Genie 3681036666 User Manual 2

Page 1
Operation and Maintenance Manual
3681036666
GARAGE
TABLE OF CONTENTS
Warranty Information ................... 2
Safety Information ..................... 3
Safety Features ......................... 3
Important Installation Instructions ....... 3
Pre-lnstallation Checklist .............. 4-6
Adjustments .......................... 7-8
Programming the Remote Control ...... 8
Installing lightbulb and lens ............. 9
Troubleshooting Guide ............. 10-11
Parts Lists and Exploded Views ..... 12 -13
COMPLETE WiTH INTELLICODE ®
REMOTE CONTROL AND SERIESII
ELECTRONICS
For 7' 6" Doors. Extension Kit is available for 8' Doors Included Wall Control MUST be installed prior to Operation
of this Garage Door Operator. Safe-T-Beam ®Safety Reverse System Must be installed and
the Force Controls MUST be Properly Set to close door. This Equipment meets or exceeds all Federal, State and UL 325
Safety Requirements.
Having Difficulty? Need Help?
Please call us:1-800-35-GENIE (354-3643) www.geniecompany.com
Please have Model information ready when calling.
Page 2
THE GENIE COMPANY LiMiTED WARRANTY
What is covered?
Any defect in material and product workmanship from personal, normal
household usein accordance with the Owner's Manual. For how long?
MODEL2020LSeries... 10 yearson motor and 2 yearson all other parts.
Who gets the warranty?
This warranty islimited to the consumer who originally purchased the product.
Geographic scope:
This warranty applies only to units installed and operated within the country where they were purchased.
Limitations:
IMPLIEDWARRANTIES,INCLUDINGTHOSEOF FITNESSFORA PARTICULAR PURPOSEANDMERCHANTABILITY(AN UNWRITTENWARRANTYTHATTHE
PRODUCTISFITFORORDINARYUSE),ARELIMITEDTO ONEYEARFROMTHE DATEOFPURCHASE.GENIEWILL NOTPAY FOR:LOSSOFTIME;
INCONVENIENCE;LOSSOFUSEOFYOURGENIEPRODUCTORPROPERTY DAMAGECAUSEDBYYOURGENIEPRODUCTORITSFAILURETOWORK;ANY
SPECIAL,INCIDENTALORCONSEQUENTIALDAMAGES;OR ANYDAMAGES
RESULTINGFROMMISUSEORMODIFICATIONOFYOURGENIEPRODUCT.
Some states and provinces do not allow limitations on how long animplied warranty lastsor the exclusion of incidental or consequential damages, so the
above limitations or exclusions may not apply to you. This warranty isthe only one we will giveon your Genie product, and it sets
forth all our responsibilities regarding your Genieproduct.There are noother express warranties.
State and province rights: This warranty gives you specific legalrights, and you may also haveother rights which vary from state to state andprovince to
province.
How to get warranty service:
To obtain warranty servicefor your Genie product, you must provide proof of the date and place of purchaseof the product.
1.Do=it-Yourself-Service. Callthe GenieCustomer Servicetoll free at 1.800.354.3643to speak in
person to a trained Genie representative for assistancein diagnosing the problem and arranging to supply you with the required parts for do-it-
yourself repairs.Trained service representativesare available Monday-Friday, 8:00a.m.- 9:00 p.m., EasternTime, and on Saturday, 10:00a.m. to 7:00 p.m.,
EasternTime (subjectto holidays) You may alsoget the information you needat www.geniecompany.com.
2.Service From Authorized Dealers.
YoualsomayobtainwarrantyservicefromGenieauthorizeddealersbycallingthe GenieCustomerServiceat 1.800.354.3643or byvisitingwww.geniecompony.com
beforeschedulingwarrantyservice.If warrantyserviceisprovidedbyanauthorized
dealer,Geniewill provideallrequiredpartsunderwarrantyatnochargeto you,but thedealersareindependentbusinesspeopleandmayrenderabenchor servicecall
chargefortheir services.Geniewill notreimburseyouorotherwiseberesponsiblefor thosecharges.
Wesuggestthat youretainyouroriginalpackingmaterialintheeventwechoose to repairor replaceyour GenieProductand requestthat youshipit to us.Besureto
includeyourname,address,telephonenumber,proof ofdateand placeofpurchase andadescriptionofthe operatingproblem.After repairingorreplacing,yourGenie
product,wewillshipit toyourhomeatno costto youfor partsandlabor,butyouwill haveto payaminimumof $S.00forshippingand handlingcharges.
Yourchoiceof eitheroneofthe above-describedserviceoptionsisyourexclusive
remedyunderthiswarranty. What this warranty does not cover: Thiswarrantydoesnotcoverbatteries(whichareconsideredreplaceableparts),
installation,commercialuse,defectsresultingfromaccidents,damagewhileintransit
to our servicelocationordamageresultingfromalterations,misuseorabuse,lackof
propermaintenance,unauthorizedrepairormodificationoftheproduct,affixingof
anyattachmentnotprovidedwith theproduct, programmingofthe RemoteControl
Devices,Safe-T-Beam®adjustment/cleaning,staplesthrough wiring, pinchedor broken
wires,Carriagedisengaged,ForceControladjustments,door outof balance,broken springsorcables,poweroutages,useofextensioncords,missingordamagedpartson
discounted,clearanced,finalsaleor tapedcartons,phantomoperations(laborisnot coveredif Openerisfunctioning properlywhiletechnicianisin garage),fire,flood,or
actsofGod,orother failuretofollow theOwner'sManual.
Pleasenote the following information,soit is availableifyou needto call us.
DatePurchased / / SerialNumber*
Operator Model* Dealer Name
DealerAddress City
State / Zip
eeSerial Number is located on the Power Head, inside
the Light Cover.
WK YR P I'_
Serial/Mfg No.
NOTE
Pleasekeep original or photocopy of your salesreceipt
with this manual for future reference shouldservice
ever be required.
