”。
31
Page 39
2. 定義系統開機時是在 STR 模式中:
A. 用滑鼠雙擊”我的電腦”中的”控制台” 。
B. 用滑鼠雙擊”電源管理”選項。
安裝 Suspend to RAM
32
Page 40
6VX-4X 主機板
C. 選擇”進階”並選”等候使用”模式.
STEP 4 :
在完成設定後重新啟動你的系統.當您想要進入 STR 省電模式時,只要按下”電源開
關”按鈕即可。
A.4 如何恢復到 STR 省電模式 ?
有 5 種方式可”喚醒”系統:
1. 按下”電源開關”按鈕。
2. 使用”滑鼠開機”功能。
3. 使用”定時開機”功能。
4. 使用”數據機開機”功能。
5. 使用”網路卡開機”功能。
33
Page 41
安裝 Suspend to RAM
A.5 注意事項:
1.為了要使用正確的 STR 功能 ,一些硬體及軟體的需求是必須符合的 :
A. 您的 ATX 電源供應器必須要是 ATX 2.01 的規格(5V Stand-By 電流供應須超過
720 毫安培 )
B. SDRAM 必須是符合 PC-100 規格.
2. JP5 是 STR 指示燈的連接頭.當系統進入 STR 省電模式時,STR 指示燈將會亮起.
STR 指示燈外部接腳
1
+
DIMM 指示燈
34
Page 42
6VX-4X 主機板
American Release:11/15/99
雙 BIOS(Dual BIOS)功能介紹
A. 何謂雙 BIOS (Dual BIOS)?
主機板上有兩顆 BIOS,分別為 ”主要 BIOS(Main BIOS)” 及”備份 BIOS (Backup
BIOS)”。在一般的正常狀態下,系統是由主要BIOS在運作 ,若您的系統主
要BIOS損壞時 ,則備份BIOS將會接管開機的動作並自動修復主要BIOS,
此時您的系統就可以像以往一樣正常的工作。
B. 雙BIOS功能及使用方法
a.開機畫面
Megatrends AMIBIOS (C) 1999 American Megatrends
xxx xxx
Check System Health ok ,
CPU ID:0681 Patch ID:0001
Pentium III CPU - 700MHz
Check NVRAM…
Wait…
Press F1 to enter Dual BIOS Utility.
( C ) Americ an Megatrends Inc.,
62-0902-000000-00101111-071595-V694V686-1V133000-F
Press F1 to enter Dual BIOS Utility
35
Page 43
b. AMI Dual BIOS Flash ROM程式畫面
AMI Dual BIOS Flash ROM Programming Utility
Boot From……………………….. Main BIOS
Main ROM Type………………… SST 39SF020
Wide Range Protection Disable
Boot From Main BIOS
Auto Recovery Enable
Halt On Error Disable
Copy Main ROM Data to Backup
Load Default Settings
Save Settings to CMOS
PgDn/PgUp:Modify(Enter:Run) ↑↓ :Move ESC:Reset F10:Power Off
c. Dual BIOS 程式選項說明
BIOS will auto detect:
Boot From : Main BIOS
Main ROM Type : SST 39SF020
Backup ROM Type : SST 39SF020
Wide Range Protection: Disabled (預設值 ), Enabled
狀況 1:
當主要 BIOS 在電源開啟之後,作業系統載入前,若有 Failure 狀況(例
如 :Update ESCD Failure, Checksum Error 或 Reset), 此時 Wide Range
Protection 若設為 Enabled,會自動切換到備份 BIOS 來完成開機動作。
狀況 2:
周邊卡(例如:SCSI 卡,網路卡 …)上若有 ROM BIOS,並進其 BIOS 內做任何
的設定, 設定完畢後,此時若由周邊卡的 ROM BIOS 發出訊號要求系統重
開機,則不會由備份 BIOS 來開機。
但若是使用者自行按電腦機殼面版重開機按鈕,則會由備份BIOS 來開機。
雙BIOS 功能介紹
SST 39SF020
36
Page 44
6VX-4X 主機板
Boot From : Main BIOS (預設值) , Backup BIOS
狀況 1:
使用者可自行設定開機要由主要 BIOS 或是備份 BIOS 來開機。
狀況 2:
主要 BIOS 或備份 BIOS 其中一顆 BIOS 損壞,此項設定會變灰,使用者也無法更改
設定。
Auto Recovery : Enabled (預設值) , Disabled
主要 BIOS 或備份 BIOS 其中一顆 Checksum Failure 時, 正常的 BIOS 會自動修復
Checksum Failure 的 BIOS。
{在 BIOS 設定中的 Power Management Setup 內 , ACPI Suspend Type 選項若選
Suspend to RAM,此時 Auto Recovery 會自動設定為 Enabled。}
(假如您要進入BIOS組態設定, 請在開機畫面出現時按下“Del” 鍵)
Halt On BIOS Defects : Disabled (預設值 ), Enabled
當 Halt On BIOS Defects 設為 Enabled 時 ,若 CHECKSUM ERROR 或 MAIN BIOS
IS WIDE RANGE PROTECTION ERROR, 則開機時會出現以下訊息;並使系統暫
停,等待使用者按鍵做進一步處理:
若 Auto Recovery :Disabled 會顯示<or the other key to continue.>
若 Auto Recovery : Enabled 會顯示<or the other key to Auto Recover.>
Copy Main ROM Data to Backup
自動修復動作提示:
Are you sure to copy BIOS?
[Enter] to continue or [Esc] to abort …
這個動作表示Main BIOS能正常開機並會自動修復 Backup BIOS .或者表示
Backup BIOS能正常開機並會自動修復 Main BIOS .
(此修復程式為系統自動設定,使用者無法變更。)
37
Page 45
雙 BIOS功能介紹
DualBIOS
主機板的新革命
首創雙 BIOS 主機板新紀元
您的主機板 BIOS 是否曾經因昇級失敗或中毒,而導致整台電腦故障,送
修後又得忍受沒有電腦可用的煎熬?
TM
技嘉科技獨創全球第一片 DualBIOS
免除上述的煩惱。這項新技術在第一顆 BIOS 的資料遺失或損毀時,會自
動啟用第二顆 BIOS 繼續完成開機的動作,並可以修復第一顆 BIOS 。
手機用雙頻、車子開雙 B 不稀奇,使用技嘉科技 DualBIOS TM (雙 BIOS)主機
板才是最高檔的選擇!
在此技嘉科技為您隆重介紹 DualBIOSTM (雙 BIOS)技術,它是一個在系統內
隨時可被使用的 BIOS。技嘉科技特別為您提供了這項物超所值的功能,並
在未來將會在技嘉科技的所有主機板上提供此功能。
TM
技術問答集
(主機板內建雙BIOS)的新技術,讓您
38
Page 46
6VX-4X 主機板
問答集
TM
問 I. 什麼是 DualBIOS
科技?
