GE Security 1285T-M, 1285T-N, 1285TW-M, 1285TW-N Specsheet

S E N T R O L
P R O D U C T I N F O R M A T I O N B U L L E T I N
1285T SERIES MAGNETIC CONTACTS
Surface Mount with Screw Terminal
Model numbers: 1282TW, 1283TW, 1284TW, 1285T, 1285TW, 1286T, 1286TW, 1287T, 1287TW, 1287TH
D
E
T
B
S
Y
I
L
U
A
N
D
D
A
U
LISTED
E
N
R
A
W
C
R
F
I
T
L
O
E
R
S
S
E
I
L
R
A
O
B
T
O
A
R
• Terminals feature self-lifting washers
• Captured screws with combination heads
• Angled terminals for easy installation
• Wide gap models available
• Mounting hardware included
The Sentrol 1285T Series surface mount magnetic contact is ideal for residential and commercial applications where terminal connects are preferred. The unit features Sems style terminals that have self­lifting washers and captured screws to prevent the screws from backing out. The screws have combination heads that accept either Phillips or flat blade drivers. The terminals are angled away from the mounting surface to allow for quick and easy installation. Snap-on covers conceal the terminals and mounting screws for a clean professional appearance. Wide gap, SPDT, and high security models are available.
continued
1285T Series Surface Mount Magnetic Contacts Screw Terminals
Architects and Engineering Specifications
The 1285T Series contact shall be a magnetic reed contact switch. Lead connection to contact shall be through No. 6 screw terminals angled 45° to provide easy access. A plastic cover shall be provided to protect the screw terminals and to discourage tampering. The contact shall be 2.54" (6.51 cm) W x 0.545" (1.39 cm) L x 0.690" (1.77 cm) D. The magnet shall be 1.74" (4.45 cm) L x 0.595" (1.52 cm) W x 0.545" (1.39 cm) D. Mounting holes shall be on 2.094" (5.33 cm) centers. Lock-pin spacers shall be provided that lock into the base of the contact and magnet, and which lock together to raise the contact or magnet from the surface for optimal alignment. Color shall be natural or mahogany brown.
Cover
Switch
Magnet
2.540"
6.51 cm
2.094"
5.33 cm
R
R
0.525"
1.34 cm
Magnet Part No. 1979
(Included)
0.545"
1.39 cm
0.690"
1.77 cm
0.595"
1.52 cm
Installation Instructions 1285T, 1286T, 1287T, 1282TW, 1283TW, 1284TW, 1285TW, 1286TW, 1287TW
Select desired mounting positions for contact and magnet. IMPORTANT: Align contact and magnet as directed on magnet base (switches are polarity sensitive). Attach contact and magnet to surface. Wire leads to terminals. Snap on cover.
1287TH
Mount contact in desired location. Attach ohmmeter to closed loop and common terminals. Meter should read INFINITY with magnet away from contact. Match up contact and magnet alignment arrows. Bring magnet toward contact until meter reads 0 ohms. Mark this point and continue bringing magnet towards contact until meter again reads INFINITY. Mark this point, and position the magnet between these two marks. With magnet positioned correctly, contact shall have balanced operation and will be more difficult to defeat if an external magnet is used in such an attempt.
Specifications: Form A (1282TW, 1285T, 1285TW)
Voltage: .................................................... 100 V AC/DC max
Current: .................................................................. 0.5 A max
Power: ................................................................... 7.5 W max
Form B (1283TW, 1286T, 1286TW)
Voltage: .......................................................30 V AC/DC max
Current: ................................................................ 0.25 A max
Power: ................................................................... 3.0 W max
Form C (1284TW, 1287T, 1287TW, 1287TH)
Voltage: .......................................................30 V AC/DC max
Current: ................................................................ 0.25 A max
Power: ................................................................... 3.0 W max
Ordering Information
Model Loop Type Electrical Color Choices Gap Lead Type Listing Number Configuration Distance*
1282TW Closed N/O Natural or mahogany brown Up to 2" #6 screw terminal UL/ULC 1283TW Open N/C Natural or mahogany brown Up to 2" #6 screw terminal UL/ULC 1284TW Open or Closed SPDT Natural or mahogany brown Up to 2" #6 screw terminal UL/ULC 1285T Closed N/O Natural or mahogany brown Up to 3/4" #6 screw terminal UL/ULC 1285TW Closed N/O Natural or mahogany brown Up to 1 1/2" #6 screw terminal UL/ULC 1286T Open N/C Natural or mahogany brown Up to 3/4" #6 screw terminal UL/ULC 1286TW Open N/C Natural or mahogany brown Up to 1 1/2" #6 screw terminal UL/ULC 1287T Open or Closed SPDT Natural or mahogany brown Up to 3/4" #6 screw terminal UL/ULC 1287TW Open or Closed SPDT Natural or mahogany brown Up to 1 1/2" #6 screw terminal UL/ULC 1287TH Open or Closed SPDT Natural or mahogany brown 3/8" min., 1 1/4" max. #6 screw terminal UL/ULC
NOTE:
* Gap distances are nominal make distance ± 20%.
Gap specifications are for switch to make. Break distance is approximately 1.1 to 1.5 times make.
CORPORATE HEADQUARTERS
12345 SW Leveton Dr., Tualatin, OR 97062 Tel.: 503.692.4052 Fax: 503.691.7566 http://www.sentrol.com
Sentrol reserves the right
to change specifications
without notice.
©1999 Sentrol
U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424
SENTROL
FaxBack: 800.483.2495
C-2112-FLG5K-1195
Printed on recycled paper
Loading...