Signet 2580 FlowtraMag® Meter
Features
• No moving parts
• Lighter in weight compared to traditional metal
magmeters
• Reduced straight run requirements, ideal for fi nal
e uent lines, wellheads and skids
• Factory calibrated with certifi cate
(±1% of reading accuracy)
• Partially fi lled pipe detection status indicator
(Smart Phone not included)
The GF Signet 2580 FlowtraMag is a full-bore plastic
PVC in line style magnetic fl owmeter. The PVC body with
titanium or Hastelloy® C electrodes has no moving parts,
and is two to three times lighter in weight compared
to traditional metal magmeters on the market. It is
designed for high accuracy fl ow measurement in short
pipe runs, making it an ideal solution for industrial
applications where performance and ease of use are
important.
The FlowtraMag design is factory calibrated with
certifi cate at ±1% of reading accuracy. It is o ered
in corrosion resistant materials to provide long-term
reliability with minimal maintenance costs. The LED
indicators show at-a-glance system status, including
normal operation, zero fl ow and partially fi lled pipe
detection.
The fl ow meter provides three di erent outputs;
fi eld selectable frequency or digital (S3L) as well as
analog 4 to 20 mA. The FlowtraMag is capable of
temperature readings of the media using the Signet 0252
Confi guration Tool or GF Confi g Tool Bluetooth® app.
The GF Confi g Tool Bluetooth® app supports iOS and
Android for simple on-the-fl y user confi guration.
These versatile, easy-to-install meters deliver accurate
fl ow measurement in pipe sizes of DN25 (1 in.),
DN50 (2 in.) and DN100 (4 in.), optimized for performance
in short pipe runs often associated with fi nal e uent
lines, well heads and water treatment skids.
• Visual LED indicators make sensor status clear and
easy to read
• Reverse fl ow direction confi gurable with
0252 Confi guration Tool or GF Confi g Tool
Bluetooth® App
• Capable of temperature readings of the
media using the 0252 Confi guration Tool
or GF Confi g Tool Bluetooth® App
• One device with three di erent outputs:
fi eld selectable Frequency or Digital (S³L),
and analog 4 to 20 mA
• On-the-fl y confi guration with GF Confi g Tool
Bluetooth® App
• Bluetooth® 4.2 capable, support iOS and Android for
simple user confi guration
(Titanium only)
Applications
• Chemical Processing/Production
• Cooling Tower
• Filtration Systems
• Water and Wastewater Treatment
• Municipal and Industrial Water Distribution
• Pool and Aquatics
• Process Control, Water Process Flow
• Reverse Osmosis
• Scrubber Systems
• Metal Recovery and Landfi ll Leachate
• Mining
U.S. and International Patents Pending
Hastelloy® is a registered trademark of Haynes International.
Specifi cations
General
Pipe Size Range DN25, DN50, DN100 1 in., 2 in., 4 in.
Flow Range Titanium or Hastelloy C 0.02 to 10 m/s 0.07 to 33 ft/s
DN25 (1") 0.53 LPM to 266.35 LPM 0.14 to 70.36 GPM
DN50 (2") 2.23 LPM to 1112.60 LPM 0.59 to 293.92 GPM
DN100 (4") 8.72 LPM to 4357.83 LPM 2.30 to 1151.22 GPM
Minimum Conductivity 20 μS/cm – water based
Power Cable Wire 7.6 m (25 ft) 2-conductor shielded
Output Cable Wire 7.6 m (25 ft) 5-conductor shielded
Cable wires may be extended up to 300 m (1000 ft), special order only
Wetted Materials
Flow Tube Body PVC
Electrode Titanium, grade 2 or Hastelloy C-276
O-rings FKM
Performance
Accuracy ± 1% of reading plus ± 0.01 m/s (0.033 ft/s), reference condition 50 μS/cm and water based
Repeatability ± 0.5% of reading @ 25 °C (77 °F)
Low Flow Cuto 0.02 m/s (0.07 ft/s) (adjustable via 0252 Confi guration Tool or GF Confi g Tool App)
Electrical
DC Power (Functional Rating) 24 VDC, max 24 W (12 to 32 VDC)
Reverse Polarity Protected Up to 35 VDC
Over-Voltage Maximum Rating 35 VDC
Current Output
Passive (low power) 4 to 20 mA per ANSI-ISA 50.00.01 Class H
Active Output 4 to 20 mA
Passive Loop Voltage 12 to 32 VDC
Loop Accuracy ±32 μA (@ 25 °C @ 24 VDC)
Loop Resolution 5 μA
Loop Span 3.8 mA to 21 mA
Error Condition None, 3.6 mA or 22 mA
Max. Cable 300 m (1000 ft)
Max. Loop Resistance 600 Ω @ 24 VDC
Compatible with PLC, PC or similar equipment
Frequency Output
Frequency 5 to 24 VDC, 50 mA max.
Frequency Range 0 to 1500 Hz
Max. Cable 300 m (1000 ft)
Max. Pull-up Voltage 30 VDC, 10k pull-up recommended
3
Digital (S
Digital (S3L) 4.5 to 5.5 VDC
Max. Cable Length Application dependent
Environmental Requirements
Enclosure NEMA 4X / IP65
Relative Humidity 0 to 95% non-condensing
Storage Temperature -10 °C to 60 °C (14 °F to 140 °F)
Operating Temperature
UL Environmental Rating UL 50, Type 6P Storage
Altitude 4,000 m 13,123 ft
Pressure/Temperature Ratings
Maximum Operating Pressure 10 bar @ 23 °C (145 psi @ 73 °F)
DN25 (1") and DN50 (2") 3.5 bar @ 60 °C (51 psi @ 140 °F)
DN100 (4") 2.27 bar @ 60 °C (33 psi @ 140 °F)
Shipping Weight -Titanium or Hastelloy C
DN25 (1") 3.4 kg 7.5 lbs
DN50 (2") 4.5 kg 9.9 lbs
DN100 (4") 8.3 kg 18.3 lbs
Standards and Approvals
L) Output
Ambient -10 °C to 60 °C 14 °F to 140 °F
Media 0 °C to 60 °C 32 °F to 140 °F
Compatible with Signet 8900, 9900, 9950, and 0486 Profi bus Concentrator
Serial ASCII, TTL level 9600 bps Compatible with Signet 8900, 9900, 9950 and 0486 Profi bus Concentrator
CE, FCC, NSF (Titanium only, does not include fl ange gaskets)
UL, CUL Recognized Component
RoHS compliant, China RoHS
Manufactured under ISO 9001 for Quality, ISO 14001 for Environmental Management and OHSAS 18001 for
Occupational Health and Safety.
www.gfsignet.com