答:
TM
DualBIOS
是由技嘉科技已申請專利的一項技術, 主機板上有兩顆 BIOS,
分別為”主要 BIOS(Main BIOS)”及”備份 BIOS (Backup BIOS)”。
若您的主要BIOS 損毀,備份 BIOS將會自動取代主要的BIOS並在下次啟動
電腦時將會接管開機的動作並自動修復主要 BIOS。這個動作可說是全自
動的並不會有任何遲緩,不管問題是由於燒錄 BIOS 時失敗或中毒或其他
原因導致您的主要 BIOS 故障,備份 BIOS 將會全自動為您處理。
TM
問 II. 為什麼主機板上需要 DualBIOS
答:
?
在今天電腦系統愈來愈多的問題是由於 BIOS故障而引起電腦不開機,一般
最常見是中毒,或 BIOS 升級時失敗,及 BIOS 本身晶片損毀..等問題。
1. 現已發現愈來愈多的病毒會攻擊並損壞您的系統 BIOS, 它們會導致您
的系統不穩或甚至不開機的情況發生。
2 BIOS 內的資料可能損毀的情況有:系統突然斷電或使用者將系統不正常
的重新開機,或是使用者在升級當中突然斷電。
3. 若使用者升級到錯誤的 BIOS 版本,也可能導致系統無法正常開機或開機
後系統當機。
4.一個 BIOS 的生命週期根據電子特性原理是有限的。
現在一般的電腦幾乎都是隨插即用的 BIOS, 若使用者經常更換周邊裝置
配備,可能也會損毀 BIOS,不過這機率較小。
當您使用技嘉科技申請的專利技術,可減少由於上述原因而導致BIOS資料
損毀及系統開機時的當機情形。另外, 此項專利技術也可為您省下一筆因
BIOS 而導致的維修經費及時間。
39
Page 47
雙BIOS 功能介紹
問 III. DualBIOS
TM
科技如何運作?
答:
TM
1. DualBIOS
科技提供開機期間完整的保護 ,範圍從 POST (Power On Self
Test), ESCD Update,到自動偵測 PnP 周邊。
TM
2. DualBIOS
科技提供 BIOS 自動回復的功能,當開機時主要 BIOS 沒有完
成開機動作或 BIOS Checksum 錯誤發生時,仍可以正常進入系統。在 Dual
BIOS 程式中,”Auto Recovery”的選項將確保主要 BIOS 或備份 BIOS 其中一
個損壞時, Dual BIOSTM科技將會自動使用正常的 BIOS 開機並修復有問題
的 BIOS。
TM
3. Dual BIOS
提供手動修復的功能,並有一個內建 BIOS 更新程式,可將系
統內正常 BIOS 內的資料燒錄到有問題的 BIOS 內,而不需要執行其他的
BIOS 燒錄程式。
TM
4. Dual BIOS
提供單向修復的功能,這項功能將確保有問題的 BIOS 不會
被誤認為正常的 BIOS, 而導致正常的 BIOS 被誤燒錄。
問 IV. 誰需要 DualBIOS
TM
科技?
答:
1. 因為現今病毒氾濫,所以每個人的主機板上都應有 Dual BIOSTM。目前
每天都有新的,具攻擊性的 BIOS 病毒產生,而現今一般市面所售出的產
TM
品都無法針對對 BIOS 有攻擊性病毒有所保護, DualBIOS
科技將提供
您的電腦一個最先進的解決方法:
案例> 兇惡的病毒可能導致您的 BIOS 損毀,在傳統單顆 BIOS 主機板
上 ,這部電腦直到維修回來之前都無法使用。
解決方案1> 若”Auto Recovery”有開啟的話,當電腦中毒時,備份的 BIOS
將會自動接管開機的動作並自動修復有問題的 BIOS 。
解決方案 2> 若主要 BIOS 損毀,使用者也可以進入 Dual BIOS 程式中,
自行選擇由備份 BIOS 來開機。
2. 當 BIOS 完成更新後,若 DualBIOSTM偵測到主要 BIOS 有問題,備份 BIOS
將自動接管開機動作,同時也進行主要 BIOS 及備份 BIOS 的 Checksum
之確認來確保 BIOS 能正常運作。
40
Page 48
6VX-4X 主機板
3. 電腦玩家們可在同一塊主機板上,同時擁有 2個不同版本的 BIOS,方便
玩家們來調整系統的效能或穩定性。
4. 針對於高階的桌上型電腦及工作站伺服器, Dual BIOSTM也提供了更具
彈性的進階功能。在 Dual BIOSTM程式內,若開啟”Halt On When BIOS
Defects”的選項,則當主要 BIOS 資料損毀時,系統會暫停並出現警告訊
息。但大部份工作站伺服器都需要不斷工作,在這種情況下, 可關
閉 ”Halt On When BIOS Defects” 選項,以免造成電腦無法進入作業系
統。另一個 Dual BIOSTM的優點為:若將來有需要更大的 BIOS儲存空間,
您可以從 2個 2Mbit BIOS升級到 2個 4Mbit的 BIOS。
41
Page 49
記憶體安裝指南
記憶體安裝指南
6VX-4X主機板有4個(DIMM)擴充槽. BIOS 會自動偵測記憶體的規格及其大小. 安裝
記憶體只需將DIMM插入其插槽內即可, 由於記憶體模組有兩個凹痕, 所以只能以
一個方向插入,在不同的插槽,記憶體大小可以不同.
記憶體安裝組合如下表:
Location 168-pin SDRAM DIMM Modules 備註
DIMM1
(Bank 0,1)
(Bank 2,3)
DIMM3
(Bank 4,5)
DIMM4
(Bank 4,5)
最大支援記憶體:1.5GB
★支援 16 / 32 / 64 / 128 / 256 / 512 MB SDRAM DIMM Modules .
Single – Sided
Double – Sided
Single – Sided DIMM2
Double – Sided
Single – Sided
Double – Sided DIMM4 must be empty
Single – Sided
Double – Sided DIMM3 must be empty
DIMM4 have only single-sided
DIMM3 have only single-sided
42
Page 50
6VX-4X 主機板
$ BIOS 組態設定目錄
主畫面功能
標準CMOS設定
BIOS功能設定
晶片組的特性設定
省電功能設定
隨插即用與 PCI組態設定
載入 BIOS 預設值
載入 Setup 預設值
整合週邊設定
硬體偵測設定
設定管理者(Supervisor)/使用者(User)密碼
自動偵測 IDE 硬碟
離開 SETUP 並儲存設定結果
離開 SETUP 但不儲存設定結果
Page
P.4 5
P.48
P.51
P.53
P.56
P.59
P.61
P.62
P.63
P.67
P.69
P.70
P.71
P.72
43
Page 51
BIOS設定
BIOS 組態設定
基本上主機板所附 AMI BIOS 便包含了CMOS SETUP 程式,以供使用者自行依照需
求,設定不同的數據,使電腦正常工作,或執行特定的功能.
