Signet 2760 DryLoc® pH/ORP Preamplifi ers
(Not for new designs or installations)
Features
• In-line integral mount and submersible
installation versions
• Compatible with pH or ORP sensors
• Patented DryLoc® connector provides a quick
and secure connection to the sensor*
In-line
2760
DryLoc® Electrodes sold separately.
The Signet 2760 pH/ORP Preamplifiers feature a
DryLoc® connector, providing a robust connection to
Signet DryLoc electrodes.
The 2760 preamplifier allows DryLoc pH/ORP electrodes
to work with Signet ProcessPro® and ProPoint® pH/ORP
instruments.
The DryLoc electrode connector system quickly
forms a robust assembly for submersible and in-line
installations. Optional NEMA 4X junction enclosures
extend the preamplifier cable to long distances.
The 2760 submersible preamplifier can also be used as
an in-line preamplifier when used with the ¾ in. or
1 in. threaded sensors including the 2724, 2774 and
2764 series electrodes. The 2760 in-line preamplifier
can be used with Signet fittings up to DN100 (4 in.) and
Wet-Tap assemblies.
Submersible
2760
Applications
• Water/Wastewater Treatment
• Neutralization Systems
• Scrubber Control
• E uent Monitoring
• Surface Finishing
• Flocculent Coagulation
• Heavy Metal Removal and Recovery
• Toxic Destruction
• Sanitization Systems
• Pool & Spa Control
• Aquatic Animal Life Support Systems
The 2760 pH/ORP preamplifiers are compatible with the
Signet 8750 and older analog transmitters. The 8900
and 9900 instruments and Profibus Concentrator require
the use of the 2751 Smart Sensor Electronics, and are
not compatible with the 2760 preamplifier.
*U.S. Patent No.: 6,666,701

Specifi cations
General
Compatible Electrodes Signet DryLoc pH and ORP Electrodes Models 2724-2726, 2756-2757
Wet-Tap, 2764-2767, 2774-2777
All pH sensors used with the 2760/8750 must have a 3K Temperature sensor
Compatible Instruments 8750 and 5700
Operating Range pH 0 to 14 pH
ORP ±2,000 mV
Response Time* pH < 6 sec. for 95% of change
ORP application dependent
®
Materials In-line Valox
Submersible CPVC
Electrical
Cable 4.6 m (15 ft) supplied, 120 m (400 ft) max
6 cond., foil shield with drain wire, 24 AWG
Max. Temperature/Pressure Rating
Operating Temperature Submersible 0 °C to 85 °C 32 °F to 185 °F
In-line 0 °C to 110 °C 32 °F to 230 °F
Storage Temperature -20 °C to 85 °C -4 °F to 185 °F
Relative Humidity 0 to 95%, non-condensing (without electrode connected)
Environmental
Enclosure Submersible NEMA 6P/IP68 with electrode and watertight conduit and/or extension
In-line NEMA 4 with electrode and watertight conduit and/or extension
Shipping Weight
0.64 kg 1.41 lb
Standards and Approvals
CE, FCC
RoHS compliant, China RoHS
Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management
and OHSAS 18001 for Occupational Health and Safety
(PBT)
pipe connected
pipe connected
Dimensions
3-2760-1, -2
70.1mm
(2.76 in.)
www.gfsignet.com
31.75mm
(1.25 in.)
56.6mm
(2.23 in.)
3/4 in. ISO or
3/4 FNPT threads
89.4mm
(3.52 in.)
3-2760-11, -21
101 mm
(4.0 in.)
35.0 mm
(1.38 in.)
61.0 mm
(2.40 in.)
3/4 in. ISO or