INCLUDED IN THIS PACKAGE
Manual 1)Warranty Information
2) Pre Installation Checklist to be reviewed prior to any assembly or installation
3) Necessary Adjustments
4) Programming Remote Devices
5) Maintenance and Troubleshooting
6) Parts Explosions
7) Accessory Order Form
8) Door Opener Association Safety and
Maintenance Brochure (DASMA)
9) Entrapment Warning Label- To be Adhered
in close proximity to wall control
Poster 1) Pictorial and step by step opener assembly
instructions
2) Pictorial and step by step opener installation
instructions
MARKED CLEARLY IN BOTH THE MANUAL
lAND POSTER ARE READ, UNDERSTOOD AND
FOLLOWED;
Visit Our Website at: www.geniecompany.com
FORANSWERS:CALL1.800.354.3643
SAVE THESE INSTRUCTIONS
2 For Help, call 1=800-3S-GENIE or visit www.geniecompany.com
Page 3
OVERVIEW OF POTENTIAL HAZARDS
Overhead doors arelarge,heavy objects that move with the help of springsunder high tension and electric motors. Sincemoving objects,springs
undertension, and electric motors cancauseinjuries, your safetyand the safety of others depend on you reading the information in this manual. Ifyou havequestions or do not understand the information presented, callTheGenie Company. or your local GenieDistributor.
In this section, and those that follow, the words Danger, Warning and Caution are used to emphasize important safety
information. The word:
DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage.
The word NOTE is used to indicate important steps to be followed or important considerations.
POTENTIAL HAZARD
MOVING DOOR
ELECTRICALSHOCK
Could result in death
HIGH SPRINGTENSION
EFFECT PREVENTION
WARNING: . Keep people clear of opening while door is moving.
Could result in death oDo Not allow children to play with the door operator.
or serious injury, oDo Not operate a door that jams or one that has a broken spring.
WARNING:
Could result in death
or serious injury.
WARNING:
or serious injury.
oTurn off power before removing operator cover. oWhen replacing cover, make sure wires are not pinched or near
moving parts.
oOperator must be properly grounded. . Do Not try to remove, repair or adjust springs or anything to
which door spring parts are fastened, such as, wood blocks, steel brackets, cables or other like items.
oRepairs and adjustments must be made by a trained door
system technician using proper tools and instructions.
MPORTANT INSTALLATION NSTRUCTIONS
WARN ING:
TO REDUCE THI RISK
OF SEVERE INJURY OR DEATH:
1 READAND FOLLOWALL SAFETY,INSTALLATIONAND OPERATION
INSTRUCTIONS.If you have any questions or do not understand
an instruction, call your authorized Genie installation professional.
2 Do Not install operator on an improperly balanced door. An
improperly balanced door could cause severe injury. Repairs and adjustments to cables, spring assembly, and other hardware must be made by a trained service person using proper tools
and instructions.
3 Remove all ropes, and disable all locks connected to the door
before installing operator.
4 Install door operator 7 feet or more above the floor. Mount the
emergency release knob 6 feet above the floor.
5 Do Not connect the operator to the source of power until
instructed to do so.
6 Locatethe control button:
Within s!ght of door.
At a minimum height of Sfeet, so small children cannot reach it.
Awayfrom all moving parts of the door.
7 Install the entrapment WARNING label next to the wall button or
console. Install the emergency releasetag on, or next to, the emergency release.
8 The operator must reverse when the door contacts a 1-1/2 inch
high object on the floor at the center of the doorway. This is
about the size ofa 2 x 4 board aid fat.
SAFETY FEATURES
Safe-T-Beam® (STB)Non-Contact Reversing System
Placesan invisiblebeam acrossdoor opening, that reversesthe door during down travel to the fully
open position if anything passesthrough beam.
Safe-T-Reverse® Contact Reversing System
Automatically stops and reversesa closing door within 2 secondsof contact with an object.
Safe-T-Stop® Timed Reversed System
Automatically opens a closing door, ifdoor does not close within 30seconds.
ForceGuard Control
Used to set the force required for opening and clos- ing door. Formaximum safety,set the minimum
force required to fully open and close door. Automatic Lighting System
Light bulbs up to 60 Watts max., used for safer entries and exits. The lights turn on when door
isactivated and automatically turn off 4.5 minutes later.
Manual Emergency Release
Allows the garage door to be opened or closed
manually for emergencies or maintenance.
For Help, {all 1-800-35-GENIE or visit www.geniecompany.com :3
Page 4
PRE=INSTALLATION CHECKLIST
This Opener includes parts and supplies needed to install in most garages and connect to most garage doors. There are many variations
of garagesand garage doors. A few additional parts and supplies may
be needed to install Opener into your garage and connect to your
garage door. While checking items listed below, note any additional items you will need.
Tools used in this section:
12% Tape Measure Pencil Ladder Level
C Checkdoor type. Makeanoteofwhetheritisasectionalora one-piece door for reference later (Figure 2).
SECTIONAL DOOR,TORSION SPRINGS SECTIONAL DOOR, EXTENSION SPRINGS
ONEPIECEDOOR,TRACKLESS
Header Area
Check following items before assembling Opener:
Checkcondition of vertical stilein center of door, and its connection to door's top and bottom beams. (Figure 1) A Ifdoor frame is nailed together and not a solid connection, door
frame must be bracedor reinforced before installing Opener. B If door is"lightweight" (madewith frame and skin - not solid),
door (including door frame) must be braced or reinforced before
installing Opener. C Adoor opener reinforcement bracket may alsobe needed to
connect garage door to Opener's Door Bracket. This Opener is designed for installation on a properly braced sectional door or
solidly braced one-piece door. D Contact your Genie FactoryAuthorized Dealeror dealer of your
garage door for any necessarybracing and a door opener reinforcement bracket (if needed) before proceeding.
E If you haveawooden door, measuredoor's thickness. If your door is lessthan 2" thick, brace door or useshorter Door Bracket LagScrews
(1/4" x 1-1/4"- not included)
AND BALANCE
A Raisedoor, check alignment and seeif it movesfreely (Figure 2).
Ifdoor appears out of alignment, binds, or does not move smoothly, contact aGenieFactory Authorized Dealer or dealer of your garage
door for repairsand adjustments to door mechanism. B Raisedoor to 3' - 4' above ground and carefully let go. Door
should staystationary. Slight movement isacceptable. More than slight movement meansdoor is out of balance. Contact a Genie
FactoryAuthorized Dealer or dealer of your garage door for repairsand adjustments to door mechanism.