CMOS SETUP 會將各項數據儲存於主機板上內建的CMOS RAM 中,當電源關閉時,
則由主機板上的鋰電池繼續供應 CMOS RAM 所需電力。
當電源開啟之後,BIOS 開始進行 POST(Power On Self Test 開機自我測試)時,按
下<Del >鍵便可進入 AMI BIOS 的 CMOS SETUP 主畫面中。
如果您來不及在POST過程中按下<Del >鍵順利進CMOS SETUP ,那麼可以補按<
Ctrl>+< Alt>+< Del>暖開機或按下機殼上的 Reset按鈕,以重新開機再次進
POST程序,再按下<Del>鍵進入CMOS SETUP程式中。
操作按鍵說明
á(向上鍵) 移到上一個項目
â(向下鍵) 移到下一個項目
ß(向左鍵) 移到左邊的項目
à(向右鍵) 移到右邊的項目
Esc 鍵 回到主畫面,或從主畫面中結束 SETUP 程式
Page Up鍵 改變設定狀態,或增加欄位中之數值內容
Page Down鍵 改變設定狀態,或減少欄位中之數值內容
F1 功能鍵 可顯示目前設定項目的相關說明
F2 功能鍵 功能保留
F3 功能鍵 功能保留
F4 功能鍵 功能保留
F5 功能鍵 可載入該畫面原先所有項目設定(但不適用主畫面)
F6 功能鍵 可載入該畫面之 BIOS 預設設定(但不適用主畫面)
F7 功能鍵 可載入該畫面之 SETUP 預設設定(但不適用主畫面)
F8 功能鍵 功能保留
F9 功能鍵 功能保留
F10 功能鍵 儲存設定並離開 CMOS SETUP 程式
如何使用輔助說明
主畫面的輔助說明
當您在 SETUP 主畫面時,隨著選項的移動,底下便跟著顯示︰目前被選到的
SETUP 項目的主要設定內容。
44
Page 52
6VX-4X 主機板
設定畫面的輔助說明
當您在設定各個欄位的內容時,只要按下<F1 >,便可得到該欄位的設定預
設值及所有可以的設定值,如BIOS 預設值或CMOS SETUP 預設值,若欲跳離輔
助說明視窗,只須按<Esc> 鍵即可。
主畫面功能
當您進入CMOS SETUP設定畫面時,便可看到如下之主畫面,從主畫面中可以讓你
選擇各種不同之設定選單,你可以用上下左右鍵來選擇你要設定之選項並按Enter
進入子選單。
AMIBIOS SIMPLE SETUP UTILITY -VERSION 1.20
( C ) 1999 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP HARDWARE MONITOR SETUP
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓←→ : Select Item (Shift) F2 : Change Color F5 : Old Values
F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
Time, Date, Hard Disk Type, …
圖 1: 主畫面功能
• Standard CMOS setup (標準 CMOS 設定 )
設定日期、時間、軟硬碟規格、及顯示器種類。
• BIOS features setup (BIOS 功能設定)
設定 BIOS 提供的特殊功能,例如病毒警告、開機磁碟優先程序、磁碟代號交
換....等。
45
Page 53
• Chipset features setup ( 晶片組特性設定 )
設定主機板採用的晶片組相關運作參數,例如 「 DRAM Timing 」、「 ISA Clock 」 ....
等。
• Power management setup ( 省電功能設定 )
設定 CPU 、硬碟、 GREEN 螢幕等裝置的省電功能運作方式。
• PNP/ PCI configuration ( 即插即用與 PCI 組態設定 )
設定 ISA 之 P n P 即插即用介面以及 PCI 介面的相關參數。
• Load BIOS defaults ( 載入 BIOS 預設值 )
執行此功能可載入 BIOS 的 CMOS 設定預設值,此設定是比較保守,但較能進
入開機狀態的設定值。
• Load Setup defaults ( 載入 Setup 預設值 )
執行此功能可載入 Setup 的 CMOS 設定預設值,此設定是較能發揮主機板速
度的設定。
• Integrated peripherals ( 內建整合週邊設定 )
在此設定畫面包括所有週邊設備的的設定 。 如 COM Port 使用的 IRQ 位 址,
LPT Port 使用的模式 SPP 、 EPP 或 ECP 以及 IDE 介面使用何種 PIO Mode 等裝
置之設定。
BIOS 設定
• Hardware Monitor Setup ( )
自動偵測風扇及系統溫度功能。
• Supervisor password ( )
設定一個密碼,並適用於進入系統或進入 SETUP 修改 CMOS 設定。
• User password ( )
設定一個密碼,並適用於開機使用 PC 及進入 BIOS 修改設定 。
• IDE HDD auto detection (自動偵測 IDE 硬碟 )
自動偵測 IDE 的參數設定,並可選擇寫入 CMOS (記得要存檔)。
46
Page 54
6VX-4X 主機板
• Save & exit setup (儲存並結束)
儲存所有設定結果並離開 SETUP 程式,此時 BIOS 會重新開機,以便使用新
的設定值,按<F10 >亦可執行本選項。
• Exit without saving (離開 CMOS 不儲存設定 )
不儲存修改結果,保持舊有設定並重新開機,按<ESC>亦可直接執行本選項。
47
Page 55
BIOS 設定
標準 CMOS 設定
在STANDARD CMOS SETUP 中,主要是為了設定IDE 硬碟的種類,以順利開機,除
此之外,還有日期、時間、軟碟規格、及顯示卡的種類可以設定.
AMIBIOS SETUP – STANDARD CMOS SETUP
( C ) 1999 American Megatrends, Inc. All Rights Reserved
Date (mm/dd/yyyy) : Tue Feb 15, 2000
Time (hh/mm/ss) : 10:36:24
Pri Master : Auto
Pri Slave : Auto
Sec Master : Auto
Sec Slave : Auto
Floppy Drive A: 1.44 MB 3 ½
Floppy Drive B: Not Installed
Boot Sector Virus Protection : Disabled
Month: Jan – Dec ESC : Exit
Day: 01 – 31 ↑↓ : Select Item
Year: 1990– 2099 PU/PD/+/– : Modify
(Shift)F2 : Color
TYPE SIZE CYLS HEAD PRECOMP LANDZ SECTOR MODE
Base Memory : 640 Kb
Other Memory : 384 Kb
Extended Memory: 127Mb
Total Memory : 128Mb
圖 2: 標準 CMOS 設定
• Date(mm:dd:yy) (日期設定)
即設定電腦中的日期,格式為「星期,月/ 日/ 年」,各欄位設定範圍如下表示:
Week
Month
Day
Year
由目前設定的「月/日/年」自萬年曆公式推算出今天為星期幾,
此欄位無法自行修改
1到12月
1到28/29/30/31
日,視月份而定
2000到2099年
• Time(hh:mm:ss) (時間設定)
即設定電腦中的時間是以 24 小時為計算單位,格式為「時:分:秒」舉例而
言,下午一點表示方式為 13 : 00 : 00 。當電腦關機後,RTC 功能會繼續執行,
並由主機板的電池供應所需電力。
48
Page 56
6VX-4X 主機板
• Primary HDDs / Secondary HDDs (第一組硬碟/ 第二組硬碟參數設定 )
設定第一、二組 IDE 硬碟參數規格,設定方式有兩種,建議的是設定方式是
採方式 1 ,但經常更換IDE 硬碟的使用者則可採方式 2 ,省去每次換硬碟都要
重新設定 CMOS 的麻煩。
方式 1:設成 User TYPE,自行輸入下列相關參數,即 CYLS、HEADS、SECTORS、
MODE ,以便順利使用硬碟。
方式2 :設定AUTO ,將TYPE 及MODE 皆設定AUTO ,讓BIOS 在POST過程中,自
動測試IDE 裝置的各項參數直接採用。
CYLS. Number of cylinders.(磁柱的數量 )
HEADS number of heads.(磁頭的數量 )
PRECOMP write precomp.
