ASSEMBLY AND
DC
INSTALLATION
POSTER
LIMITSWITCHES
READ OWNER'S MANUAL COMPLETELY PRIOR TO INSTALLATION
RAIL STRAP/RAIL HEADER
£
TO WALL
PE
(yellow shoulder boJts)
WIRE CLIPS
BASED ON THE HEIGHT
OF YOUR READER_ A MOUNTING BOARD
MAY BE REQWRED FOR _TACH_NG
HEADER BRACKET
DOOR BRACKET
TO DOOR ARMS
TO CE[UNG
RAIL SECTION
CONNECTION
DOOR ARMS
DOORS _ADE OF MASOMTE, LIGHTWEIGHT
WOOD, F_BERGLASS, AND
METAL MUST BE PROPERLY BRACED
BEFORE MOUNTING
3OR OPENER
DOOR MANUFACTURER
OR DISTRIBUTOR FOR
BRACING iNSTRUCTiONS°
NOT INCLUDED
1/4" x 1ol/4" Lag BoB
Recommended for doors too thin for 2" Lag Bolts
or
1/4"o20 x 2" Carriage Bolt//1/4"o20 Hex Range Nut
WOODEN DOORS
SHde Collar over _ong Hook
Mate Hooks
Slide Collar over Joint
Snap C_Jpbehind Collar
TO
(SHORT AS POSSBL8)
(LONG AS
O 2007 GM_ Holdings, Inc., DBA The Genie Company
Hold Power Head so that end of shaft and rail attachment flange is
facing up.
B
hstaH Coupler on Motor Shaft (Figure 1).
Place Coupler over end of shafLTurn it until it drops down over
Lay Power Head on its top.
The Ddve Screw Canslide out of RailSections. Keep Rail Sections level
C
Connect first Rail Section [with bearing (Figure 1)] to Opener Power Head.
Slide Drive Screw so that bearing end extends several inches
out of ra&
Insert bearing end of Screw into Coup[er.
Slide Rail into attachment flange and align hobs° Connect with 2 (yellow anodized) 1/4"o20 Hex Head Shoulder Bolts and 2 (1/4"-20) Hex Serrated Flange Nuts (Figure 2)_ Fingerotighten until later.
INSTALL REf4A_N_NGBAK S£CT[IONS
A Arrange stamped arrows on Rail Sections to point in same direction
and away from Power Head, (Middle rail section has same hole patern on both ends, be sure and douMe check the arrows.)
Connect Screw Sections:
- Push Middle Drive Screw out about 2" toward Power Head.
- S_ideCollar over Middle Drive Screw Hook (Figure 3A).
- Turn Middle Screw by hand to align Drive Screw Hooks
between First and Middle RaNSections.
- Latch two Hooks together and slide Collar over them
(Figure 3B) and (Figure 3C).
- Snap C_ip on Drive Screw next to Collar (FigureSD).
B Attach Middle Rail Section to First Rail Section, using 2 Rail C_amps,4
(5/16"ol 8) Hex Head Shoulder Bolts, and 4 (5/16"-18) Hex Serrated
Flange Nuts (Figure 3)° Finger tighte_ u_tH _ater. (Curved edge of
rail clamps should face downward,)
If a Rail Extension is needed, attach it now per the instructions included with the Kit,
Attach End Rail Section to Middle Rail Section following procedures
in Step A & B.
INSTALL CARR_AG£ STOP AND CARRIAGE
A Place Carriage Assembly Lever in Disengaged position. (Figure 4),
Slide Carriage Assembly into sbt on End RaN Section with arrow pointing away from the Power Head.
Power Head Asser_b_[y
Ace one de cabeza
F_rstRai[ 5ed_ie_ Zo_£[er
Primero secci6n Elacoplador de baranda
ATTACH RAiL STRAP TO _ND RAiL S_CT_ON
A Attach Rail Strap to End Rail Section,
Threaded stud of Rail strap should pass in front of end of Rail,
Use 2 (1/4%2@ Hex Head Bolts and 2 (!/4"o20) Serrated Flange Hex Nuts (Figmre 5)°
Tighten securely but Do Not overotighten°
AL_N RAK S£CT_ONSAND T_GHTEN ALL BOLTS
Align all Rail Sections so Carriage Assembly can slide freely along
length of Rail,
B
Securely tighte_ aH fasteners _owo Do Not over-tighten.
