Georg Fischer 2839-2842 Data sheet

Signet 2839-2842 Conductivity Electrodes
Features
• Dual-threaded
• Compact electrode length for easy in-line installation in small pipe sizes
• Triple orifice flow­through design
reduces clogging and
bubble entrapment
• 316SS electrodes with injection molded PEEK™ process con­nections and insula­tors
2841-1 2842-1
Description
The Signet 2839-2842 Conductivity/ Resistivity Electrodes are available in four cell constants from 0.01 to
-1
10.0 cm
, and are suitable for a wide variety of applications ranging from high purity water quality monitoring to weak acids and bases. 316SS elec­trode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and
System Overview
In-Line Installation
Panel Mount Pipe, Tank, Wall Mount Integral Mount
Signet Conductivity Instrument
(sold separately) 8850 8860 8900 5800CR
Signet 2839-2842 Conductivity Electrodes
Signet 8850 Conductivity Instrument
(sold separately)
Signet Universal Adapter Kit (3-8050)
(sold separately)
Signet 2839-2842 Conductivity Electrodes
Signet 8850 Conductivity Instrument
(sold separately)
Signet Integral Adapter Kit (3-8052)
(sold separately)
Signet 2839-2842 Conductivity Electrodes
2839-12840-1
repeatability. The PEEK™ insulator and process connections are injection over-molded to minimize variance between electrodes. Double threaded connections in either 3/4 in. NPT or ISO 7/1-R 3/4 enable quick and easy installation in submersible or in-line configurations. Transmitter integral mounting kit and junction boxes are available as accessories.
Multi-Parameter Panel Mount
Signet 8900 Instrument
(sold separately)
Signet 2850 In-Line Conductivity Sensor
(sold separately)
Signet 2839-2842 Conductivity Electrodes
4 to 20mA Input
Chart Recorder (sold separately)
Signet 2850 In-Line Conductivity Sensor
(sold separately)
Signet 2839-2842 Conductivity Electrodes
OR
Programable
Logic Controller
• Cell constants may be traceable to NIST and certified to within ±1% of value - meets USP requirements
Applications
• Water Treatment & Water Quality
Monitoring
• Reverse Osmosis
• Deionization
• Cooling tower and Boiler Protection
• Distillation
• Desalination
• Demineralizer
• Semiconductor
• Aquatic Animal Life Support Systems
Submersible Installation
Panel, Pipe, Tank, Wall Mount
Signet Conductivity Instrument 8850 8860 8900 5800CR
Pipe extension or conduit with 3/4 in. FNPT threads (customer supplied)
AND/OR
Signet 2850 Submersible Conductivity Sensor
Signet 2839-2842 Conductivity Electrodes
114
Fittings - Customer supplied, 3/4 in. NPT or ISO threaded
www.gfsignet.com
Specifications
General
Range:
• 2839:
0.055 to 100μS (18.2MΩ to 10KΩ) (0.02 to 50 ppm)
• 2840: 1 to 1,000μS (1MΩ to 1KΩ) (0.5 to 500 ppm)
• 2841: 10 to 10,000μS (5 to 5,000 ppm)
• 2842: 100 to 200,000μS (50 to 100,000 ppm) Accuracy: ±2% of cell constant value (standard). Cell constants can be traceable to
NIST and certified to within ±1% of value (contact factory)
Dual-threaded process connection:
• -1 versions: 3/4 in. NPT
• -1D versions: ISO 7/1-R3/4
Wetted Materials
• Internal O-ring (2841 and 2842): FPM
• Insulator material: PEEK™
• Electrode material: 316SS
• Threaded process connection: PEEK™
Max. Pressure/Temperature Ratings
Operating temperature/pressure:
• -10°C to 100°C @ 6.9 bar (14°F to 212°F @ 100 psi)
• -10°C to 131°C @ 2.76 bar (14°F to 268°F @ 40 psi) Storage temperature:
-20°C to 131°C (-4°F to 268°F)
See page Temperature and Pressure graphs for more information.
Shipping Weight
• 2839: 0.34 kg (0.74 lb)
• 2840, 2841, 2842: 0.30 kg (0.66 lb)
Choosing
Products
Instrument
Multi-Pa-
rameter
Flow
pH/ORP
Conductivity/
Resistivity
Cable:
• 4.6 m/15 ft, 3-cond. w/shield (standard)
• 30m/100 ft (maximum)
Temperature element: PT-1000 Temp. response, τ:
• 5 sec. (0.01 cell)
• 10 sec. (0.10 cell)
• 20 sec. (1.0 cell)
• 30 sec. (10.0 cell)
Temp. accuracy: ±0.5°C (±0.9°F)
Operating Range Chart
Bottled
UPW @ 25°C
USP
Rinse Water
3-2841
3-2840
Water
3-2842
Standards and Approvals
• CE
• Manufactured under ISO 9001:2000 for Quality and ISO 14001:2004 for Environmental Management
Cooling Tower
Waste Waters
(1.0 Cell)
(0.10 Cell)
Deionization Regen. Chemicals
Alkali Cleaners, Acids/Bases
Brackish
Sea Water
(Salinity)
(10.0 Cell)
Pressure, Level
Temperature,
Products
Other
Installation
Wiring &
Reference
Technical
Temperature/
Pressure
Graphs
www.gfsignet.com
3-2839 (0.01 Cell)
0.055µS
18.2MΩ
PPM TDS
1µS
1MΩ
10µS
100KΩ
550
100µS
10KΩ
1,000µS
500
10,000µS
5,000
50,000µS
25,000
100,000µS
200,000µS
50,000 100,000
400,000µS
200,000
115