LANDZONE Landing zone.
SECTORS number of sectors(磁區的數量 ).
如果沒有裝設硬碟,請選擇 ”NONE” 後按 <Enter>
• Floppy Drive A / Floppy Drive B
可設定的項目如下表示:
None 沒有安裝磁碟機 .
360K, 5.25 in.
1.2M, 5.25 in.
720K, 3.5 in.
1.44M, 3.5 in.
2.88M, 3.5 in.
吋磁碟機,
5.25
吋磁碟機,
5.25
吋半磁碟機,
3
吋半磁碟機,
3
吋半磁碟機,
3
360KB
1.2MB
720KB
1.44MB
2.88MB
容量
容量
容量
容量
容量
.
.
.
.
.
• Boot Sector Virus Protection (病毒警告)
Enabled
Disabled
啟動此功能,當硬碟的啟動磁區或分割區被改寫時,會發出
警告訊息,由使用者決定是否要被寫入
不啟動此功能.(預設值
.
)
49
Page 57
• Memory ( 記憶體容量顯示)
目前主機板所安裝的記憶體皆由 BIOS 之POST(Power On Self Test) 自動偵測,
並顯示於 STANDARD CMOS SETUP 右下方。
Base Memory :傳統記憶體容量
PC 一般會保留 640KB容量做為 MS-DOS 作業系統的記憶體使用空間。
Extended Memory :延伸記憶體容量
可做為延伸記憶體的容量有多少,一般是總安裝容量扣除掉 Base
及 Other Memory 之後的容量,如果數值不對,可能是有 Module 沒安
裝好,請仔細檢查。
Other Memory :其它記憶體容量
通常是指 BIOS 從記憶體容量中,取 384KB 容量,做為 BIOS Shadow
功能的用途(Shadow RAM)。主要是在開機時,BIOS 將一些裝置的驅
動程式 Copy 到 DRAM 上面,使 BIOS 的執行速度提昇,有助 PC 整體
的效益。
BIOS 設定
50
Page 58
6VX-4X 主機板
BIOS功能設定
AMIBIOS SETUP – BIOS FEATURES CMOS SETUP
( C ) 1999 American Megatrends, Inc. All Rights Reserved
1st Boot Device :Floppy
2nd Boot Device :IDE-0
3rd Boot Device :CDROM
S.M.A.R.T for Hard Disks :Disabled
BootUp Num -Lock :On
Floppy Drive Seek :Disabled
Password Check :Setup
Proecssor Serial Number :Disabled
ESC : Quit
F1 : Help PU/PD/+/ - : Modify
F5 : Old Values (Shift)F2 :Color
F6 : Load BIOS Defaults
F7 : Load Setup Defaults
圖 3: BIOS 功能設定
• 1st
/ 2nd / 3rd Boot Device (第一/二/三次開機裝置)
Floppy 由軟碟機為第一次優先的開機裝置 .
LS-120/ZIP A: 由 LS-120/ZIP A:為第一次優先的開機裝置 .
IDE-0~IDE3 由硬碟機為第一次優先的開機裝置.
SCSI 由 SCSI 裝置為第一次優先的開機裝置 .
CDROM 由光碟機為第一次優先的開機裝置 .
Disabled 關閉此功能 .
NET WORK 由網路卡為第一次優先的開機裝置.
ATAPI ZIP C:
由 ATAPI ZIP C:為第一次優先的開機裝置
↑↓←→: Select Item
• S.M.A.R.T. Hard Disks (硬碟自我檢測功能)
Enabled 啟動硬碟 S.M.A.R.T. 的功能 .
Disabled 關閉硬碟 S.M.A.R.T. 的功能 .(預設值)
• Boot Up Num-Lock (起始時數字鍵鎖定狀態)
On
Off
開機後將數字區設成數字鍵功能.(預設值
開機後將數字區設成方向鍵功能
51
)
.
Page 59
• Floppy Drive Seek (開機時測試軟碟)
設定在 PC 開機時,POST 程式需不需要對 FLOPPY 做一次 SEEK 測試。可設
定的項目為:
Enabled
Disabled
要對
Floppy做Seek
不必對
Floppy做Seek
測試
測試
.
預設值
. (
)
• Password Check (檢查密碼方式)
BIOS 設定
Always
Setup
無論是開機或進入
只有在進入
CMOS SETUP
CMOS SETUP
均要輸入密碼
時才要求輸入密碼.(預設值
.
)
M 欲取消密碼之設定時,只要於 SETUP 內重新設定密碼時,不要按任何鍵,直
接按<Enter >使密碼成為空白,即可取消密碼的設定。
• Processor Serial Number (只支援 Pentium
Disabled 關閉 Processor Serial Number. (預設值)
Enabled 啟動 Processor Serial Number.
®
!!!處理器)
52
Page 60
6VX-4X 主機板
晶片組的特性設定
AMIBIOS SETUP –CHIPSET FEATURE CMOS SETUP
( C ) 1999 American Megatrends, Inc. All Rights Reserved
*** DRAM Timing ***
Top Performance :Disabled
SDRAM Timing by SPD :Disabled
SDRAM CAS# Latency :3
DRAM Frequency :Auto
C2P Concurrency & Master :Enabled
DRAM Integrity Mode :Disabled
AGP Mode :4X
AGP Comp. Driving :Auto
Manual AGP Comp. Driving :CB
AGP Aperture Size :64MB
USB Controller :All USB Port
USB Legacy Support :Disabled
F1 : Help PU/PD/+/ - : Modify
F5 : Old Va lues (Shift)F2 :Color
F6 : Load BIOS Defaults
F7 : Load Setup Defaults
ESC : Quit ↑↓←→ : Select Item
圖 4: 晶片組的特性設定
• Top Performance (最高效能)
Disabled 關閉此功能. (預設值)
Enabled 開啟 Top Performance功能 .
• SDRAM Timing by SPD
Disabled 關閉此功能 . (預設值 )
Enabled 開啟 SDRAM Timing by SPD功能 .
• SDRAM CAS# Latency (SDRAM CAS 延遲時間)
3 使用較慢 SDRAM DIMM module. (預設值)
2 使用較快 SDRAM DIMM module.
• DRAM Frequency
Auto 將此功能設定為 Auto. (預設值)
100MHz 設定 DRAM Frequency 為 100MHz.
66MHz 設定 DRAM Frequency 為 66MHz.
133MHz 設定 DRAM Frequency 為 133MHz.