....::::-:::::: KEEPFEET CLEAR OF DOOR
One-Piece Door
Figure 2 Checking door balance
Center Stile
Figure 1 Note Door Type
A Measuredoor height (floor to top of door) using a tape measure.
B This new Garage Door Opener isdesigned for doors up to and including 7' 6" tall. Ifdoor height is7' 6" or lesscontinue to CheckStep 4.
C Ifdoor height is8'-0", you need a RailExtension Kit.(Figure 3). (SeeAccessoriesOrder Form,Page 16). D Ifthe door height istaller than 8'-0",
the opener you purchased isthe Rail Extension for wrong version. Contact 8' door
Customer Service Representative
at 1-800-354-3643.
Figure 3 Rail Extension Kit
NOTE
The header is a heavily reinforced section of the wall just above the top of the garage door opening.
A Findvertical center line of door and header:
Closedoor.
Measuredoor width at top.
Marka point at center of door and on headerdirectly
above door. Draw a center lineto connect points.
B Find Header Bracketmounting height (Figure 4): (Do not attach Header Bracket).
Raisedoor, watching top edge of door and stop door when its edge reachesits highest point.
Measuredistance ("H") from top edge of door to floor.
- Forsectional doors,add 2-1/2" to "H". Mark a point
on center line. Bottom of Header Bracketwill be
installed here.
- Forone-piece doors, add 6" to "H". Markthis point on
center line. Bottom of Header Bracketwill be
installed here.
SECTIONAL DOOR
H÷2_J=2_......
ONE-PIECE DOOR
WARNING:
Ifyour door sticks, binds, or is out of balance, have it adjusted bya Genie Factory Authorized Dealer. Door springs,cables, pulleys,brackets and associatedhardware are under extreme
tension and cancause seriousinjury or death.
4
H
Figure 4 Find Highest Point of Travel
ForHelp,call 1-800-3S-GENIEorvisit www.geniecompany.com
Page 5
NOTE
For all types and styles of doors:
- If the ceiling in your garage isso low that there is not at least a 3" space above the Header Bracket mountingpoint, contact a Genie Factory
AuthorizedDealer.
Ifa door spring is in the way, place the Header Bracket above the spring. Do Not move the door spring.
WARNING:
Door springs are under extremely high tension and
shou d be handed ONLYby atrained professiona.
Perforated Straps
FINISHEDCEILINGS Locateceilingjoistsortrussesusing
astudfinderorsimilardevice.
Attach angle iron(not included) to joists or trusses through finish
material using LagScrews.
Figure 6B Mounting methods for open beam or finished ceilings
C Checkwall for a stud or a solid header at your mark: (If checking a finished wall, a stud finder may be helpful).
If location isabove Header,a 2"x 6" board must be
screwed to studs besideyour mark with at leasttwo Lag Screwsand Flat Washers(not provided).
Transferyour markto new mounting board.
Check ceiling or space above where Opener Power Head will be mounted (Figure 5): There must be a 120Volt grounded outlet or wiring box within 3 feet of Power Head.
Grounded outlet
1
(8' door)
Door Center Line
Figure S Check Power Head location
A The measurements above aretaken from the garage door centerline toward the rear of the garage.
B Find location of ceiling joist or truss above where Opener Power Head will beand estimate type and quantity of materials needed for your installation (Figure 6A & B).
MOUNTING EXAMPLES
Standard Straps
Extra wood required Perforated Angle
Iron
POWERSOURCE
A Checkthat there is a 15Amp 120 Volt grounded electrical outlet or grounded permanent wiring box (per building code)
within 3' of Opener Power Head(Figure S).
If not, an outlet or wiring box must be installed. Contact a licensed electrician for installation.
Ifbuilding codes require permanent wiring, Power Head must be partially disassembledto install appropriate
wiring in place of Power Cord. (SeeAssemblyand
Installation Poster.)
NOTE
Permanent wiring must be installed by a Licensed Electrician. Not all Genie Factory Authorized Dealers are
Licensed Electrician's. Contact someone who isa Licensed Electrician.
WARNING:
Do not use and extension cordi Extension cords Can cause
dangerous overheating COnditions:
Do NOt Use p0rtable generat0rs: This pr0duct isdesigned to operate on standard house current;
DoNot use alternate power supplies.
MOU_ lJ.......... n ......., ......NNTINGBRACKET LOCATIO
Check for wood garage frame, jamb, or masonry at mounting location (6" above floor) with attachment tabs facing away
from garage door (Figure 7).
A If you cannot mount Safe-T-Beam ®Mounting Bracket to wood frame:
. Concrete screws and concrete anchors (not included)
must be used to mount Brackets on masonry with attachment tabs facing away from garage door.
Safe-T-Beam®Mounting BracketExtensions may be used
(not included - available at Dealeror useorder form pg. 14.
Figure 6A
OPENCEILINGSStrapsand angle iron may attach directly to joists or trusses.
For Help, call 1=800=35=GENIEor visit www.geniecompany.com
I
Safe-T-Beam ®
Mounting Bracket@/_ / 6"
Figure 7 Mounting I floor
Safe-T-Bea _ ......
Components
_i_ / ...........: Topof
Bracket
_i _rr above
5
Page 6
A Tools(FigureS):
B Additional tools to make installation easier:
Slotted and phillips screw-driver bits
Stud finder
Sheet-metal cutting snips
Check that the garage door locks, rope, and T-Handles are removed from the garage door before starting the installation.
A If your garage does not have a separate entry door, it is highly recommended to install a Genie Emergency Release Kit
(GER-2). Emergency Release Kit lets you open the garage door
from outside if there is a power failure. (Please see Accessories
Order Form on page 14.)
Before going further, get any items and tools if needed
for your installation
Garagedoor frame reinforcement brackets, screws, bracing or reinforcement kits (dealer)
LagScrews(1-1/4") for a wood door lessthan 2" thick (store) Electricaloutlet and/or wiring (supplied by a licensed electrician) Sufficient angle iron or strapping for hanging Power Head(store) 60 Watt light bulbs (Rough service bulbs recommended)(store) GER-2EmergencyReleaseKit for entry during power failure (store) Wood for header, ceiling, and/or door braces(store)
Masonry fastenersfor Safe-T-Beam Bracket installation (store) Safe-T-Beam®Bracket Extensions(dealer) Masonry drill bit (store) Extension Kit (for 8' Garage Doors)(dealer)
®
Go to Assembly and Installation Poster for full Installation Instructions.
