Fact Sheet
E-Cell-3X Stack
Industrial Electrodeionization (EDI) Stacks
E-Cell*-3X is designed to:
Provide Ultrapure Water for industrial applications including Power, Semiconductor, and General Industry.
Produce Mixed Bed quality water on a continuous basis.
Require no caustic or acid for regeneration of ion exchange resin within the stack.
Be leak free, guaranteed.
Eliminate brine injection and concentrate recirculation, simplifying system design.
Description and Use
E-Cell-3X stacks are electrodeionization (EDI) stacks which use electrical current to deionize and polish reverse osmosis (RO) permeate water. The product water for the E-Cell-3X is at an Ultrapure level required in today’s demanding applications.
Typical Applications
Microelectronics
Power Generation (NOx, Boiler Feed)
General Industry
Quality Assurance
CE, UL & CSA marked
Manufactured in a ISO 9001:2000 facility
E-Cell-3X Stack Specifications
Nominal Flow |
5.0 m3/hr |
22.0 gpm |
Flow Rate Range |
2.27 – 6.36 m3/hr |
10 – 28 gpm |
Shipping Weight |
135 kg |
298 lbs |
|
|
|
Dimensions |
31cm x 61cm x 66cm |
12’’ x 24” x 26” |
(width x height x depth) |
|
|
Typical Performance
Product Quality
Resistivity |
> 16 MOhm-cm |
||
|
|
|
|
Sodium |
< 3 ppb |
|
|
|
|
|
|
Silica (SiO2) Removal |
Up to 99% or < 5 ppb |
||
|
|
|
|
Boron Removal |
> 95% |
|
|
|
|
|
|
Operating Parameters |
|
|
|
|
|
|
|
Recovery |
Up to 95% |
|
|
|
|
|
|
Concentrate Flow |
Counter current to |
||
|
Product Flow1 |
|
|
Voltage |
0–400 VDC |
|
|
|
|
|
|
Amperage |
0–5.2 ADC |
|
|
|
|
|
|
Inlet Pressure at Nominal Flow |
4.1–6.9 bar |
|
60–100 psi |
|
|
|
|
Pressure Drop at Nominal Flow |
1.4–2.8 bar |
|
20–40 psi |
|
|
|
|
Maximum Feed Water Specifications
Feed Water - Total Exchangea- |
<25 mg/l |
<25 ppm |
ble Anions (TEA as CaCO3) |
|
|
|
|
|
Feed Water – Conductivity, |
< 43 μS/cm |
< 43 μS/cm |
NaHCO3 equivalent |
|
|
|
|
|
Temperature |
5–40˚C |
40–104˚F |
|
|
|
Total Hardness (as CaCO3) |
< 1.0 mg/l |
< 1.0 ppm |
|
|
|
Silica (SiO2) |
< 1.0 mg/l |
< 1.0 ppm |
|
|
|
Total Organic Carbon (TOC as C) |
< 0.5 mg/l |
< 0.5 ppm |
|
|
|
Total Chlorine |
< 0.05 mg/l |
< 0.05 ppm |
|
|
|
Actual performance may vary depending on site conditions. Reference E-Calc projection software to verify actual performance. Patents pending.
1 Co-flow operation is acceptable when feed hardness concentrations are <0.1 ppm as CaCO3.
Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” . * Trademark of General Electric Company; may be registered in one or more countries.
©2011, General Electric Company. All rights reserved.
FSelE-Cell-3XStack_EN.doc Aug-11