GE Security 2251D-T-13X, 251D-R-1BX3 Specsheet

GE
Fiber Optic
Security
Overview
Programmable Outputs
Outputs are Normally Open (NO) and Normally Closed (NC) reed relays. A complete system consists of a transmitter and a receiver, configured as standalone units or as rack cards.
Superior Diagnostics
The SMARTS™ diagnostic technology provides system status LEDs that monitor the status of the data path and the optical signal.
Data Transmitters and Receivers
Standard Features
One-way transmission
Single and multimode models available
Single-channel contact closure
FM transmission
Operates up to 3.2 miles (5.2 km) (multimode) or up to 20 miles
• (32 km) (single mode)
13 dB optical budget
Optical AGC
SMARTS™ diagnostics
Standalone and rack configurations
Single-Channel Contact Closure
251D and 2251D
GE
Security
U.S.
U.S.
T (561) 998-6100
T (561) 998-6100
T 888-GE-SECURITY
T 888-GE-SECURITY
888-(437-3287)
888-(437-3287)
F 561 998 6224
F 561 998 6224
E rs-bctinfo@gesecurity.com Canada T 519 376 2430
Canada F 519 376 7258
T 519 376 2430
F 519 376 7258 Asia T 852-2907-8108
Asia F 852-2142-5063
T 852-2907-8108
F 852-2142-5063 Australia T 61-3-9239-1200
Australia F 61-3-9239-1299
T 61-3-9676-0270
F 61-3-9646-7005 Europe T 32-2-719-9847
Europe F 32-2-719-9846
T 44-113-238-1668
F 44-113-253-8121 Latin America T 305-593-4301
Latin America F 305-593-4300
T 305-593-4301
F 305-593-4300 www.gesecurity.com
www.gesecurity.com © 2005 General Electric Company All Rights Reserved
© 2005 General Electric Company
All Rights Reserved
Related Diagram
Contact In Contact Out
Transmitter
Receiver
Specifications
Data 251D (Multimode) 2251D (Single Mode)
Channels 1 simplex Formats Contact Closure Baud Rate 200 bps Contact Closure to Relay Output Time 5 ms Operating Mode Asynchronous Relay/Contact Rating 1 A @ 30 VDC Bit Error Rate <1.0E-9
Optical
Mode Multimode Single Mode Optical Budget 13 dB Emitter LED Laser Wavelength 850 nm 1310 nm Operating Distance 3.2 mi (5.2 km) Up to 20 mi (32 km) Transmitter Launch Power -15 dBm Receiver Sensitivity -28 dBm Gain Control Optical Automatic Gain Control (OAGC)
Electrical
Input Power 12 - 16 VAC or 13.5 VDC regulated (standalone);
13.5 VDC regulated (rack) Current Requirement 75 mA Power Consumption 1 W Power Factor 1 Protection Solid-state short circuit protection Power Supply Model 610P (AC) or Model 613P (DC) (optional)
Environmental
Operating Temperature -40 to 167 °F (-40 to 75 °C) Maximum Humidity 95% relative, noncondensing
Mechanical
Dimensions, Standalone Units (LWD) 3.75” x 2.81” x 1.10” (95 x 71 x 28 mm) Dimensions, Rack Units 1 slot (1.0”) Weight Standalone 0.26 lbs (0.12 kg); rack 0.51 (0.23 kg) Construction Aluminum
Optical Fiber
Ordering Information
Use the Configurators below to select the options available for these products.
Optical Budget based on 62.5 μm fiber, for 50/125 μm fiber subtract 3 dB. ∗∗ Operating distance is approximate and assumes best fiber. It will be affected by the type and number of splices in the fiber. Refer to update No. TB00-005, which can be found at www.gesecurity.com
As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GESecurity online at www.GESecurity.com or contact your GE Security sales representative. 250D-2006-09-2
imagination at work