INSTALL AND CONNECT bM_T SW_TCHSS
A
Turn Opener right side up, Support Power Head on soft material
(cardboard, rag, etc.) to protect against damaging the light sockets,
B
Place Switches on Rail (_ig_re 6).
Place CLOS£ switch (brown wire) about 15" from Rai_Strap end of Rai_(Standing at Rail Strap boking toward Power Head, Switch wiII be on right side of Rail),
o Insert (#8_32 x 1") hex head set screw into Switch and ringer
tighten only to temporarily hold Switch in place,
- Leaving a litde slack in the Wire, run it down the groove in
top of Rail toward Power Head.
- Hold in place withWire Clips.
- Attach to Power Head terminals 5 & 6.
o Place OPEN Switch (white wire) about 15"from Power Head so
that it hangs on same side of Rail as the CLOSE switch.
Insert (#8_32 x 1") hex head set screw into Switch and finger tighten only to temporarily hold Switch in place.
- Leaving a little slack in the Wire, run it down the groove in
top of Rail toward Power Head.
- Hold in place with Wire Clips.
- Attach to Power Head terminaB 4 & 5
Coil remaining Wire on top of Power Head° Hold with twist ties or tape.
Attach Emergency Release Cord '_
A
Tie overhand knot at one end of emergency release cord and
pun cord through the hole in the release [ever up to the knot.
Thread opposite end of cord through knob and tie a knot in this end also,
Following installation of your garage door opener, adjust the height of the knob to no less than 6 feet above the floor°
The Emergency Release Cord is threaded through the Carriage
rdease [ever at the factory
Rai_Strap L£_correa de[a baranda
Carriage 5to_ Paradade cod/e
5116"-18 eex Head Sho_der _[_ 1/4"-20 Hex 1t4'-20 Hex Head 1/4"=20 Hex
Iuerca de reborde _ dentada hexagonal
de 5/16"-18 ]uerca de reborde Tuerca de reborde 1/4"--20 [uerca
5JI_"-18 He× _er_ted Fla#geNuts
®@®@
[uerca de reborde
dentada hexagonal de 5/16'--18
Set.ted _qa_ge N_ts Sho_der _[ts (yem_w) Head Be_ts
dentada hexago_lal dentada hexagonal hexagor_al de la de1/4"eo deW4"-20 cabeza
Coupler ¢o[[_rs +sD_re Retai_i_g Clips +s_a_ Acopbdor cue[los y reserva dipes que ret enen y _eserva
CONECTAREL R_ELALA _AJA DE_ONTROL
Grar la caja de control de mode que el panel frontal (con el extreme de la flecha y B brida de acomp[aniento del rid) est# mirando hacia arriba.
B
Instabr el acompIador en b flecha del motor (Figura 1).
Poner el acompBdor encima de[ extreme de [aflecha. Girarb hasta que
caiga hacia abajo encima de la flecha.
o Colocar la caja de control sobre el rondo de la misma.
¢
Connectar [aprimera secd6n de[ rid [con chumacera (Figura 1)] a [a caja de control de[ abridor.
Des[izer Jaflecha motriz de mode que el extreme de [a chumacera se
extienda vadas pulgadas fuera de[ rieL o Insertar el extreme de Jachumacera de [aflecha en el acompbdoro " Des[izer el rid en b brida de acompBmiento y aIinear los agujeros. o Conectar con 2 pernos de cabeza hexagonaJ de 1/4"-20 (amari[[os
anodizados) y 2 tuercas de reborde hexagonaJes (de 1/4"-20). (Figmra 2).
Apretar a mane: m_s ade_anteo se har_ el apriete final
D
Deslice b parada del coche en [a baranda y contra el poder diringe.
[NSTALAR LAS SECC_ONES_ESTANTES DE _EL
Odentar [asflechas estampadas en bs seecciones de rieJesde mode que apunten en B misma direcci6n aJejadasde [a ca}ade control, (EIrie[ deJmedic
es igua[ en ambos extremes.) o Conectar Bs secciones de flecha motrices:
- Empuiar B flecha motriz intermedia fuera unas 2"hacia Jacaja de control
- Resba[arel cdJar sobre elgancho de B flecha motriz intermedia (Figura 3A),
- Girar la flecha intermedia amane para aIinear Josganchos de ;aflecha
motdz entre Jasseeciones pdmera y b intermedia de[ rieL
- Enganchar dos ganchos juntos y resba[ar eJcollar sobre dies (Figura3B y 3Q.
