Gerber 49-730, 49-731, 49-733 Installation Manual

Page 1
INSTALLATION / INSTALACIÓN / INSTALLATION
PREPARATION INSTRUCTIONS / INSTRUCCIONES
DE PREPARACIÓN / INSTRUCTIONS DE PRÉPARATION:
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
DEBE EVALUARSE EL TAMAÑO DE LOS CONDUCTOS DE ALIMENTACIÓN DE AGUA PARA OBTENER UN VOLUMEN DE AGUA ADECUADO EN CADA APARATO SANITARIO.
LES CONDUITES D’EAU DOIVENT ÊTRE DE LA BONNE DIMENSION POUR FOURNIR LE VOLUME D'EAU ADÉ­QUAT À CHAQUE APPAREIL.
• FLUSH ALL WATER LINES PRIOR TO INSTALLING FLUSHOMETER.
ENJUAGUE TODOS LOS CONDUCTOS DE AGUA ANTES DE INSTALAR LA VÁLVULA DE LIMPIEZA AUTOMÁTICA.
RINCER TOUTES LES CONDUITES D’EAU AVANT D’INSTALLER LE ROBINET DE CHASSE D’EAU.
Safetemp™ Pressure Balance Tub And
Shower Faucet
Safetemp
Grifo de presión balanceada
para bañera y ducha
Safetemp
Robinet à régulateur de
pression pour bain et douche
TOOLS REQUIRED:/HERRAMIENTAS NECESARIAS: / OUTILS REQUIS:
Driller
Taladradora Perceuse
Please note: For proper function, this valve has to be used with shower heads rated at 2.0 GPM (7.57 LPM) or higher.
Marking pencil
Marqueur Lápiz marcador
SAFETY TIPS
Caution: If you use soldering for the installation of this faucet, the seata cartridges and washers will have to be removed before turning on the flame. Damage to the cartridge and seats will occur if left intact while soldering and will result in the warranty being void on these parts.
Cover your drain to avoid loosing parts.
CONSEJOS DE SEGURIDAD
Advertencia: Si usa soldadura para la instalación de este grifo, remueva los componentes internos y las arandelas antes de encender la llama. Si no se remueven, estas piezas se dañarán durante la soldadura, lo que resultará en la anulación de la garantía para estas piezas.
Tape la boca del desagüe para prevenir la pérdida de piezas pequeñas.
CONSEILS DE SÉCURITÉ
Attention : Si vous effectuez l’installation de ce robinet par soudage, vous devez enlever les èges de cartouche et les rondelles avant d’allumer la flamme. La cartouche et les sièges seront endommagées s’ils sont laissés en place lors du soudage, entraînant ainsi l’ annulatio de la garantie de ces pièces.
Couvrez le drain à fin de ne pas perdre de pièces.
Ruler
Regla Règle
49-730 49-731
49-733
Shown
P
R
O
F
E
S
S
I
O
N
2500 Internationale Parkway, Woodridge, IL 60517, U.S.A.
(Sales Office/Oficina de ventas/Bureau de vente)
Toronto: 189 Earl Stewart Drive, Unit #5, Aurora, ON L4G 6V5, Canada
Montreal: 4610 Bois Franc, Montreal, QC H4S 1A7, Canada
E
C
N
A
GERBER
M
R
O
F
R
A
E
L
P
®
Gerber Plumbing Fixtures LLC.
(CS & Tech/SC y Tec./SC et Tech)
www.gerberonline.com 1-888-648-6466
/ Mostrado / Illustré
1
10/17
Page 2
Page 3
Safetemp Pressure
Balance Instructions Simplified:
1. Use a level, tape measure, and pencil to locate center lines of valve body, shower arm, and tub spout.
2. Align the plaster guard with the drawn lines and trace an outline of the plaster guard.
4. Cut out the traced plaster guard outline 1/8” larger than the original tracing. Use hole saws and a fine-toothed handsaw to remove wall material.
5. Mount valve body per rough­in or thin wall
application. Attach water supply lines and outlet lines.
Attach plaster guard for grouting tiles or other forms of interior finishing.
6. Install the trim and hardware. Flush the piping system for one minute. Attach the spout and showerhead.
The Anatomy of Your Product
Be sure that you’re buying genuine
16
15
17
14
18
19
23
16
7
4
3
2
1
5
20
10
9
21
13
24
PLASTER GUARD
22
8
11
6
GERBER
GERBER
ID# Description Chrome
1 ....... Shower Assy. .................... Not Sold
2 ....... Shower Head ..................... 49-199
3 ....... Shower Arm ...................... 49-111-G
4 ....... Flange ............................... 92-021
5 ....... Delux Showerhead ............ Not Sold
6 ....... Slip Spout ......................... 98-241
......... Spout w/IPS ...................... 92-573
7 ....... Safetemp
8 ....... Trim Sleeve ....................... 92-330
9 ....... Loop Hndl. Botton ............ 92-276
10 ..... Safetemp Handle ............... 97-020
11 ..... Hrdwtr. Hndl. Button ........ 94-211
12 ..... Hrdwtr. Handle Assy. ........ Not Sold
13 ..... Screw Package .................. 97-016
ID# Description Unfinished
14 ..... Cast Body w/IPS Connections ......................... Not Sold
12
15 ..... 1/2” MIPSx1/2”FIPS ......
