GF Signet PORTAFLOW 220-330 User Manual

PORTAFLOW 220/330 Portable Ultrasonic Flowmeter
Features
• Large, easy to read graphic display with backlighting
• Easy to install thanks to flexible guide rails
• Rechargeable battery for up to 20 hours mobile operation
• Simple ‘Quick Start’ set up procedure
• Data logger for 198k data points (Type PF330)
• Analog and pulse outputs
The Portaflow range brings simplicity to the non-invasive measurement of liquid flow. Portaflow offers the user quick and accurate flow measurement with its easy to follow menu and simple set up. Results can be achieved within minutes of opening the case. Compact, rugged and reliable, the Portaflow range has been designed to provide sustained performance in industrial environments.
Applications
• Potable Water
• River Water
• Cooling Water
• Demineralised Water
• Water/Glycol Solutions
• Chemicals
- Leak Detection
- Boiler Testing
Specifications
General
DSP Measurement Technique Transit time Flow Velocity Range 0.1 m/s - 20 m/s Accuracy
Repeatability ±0.5% of measured value or ±0.02 m/s whichever is the greater Response Time Selectable Flow Units Velocity m/sec, ft/sec.
Selectable Total Volume Units l, gal, USgals, Barrel, m³ Total Volume 12 digits Menu Languages EN, DE, FR, RU, SWE, IT, SP, P, NO, DEN
Environmental
Operating Temperature -20 °C to 50 °C -4 °F to 122 °F Storage Temperature -25 °C to 65 °C -13 °F to 149 °F
Pipe Wall Temperature -20 °C to 135 °C -4 °F to 275 °F Operating Humidity
Applicable Pipe Types
Pipe Materials PVDF-SYGEF, PP-PROGEF, PE-ELGEF, PB-INSTAFLEX, ABS, PVC-U/PVC-C, Mild Steel,
Pipe Dimension (OD) Type PF220 13 mm to 1000 mm 0.5 in. to 39 in.
Type PF330 13 mm to 2000 mm 0.5 in. to 78 in. Pipe Wall Thickness 1 mm to 75 mm 0.04 in. to 3 in. Pipe Lining Applicable pipe linings include Rubber, Glass, Concrete, Epoxy, Steel Pipe Lining Thickness 0 mm to 10 mm 0 in. to 0.4 in.
Electrical
Supply Voltage 9 to 24 V DC Power Consumption Max. 10.5 W
Battery
Technology 5-cell NiMH
Capacity 3.8 Ah
Operating Time
(typical)
Recharge Time 6.5 h
Service Life
Power supply
Input Voltage 90 to 264 V AC (47 to 63 Hz) Output Voltage 12 V DC Output Current Max. 1.5 A Approvals UL, CUL, TUV, CB, CE
Outputs
Analog Output Range 4 to 20 mA, 0 to 20 mA, 0 to 16 mA
Resolution 0.1% of full scale
Load Max. 620 Ω
Isolation 1500 V Opto-isolated
Alarm Current Adjustable between 0 to 26mA Pulse Output Type Digital MOSFET relay
Pulse Repetition Max. 500 pps, user programmable
Pulse Width 5 - 500 ms, user programmable
Voltage Max. 48 V
Current Max. 500 mA
Isolation 1500 V opto isolated USB Interface
(PF330 only)
RS-232 Interface (PF330 only)
www.gfsignet.com
Protocol Supports full speed (12Mbits/sec) data connection
Software USB driver software is provided with the package
Connector Proprietary industrial connector
Protocol Serial RS-232 communication including handshaking
Connector Proprietary industrial connector (GND, RxD, TxD, DTR, DSR)
Pipe ID >75 mm ±0.5% to ±2% of flow reading for flow rate >0.2 m/s Pipe ID 13 mm - 75 mm All pipe ID's
< 500 ms depending on pipe diameter
Volume "l/s, l/min, l/h, gal/min, gal/h, USgals/min, USgals/h, Barrel/h,
Max. 90% relative humidity @ 50°C (122 °F)
Ductile Iron, Stainless Steel 316, Copper
Typically 20 hours continuous with backlight and 4-20mA output OFF
>500 charge/discharge cycles
±3% of flow reading for flow rate >0.2 m/s ±6% of flow reading for flow rate <0.2 m/s
Barrel/day, m³/s, m³/min, m³/h"