IMPORTANT SAFETY INSTRUCTIONS
This heater should be installed by a competent person (i.e. a qualified electrician) in accordance with the current edition of the IEE wiring regulations (BS 7671) and appropriate statutory regulations.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN This heater has a 2kW maximum rating and is designed for permanent high level wall mounting at a
minimum height of 1800mm above the room floor. Before installing the heater check that the supply voltage of the installation matches the voltage
marked on the heater. This heater is suitable for use at 230 – 240V 50Hz supply voltages.
Safety Warnings
Do not use or install heater outdoors
Do not install the heater directly above or below a fixed socket outlet
Do not cover or obstruct heater grilles as this may cause overheating or fire
Do not use the heater to dry clothes
Do not touch the heater with wet hands
Do not use the heater if it has been dropped or damaged in any way
Do not allow any objects to be inserted in to the heater inlet or outlet grill es
Do not allow young children, the aged or infirm to use the heater without supervision
If the heater supply cord becomes damaged it must be replaced by a qualified person or
service engineer
In the event of a fault occurring do not attempt to repair the heater. This must only be carried out by a qualified person or service engineer
There are no user serviceable parts supplied with the heater
INSTALLATION
Electrical Connection
BEFORE COMMENCING ANY INSTALLATION WORK OR MAINTENANCE ALWAYS ENSURE THAT THE ELECTRICAL SUPPLY IS SWITCHED OFF
For additional safety, remove the fuse or switch off the circuit breaker for the relevant supply circuit at the main fuse box or consumer unit.
Ensure that no one else has access that would enable the supply to be inadvertently reconnected. The supply circuit used for connection of the heater must be appropriate for the rating of the heater
and must be protected with a 13A fuse DO NOT CONNECT THE HEATER TO A LIGHTING SUPPLY CIRCUIT
Wiring
The power supply cord fitted to the heater is coloured as follows: BROWN: LIVE
BLUE: NEUTRAL THIS HEATER IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION