GF Signet 3350
Full-Feature Transit-Time Ultrasonic Flow Meter System at an Affordable Price
Ultrasonic Flow Meters GF Signet 3350
The GF Signet 3350 is a state-of-the-art, economical alternative to magnetic, vortex and
differential pressure transmitters. Advanced microprocessing detection methods combine
with a versatile design to provide accurate and obstructionless ow measurement of
clean water applications. The GF Signet 3350 features high reliability and accuracy (up
to 0.5%), and long-term maintenance-free operation. Programming the GF Signet 3350
is simple via the front panel keypad; no PC is required for setup. The instrument features
a high-resolution, 2-line, backlit display and signal quality indication. The non-intrusive,
clamp-on sensors are quickly installed without interrupting process ows or incurring
pressure loss.
Features
• Flexible output options – Analog output,
totalizer pulse, relay outputs all included
as standard options
• Fast and easy installation – Simple,
menu-driven user interface enables quick
setup without need to connect to a laptop
PC
• Compact and lightweight –
Incorporates the latest LSI technology for
compact, rugged design. Meter weighs
less than 2 lbs
• Quick response – Ultra-fast transit-time
processing (200 ms) suits high-speed
batch processing measurements
• Multilingual – Instrument setup and
display supported in English, Spanish,
German, French and Japanese
• Superior temperature compensation –
Proprietary temperature and pressure
compensation system completely
eliminates error created by process
temperature and pressure uctuations
Performance Specications
for the Converter
Fluid Conditions
Measured fluid
with minimal aeration (water, sea water,
hydrocarbons or uid with unknown
sound velocity) capable of ultrasonic wave
propagation
Fluid turbidity 10000 deg. (mg/l) or less
State of flow Well developed turbulent or
laminar ow in full pipe
Fluid temperature -4 to 212°F (-20 to
100°C)
Velocity range 0.010 to 33 ft/sec (0 to 10
m/sec) bi-directional ow
Homogeneous liquids
Piping Conditions
Pipe material
cast iron, copper, PVC, aluminum, FRP,
PEEK, PVDF, PTFE, PFA and other
Pipe size 1.0 to 9.0 in. (25 to 225mm)
Lining material Tar, epoxy, mortar, rubber,
other, none
Measurement Accuracy
Accuracy
±0.06 m/s (<2 m/s, 1 to 1-1/2 in. dia);
±2% of rate (>2 m/s, 2 to 9 in. dia);
±3% of rate (>2 m/s, 1 to 1-1/2 in. dia)
Linearity ±0.1% of scale
Repeatability 0.5% or better
Carbon steel, stainless steel,
±0.04 m/s (<2 m/s, 2 to 9 in. dia);
Functional Specications for
the Converter
Power supply 100 to 120 VAC ±10%, 50/60
Hz; 200 to 240 VAC ±10%, 50/60 Hz
Power consumption Approx. 10 VA/5W (DC)
LCD display 2 line, 16 character per line,
backlight
LED display 2 color, green/red, signal
quality
Keypad 4-key, full menu-driven setup
functionality
Response time 200 ms or less
Analog output signal 4 to 20mA DC,
multirange, fully programmable
Digital output signal Digital output 2
mechanical relay, 1 point with socket.
Normal open/close selectable, capacity
220 VAC/30 VDC, 1 Amp. Total pulse
range: 1 pulse per day to 1 pulse per
second. Digital output: 1 open collector
transistor, 1 point. Normal on/off selectable,
capacity 30 VDC, 0.1 Amp. Total pulse
range: 1 pulse per day to 100 pps.
Key Features
• Flexible output options
• Fast and easy installation
• Compact and lightweight
• Quick response
• Multilingual
• Superior temperature compensation
Information subject to change without notice. Prices in USD. 021307
1

GF Signet 3350 Ultrasonic Flow Meter
Specications (continued)
Ultrasonic Flow Meters Fuji Time Delta M-Flow
Digital output functions Forward/reverse
totalizer pulse, ow switch high/low,
forward/reverse total alarm and overow,
reverse ow detected
Display language English, French,
German, Spanish and Japanese
Measurement display screen System
units: English or metric, keypad selectable.
LCD display: Congurable from keypad,
select from among forward totalizer value,
reverse totalizer value, ow velocity,
output range percentage and ow rate.
Velocity/ow rate display: 7 digits. Velocity
units: English (ft/sec), metric (m/sec). Flow
rate units: English (gal/sec, gal/min, gal/hr,
kgal/hr, Mgal/d, ft3/sec, ft3/min, ft3/hr,
Mft3/d, BBL/sec, BBL/min, BBL/hr, MBBL/
d), Metric (L/sec, L/min, L/hr, kL/hr, ML/d,
m3/sec, m3/min, m3/hr, Mm3/d, BBL/sec,
BBL/hr, BBL/min, MBBL/d). Totalizer
display: 7 digits. Totalizer units English
(gal, kgal, ft3, kft3, Mft3, mBBL, BBL,
kBBL, ACRE-in, ACRE-ft), Metric (mL, L,
m3, km3, Mm3, mBBL, BBL, kBBL). Zero
adjustment: Automatic or manual zero
ow reference setting, keypad selectable.
Damping function: 0 to 100 sec, keypad
selectable. Low ow cutoff: 0 to 16.4 ft/sec
(0 to 5 m/sec). Burnout function: Analog
output, hold/overscale/underscale/zero,
keypad selectable; Totalizer, hold/count,
keypad selectable; Working timer, 0 to 100
sec, keypad selectable
Physical Specications for
the Converter
Ambient temperature -4 to 140°F (-20 to
60°C)
Ambient humidity Less than 90% RH
Enclosure ABS Plastic
Environmental rating NEMA-4 (IP65)
Dimensions (HxWxD) 5.5 x 5.1 x 2.68 in.
(140 x 139 x 68mm)
Weight 1.76 lbs. (0.8 kg)
Detector Model 3550
Mounting method Detector mounting on
outside of pipe via steel bands, nylon
belts, or steel wire
Straight pipe length Upstream side: 10D
or more recommended. downstream side:
5D or more recommended (Calibrated
system conditions include a minimum
of 10 inner pipe diameters of upstream
straight pipe run and a minimum of 5 inner
pipe diameters of downstream pipe run.
Longer runs may be necessary due to pipe
configurations.)
Signal cable RG-58, RG-58A/U, 3D2V
Cable length Standard length 16 ft.,
maximum length 100 ft. (30m)
Connection Converter: internal screw.
Detector: BNC (female)
Operating characteristics (pipe diameter
range/temperature range)
3550.100: 1.0 to 4.0 in (25 to 100mm)/-4
to 212°F (-20 to 100°C). 3550.200: 2.0 to
9.0 in (50 to 225mm)/-4 to 212°F (-20 to
100°C)
Ambient temperature range -4 to 212°F
(-20 to 100°C)
Environmental rating IP65
Material 3550.100 and 3550.200: Plastic
PBT housing, stainless steel mounting
bracket
Dimension (WxHxD)/Weight 3550.100:
9.45 x 1.10 x 2.00 in./0.7 lbs. (240 x 27.9
x 50.8mm/0.3 kg); 3550.200: 14.20 x
1.10 x 2.00 in./0.9 lbs. (360.7 x 27.9 x
50.8mm/0.4 kg)
We attempt to provide you with complete information in this catalog. Because of the specific nature
of ultrasonic technology, we strongly recommend you contact us regarding application and availability
before placing your order.
Ordering Information
Converters
Included in standard delivery: Converter, manual, pipe clamp kit
3-3350-1 GF Signet 3350 xed transit-time ow meter converter, 110 VAC input $ 1,475
3-3350-2 GF Signet 3350 xed transit-time ow meter converter, 220 VAC input 1,475
Detectors
Each detector kit includes: Detector unit, 5m signal cable pair, mounting straps, 3.5 oz tube sonic coupling compound (silicone grease)
3-3550.100 2 MHz detector set, 1.0 to 4.0 in. pipe dia., -4 to 212°F 724
3-3550.200 2 MHz detector set, 2.0 to 9.0 in. pipe dia., -4 to 212°F 749
Accessories
3-3550.075 Pair of 50 ohm signal cables, 5 meters 75
3-3550.076 Pair of 50 ohm signal cables, 10 meters 150
3-3550.077 Pair of 50 ohm signal cables, 15 meters 225
3-3550.078 Pair of 50 ohm signal cables, 20 meters 300
3-3550.079 Pair of 50 ohm signal cables, 30 meters 450
3-3800-1000 Sonic coupling compound 15
3-3800-1001 Sonic coupling compound, silicone-free 35
3-3800-1002 RTV Compound 15
Information subject to change without notice. Prices in USD. 021307
2