- Co[ocar r@idemente el sujetador en [aflecha motrizjunto a[ collar
B
Acop[ar la secd6n intermedia de[ rid a la primera secci6n usando 2 abrazaderas de rid 4 pernos de tope hexagona[es (de 5/'16"---18)y 4 tuercas de reborde dentadas hexagonaIes (de 5/16L18) (Fig_ra 3).Apretar a marne; m_s ade_a_te se har_ e_apdete fi_aZ
Sise requiere el ensamb[e Extensi6n (GSXL8), instSMo siguiendo [as instrucciones proporcionadas en eJ paquete.
C Junte [asecd6n final de [a baranda con [asecci6n intermedia siguiendo los
procedimientos descritos en los pasos A y B.
Wire CJips grapas
_mergeacy Re_ea_e K#eb la perilla de la liberad6n de la emergencia
Carriage Stop Parada de[ corredizo
[NSTALAR LA PARADA DEL CORRED_ZOY EL_ORRED_ZO,
A Resba[ar [a parada de[ corredizo en [a secci6n extrema de[ rid (Figmra 4).
B Desliceelensamblede[corredizoen b ranuraen [asecd6nfinal de barandconla
puntade laflechadirigidaen direcci6n opuestaalacaiade[motor (Figura5).
SUJETELA _ANDA DE_ARANDAALLASECGONFINAL
A SujeteB bandade[rid a[aseca6nfinal de[rid usando2 per nos decabeza
hexagonalde (1/4"o20}y2tuercasdereborde hexagonal(1/4"-20) (Figmra_).
Aprietefirmemente cuidando no sobreapretarlos
AL]NE£LASSECC[ONESDELA_ARANDAYAPR[ETE
A A[ineetodas[assecdonesdd rid de maneraqueel ensamb[edd corredizo
magn#ticopuedades[izarse[ibrementea [olargode JaJongituddd rieL
B Apriete firmemente todos lospemoscuidando no sobreapretarlos,
_NSTALARY CONECTARLOS[NTERRUPTORESb_TADORES
A Girar el [ado derecho del abridor hacia arriba, y sostenga [a caia de[ motor de
manera de evitar el romper los portI_mparas,
B Poner los interruptores en el tie[ (Figura 6).
, Poner el interrupter de CERRAR(aBmbra marr6n) a unas 15"@1 extreme
de la correa de[ riel (Estando uno en la correa del rid y mirando hacia [a caja de control, el interrupter estarg al costado derecho de[ riel).
° Insertar el torniHo opresor en el interrupter y apretar a mane solamente,
para sostener temporalmente el interrupter en el [ugar.
Deiando aIgo sueIto el alambre, correr[o abajo en [a ranura en el tope
de[ rid hacia [acaja de control Sostener en el [ugar con los sujetadores para cables.
Acoplar a [acaja de centre[ los terminaIes 5 y 6.
o Poner el interrupter de ABR[R(alambra gris) a unas 15"de [a caia de centre[
de mode que cuelgue al mismo lade de[ rid que el interrupter de CERRAR,
Deiando also suelto e[ aIambre, correrIo abajo en [a ranura en el tope
de[ rid hacia [acaja de control. Sostener en e[ lugar con los sujetadores para cables.
Acoplar a [acaja de control los terminaIes 4y 5.
Enrollar el alambre restante en el tope de [acaia de control y envolver con cinta.
A Hagaun medic nude en un extremede la cuerdade[iberaci6ndeemergencia.
