Georg Fischer 3350 Ultrasonic Flow Meter Data Sheet

Page 1
GF Signet 3350
Full-Feature Transit-Time Ultrasonic Flow Meter System at an Affordable Price
Ultrasonic Flow Meters GF Signet 3350
The GF Signet 3350 is a state-of-the-art, economical alternative to magnetic, vortex and differential pressure transmitters. Advanced microprocessing detection methods combine
with a versatile design to provide accurate and obstructionless ow measurement of
clean water applications. The GF Signet 3350 features high reliability and accuracy (up to 0.5%), and long-term maintenance-free operation. Programming the GF Signet 3350 is simple via the front panel keypad; no PC is required for setup. The instrument features a high-resolution, 2-line, backlit display and signal quality indication. The non-intrusive,
clamp-on sensors are quickly installed without interrupting process ows or incurring
pressure loss.
Features
Flexible output options – Analog output,
totalizer pulse, relay outputs all included as standard options
Fast and easy installation – Simple,
menu-driven user interface enables quick setup without need to connect to a laptop PC
Compact and lightweight
Incorporates the latest LSI technology for compact, rugged design. Meter weighs less than 2 lbs
Quick response – Ultra-fast transit-time
processing (200 ms) suits high-speed batch processing measurements
Multilingual – Instrument setup and
display supported in English, Spanish, German, French and Japanese
Superior temperature compensation
Proprietary temperature and pressure compensation system completely eliminates error created by process
temperature and pressure uctuations
Performance Specications for the Converter
Fluid Conditions
Measured fluid
with minimal aeration (water, sea water,
hydrocarbons or uid with unknown
sound velocity) capable of ultrasonic wave propagation
Fluid turbidity 10000 deg. (mg/l) or less State of flow Well developed turbulent or
laminar ow in full pipe
Fluid temperature -4 to 212°F (-20 to
100°C)
Velocity range 0.010 to 33 ft/sec (0 to 10
m/sec) bi-directional ow
Homogeneous liquids
Piping Conditions
Pipe material
cast iron, copper, PVC, aluminum, FRP, PEEK, PVDF, PTFE, PFA and other
Pipe size 1.0 to 9.0 in. (25 to 225mm) Lining material Tar, epoxy, mortar, rubber,
other, none
Measurement Accuracy
Accuracy
±0.06 m/s (<2 m/s, 1 to 1-1/2 in. dia); ±2% of rate (>2 m/s, 2 to 9 in. dia); ±3% of rate (>2 m/s, 1 to 1-1/2 in. dia)
Linearity ±0.1% of scale Repeatability 0.5% or better
Carbon steel, stainless steel,
±0.04 m/s (<2 m/s, 2 to 9 in. dia);
Functional Specications for the Converter
Power supply 100 to 120 VAC ±10%, 50/60
Hz; 200 to 240 VAC ±10%, 50/60 Hz
Power consumption Approx. 10 VA/5W (DC) LCD display 2 line, 16 character per line,
backlight
LED display 2 color, green/red, signal
quality
Keypad 4-key, full menu-driven setup
functionality
Response time 200 ms or less Analog output signal 4 to 20mA DC,
multirange, fully programmable
Digital output signal Digital output 2
mechanical relay, 1 point with socket. Normal open/close selectable, capacity 220 VAC/30 VDC, 1 Amp. Total pulse range: 1 pulse per day to 1 pulse per second. Digital output: 1 open collector transistor, 1 point. Normal on/off selectable, capacity 30 VDC, 0.1 Amp. Total pulse range: 1 pulse per day to 100 pps.
Key Features
Flexible output options
Fast and easy installation
Compact and lightweight
Multilingual
Superior temperature compensation
Information subject to change without notice. Prices in USD. 021307
1
Page 2
GF Signet 3350 Ultrasonic Flow Meter
Specications (continued)
Ultrasonic Flow Meters Fuji Time Delta M-Flow
Digital output functions Forward/reverse
totalizer pulse, ow switch high/low, forward/reverse total alarm and overow, reverse ow detected
Display language English, French,
German, Spanish and Japanese
Measurement display screen System
units: English or metric, keypad selectable.
LCD display: Congurable from keypad,
select from among forward totalizer value,
reverse totalizer value, ow velocity, output range percentage and ow rate. Velocity/ow rate display: 7 digits. Velocity
units: English (ft/sec), metric (m/sec). Flow rate units: English (gal/sec, gal/min, gal/hr, kgal/hr, Mgal/d, ft3/sec, ft3/min, ft3/hr, Mft3/d, BBL/sec, BBL/min, BBL/hr, MBBL/ d), Metric (L/sec, L/min, L/hr, kL/hr, ML/d, m3/sec, m3/min, m3/hr, Mm3/d, BBL/sec, BBL/hr, BBL/min, MBBL/d). Totalizer display: 7 digits. Totalizer units English (gal, kgal, ft3, kft3, Mft3, mBBL, BBL, kBBL, ACRE-in, ACRE-ft), Metric (mL, L, m3, km3, Mm3, mBBL, BBL, kBBL). Zero adjustment: Automatic or manual zero
ow reference setting, keypad selectable.