IMPORTANT
SAFETY INSTRUCTIONS
!LWARNING:
TO REDUCE THE RISK OF
SEVERE iNJURY OR DEATH
1 READANDFOLLOWALLINSTRUCTIONS. 2 Neverlet childrenoperateor playwith the DoorControls.Keep
theRemoteControlawayfrom Children.
3 Alwayskeepthe movingdoor insightand awayfrom peopleand
objectsuntil the door iscompletelyclosed. NOONESHOULDCROSSTHEPATHOFA MOVINGDOOR.
4 NEVERGOUNDERA STOPPED,PARTIALLYOPENDOOR. 5 TestOpenermonthly. The,door MUSTreverseon contactwith
a 1-1/2 highobject (ora 2 x4 boardlaidflat)atthe centerofthe doorwayonthe floor. Afteradjustingeitherthe Forceorthe Limit oftravel,retestthe DoorOpener Failureto adjustthe Opener properlymaycausesevereinjuryordeath.
6 Whenpossibleusethe EmergencyReleaseony whenthedoor
isclosed. Usecautionwhen usingthis Releasewith dooropen. Weakor brokenspringsarecapableof increasingthe rateof door closureand increasingthe riskof severeinjuryordeath,
7 KEEPGARAGEDOORSPROPERLYBALANCED.SeeOwner's
Manual.An improperlybalanceddoor increasesthe riskof severe injuryordeath. HaveaGenieFactoryAuthorizedDealermake
repairsto cables,springassemblies,andother hardware,
8 SAVETHESEINSTRUCTIONS.
NOTES, REMINDERS
Adjustable Wrench
6
1t16" 5/32" Tape Measure'_
Drill Bit Drill Bit
Wire
Stripper
Hammer
Hack Saw
Figure 8 Recommended Tools
Safety Glasses
Wrench
Carpenter's Level
Phillips Screwdriver
Flat Blade Screwdriver
CF i_ ::: :: ....................
Pencil
1/4" 5/I6" 3/8" 7/16" 1/2" 9/16"
Sockets
AWARNING
use the Wall Console induded_ith opener:Any, other wall console can causethe Opener to operate unexPectedly and the light to stop working. 1
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Page 7
_DJUSTMENTS
SET LIMIT SWITCHES AND
FORCECONTROLS
Coarse Setting of Limit Switches
A Setting Close Limit Switch
. Check that Carriage Assembly is disengaged. . With garage door fully closed, slide Close Limit Switch
until it is aligned with the center of the Carriage Assembly.
. Tighten Set Screw. Do Not over-tighten.
B Setting Open Limit Switch
. Manually open garage door to full open position. . Slide Open Limit Switch until it is aligned with the center
of the Carriage Assembly.
. Tighten Set Screw. Do not over-tighten. . Re-engage Carriage Assembly.
Setting Force Controls and Final Adjustment of Limit Switches
i, Thegarage door opens rapidlyi and Cancause serious
: injury or deathl ; Keep the path Clear:
' Position the ladde[ to the Side of the Power Head Soit iS
Clearofall moving parts ofthe Opener and the door, Set the dooi Opener to use the minimum force needed
to open the door.
CLOSEADJUSTMENT
A
o
On front panel of Power Head find adjusting screw
marked "CLOSE" (Figure 9).
Gently turn screw counterclockwise until it stops.
- Very little force is required to turn adjusting screw.
Press Wall Console to close garage door.
- Observe if door stops at "CLOSE" limit switch. If door is fully closed--adjustment isfinished. Go to "OPEN" Adjustment.
- If door stops but is not fully closed, a. Measure distance between bottom of door
and floor.
b. Move "CLOSE" Limit Switch that same distance
toward door.
- If door stops and/or reverses before reaching the "CLOSE" Limit Switch
a. Slightly increase CLOSEForce setting (clockwise).
- If door reverses after contacting floor, move Limit Switch toward Power Head.
- If door fails to move, check Safe-T-Beam ®System. See
Troubleshooting Section, pages 10 and 11.
NOTE
Little effort isrequiredto turn the ForceAdjusting Knobs.
Ifthe door stops moving while opening or closing,adjust the Open Forceor CloseForceControlsslightly clockwise(to slightlyincreasethe force) and retry the step.
TheOpen Forceand CloseForceControlsareto be setto the
minimum force necessaryto ensurethe door smoothly opens and closescompletely.
Ensurethe CarriageAssemblyisengaged and isbetween the
two Limit Switches beforeoperating the Opener.
Thegaraged0oi Opensrapidly;andcan causeSeiOus
injury Ordeath:
Keepthepath clear: Positionthe ladder to the sideOfthe Power Headso it
is earof al!mo_ing parts of the Opener and the door i; Set the door opener to usethe minimum force needed
to open the door:
IB OPEN ADJUSTMENT
On front panel of Power Head find adjusting screw marked "OPEN" (Figure 9).
Gently turn screw counterclockwise until it stops.
- Very little force isrequired to turn adjusting screw.
Press Wall Console to open garage door.
- Observe if door stops at "OPEN" limit switch. If door isfully open--adjustment is finished.
- If door stops but isnot fully open, a. Measure distance between bottom of
door and top of door opening.
b. Move"OPEN" Limit Switch that same
distance toward Power Head.
- If door stops before reaching the "OPEN" Limit Switch
a. Slightly increase OPEN Force
setting (clockwise).
- If door fails to move, see Troubleshooting Section, pages 10 & 11.
C Run Door Opener
Cycle opener a few times to double check
settings. Repeat adjustment steps as necessary.
OPEN
FORCE ...
LOCATED UNDER
LIGHT
COVER
CLOSE /
FORCE
CLASS 2 SUPPLY 18-30 VOLTS
Figure 9 Making Force Adjustments (Located Lower Right Corner).
For Help, call 1-800-35=GENIE or visit www.geniecompany.com 7
Page 8
SETTING CONTACT
REVERSEFUNCTION
NOTE
Limit Switch and ForceAdjustments must be completed before checkingthe contact reversefunction.