16 ..... Cast Body w/Solder Connections .................... Not Sold
17 ..... 1/2” Cx1/2”C Stop / Solder .............................. Not Sold
18 ..... O-Ring ............................................................. 92-257
19 ..... Pressure Balance Cartridge S/A ....................... 97-014
20 ..... Pressure Balance Stem & Bonnet S/A ............. 97-022
21 ..... Safetemp Temper
22 ..... Bonnet for Pressure Balance Shower ............... 92-329
23 ..... 1/2” NPT Plug ................................................. 97-302
24 ..... Plug for Solder Connection ............................. 97-333
replacement parts!
Escutcheon ........ 97-018
.................................. Not Sold
ature Limit............................ 92-294
GERBER SAFETEMP & HARDWATER
7.0
6.0
5.0
4.0
3.0
2.0
1.0
FLOWRATE (gpm)
0.0
10 20 30 40 50 60 70 80 90 100
PRESSURE BALANCE VALVE
PRESSURE (gpm)
CAUTION:
Do not use scouring pads,
acid-based chemicals, or abrasive
cleaners to clean your faucet!
This will cause damage to the plated
or painted finishes!
Thank you for buying GERBER products!
Page 4
Adjusting the Limit Stop:
There is a factory temperature preset which can bechanged by removing the LIMIT STOP. See theexploded assembly for identification. Do not exceed 120° Fahrenheit! Local Plumbing Code will specify the maximum temperaturesettings for the LIMIT STOP.
1. Pull out the TEMPERATURE LIMIT STOP.
2. Rotate the limiter Counter-Clockwise for COLDand Clockwise for HOT.
You may have to Seasonally adjust your limit stop.1
. Due to seasonal climate temperature chang­es youmay have to make minor adjustments to the limitstop. During the summer months readjust it for acooler setting and in winter for a warmer setting.
Brass Stem set to standard water inlet configuration: cold on right and hot on left
Brass Stem rotated 180° for non-standard water inlet configuration: cold on left and hot on right
The Limit Stop allows you to control the amount of HOT water so you can enjoy a consistently safe water temperature.
Back-to-Back Installation or HOTand COLD water supply inlets reversed
1. Remove the handle.
2. Rotate the brass stem 180° so that the
short flat side is UP.
3. Reassemble the handle.
4. Check the water temperature and reset
the limit stop if required.
LIMITED LIFETIME WARRANTY - CARTRIDGES
GPF warrants that the ceramic disc cartridge (the valve control of the faucet) will not leak or drip for as long as it is owned by the original purchaser. If the ceramic disc cartridge malfunctions or proves defective upon inspection by GPF after the valve has been returned, then GPF will repair or replace such part, at GPF's option, free of charge. GPF warrants that the washerless or compression type cartridge (the valve control of the faucet) will not leak or drip for a period of ten (10) years from the date of original purchase, as shown on the original consumer-purchaser's receipt. If the washerless or compres­sion type cartridge malfunctions or proves defective upon inspection by GPF after the valve has been returned, during the 10-year warranty period, then GPF will repair or replace such part, at GPF's option, free of charge. This Ten (10) Year Limited Warranty only applies to repair or replacement of defective washerless or compression type cartridge
TWO (2) YEAR LIMITED WARRANTY ON OTHER PARTS
GPF warrants to the original consumer-purchaser of this product that for a period of two (2) years from the date of original purchase, this product will be free from defects in material and workmanship under normal, reasonable use in accordance with product instruc­tions. All mechanical faucets/fittings installed in accepted commercial installations carry a two (2) year limited warranty. All labor, shipping, and freight costs and any other charges incidental to warranty and service are to be borne by the original consumer-purchas­er. As the exclusive remedy for any breach of the above warranties, GPF agrees, at GPF's option, to repair or replace this product or any part thereof, which proves, upon inspection by GPF after such product is returned, to be defective in material or workmanship. GPF will not be liable for any labor, shipping, freight, or any other costs or charges incurred in connection with removal or replacement of the product or otherwise acting upon the above warranties, or for any costs associated with repair or replacement of any other personal property, building or installation materials. Installation or use of the faucet or valve not in accordance with product instruc­tions, or improper use, abuse or neglect of, or accident to, the faucet or valve, or moving the product from the location of its original installation will void the above warranties. If the Federal Consumer Product Warranties Act applies to the original purchaser of this product, then any implied warranties which may be applicable under state law, such as any implied warranty of merchantability or any implied warranty of fitness for a particular purpose, are limited with respect to the ceramic disc cartridge to twenty (20) years, washerless or compression type cartridge to ten (10) years and with respect to all other parts to two (2) years. The above warranties give you specific legal rights, and you may also have other rights which vary from state to state. Certain federal and state laws may limit or disallow disclaimers of incidental or consequential damages and/or limitations on implied warranties. For Technical service, call 888-648-6466
Loading...