53
Page 61
• C2P Concurrency & Master
Enabled 開啟 C2P Concurrency & Master 功能. (預設值)
Disabled 關閉此功能 .
• DRAM Integrity Mode
ECC 支援 72 位元 ECC 類型 DIMM 模組 .
Disabled 一般狀態 . (預設值)
• AGP Mode (AGP 模式)
4X 設定 AGP 模式為 4X. (預設值 )
1X 設定 AGP 模式為 1X.
2X 設定 AGP 模式為 2X.
• AGP Comp. Driving
Auto 設定 AGP Comp. Driving 為 Auto. (預設值)
Manual 設定 AGP Comp. Driving 為 Manual.
如果將 AGP Comp. Driving 設定為 Manual.
Manual AGP Comp. Driving : 00~FF
• AGP Aperture Size
BIOS 設定
4MB 設定 AGP Aperture Size 為 4MB.
8MB 設定 AGP Aperture Size為 8 MB.
16MB 設定 AGP Aperture Size為 16 MB.
32MB 設定 AGP Aperture Size為 32 MB.
64MB 設定 AGP Aperture Size為 64 MB. (預設值)
128MB 設定 AGP Aperture Size為 128 MB.
256MB 設定 AGP Aperture Size為 256 MB.
• USB Controller (通用序列匯流排功能)
Disabled 不啟動 USB 功能 .
USB Port 0&1
USB Port 2&3
All USB Port
啟動 USB Port 0 & 1.
啟動 USB Port 2 & 3.
啟動所有 USB Port. (預設值)
54
Page 62
6VX-4X 主機板
• USB Legacy Support
當啟動 USB 功能,USB 的支援形態將可被設定.
Keyboard 支援 USB 鍵盤 .
Keyb+Mouse 支援 USB 鍵盤和 USB 滑鼠.
Disabled
關閉此功能 . (預設值 )
55
Page 63
省電功能設定
AMIBIOS SETUP –POWER MANAGEMENT SETUP
( C ) 1999 American Megatrends, Inc. All Rights Reserved
ACPI Sleep Type :S1/POS RTC Alarm Power On :Disabled
Video Power Down Mode :Stand By RTC Alarm Date :15
Hard Disk Power Down Mode :Stand By RTC Alarm Hour :12
Suspend Time Out(Minute) :Disabled RTC Alarm Minute :30
Display Activity :Ignore RTC Alarm Second :30
IRQ3 :Monitor
IRQ 4 :Monitor
IRQ 5 :Ignore
IRQ 7 :Monitor
IRQ 9 :Ignore
IRQ 10 :Ignore
IRQ 11 :Ignore
IRQ 13 :Ignore
IRQ 14 :Monitor
IRQ 15 :Ignore
Soft-off by Power Button :Instant off
AC Back Function :Last state F1 : Help PU/PD/+/- : Modify
Modem Use IRQ :4 F5 : Old Values (Shift)F2 :Color
Modem Ring On/Wake On Lan :Enabled F6 : Load BIOS Defaults
PME Event Wake up :Enabled F7 : Load Setup Defaults
ESC : Quit ↑↓←→ : Select Item
圖 5: 省電功能設定
• ACPI Sleep Type
S1/POS 設定 ACPI Sleep type 為 S1. (預設值)
S3/STR 設定 ACPI Sleep type 為 S3.
BIOS 設定
• Video Power Down Mode
Disabled 不使用此功能 .
Suspend 設定螢幕關閉時 ,會進入 Suspend 省電模式 .
Stand By 設定螢幕關閉時,會進入 Stand By 省電模式 . (預設值)
• Hard Disk Power Down Mode (硬碟電源關閉模式)
Disabled 不使用此功能 .
Suspend 設定硬碟關閉時 ,會進入 Suspend 省電模式 .
Stand By 設定硬碟關閉時 ,會進入 Stand By 省電模式 . (預設值 )
56
Page 64
6VX-4X 主機板
• Suspend Time Out (Minute)
Disabled 不設定此功能 . (預設值)
1 設定電腦離線 1 分鐘後進入 Suspend 省電模式 .
2 設定電腦離線 2 分鐘後進入 Suspend 省電模式 .
4 設定電腦離線 4 分鐘後進入 Suspend 省電模式 .
8 設定電腦離線 8 分鐘後進入 Suspend 省電模式 .
10 設定電腦離線 10 分鐘後進入 Suspend 省電模式 .
20 設定電腦離線 20 分鐘後進入 Suspend 省電模式 .
30 設定電腦離線 30 分鐘後進入 Suspend 省電模式 .
40 設定電腦離線 40 分鐘後進入 Suspend 省電模式 .
50 設定電腦離線 50 分鐘後進入 Suspend 省電模式 .
60 設定電腦離線 60 分鐘後進入 Suspend 省電模式 .
• Display Activity
Ignore 忽略螢幕監控功能. (預設值 )
Monitor 啟動螢幕監控功能 .
• IRQ 3~IRQ15
Ignore 忽略 IRQ3 ~IRQ15.
Monitor 監控 IRQ3~IRQ15.
• Soft-off by Power Button (關機方式)
Instant-off 按一下 Soft-Off 開關便直接關機 . (預設值)
Delay 4 Sec. 須按住 Soft-Off 開關 4 秒後 才關機.
• AC Back Function (斷電後,電源回復時的系統狀態 )
Last State 電源恢復時,恢復系統斷電前狀態. (預設值)
Power Off 電源恢復時,立刻關閉系統.
Power On 電源恢復時,立刻啟動系統.
• Modem USE IRQ
3, 4, (預設值) 5, 7, N/A
• Modem Ring On / Wake On Lan (數據機開機/網路開機 )
Disabled 不啟動數據機開機 /網路開機 .
Enabled 啟動數據機開機 /網路開機 . (預設值)
57
Page 65
• PME Event Wake Up (電源管理事件喚醒功能)
Disabled 不啟動電源管理事件喚醒功能 .
Enabled 啟動電源管理事件喚醒功能 . (預設值)
• RTC Alarm Power On (定時開機)
您可以將 “RTC Alarm Power On” 這個選項設定為Enabled 並且輸入開機的時間
Disabled 不啟動此功能 . (預設值)
Enabled 啟動定時開機功能 .
若啟動定時開機功能 ,則可設定以下時間 .