A Open garage door using Wall Console.
B Lay a 2" x 4" board flat in center of doorway (Figure 10).
C Close door using Wall Console.
D Check that door stops and reverses within 2 seconds after it
contacts board:
If door does not reverse, decrease Close Force until door reverses (Figure 9).
If door still does not reverse, move Limit Switch toward door.
E Check Safe-T-Beam ®System operation:
If beam isblocked, door will not close.
Figure 10 F Checking _J
Contact Reverse
/J_-_ laid flat
2" x 4" board
NOTE
The door must contact the 2" x 4" board before the
Carriage activates the Close Limit Switch. If not, readjust the Close Limit Switch.
ACCESSORIES
PROGRAMMING THE
REMOTE CONTROL
A To program one Button of a Remote Control (Figure 11):
Locate Learn Button and Learn Indicator Light near
Terminal Block on Power Head (Figure 12).
Press and release Learn Button. Red Learn Indicator Light will blink 2 times per second.
Press Remote Control Button once within 30 seconds. Red Learn Indicator Light will stay lit.
Press Remote Control Button again. Red Learn Indicator Light will go out, indicating that memory is stored.
Press again to Activate Unit.
B Program each additional Remote using step A above.
To Erase All Remotes from Power Head Memory
A Press and hold Learn Button on Power Head for 10 seconds
or until Learn Indicator Light goes out. Memory is erased:
Program Remotes again as needed.
To Replace Remote Control Battery
A FOR NON-FLASHLIGHTMODELS
Pop off the back of the transmitter.
- Use coin, pen, screwdriver or any similar device.
- Replace old Battery with new coin type battery.
o Replace back of remote.
B FOR FLASHLIGHT MODELS
Slide open battery cover.
- Replace old Battery with new AAA battery.
o Replace battery cover.
A WARNING
Amoving garagedoor maycauseserious njuryor death.
--_ Keeppeopleclearof openingwhile door ismoving. Donot allowchildrento playwith the RemoteControls,
Ifthe SafetyReversedoesnot work properly:
" Closethedoor anddisconnecttheOpenerusingthe
EmergencyReleaseCord.
, Donot usethedoor Opener,RemoteControls,or
WirelessKeypad.
Referto the door anddoor 0 penerOwner'sManuals beforeattempting anyrepairs.
Remote Control Operation
A
PressButton on Remote Control. Garage door will move.
B
Press Button again. Garage door will stop:
The door automatically stops at the end of the
open or close cycle.
Press Button again. Garage door will reverse.
Figure 11
1-Button and 3-Button Compact Remotes w/Docking Station
D There are several additional varieties of remote controls available from your local dealer, some equipped with
a flashlight.
_b
©
....@(h
CLOSE@ MOREFORCE
LOCATED UNDERTHE LIGHT COVER
Figure 12 Learn Code Button and Indicator Light. (Located Lower Right Corner).
©
LEARN
INDICATOR
_-- LIGHT
---- LEARN
CODE
BUTTON
NOTE
e
Each Remote Control must be programmed separately.
The Remote Controls will not close the garage with malfunctioning Safe-T-Beam®System.
Program Remote Controls, while at least 24" from Antenna Wire.
If the red Learn Indicator Light blinks rapidly, programming stopped. Restart programming.
Each Button on a multi-button Remote Control is for a different Opener. Cannot use more than one
Button for same Opener.
A maximum of seven Remote Controls or Wireless Keypads can be stored into the Receiver at one
time. If a Remote Control becomes lost, or if you want to delete a Remote Control or Wireless
Keypad, see "To EraseAll Receiver Memory."
8 For Help, call 1-800-3S-GENIE or visit www.geniecompany.com
Page 9
iNSTALLATiON OF LENSAND BULB
A Install a light bulb (1O0Watts or less)(not included) into Light
Socket (Figure 14):
Rough service, 130 Volt bulbs are recommended.
B Install Lens into slots in Motor Cover.
Insert Bottom hinges into slots provided inmetal front
cover of Power Head.
Flip Lensup and fasten with molded latches on lens.
Transmitter Compliance Statement
Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture No warranty is made that they comply with all legal requirements of any other jurisdiction.If transmitters are to be used in another country, the importer must
determine compliance with any local laws and regulations which may differ from United
States and Canadian requirements prior to use. Los transmisores cumplen con todas las reglamentaciones [egales de los Estados Unidos y
del Canad&, en [a fecha de fabricaci6n. Ninguna garantfa se da que cumplan con todas as reglamentaciones legales de ninguna otra jurisdicci6n. Si los transmisores se van a utilizar
en otro pals, el importador debe determinar si cumplen con las reglamentaciones y [eyes
locales que puedan ser diferentes a las reglamentaciones de los Estados Unidos y del Canad& antes de usar los mismos.
Les emetteurs sont conformes _ la reglementation am_ricaine et canadienne _ compter de leur date de fabrication. Aucune garantie n'est stipul6e indiquant qu'ils sont conformes
routes [es prescriptions juridiques d'autres autorit_s. Si les _metteurs sont utilis_s dans
d'autres pays, i[ incombe a I'importateur d'en d_terminer leur conformit_ aux lois et
regles locales pouvant diff_rer de celes des Etats-Unis et du Canada avant toute utilisation desdits _metteur£
Sendeger_ite entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung,Wir Obernehmen keine Gew_ihrleistung for die Einhaltung aller
gesetzlichen Bestimmungen in anderen Lindem. Sollen Sendegerite in anderen L_ndem
eingesetzt werden, so muss der Importeur vor dem Gebrauch sicherstellen, dass die Sendeger_te auch solchen Iokalen Bestimmungen entsprechen, wekhe yon den
Bestimmungen der USA und Kanadas abweichen.
nlF+-t iOl 71El Ef-_--_ xlgqlAt +,"-f&_-I _-,'q:>- _-_°_;q_i,q_SFTlO_l o_,,ti _lq_t _HI-F.F_P--IS_
F&_,_I _l-@_Cl_____ :::z _Cl c" I _'_f __allOtl [qe-l-oi: _;q°l o:i _ z_oHof
NOTES
Figure 14 Install Lens and Light bulb
IMPORTANTSAFETYINSTRUCTIONS
WARNING--
TO REDUCE THE RISK OF
SEVEREINJURY OR DEATH
1 READAND FOLLOWALLINSTRUCTIONS. 2 Never let children operate or play w th the Doo_
Controls. Keepthe Remote Control away from children.