Damping function: 0 to 100 sec, keypad
selectable. Low ow cutoff: 0 to 16.4 ft/sec
(0 to 5 m/sec). Burnout function: Analog output, hold/overscale/underscale/zero, keypad selectable; Totalizer, hold/count, keypad selectable; Working timer, 0 to 100 sec, keypad selectable
Physical Specications for the Converter
Ambient temperature -4 to 140°F (-20 to
60°C)
Ambient humidity Less than 90% RH Enclosure ABS Plastic Environmental rating NEMA-4 (IP65) Dimensions (HxWxD) 5.5 x 5.1 x 2.68 in.
(140 x 139 x 68mm)
Weight 1.76 lbs. (0.8 kg)
Detector Model 3550
Mounting method Detector mounting on
outside of pipe via steel bands, nylon belts, or steel wire
Straight pipe length Upstream side: 10D
or more recommended. downstream side: 5D or more recommended (Calibrated system conditions include a minimum
of 10 inner pipe diameters of upstream straight pipe run and a minimum of 5 inner pipe diameters of downstream pipe run. Longer runs may be necessary due to pipe configurations.)
Signal cable RG-58, RG-58A/U, 3D2V Cable length Standard length 16 ft.,
maximum length 100 ft. (30m)
Connection Converter: internal screw.
Detector: BNC (female)
Operating characteristics (pipe diameter
range/temperature range)
3550.100: 1.0 to 4.0 in (25 to 100mm)/-4 to 212°F (-20 to 100°C). 3550.200: 2.0 to
9.0 in (50 to 225mm)/-4 to 212°F (-20 to 100°C)
Ambient temperature range -4 to 212°F
(-20 to 100°C)
Environmental rating IP65 Material 3550.100 and 3550.200: Plastic
PBT housing, stainless steel mounting bracket
Dimension (WxHxD)/Weight 3550.100:
9.45 x 1.10 x 2.00 in./0.7 lbs. (240 x 27.9 x 50.8mm/0.3 kg); 3550.200: 14.20 x
1.10 x 2.00 in./0.9 lbs. (360.7 x 27.9 x
50.8mm/0.4 kg)
We attempt to provide you with complete information in this catalog. Because of the specific nature of ultrasonic technology, we strongly recommend you contact us regarding application and availability before placing your order.
Ordering Information
Converters
Included in standard delivery: Converter, manual, pipe clamp kit
3-3350-1 GF Signet 3350 xed transit-time ow meter converter, 110 VAC input $ 1,475
3-3350-2 GF Signet 3350 xed transit-time ow meter converter, 220 VAC input 1,475
Detectors
Each detector kit includes: Detector unit, 5m signal cable pair, mounting straps, 3.5 oz tube sonic coupling compound (silicone grease)
3-3550.100 2 MHz detector set, 1.0 to 4.0 in. pipe dia., -4 to 212°F 724
3-3550.200 2 MHz detector set, 2.0 to 9.0 in. pipe dia., -4 to 212°F 749
Accessories
3-3550.075 Pair of 50 ohm signal cables, 5 meters 75
3-3550.076 Pair of 50 ohm signal cables, 10 meters 150
3-3550.077 Pair of 50 ohm signal cables, 15 meters 225
3-3550.078 Pair of 50 ohm signal cables, 20 meters 300
3-3550.079 Pair of 50 ohm signal cables, 30 meters 450
3-3800-1000 Sonic coupling compound 15
3-3800-1001 Sonic coupling compound, silicone-free 35
3-3800-1002 RTV Compound 15
Information subject to change without notice. Prices in USD. 021307
2
Page 3
3350 Converter
Mounting hole
130 mm (5.1 in.)
70 mm (2.75 in.)
140 mm (5.5 in.)
170 mm (6.7 in.)
197 mm (7.75 in.)
Mounting plate
50.8 mm (2.0 in.)
240 mm
(9.45 in.)
3-3550.100
50.8 mm (2.0 in.)
360.6 mm (14.2 in.)
3-3550.200
Ultrasonic Flow Meters GF Signet 3350
3550.100 and 3550.200 Detector Sets
Information subject to change without notice. Prices in USD. 021307
3
Loading...