2290 Non-contact Radar Level Transmitter
Features
• 19° beam angle
• Tank mapping function
• Large dot matrix LCD display
• Predefi nded tank shapes
• Works with fumes, condensation, and light
foam layers
PP
The 25 GHz (K-band) 2290 Pulse Radars are the most
progressive non-contact level transmitter technology for
industrial processes. With an excellent accuracy,
compact antennas and a user-friendly set-up the 2290 is
an e ective, simple, low cost choice for demanding level
applications. GF’s new K-band radar featuring ±3 mm
(±0.1inch) accuracy and short dead band excels with its
full plastic housing. Its antenna range incorporates a
stainless steel horn and enclosed plastic tube choices.
The enclosed antenna versions can be replaced without
removing the antenna enclosure from the process. Local
programming of type 2290 is aided by a plug-in display
module. The signal processing algorithm of the 2290 is
based on years of experience with non-contact level
measurement making it an excellent choice for
applications simple and challenging alike.
Applications
• Bulk Storage Tanks
• Day Tanks
• Process vessels for Mixing and Batching
• Bu er Tanks
• Conditioning vessels
• Metal or Plastic

Dimensions
135 mm (5.3 in.)
135 mm (5.3 in.)
139 mm (5.4 in.)
M20 x 1,5 (2x)
NPT 1/2" (2x)
Sw.55
22 mm (0.9 in.)
BSP 1 1/2"
NPT 1 1/2"
Ø44 mm (1.6 in.)
PP horn antenna
Lmin: 200 mm (7.9 inch)
172 mm (6.7 in.)
100 mm (3.9 in.)
118 mm (4.6 in.)
L
MIN
M20 x 1,5 (2x)
2 x NPT 1/2"
Sw.55
20 mm (0.8 in.)
Ø38 mm (1.2 in.)
M6/Sw.3
BSP 1½"
Stainless Steel 316 Ti horn antenna
Lmin: 200 mm (7.9 inch)
2
L
MIN
M20 x 1.5 (2x)
NPT ½” (2x)
133 mm (5.2 in.) 137 mm (5.4 in.)
Stainless Steel 316 Ti horn antenna &
temperature isolater
Ø100
Sw.55
226 mm (8.8 in.)
M6/Sw.3
20
Ø38
2 mm
133 mm (5.2 in.)
L
MIN
Lmin: 200 mm (7.9 inch)
Specifi cations
General
Measured Values Level, Distance; Calculated values: Volume, Mass
Wetted Parts Horn Anntenna Stainless Steel 316 Ti
Antenna enclosure PTFE, PP
Frequency of the Measuring Signal ~25 GHz (K-band)
Measuring Range 0.2 m – 18 m (0.65 – 59 ft) (depending on εr of the process liquid)
Accuracy ±3 mm (0.1 inch)
< 0.5 m:
0.5 – 1 m:
Linearity Error (as per EN 61298-2)
1 – 1.5 m:
1.5 – 8 m:
> 8 m:
Beam Angle Minimum 19°
Minimum dielectric constant εr of the
1.9 ( refer to range diagram below)
Medium
Resolution 1 mm (0.04 in.)
Temperature Error (as per EN 61298-3) 0.05% FSK / 10 °C (50 °F )
-20 °C… +60 °C (-68 °F… +140 °F)
Power Supply Voltage 20 V …36 V DC
Output Digital Communication 4 – 20 mA + HART
Output Display 64 x 128 Dot Matrix LCD Graphical display unit
Measuring Frequency 10…60 sec as per the application settings
Antenna Diameter 38 mm (1 ½”)
Antenna Material Horn: Stainless Steel; enclosure: PP, PTFE
Medium Process Temperature -30 °C… +100 °C (-22 °F - 212 °F), (up to 120 °C (248 °F) for max. 2 min);
with PP antenna enclosure: max.: 80 °C (176 °F)
2290 HT (high-temperature, SS316 horn antenna): -30°C ... +180°C (-22°F ... + 356°F)
Maximal Medium Pressure 25 bar at 120 °C (248 °F); with plastic antenna enclosure: 3 bar at 25 °C (77 °F)
Ambient Temperature -20 °C… +60 °C (-4 °F - 140 °F)
Process Connection DN 40 / 1 ½” BSP, 1 ½” NPT“ thread
Ingress Protection IP 67
Electrical Connection 2x M 20 x 1.5 cable glands + internal thread for 2x ½” NPT cable protective pipe,
cable outer diameter: Ø 7 … Ø 13 mm (0.3 … 0.5 inch), wire cross section: max.
1.5 mm
Electrical Protection Class III
Housing Material Plastic (/PBT)
Sealing FKM
Communication Certifi cations R&TTE, FCC
EX-Approvals ATEX (ia): II 1/2 G Ex ia IIB T6…T5 Ga/Gb
ICEX (ia): EX ia IIB T6…T5 Ga/Gb
CE, FCC
±25 mm (< 1.6 ft: ±0.9 inch);
±15 mm (1.6 – 3.2 ft: ±0.6 inch);
±10 mm (3.2 – 4.9 ft: ±0.4 inch);
±3 mm (4.9 – 26.3 ft: ±0.1 inch);
±0.04% (> 26.3 ft: ±0.04%) of the measured distance
2
(AWG 15), wire cross section: max. 1.5 mm
2
www.gfsignet.com