3 Always keep the moving door in sight and away from
people and objects until the door iscompletely closed. NO ONESHOULD CROSSTHE PATH OFTHE
MOVING DOOR.
4 NEVERGO UNDERA STOPPED,PARTIALLY
OPENDOOR.
5 Test Opener monthly,. The door MUST reverse on
contact with a 1-1/2 high object (ora 2 x 4 board laid flat) at the center of the doorway on the floor. After adjusting either the Forceor the Limit of travel, retest the Door Opener. Failureto adjust the Opener properly may causesevere injury or death,
8 When possibleusetheEmergencyReleaseonlywhen
the door isc osed. Usecaution when using this Reease
with thedooropen. Weakorbrokenspringsarecapable ofincreasingthe rateof doorclosureandincreasingthe riskofsevereinjuryordeath.
7 KEEPGARAGEDOORS PROPERLYBALANCED. See
Owner's Manual. An improperly balanced door increases the risk of severe injuryor death. Havea Genie Factory Authorized Dealermake repairs to cables,spring
assemblies,and other hardware.
8 SAVETHESEINSTRUCTIONS.
For Help, call 1-800-3S-GENIE or visit www.genie¢ompany.com
Page 10
SCHEDULED MAINTENANCE
A
Monthly:
o
Door springs and door hardware:
- Oil door roller, bearings, and hinges using silicone lubricant or light oil.
Reattach Carriage Assembly to Rail Assembly: a. Pull the Emergency Release Knobtoward
Power Head.
b. Close door.
Contact Reverse Test,
- Perform Adjustment Step 2 on page 8.
A WARNIN J
--Do not operate door auto atiCally 0r man_al/y if Springs are broken, Contact aGenie Fact0ry Authorized Dealerfor
service or call Customer Service at 1,800,35'GENIE. !
Balance Door.
- Close door.
- ReleaseCarriage Assembly from Rail Assembly by pulling down on Emergency ReleaseKnob.
- Raisedoor manually 3'- 4' and verify that door stays at that position. See Check Step 2 on page 4.
NOTE
When the door is3'- 4' above the ground, the door should stay open. Slight movement isacceptable. If
the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at
1=800=35=GENIE.
AWARNING
Ifthe door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 9. If the Opener still fails, contact a Genie Factory Authorized Dealer for service
or call Customer Service at 1-800-35-GENIE.
FCCAND IC CERTIFIED
All devices comply with Part 15 of the FCCRules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,and (2) this device must accept any interference received, includ- ing interference that may cause undesired operation.
B As Needed:
Replace Light Bulb
TROUBLESHOOTING GUIDE
Safe=T=Beam ® System Self=Diagnostic Troubleshooting
Source (Red LED)
ON OFF
OFF
2 BLINKS, Pause (Repeat)
2 BLINKS, Pause (Repeat)
3 BLINKS, Pause (Repeat)
4 BLINKS, Pause (Repeat)
Sensor (Green LED)
ON
OFF
ON
ON
OFF
ON
ON
Normal operation o Power Head not powered
oWiring from Power Head bad
o Wiring to Source missing or bad o Power has been interrupted
o Beam not aligned o Beam obstructed
o Sensor defective
o Wire to Sensor missing or bad o Sensor defective
o Sensor receiving interference
. Source not sending pulses . Source defective
Possible Problem
Solution
None required
. Check breakers, fuses, plugs . Check wiring for obvious shorts
. Check wiring . Remove power and reapply
. Check Source, Sensor alignment . Check for obstruction
. Contact Customer Service
o Check wiring o Contact Customer Service
o Determine source of interference o Check for sunlight or another
opener on nearby door
. Contact Customer Service o Contact Customer Service
. Contact Customer Service
10 For Help, call 1=800-35-GENIE or visit www.geniecompany.com
Page 11
Problem
Openerdoesnot run from WallControl
Door Opener starts for no apparent reason
Door starts down, then stops before it is completely closed
Door starts down, then stops and goes back up
Door will only run closed
Doorwill onlyrunopen
Lightswill not turn off
Doorstartsup, but stopsbeforeit is completelyopen
Operator runs,but door doesnot move
WallConsoleVacation Lockfunction does not work
Noisy Operation
General Troubleshooting
What To Do
1. Check Lock switch on Wall Control Installation Poster.
2. Check Power Source:
For Grounded Plug Connection.
- Plug a lamp into the electrical outlet used for the door opener. a. If lamp lights, power source is good. b. If lamp does not light, check fuse or circuit breaker.
For Permanent Wiring Connection.
- Check fuse or circuit breaker.
3. Check connections (seeWall Console Installation on Installation Poster):
At Power Head Terminals and Wall Control.
1. Check Wires to ensure that they are not cut (Staples can cut insulation and short Wires) Replace any shorting Staples and shorted Wires.
2. Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver's memory and reprogram for remaining remote controls. (See EraseAll Receiver Memory on page 8).
3. Ensure that no Buttons are stuck "pushed-in" on Wall Console or any Remote Controls.
1. Check Close Limit Switch setting (page 7and poster). Adjust as needed.
2. Check Force Setting (pages 7).Adjust asneeded.
3. Check for shorted wires.
1. Ifa new installation, check Door Arm position.
2. Check operation of Contact Reversefunction.
3. Check Safe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.
4. Check Safe-T-Beam®System diagnostic code.
5. Check CloseForceadjustment (seeSet Limit Switchesand ForceControlson pages7). Adjust as needed.
6. Check garage door for binding.
1. CheckOpen Limit Switch for ashort circuit and for proper wiring.
2. Check Open Force adjustment (seeSetLimit Switches and ForceControls on pages 7). Adjust asneeded.
3. Check condition of garage door and door spring(s).
4. WARNING: If you suspecta problem with the garage door hardware or springs,contact a Genie
FactoryAuthorized Dealer for service,or contact Customer Serviceat 1-800-35-GENIE.
