Georg Fischer 3-0252 Specifications

Signet 0252 Confi guration Tool
Features
• Back up and restore SmartPro® Transmitters and blind sensors confi gurations to a computer fi le
• User-friendly interface
• Confi gure settings such as instrument type, units, scale 4 to 20 current loops and modify labels from the computer
• Use a single fi le to clone multiple SmartPro® Transmitters and blind sensors
• Red and blue LED indicators for power and data
The new 0252 Confi guration Tool interfaces with Signet SmartPro® Transmitters and blind sensors, allowing fast and easy confi guration using a PC. The confi guration information can be saved to a fi le and stored on a PC to be used later on a replacement sensor or for another sensor in a similar application.
The saved confi guration fi le can be downloaded to the sensor or the SmartPro Transmitters in mere seconds.
The save and load features allow you to back up all of your settings and transfer them to future devices. You can also e-mail the fi les to share with other users of the 0252 software.
The 0252 will graph and data log sensors in real time for trend and troubleshooting analysis. Export data logs in coma-separated value (CSV) format for review and reporting in many popular spreadsheet and database applications.
Support for new sensors and products is as simple as connecting to the Internet. The software will automatically download updates from the Internet to ensure you have the latest version of the application.
Compatibility
• 9900 Transmitter
• 2250 Level Sensor
• 2350 Temperature Sensor
• 2450 Pressure Sensor
• 2551 Magmeter Flow Sensor
• 2552 Metal Magmeter Flow Sensor
• 2750 pH/ORP Sensor Electronics
• Windows XP, 32-bit
• Windows Vista
• Windows 7 (32 and 64-bit versions)
• Windows 8 and Windows 8.1 (32 and 64-bit versions)
• Windows 10 (32 and 64-bit versions)
®
The software is supported in the following languages: Chinese, English, French, German, Italian, Portuguese and Spanish.
Microsoft, Windows, and Windows Vista are registered trademarks of Microsoft Corporation in the United States and other countries.
2.76
1.06
.48
.52
.43
.87
Specifi cations
General
Materials ABS body Power Requirements Supplied by USB Interface
Windows XP, Windows Vista, Windows 7 (32 and 64 bit), Windows 8, 8.1,
System Requirements
and Windows 10 (32 and 64 bit), free USB port, administrator account for installation, Internet access required for automatic updates.
Inputs 3-wire (S
3
L) input
Output Specifi cations USB 1.0 or greater
Shipping Weight
0.220 kg 0.48 lb
Standards and Approvals
CE, FCC
RoHS compliant, China RoHS
Dimensions
.87
0.43”
11 mm
.48
0.48”
12.2 mm
.43
2.76”
2.76
70 mm
0.52”
.52
13.2 mm
0.87”
22 mm
1.06”
1.06
27 mm
System Overview
Modifi able Parameters (dependent on SmartPro
Instrument type or sensor to be confi gured)
• Instrument type
Units of measure
• Customer confi gurable tag (label)
4 to 20 mA span
4 to 20 mA error value
Relay and open collector modes
Bar graph span
Back light control
• LCD contrast
• Password
and other instrument and sensor specifi c settings
Blue LED indicates data transmission
+5 V out Data GND
Red LED indicates power
For wiring reference please see manual
Relay Modes (dependent on Instrument type) Low set point High set point Window In Window Out PWM Proportional Pulse Cycle Low Cycle High Volumetric Pulse Totalizer Error
sensor
Includes 2 m (6 ft) USB extension cable and 1 m (3 ft) SmartPro (9900) interface cable
Ordering Information
Mfr. Part No. Code Description
3-0252 159 001 808 Confi guration tool
Accessories and Replacement Parts
Mfr. Part No Code Description
3-0252.099 Rev A (1/16) © Georg Fischer Signet LLC 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057 • www.gfsignet.com • e-mail: signet.ps@georgfi scher.com Specifi cations subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.
6682-3004 159 001 725 Terminal block plug