Alarm Date : Every Day,1~31
Alarm Hour: 0~23
Alarm Minute : 0~59
Alarm Second : 0~59
BIOS 設定
58
Page 66
6VX-4X 主機板
隨插即用與 PCI 組態設定
AMIBIOS SETUP –PNP/PCI CONFIGURATION SETUP
( C ) 1999 American Megatrends, Inc. All Rights Reserved
Plug and Play Aware O/S :No
Reset Configuration Data :No
VGA Boot From :AGP
PCI VGA Palette Snoop :Disabled
DMA Channel 0 :PnP
DMA Channel 1 :PnP
DMA Channel 3 :PnP
DMA Channel 5 :PnP
DMA Channel 6 :PnP
DMA Channel 7 :PnP
IRQ 3 :PCI/PnP
IRQ 4 :PCI/PnP
IRQ 5 :PCI/PnP
IRQ 7 :PCI/PnP
IRQ 9 :PCI/PnP
IRQ 10 :PCI/PnP F1 : Help PU/PD/+/- : Modify
IRQ 11 :PCI/PnP F5 : Old Values (Shift)F2 :Color
IRQ 14 :PCI/PnP F6 : Load BIOS Defaults
IRQ 15 :PCI/PnP F7 : Load Setup Defaults
ESC : Quit ↑↓←→ : Select Item
圖 6: 隨插即用與 PCI 組態設定
• Plug and Play Aware O/S (是否安裝 PnP 作業系統 )
Yes
No
O/S 有察覺隨插既用 (PnP)的功能 .
O/S 沒有察覺隨插既用 (PnP)的功能 . (預設值)
• Reset Configuration Data (清除組態資料)
指示 BIOS 將所有 PnP 等相關組態清除,以便寫入或恢復部份預設值。
Yes
No
執行 Reset Configuration Data 動作.
不執行 Reset Configuration Data. (預設值)
• VGA Boot From
AGP 設定 VGA Boot From 為 AGP. (預設值)
PCI 設定 VGA Boot From 為 PCI.
59
Page 67
• PCI/VGA Palette Snoop (顏色校正)
當您安裝 MPEG 後,若發現顯示顏色異常,可試設定此值為 Enabled,以校正
顏色輸出。
Enabled
Disabled
要作顏色校正動作
不需要作顏色校正動作.(預設值
.
)
• DMA (0,1,3,5,6,7)
PnP 指定給 PnP 介面卡使用 .
ISA/EISA 指定給 ISA/EISA 的介面卡使用 .
• IRQ (3,4,5,7,9,10,11,12,14,15)
PCI/PnP 指定給 PCI/PnP 介面卡使用 .
ISA/EISA 指定給 ISA/EISA 的介面卡使用 .
BIOS 設定
60
Page 68
6VX-4X 主機板
F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
載入BIOS 預設值
AMIBIOS SIMPLE SETUP UTILITY -VERSION 1.20C
( C ) 1999 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP HARDWARE MONITOR SETUP
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP/PCI CONFIGURATION IDE HDD AUTO DETEC TION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values
Load BIOS Defaults (Y/N)? N
Load BIOS Default except Standard CMOS Setup
圖 7: 載入 BIOS 預設值
• Load BIOS Defaults
請按<Y >、<Enter >,即可載入BIOS 預設值。
61
Page 69
載入SETUP 預設值
AMIBIOS SIMPLE SETUP UTILITY-VERSION 1.20C
( C ) 1999 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP HARDWARE MONITOR SETUP
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP/PCI CONFIGURATION IDE HDD AUTO DETE CTION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values
F6 : Load BIOS Defaults F7: Load Setup Defaults F
Load SETUP Defaults (Y/N)? N
Load Setup Default except Standard CMOS Setup
圖 8: 載入SETUP 預設值
• Load Setup Defaults
請按<Y >、<Enter >,即可載入 Setup 預設值。
BIOS 設定
62
Page 70
6VX-4X 主機板
整合週邊設定
AMIBIOS SETUP –INTEGRATED PERIPHERAL
( C ) 1999 American Megatrends, Inc. All Rights Reserved
OnBoard IDE :Both Game Port (200h-207h) :Enabled
OnBoard FDC :Auto
OnBoard Serial Port 1 :Auto
OnBoard Serial Port 2 :Auto
Serial Port 2 Mode :Normal
Duplex Mode :N/A
OnBoard Parallel Port :Auto
Parallel Port Mode :Normal
Parallel Port DMA :N/A
Parallel Port IRQ :Auto
OnBoard AC’97 Audio :Auto
OnBoard MC’97 Modem :Auto
OnBoard Legacy Audio :Enabled
Sound Blaster :Disabled
SB I/O Base Address :220h-22Fh
SB IRQ Select :IRQ 5
SB DMA Select :DMA 1 F1 : Help PU/PD/+/- : Modify
MPU-401 :Disabled F5 : Old Values (Shift)F2 :Color
MPU-401 I/O Address :330h-333h F6 : Load BIOS Defaults
FM Port (388h-38Bh) :Disabled F7 : Load Setup Defaults
ESC : Quit ↑↓←→ : Select Item
圖 9: 內建整合週邊設定
• OnBoard IDE (內建 IDE 介面 )
Disabled
Both
Primary
Secondary
關閉內建 IDE 介面.
設定內建 IDE 介面為 Both.(預設值)
設定內建 IDE 介面為 Primary.
設定內建 IDE 介面為 Secondary.
• OnBoard FDC (內建軟碟介面)
Enabled 要使用主機板內建的軟碟介面.
Disabled 不使用主機板內建的軟碟介面.
Auto 自動偵測主機板內建的軟碟介面. (預設值 )
• OnBoard Serial Port 1(內建串列插座介面 1)
Auto 由 BIOS 自動設定 . (預設值)
3F8/COM1 指定內建串列插座 1 且使用 3F8 位址.
2F8/COM2 指定內建串列插座 1 且使用 2F8 位址.
3E8/COM3 指定內建串列插座 1 且使用 3E8位址.
2E8/COM4 指定內建串列插座 1 且使用 2E8位址.
Disabled 關閉內建串列插座 1.
63
Page 71
BIOS 設定
• OnBoard Serial Port 2 (內建串列插座介面 2)
Auto 由 BIOS 自動設定 . (預設值)
3F8/COM1 指定內建串列插座 2 且使用 3F8 位址.
2F8/COM2 指定內建串列插座 2 且使用 2F8 位址.
3E8/COM3 指定內建串列插座 2 且使用 3E8位址.
2E8/COM4 指定內建串列插座 2 且使用 2E8位址.
Disabled 關閉內建串列插座 2.
• Serial Port 2 Mode (此選項可由您自行決定內建 I/O 晶片串列埠 2 的模式 )
ASKIR
IrDA
Normal
設定內建 I/O 晶片串列埠 2 為 ASKIR 模式.
設定內建 I/O 晶片串列埠 2 為 IrDA 模式.
主機板上 I/O 支援正常模式.(預設值)
• Duplex Mode
N/A
Half Duplex
Full Duplex
關閉此功能
設定
IR
設定
IR
預設值
. (
模式為半雙工
模式為全雙工
)
.
.
• OnBoard Parallel port (內建並列插座)
378
278
3BC 指定內建並列插座位址為 3BC.
Auto 將內建並列插座位址設為自動偵測 . (預設值)
Disabled 關閉內建的並列插座 .
指定內建並列插座位址為
指定內建並列插座位址為
378.
278.
• Parallel Port Mode (並列插座模式)
EPP 使用 EPP( Enhanced Parallel Port)傳輸模式 .
ECP 使用 ECP( Extended Capabilities Port)傳輸模式 .
Normal 支援一般速度單向傳輸 . (預設值)
• Parallel Port DMA (並列插座 DMA 設定 )
N/A 關閉此功能 . (預設值 )
0 設定 Parallel Port DMA 為 0.