5. CheckPosition of Lock Switchon Console.
1. CheckSafe-T-Beam®Systemasdetailed in the Safe-T-Beam®System Self-diagnosticTroubleshooting Chart (page 10).
2. CheckCloseLimit Switch for a short circuitand for proper wiring.
3. CheckCloseForceadjustment (seeSet Limit Switchesand Force Controlson pages7). Adjust asneeded.
1. Disconnect Wires connectingPushbutton to Power Head(seePushbutton Installation on poster). Checktheir conditionand either replaceor reconnect.
2. Until a replacement WallConsolecanbe obtained, disconnectWall Consoleand useonly Remote Controls or WirelessKeypadto operate Opener.
3. Check for non-compatible wall control.
1. Check(ensure) that garage door and Opener are in good repair, properly lubricated, and properly balanced as detailed in Maintenance Section.
2. WARNING: If you suspecta problem with the garage door hardware or springs,contact a Genie Factory
Authorized Dealerfor service,orcontact Customer Serviceat 1-800-3S-GENIE.
3. CheckOpen Limit Switch for a short circuitand for proper wiring.
4. CheckOpen Forceadjustment (seeSetLimit Switchesand ForceControlson pages7). Adjust as needed.
1. EnsureCarriageAssembly isengaged to CarriageSlide(seeInstallCarriageAssemblyontoRailsonInstallationPoster).
2. CheckForceadjustment (seeSet Limit Switchesand Force Controlson pages9and 10). Adjust asneeded.
1. EnsureCarriageAssemblyis in contactwith CloseLimit Switch.
2. Checkwhen door isfully closed,that CarriageactivatesCloseLimit Switch. Ifnot, adjust position of Close Limit Switch (Seepages7).
1. Besureall fastenersare tight.
2. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly balanced as described in Maintenance Section (page 10).
For Help, call 1-800-35-GENIE or visit www.geniecompany.com 11
Page 12
PARTS iDENTIFICATION
Power Parts _.auded
[1]Power Head Assembly Item Part Name
.1 Power Head Assembly 1
* 1A Cover (by Series Model) 1 * 1B Front Panel Assembly 1
* 1D Motor Parts 1 * 1E Circuit Board Assembhz 1
* 1F Capacitor (By Series/Model) 1
1G Opto Wheel (not shown) 1
* 1H Carriage Slide 1 * 1J Chain 1
1K Circuit Board Bracket 1 * 1L Drive Module 1 * 1M Terminal Strip 1
* 1N No. 8-32 x 3/4" Hex Head Screw
1P Shock Absorption Stop 1 * 1Q Motor Mount Bracket (not shown', 1
1X Chassis 1
4 1/4-20 Shoulder Bolt 1
5 1/4" Flange Nut 1
39 Coupler 1
41 No. 8-32 x 3/8" Phillips
42 No. 8-32 x 3/8" Phillips
48 Mountinq Straps 2 49 Light Lens 1
* Pre-assembled
Head List Number
w/int. Lockwasher 1
Hex Head Screw 1
Pan Head Screw 1
WIRING DIAGFIAM [ A Shut 0ff Cower bef0re 0penilg the cdver:[Components inside Cover May Cause Electric Shock J
, M°L°R.
I I
, _,_
I THERMAL _ _i:Y I [ ] PROTECTOR [ "_ ,,,,,(::_ i [
BLACK ' _ _'_/ I _ MOTOR
RED
2
ORANGE
J
YELLOW YELLOW
i I
;RED YELLOW',
i j
POWER CORD
z
POWERHEAD TERMINALS
WALLCONTROL
/_7 _
®®®o6®®®@®®®
SEQUENCER HOUSING
WHITE BLUE
LIGHT
OPENLIMIT
COMMON
CLOSELIMIT
IIM] SWITCH
OPIN
(JO'l
[_. LMIT SWTCH
12 For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Page 13
PARTS iDENTIFICATION
[2]RailAssembly
\
Parts List
item Part Name
1 PowerHead Assembly (main box) 2 RailAssembly (1-piece)
4 RailAssembly_3:piece)(main box)
5 First RailSection (separate box)
6 Middle RailSection (separate box)
7 End Railsection (separate box)
8 RailClamps (blue bag)
9 1/4"-20x 5/8" HexHead Bolt (blue bag) 10 1/4"-20" Hex Flange Nut (blue bag) 11 Carriage Assembly (main bag)
12 RailStrap (blue bag) 13 Limit Switch (white wire)(blue bag)
14 Limit Switch (brown wire)(blue bag) 15 ReleaseCord(green bag)
16 ReleaseKnob (green bag) 17 Emergency ReleaseTag (green bag)
18 HeaderBracket orange bag) 20 Door Bracket (orange bag)
22 1/4" x2" LagScrew(orange bag) 23 Straight Door Arm (mainbox) 24 ClevisPin (yellow bag)
25 Cotter Pin (yellow bag) 26 Curved Door Arm (main box)
27 3/8"-16 x 7/8" H.H.Bolt (yellow bag) 28 3/8"-16 Hex Nan e Nut ( ellow ba )
29 Wire (main box) 30 Insulated Staples(red bag)
m
1
I I I
I
4
12 12
I I
I I
I I I I I
8
I 2 2
I 2
2
I
variesby
model
Parts List
item Part Name
31 Wall Button (red bag) 32 Wall Console (main box)
33 #6x 1-1/4" pan head phillips screw
34 Entrapment Warning Label (manual) 35 Safe-T-Beam®Sensor (main box)
36 Safe-T-Beam®Source (main box) 37 Safe-T-BeaM®Mountinq Brackets 38 Remote Controls (main box)
39 #8-32x 1"Machine Screw (green bag)
40 Safetyand Maintenance Guide (manual) 41 Wire Clips
42 1/4"-20 x 3/4" Self-drilling Screws
(orange bag)
44 #10-16x 1-1/4" Phillips Hex Head Screw
(yellow bag)
46 5/16"-18 x 3/4"Hex Head Bolt
(orange bag) 47 5/16"-18 Hex Flange Nut (orange bag) 48 Mounting Straps (main box)
m
variesby
model
varies by
model
variesby
model
1 1 1 2
variesby
model
2
1
variesby
model
3
4
3 4 2
For Help, call 1-800-3S-GENIE or visit www.geniecompany.com 13
Page 14
GarageDoorOpenerAccessoriesOrder Form
Formulairedecommandodesaccessoirespourouvre-porte de garage
For additional accessories not shown, visit our website at www.geniecompany.com pour lesaccessoires suppl4mentaires pas montr4, visiter notr_ site web _ www.geniecompany.com
How many?
