Georg Fischer 2580 Specifications

Signet 2580 FlowtraMag® Meter
Features
No moving parts
Lighter in weight compared to traditional metal
magmeters
Reduced straight run requirements, ideal for fi nal e uent lines, wellheads and skids
Factory calibrated with certifi cate (±1% of reading accuracy)
Partially fi lled pipe detection status indicator
(Smart Phone not included)
The GF Signet 2580 FlowtraMag is a full-bore plastic PVC in line style magnetic fl owmeter. The PVC body with titanium or Hastelloy® C electrodes has no moving parts, and is two to three times lighter in weight compared to traditional metal magmeters on the market. It is designed for high accuracy fl ow measurement in short pipe runs, making it an ideal solution for industrial applications where performance and ease of use are important.
The FlowtraMag design is factory calibrated with certifi cate at ±1% of reading accuracy. It is o ered in corrosion resistant materials to provide long-term reliability with minimal maintenance costs. The LED indicators show at-a-glance system status, including normal operation, zero fl ow and partially fi lled pipe detection.
The fl ow meter provides three di erent outputs; fi eld selectable frequency or digital (S3L) as well as analog 4 to 20 mA. The FlowtraMag is capable of temperature readings of the media using the Signet 0252 Confi guration Tool or GF Confi g Tool Bluetooth® app. The GF Confi g Tool Bluetooth® app supports iOS and Android for simple on-the-fl y user confi guration.
These versatile, easy-to-install meters deliver accurate fl ow measurement in pipe sizes of DN25 (1 in.), DN50 (2 in.) and DN100 (4 in.), optimized for performance in short pipe runs often associated with fi nal e uent lines, well heads and water treatment skids.
Visual LED indicators make sensor status clear and easy to read
Reverse fl ow direction confi gurable with 0252 Confi guration Tool or GF Confi g Tool Bluetooth® App
Capable of temperature readings of the media using the 0252 Confi guration Tool or GF Confi g Tool Bluetooth® App
One device with three di erent outputs: fi eld selectable Frequency or Digital (S³L), and analog 4 to 20 mA
On-the-fl y confi guration with GF Confi g Tool Bluetooth® App
Bluetooth® 4.2 capable, support iOS and Android for simple user confi guration
(Titanium only)
Applications
Chemical Processing/Production
Cooling Tower
Filtration Systems
Water and Wastewater Treatment
Municipal and Industrial Water Distribution
Pool and Aquatics
Reverse Osmosis
Scrubber Systems
Metal Recovery and Landfi ll Leachate
Mining
U.S. and International Patents Pending
Hastelloy® is a registered trademark of Haynes International.
Specifi cations
General
Pipe Size Range DN25, DN50, DN100 1 in., 2 in., 4 in. Flow Range Titanium or Hastelloy C 0.02 to 10 m/s 0.07 to 33 ft/s DN25 (1") 0.53 LPM to 266.35 LPM 0.14 to 70.36 GPM
DN50 (2") 2.23 LPM to 1112.60 LPM 0.59 to 293.92 GPM
DN100 (4") 8.72 LPM to 4357.83 LPM 2.30 to 1151.22 GPM Minimum Conductivity 20 μS/cm – water based Power Cable Wire 7.6 m (25 ft) 2-conductor shielded Output Cable Wire 7.6 m (25 ft) 5-conductor shielded Cable wires may be extended up to 300 m (1000 ft), special order only
Wetted Materials
Flow Tube Body PVC Electrode Titanium, grade 2 or Hastelloy C-276 O-rings FKM
Performance
Accuracy ± 1% of reading plus ± 0.01 m/s (0.033 ft/s), reference condition 50 μS/cm and water based Repeatability ± 0.5% of reading @ 25 °C (77 °F)
Low Flow Cuto 0.02 m/s (0.07 ft/s) (adjustable via 0252 Confi guration Tool or GF Confi g Tool App)
Electrical
DC Power (Functional Rating) 24 VDC, max 24 W (12 to 32 VDC) Reverse Polarity Protected Up to 35 VDC Over-Voltage Maximum Rating 35 VDC
Current Output
Passive (low power) 4 to 20 mA per ANSI-ISA 50.00.01 Class H Active Output 4 to 20 mA Passive Loop Voltage 12 to 32 VDC Loop Accuracy ±32 μA (@ 25 °C @ 24 VDC) Loop Resolution 5 μA Loop Span 3.8 mA to 21 mA Error Condition None, 3.6 mA or 22 mA Max. Cable 300 m (1000 ft) Max. Loop Resistance 600 Ω @ 24 VDC
Compatible with PLC, PC or similar equipment
Frequency Output
Frequency 5 to 24 VDC, 50 mA max. Frequency Range 0 to 1500 Hz Max. Cable 300 m (1000 ft) Max. Pull-up Voltage 30 VDC, 10k pull-up recommended
3
Digital (S
Digital (S3L) 4.5 to 5.5 VDC
Max. Cable Length Application dependent
Environmental Requirements
Enclosure NEMA 4X / IP65 Relative Humidity 0 to 95% non-condensing Storage Temperature -10 °C to 60 °C (14 °F to 140 °F) Operating Temperature
UL Environmental Rating UL 50, Type 6P Storage Altitude 4,000 m 13,123 ft
Pressure/Temperature Ratings
Maximum Operating Pressure 10 bar @ 23 °C (145 psi @ 73 °F) DN25 (1") and DN50 (2") 3.5 bar @ 60 °C (51 psi @ 140 °F) DN100 (4") 2.27 bar @ 60 °C (33 psi @ 140 °F)
Shipping Weight -Titanium or Hastelloy C DN25 (1") 3.4 kg 7.5 lbs
DN50 (2") 4.5 kg 9.9 lbs DN100 (4") 8.3 kg 18.3 lbs
Standards and Approvals
L) Output
Ambient -10 °C to 60 °C 14 °F to 140 °F Media 0 °C to 60 °C 32 °F to 140 °F
Compatible with Signet 8900, 9900, 9950, and 0486 Profi bus Concentrator
Serial ASCII, TTL level 9600 bps Compatible with Signet 8900, 9900, 9950 and 0486 Profi bus Concentrator
CE, FCC, NSF (Titanium only, does not include fl ange gaskets) UL, CUL Recognized Component RoHS compliant, China RoHS Manufactured under ISO 9001 for Quality, ISO 14001 for Environmental Management and OHSAS 18001 for
Occupational Health and Safety.
www.gfsignet.com