1 設定 Parallel Port DMA 為 1.
3 設定 Parallel Port DMA 為 3 .
Auto 設定 Parallel Port DMA 為自動偵測 .
64
Page 72
6VX-4X 主機板
• Parallel Port IRQ (並列插座 IRQ 設定 )
7 設定 Parallel Port IRQ 為 7.
5 設定 Parallel Port IRQ 為 5.
Auto 設定 Parallel Port IRQ 為自動偵測 . (預設值 )
• OnBoard AC’97 Audio
Auto 設定 AC’97 Audio 為自動偵測 .(預設值 )
Disabled 關閉 AC’97 Audio.
• OnBoard MC’97 Modem
Auto 設定 MC’97 Modem 為自動偵測 . (預設值 )
Disabled 關閉 MC’97 Modem.
• OnBoard Legacy Audio
Enabled 開啟 OnBoard Legacy Audio 功能 . (預設值 )
Disabled 關閉此功能 .
• Sound Blaster
Enabled 開啟 Sound Blaster 功能 .
Disabled 關閉此功能 . (預設值)
• SB I/O Base Address
220h-22Fh 設 SB I/O Base位置為 220h-22Fh. (預設值)
280h-28Fh 設 SB I/O Base位置為 280h-28Fh.
260h-26Fh 設 SB I/O Base位置為 260h-26Fh.
240h-24Fh 設 SB I/O Base位置為 240h-24Fh.
• SB IRQ Select
IRQ 9 / 5 / 7/ 10(預設值 : 5 ).
• SB DMA Select
DMA 0 / 1 / 2/ 3(預設值 : 1 ).
• MPU-401
Enabled 啟動 MPU-401.
Disabled 關閉 MPU-401. (預設值)
65
Page 73
• MUP-401 I/O Address
330h-333h 設 MUP-401 I/O 位置為 330h-333h. (預設值)
300h-303h 設 MUP-401 I/O 位置為 300h-303h.
310h-313h 設 MUP-401 I/O 位置為 310h-313h.
320h-323h 設 MUP-401 I/O 位置為 320h-323h.
• FM Port (388h-38Bh)
BIOS 設定
Enabled
Disabled
• Game Port (200h-207h)
Enabled
Disabled
啟動 FM Port (388h-38Bh).
關閉 FM Port (388h-38Bh). (預設值)
啟動 Game Port (200h-207h). (預設值)
關閉 Game Port (200h-207h).
66
Page 74
6VX-4X 主機板
硬體監視設定
AMIBIOS SETUP –HARDWARE MONITOR
ACPI Shut Down Temperature
Current CPU Temp. :36° C/96° F
Current System Temp. :28° C/82° F
Case Status Closed
Current CPU Fan Speed :5487 RPM
Current System Fan Speed :0 RPM
Vcore :2.075V
+3.300V :3.590V
+5.000V :5.119V
+12.000V :11.926V
F1 : Help PU/PD/+/- : Modify
F5 : Old Values (Shift)F2 :Color
F6 : Load BIOS Defaults
F7 : Load Setup Defaults
( C ) 1999 American Megatrends, Inc. All Rights Reserved
:65° C/149° F
ESC : Quit ↑↓←→ : Select Item
圖 10: 硬體監視設定
• ACPI Shutdown Temp. (°C / ° F)
(此功能僅在系統有支援 ACPI 模式下有效)
Disabled 關閉此功能 .
60° C / 140° F 監控 CPU 溫度在 60° C / 149° F, 若溫度 > 60° C / 140° F 系
統將自動關機 .
65° C / 149° F 監控 CPU 溫度在 65° C / 149° F, 若溫度 > 65° C / 149° F 系
統將自動關機 . (預設值)
70° C / 158° F 監控 CPU 溫度在 70° C / 158° F, 若溫度 > 70° C / 158° F 系
統將自動關機 .
75° C / 167° F 監控 CPU 溫度在 75° C / 167° F, 若溫度 > 75° C / 167° F 系
統將自動關機 .
67
Page 75
• Current CPU Temp. (°C / °F)
自動偵測CPU 溫度
• Current System Tem. (°C / °F)
自動偵測系統溫度
• Current CPU / System FAN Speed
自動偵測風扇的轉速
• Current Voltage (V) VCORE / +3.3V / +12V / +5V
自動偵測系統的電壓狀態.
BIOS 設定
68
Page 76
6VX-4X 主機板
d BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
管理者(Supervisor)/ 使用者(User) 密碼
當您想設定密碼時,請於主畫面下選擇好項目,並按下 Enter ,畫面中間即出現
的方框讓您輸入密碼:
AMIBIOS SIMPLE SETUP UTILITY -VERSION 1.20
( C ) 1999 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP HARDWARE MONITOR SETUP
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values
F6 : Loa
圖 11: 管理者(Supervisor)/ 使用者(User) 密碼
最多可以輸入8 個字元,輸入完畢後按下Enter ,BIOS會要求再輸入一次,以確定剛
剛沒有打錯,若兩次密碼吻合,便將之記錄下來。
Enter new supervisor password:
Chang /Set /Disabled Password
如果您想取消密碼,只需在輸入新密碼時,直接按Enter,這時BIOS
會顯示「 PASSWORD DISABLED」,也就是關閉密碼功能,那麼下次開機時,
就不會再被要求輸入密碼了。
69
Page 77
BIOS 設定
自動偵測IDE 硬碟
AMIBIOS SETUP – STANDARD CMOS SETUP
( C ) 1999 American Megatrends, Inc. All Rights Reserved
Date (mm/dd/yyyy) : Sat Jan 01, 2000
Time (hh/mm/ss) : 10:36:24
Pri Master : Not Installed
Pri Slave : Not Installed
Sec Master : Not Installed
Sec Slave : Not Installed
Floppy Drive A: 1.44 MB 3 ½
Floppy Drive B: Not Installed
Boot Sector Virus Protection : Disabled
Month: Jan – Dec ESC : Exit
Day: 01 – 31 ↑↓ : Select Item
Year : 2000– 2099 PU/PD/+/– : Modify
(Shift)F2 : Color
當 BIOS 偵測出結果時,通常會有三種 Mode 可供選擇,即 Normal 、LBA 與 LARGE,
而目前的 BIOS 多會將 LBA 擺在第一項,因此只需按Y,即可將參數寫入 STANDARD
CMOS 中,但記得離開 CMOS 時要存檔。
TYPE SIZE CYLS HEAD PRECOMP LANDZ SECTOR MODE
Base Memory : 640 Kb
Other Memory : 384 Kb
Extended Memory : 31Mb
Total Memory : 32Mb
圖 12: 自動偵測 IDE 硬碟
70
Page 78
6VX-4X 主機板
F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
離開 SETUP 並儲存設定結果
AMIBIOS SIMPLE SETUP UTILITY -VERSION 1.20C
( C ) 1999 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP HARDWARE MONITOR SETUP
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP/PCI CONFIGURATION IDE HDD AUTO DETEC TION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values
當您設定好 CMOS 內容後,於主畫面中按 F10 或選擇「SAVE & EXIT SETUP 」,即會
出現畫面:
若按Y 並按下 Enter,即可儲存所有設定結果到 RTC 中的 CMOS RAM並離開
Setup U tility 。若不想儲存,則按 N或 Esc皆可回到主畫面中。
SAVE to CMOS and EXIT(Y/N)? Y
Save Data to CMOS & Exit Setup
圖 13: 離開 SETUP 並儲存設定結果
71
Page 79
離開SETUP 但不儲存設定結果
F6 : Load BIOS Defaults F7: Load Setup Defaults F10: Save & Exit
AMIBIOS SIMPLE SETUP UTILITY -VERSION 1.20C
( C ) 1999 American Megatrends, Inc. All Rights Reserved
STANDARD CMOS SETUP INTEGRATED PERIPHERALS
BIOS FEATURES SETUP HARDWARE MONITOR SETUP
CHIPSET FEATURES SETUP SUPERVISOR PASSWORD
POWER MANAGEMENT SETUP USER PASSWORD
PNP/PCI CONFIGURATION IDE HDD AUTO DETECTION
LOAD BIOS DEFAULTS SAVE & EXIT SETUP
LOAD SETUP DEFAULTS EXIT WITHOUT SAVING
ESC : Quit ↑↓→← : Select Item (Shift) F2 : Change Color F5 : Old Values
Abandon all Datas & Exit Setup
圖 14: 離開 SETUP 但不儲存設定結果
若按Y 並按下Enter ,則離開Setup Utility 。若按N 或Esc 則可回到主畫面中.
