GE Security 430222005, 430222006 Specsheet

Page 1
U.S.
front view
side
view
1.75”
[44.5mm]
1.0”
[
25.4mm]
4.20
[106.7mm]
T 855 536 3573 F 561 998 6224
Asia T 65 6424 7932 F 65 6424 7978
Australia T 61 3 9239 1200 F 61 3 9239 1299
Canada T 800 267 6317 F 613 737 5517
EMEA T 48 58 326 22 40 F 48 58 326 22 41
Latin America T 503 589 8614 F 561 994 6572
www.utcfireandsecurity.com
© 2012 UTC Fire & Security. All rights reserved.
UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065, USA
Transition Series
T-100 Model Reader
Description
The T-100 Transition™ Series card reader is a card serial number reader compatible with the following 125 kHz Proximity technologies:
CASI ProxLite®
•HID
®
Proximity
Mounting the reader
1. Find a suitable mounting position on the door frame or wall.
2. Drill two vertical mounting holes 2.25” (57.2 mm) apart on the mounting surface of the door frame or wall.
Figure 1. Dimensions
3. Drill one 1.00” (25.4 mm) diameter hole in wall for the pigtail wire connection.
4. Follow the Cable Connection Chart to connect the reader to the field panel.
5. Mount the base plate to the wall using the supplied screws.
6. Hook the top of the reader case to the top of the base plate and press into place.
Figure 2. Base plate, reader case, and top cover
7. Install the supplied screw in the base of the reader.
8. Snap the cover on the top of the case.
Connecting the cable
1. The readers are supplied with a 8-conductor cable pigtail with drain wire. Connect the pigtail to the host panel. Use the Cable Connection Chart (below) to correctly match the color of each wire.
Color Signal
Black Ground
Blue Beeper
Brown Red LED Control
Green Data 0
Orange Green LED Control
Red 5 to 16 VDC
White Data 1
Drain Shield Ground
2. Use a DC power source between 5-16 VDC.
3. Connect the reader’s drain wire to the cable shield. Connect shield wires at the field panel.
Page 2
Testing the reader
1. Power up the reader. Verify the power-on self test LED/beep sequence:
- green LED flashes; two short beeps
- yellow LED flashes; three short beeps
- red LED flashes
- yellow LED flashes
2. Verify the yellow LED lights indicating the reader is ready.
3. Present a badge that has been properly enrolled in the system. Verify the green LED lights and a short beep is heard.
Removing the cover
To remove the cover, squeeze the sides of the top cover and pull to release the cover.
The voltage specification for this reader is 5-16 VDC, although 12 VDC or greater is recommended for better performance and cable run distances.
The recommended cable gauge is 18-gauge to 22­gauge. Check with the cable supplier to determine the best choice for the application and installation distance.
FCC compliance
The FCC requires the following statement: This reader uses radio frequency energy, has been tested, and complies with the limits of FCC testing. Changes, modifications, or disregard of proper installation and instructions not expressly approved by UTC Fire & Security are strictly prohibited by the FCC and could void the user’s authority to operate the equipment.
Specifications
Colors Black, Charcoal,
Power supply Linear DC recommended
Voltage range 5 - 16 VDC
Temperature
a
range
Cable distance to
b
panel
Read Range
(Distances may vary depending on environment.)
Wiegand
d
output
Regulatory approvals and standards
UL evaluation for UL Listed Installations:
a. -25°F to 125°F (32°C to 52°C) b. 500 ft. (152.4 m) max. @ 22 awg 12 VDC
200 ft. (60.96 m) max. @ 22 awg 5 VDC
c. Proximity: up to 3.0" (7.62 cm)
HID Proximity: up to 3.0" (7.62 cm)
d. HID Proximity/Corporate 1000: Most formats (up
to 64-bit)
-31°F to 149°F (-35°C to 65°C)
200 ft. (60.96 m) max. @ 22 awg 12 VDC 300 ft. (91.44 m) max. @ 20 awg 12 VDC 500 ft. (152.4 m) max. @ 18 awg 12 VDC
c
Proximity Perfect cards are not supported by the Transition Series reader.
- CASI ProxLite: up to 3.5" (8.89 cm)
- HID Proximity: up to 3.5" (8.89 cm)
- Proximity: 4002 (40-bit) 12 digits
- HID Proximity/Corporate 1000: Most formats (26 to 174-bit)
UL 294, CE, and FCC Part 15
Light gray
Ordering information
Product Part numbers
T-100 (Black, 18" / 45.7 cm pigtail wire)
T-100 (Black, 84" / 214 cm pigtail wire)
T-100 (Charcoal, 18" / 45.7 cm pigtail wire)
T-100 (Charcoal, 84" / 214 cm pigtail wire)
T-100
Light gray, 18" / 45.7 cm pigtail wire)
(