Comment beaucoup?
(GKT-1-390) 1-ButtonCompactRemote-Allowsremoteoperationofgaragedoor.
1-BoutennerT_l_cornrnaadecornpacte- Permettreoperation_loign"deportedegarage.
P/N 36248R 536.50
(GiFT-I-390) 1-ButtonFlashlightTransmitter-RemoteControllerwithaFlashlight.
1-houtenner['_rnetteurde[arnpedepoche- Lecontr61eur_loign_avecdelampedepoche.
P/N 35657R 545.00
{GICT-3-390)3-Bu_enCornpactBernete-AIIowsremoteoperationof3garagedoors.
3=boutennerlaT_l_cornrnandecornpacte- Permettreoperation_loign'
troisportes de ara e. P/N 36223R 550.00
(GWC-2W) Deluxe Wall Console - OperatesGarageDoor.Independentlightcontrol. Securityvacationlock.
LaConsole dseluxe deMur- Actionne la porte degarage.Commanded'_clairageind_pendante. Interrupteurde verrouillagede s_curit&
P/N 35661R 535.00
(GWKPD)DualFrequencyWirelessKeypad-OperatesIntellicode'GarageDoorOpenerswithoutRemoteControl
orkey. Syst_rned'ouvre-pertedegarage_ claviersansfil- Actionnelesouvre-portedegarageavec
Intellicode'sanst_l_commandenicl&
(GLU-3)
(Gw-2)
(6PS-5)
(GABXS)
P/N 35691 R
3/4 oz. ScrewDrive Lubricant-Ensuresproperequipmentwearprotection. Laonza3/4 Lubricantdela vis-Garantircomponantexactparsyst_med_fenseversuser.
P/N 35218AS
UniversalWall Button- Providesadditionalconvenientinsideoperationof door. Bouten mural universal - ActionneI'ouvre-portede I'int_rieurdu garage.
P/N 35693R 53.75
PerfectStep- Ensuresperfectparking. Butoir PerfectStop- Permetde stationner_ laperfectiondanslegarage.
P/N 35677R 54.00
BeltDriveExtensionKit-AnExtensionthatincreasesthe travelofabeltdrivenOpenerto
550.00
accommodateaneightfootdoor. N_cessairede prolongernentducoulisseau-Rallongedeprolongeantlacoursederouvre-porte
BeltDrivepouruneportede2,4m(8pi)dehauteur.
P/N 35663R
(LCGX-8) Chain Drive ExtensionKit- An Extensionthatincreasesthe travelof a ChainDrivenOpenerto
accommodateaneight foot door. N@cessairede prolongernent ducoulisseau -Rallongedeprolongeantlacoursederouvre-porte
du conduit dechainpourune portede2,4 m (8pi) dehauteur.
P/N 35679R 532.00
(GSX-8) ScrewDriven Extension Kit - AnExtensionto increasetravel of ascrewdriven Operatorto accommodate
an eight foot door.
coursedeI'ouvre-portepourune portede 2,4m (8 pi) de hauteur.(GIRU-lT) _-e_
N_cessairede taffonge du Screw Drive- Rallongedeprolongeant la
P/N 35678R
532.00
532.00
(60WATT)Enhanced/RoughServiceLightBulb-Ensuresproperequipmentcompatability.
(GER-2)
STB
Eclairagede50 WATT-Garantircomponantexactparsyst_me.
Emergency Release Kit - Provides access to garage from outside in the event of an electrical power failure.
N6cessaires de D4clenchement de secours - Len_cessaire de d_clenchement de secours est con_upour vous permettre d'acc4der & votre garage depuis
I'ext_rieur en cas de panne de courant et Iorsqu'il.
Adapter Brackets (2) - Used in conjunction with standard STBBrackets. They provide additional clearance and mounting options.
Crochets d'adaptateur (2) - Utilis_ conjointement avec STBstandard reenter les crochets, ils fournissent le d_gagement suppl_mentaire avec monter d'options.
P/N 26210A.S
P/N 35675R
P/N 34439R.S 54.37
520.00
55.00
52.73
Ordering Instructions
No C.O.D.shipments. Please include check or money order, made payable to The Genie Company. Do not send cash.
Allow 3-4 weeks for delivery. 1-800-354-3643. Please have part number and credit
card ready. Mail Order Form to: Genie Company, 22790 Lake Park Blvd, Alliance, Ohio 44601. We accept Visa or
Mastercard on phone orders only.
Please add local sales tax if you reside in one of the states listed.
Californla, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, Virginia, Wisconsin
TOTAL ORDER $
SHIPPING & HANDLING $ 6.00
STATE SALESTAX $
GRAND TOTAL $
Instructions Commandant
Pasd'exp_ditioncentre remboursement.Veuillezinclure un cheque ou un mandat bancaire,le payablefaitaThe Genie Company.
N'envoyez pasd'argent comptant. Accordezde 3 _4 semaines pourla livraison.1-800-354-3643.Ayezsousla mainle num6rode la
pieceet celui de lacartede credit.Mettre _la paste learrngement _:GenieCompany,22790 LakePark Bivd, Alliance,Ohio 44601.
Nousacceptonslescommandespar t_l@hone avec paiementpar cartede creditVisaou Mastercard.
Veuillez indiquer les taxes de vente locales si vous r4sidez dans I'un des
_tats r4pertori4s ¢i-dessous.
California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, Massachusetts, Michigan, New Jersey, New York,
Ohio, Tennessee, Virginia, Wisconsin
COMMANDETOTALE $
MANUTENTIONETEXPEDITION $ 6.00
TAXEDEVENTE $ TOTALGLOBAL $
SHIP ORDER TO: EXPEDIER MARCHANDISE POUR:
NAME / NOV
ADDRESS / ADRESSE
CITY / VILLE
STATE / ETAT
ZIP / CODE POSTAL
(Pricessubject to change without notice) (Lesprix assujettissentpourchanger sansla notification)
14 For Help, call 1=800=35=GENIEorvisit www.geniecompany.com
Loading...