BIOS 設定
72
Page 80
6VX-4X 主機板
1.按“VIA 4in 1 Service Pack
附錄
附錄 A : 安裝VIA 系列VT82C686 晶片組驅動程式
A.安裝VIA 4 in 1 Service Pack Utility:
將驅動程式光碟(TUCD)置入光碟機中,光碟機將自動執行.出現以下畫面,請參考以
下步驟進行安裝.(若沒有自動執行程式,請在” 我的電腦” 點選光碟機ICON ).
Utility” 選項
(1)
(3)
(2)
3.按 “Yes”.
(4)
4.按 “Next”.
(5)
5.按 “Next”.
(6)
73
Page 81
附錄
(7)
8.按 “Next”. 9.按 “Next”.
(9)
(8)
(10)
(11)
重新開機
(12)
74
Page 82
6VX-4X 主機板
B. 安裝 AC’97 Audio Driver:
將驅動程式光碟(TUCD)置入光碟機中,光碟機將自動執行.出現以下畫面,請參考以
下步驟進行安裝.(若沒有自動執行程式,請在”我的電腦”點選光碟機ICON ).
1. 按 “AC’97 Audio Driver” 選項
(1)
(3)
(2)
3.按 “Next”.
(4)
重新開機
(5)
75
Page 83
附錄
C. 安裝 Hardware Monitor:
將驅動程式光碟(TUCD)置入光碟機中,光碟機將自動執行.出現以下畫面,請參考以
下步驟進行安裝.(若沒有自動執行程式,請在”我的電腦”點選光碟機ICON ).
選項
(2)
4.按 “Next” 完成
(1)
(3)
(5)
3. 按 “Next”.
裝.
(4)
會完成安
(6)
76
Page 84
6VX-4X 主機板
附錄 B : 安裝 AU8810 驅動程式
A. 安裝驅動程式
假如您有舊的驅動程式,請先將它們移除.如 B 部份的描述.
1.打開系統 , 將 "Intel Chipset Series Mainboard Utility CD" CD 片放入 CD-ROM
機內 .
2.在這段期間 ,Windows 95/98 會偵測 Vortex PCI board 並顯示訊息 ,例如 "找到新的
硬體".假如 Windows 提示您這個設備是"PCI 多媒體音效裝置", 指定 Vortex 程式
位置.
Note: 有一些 Windows 95 版本(如 OSR2) 並不顯示這個替代的提示,它們會問那
一個是適當的磁碟機或光碟機設備.
安裝驅動程式可能含有 Vortex PCI audio, Vortex wavetable, Vortexmixer, DOS modem
port, Vortex gameport interface, Vortex MPU401 interface, 和 Vortex Sound Blaster emulation.
取決於 Windows 95 版本和系統的結構, 您可以參考以下提供數個檔案的位置.
這裡是您可能可以獲得的 CD-ROM 目錄位置 :
Vortex Installation & Driver Disk \aureal\win9X
Windows 95/98 Installation Disk \aureal\win9X
Microsoft DirectX \Utiltiy\directx\dxsetup
Vortex Application Setup \aureal\win9X
PCI Multifunction Audio Device \aureal\win9X
B. 移除 WINDOWS 95/98 驅動程式
移除 Vortex 軟體 , 您可以跟著以下的步驟 :
1.打開 Windows 95/98 裝置管理員 (在我的電腦按滑鼠右鍵並選擇內
容 ).
2.打開多媒體裝置設備選擇 "Vortex Multifunction PCI Platform"
3.在裝置管理員視窗上按 "移除"鍵.
4.這個驅動程式將從記憶體移除 ,但仍存在硬碟裡 .
從硬碟中刪除這個檔案 :
a. 打開 Windows 95/98 控制台裡的 "新增/移除程式" 程式.
b. 移除驅動程式, 連按二次 "Aureal Vortex". 這個 Vortex 移除程式開始啟
動 .
c. 移除展示應用程式, 連按二次 "Aureal Vortex Applications".
這裡不需要重新啟動電腦.
技術支援請連絡您的主機板廠商.
Aureal. A3D, A3D-I, A3D-Interactive, 及 Aureal logo 是商品商標並且 Vortex 已經 Aureal
Semiconductor Inc. 公司註冊過商標. 所有商標皆為該公司所有.
77
Page 85
附錄
附錄 C : BIOS 更新程序
BIOS 更新程序:
ü 請檢查你的主機板 BIOS 廠商(AMI 或 AWARD).
ü 建議您複製驅動程式光碟內”AWDFlash.exe 或 AMIFlash.exe” (D:\>U tility \BIOSFlash)
和 BIOS 內容等檔案到您的硬碟內某一個目錄之下 .
[ i.e: C:\>Utility \ (C:表示您的硬碟機所在的磁碟機代號 /Utility :表示您自行建立的
目錄名稱 )]
ü 重新啟動您的系統並進入 Win95/98 的 MS-DOS 模式或命令列程式
(Command prompt only)之後,進入更新 BIOS 檔案所放置的路徑中.
ü 使用”AWDFlash.exe 或 AMIFlash.exe”去更新 BIOS , 即鍵入下列指令:
C:\Utility\”AWDFlash或 AMIFlash <BIOS 內容檔>
ü 此更新程序已經完成, 請重新啟動你的系統.
MNote: 請從website (WWW.gigabyte.com.tw)下載新的BIOS或 是向您購買的公司詢問
此機種新版的 BIOS.
78