B Ensarte el extreme opuesto de [a cuerda a trav#s de [a manija y en el
agujero de [a paBnca de [iberaci6n de[ ensambJe deJcorredizo magn#tico
Haga un medic nude en 6ste extreme de la cuerda de liberaci6n de
_ La Cuerda de la LiberatiOn de la Emergencia se enhebra per la
palanca de la [iberaciOn de[ corredizo en la fSbrica,
Brown Wire
a[ambra marr6n
S-,z ss _ d, so _
0 _
Bearing Coiinete
Arrow
F[echa
Figure I Install Coupler and IstRail Section Fig_ra I Instale el acoplador y primero secci6n de baranda
Figure 2 Boff 1st Rail Section to Power Head Figara 2 Cierre pdmero secci6n de baranda a la cabeza del poder
Cellar
Middle Rail
Se_tioa
La secd6n mediana deJa baranda
Figure 3 Attach Middle Rail Section Fig_ra 3 Conecte la secci6n mediana de baranda
Elcudlo
3Ao Slipon collar
Deslicecudb en gancho largo
3Bo EngageHooks
Comprometa losganchos
3C° SlideCollaroverHooks
Deslice cudlo sobre ganchos
3Do SnaponRetainingClip
Encaje a pres[6n e[ cJip que retiene
End Rail Section
LaSecci6n Final de rid
Figure 4 Slide Carriage Stop and Carriage onto Rail Fig_ra 4 Deslice el Conjunto de corredizo y [a Asambiea de[ coche en Baranda
(AHgnment Nub) Protuberancia de aHneaci6n
£_d Rail Section
La Secci6n Final de rie[
Rail Strap Correa del del
Figore 5 Attach Rail Strap Fig_ra 5 Correa del riel
Figure 6 Install Limit Switches on Assembled Rail Figura 6 Insta[e los Interruptores de los Limites
Emergency Release Tag Leetiqueta de[a [iberaci6nde
de emergenc a
Figure 7Attach Emergency Release Cord/Knob and Tag F]g_ra 7 Conecte la Emergencia Cuerda de Liberaci6n y Etiqueta
La Pe ilia de la [ berac 6n
de [a emergencia
Release K#eb
NOTE
For lightweight garage doors, make sure you have installed the proper reinforcement (See Check Door Condition and Thickness on page 5 in manual),
TheHeaderBracketmustbefastenedtothe
mounting platefor the Header Bracket,The Bracketcanthen be mounted at the propel
location and have sufficient Support.
If adoor spring is in the way place the Header
Bracketabove the spring, Do Not move the door spdngi
A Before mounting the header bracket, see CHECK
STEP4, in Operation & Maintenance Manual for mounting instructions, ff needed, attach a 2"x 6"
board across wall studs where you made your Header Bracket mounting point mark (Figure 8).
Transfer your mark from wall to board.
B Attach Header Bracket to header at your mark
above garage door.
NOTE
R is critical that point where Rail attaches to Bracket be on centedine of Door.
Mark two Bracket hole mocations.
Drill 2 (5/32") pibt homes.
Attach Header Bracket using 2 (1/4"x 2") Lag
Screws.
DOoisrnadeofmas0nite:lightweightWOod, I
fiberglass,metN,orotherlightweightmaterialsmust
be proper y braced before mount ng door Opener. J
For sectional doors:
A Place Door Bracket on door center line, no lower
than top roller, and mark holes (Figure gh
[3 Attach Door Bracket:
For metal doors, use 3 (1/4" =20 x 3/4") Self_ Dri[ming Screws (provided). For wooden doors, use 3 (1/4" x 2") Lag Screws or
_ (1/4" x 1=!/4") Lag Screws or 3 (1/4" x 2=1/2")
arriage boks (not provided).j
Beforeinstalling, check length of the induded Lag Screwsvs.the thickness ofyour garage door. For doors thinner than 2", use1ol/4" Lag Screws.Checkdoor
condition and thickness.Seepage3 in Operation & Maintenance Manual
For one-piece doors:
A Position Door Bracket on door's center line, as high
as possible or on top of door.
B Attach Door Bracket:
For metal doors, use 3 (1/4" =20 x 3/4'*) Serf= DNlling Screws.
For wooden doors, use 3 (1/4" x 2") Lag Screws or 3 (1/4" x 2")Carriage hefts (not provided).
ATTACH RA|L TO HEADER [}RACKET
A While supporting the Power Head, place threaded
end of Rail Strap Bolt through Header Bracket hole (Figure lg).
B Attach (S/16"=18) FDnge Nut to Rail Strap Bolt.
Finger=tighten unti| |ater.
MOUNT'NOPowERHEA
Z UTnO
ounting Bracketsmust befastenedto garaqefram!ng,De Ngt 1
fastento drywall,particleboard,plaster,ororbet suct_rhateriak
. MakesuretherailofyoursupportedPowerHeadisslightlyhigherthan
thehighestpointof doortravelbyraisingthedoortocheck.Adjustas needed,
, MaterialsneededformountingOpenerPowerHeadtogaragemay
vary.Readallinstructionscompletely.
. Garageconstructionsdiffer.Extramaterialmaybeneeded,SeeCheck
PowerHeadMountingAreaonpage7inmanual
A RaisePowerHeadandsupport it high enough that you can
manuallyraisethegaragedoor fulmyopen, B Lineup PowerHeadand Railwith center ofgaragedoor. C KeepingPowerHeadcentered,mountto ceiming:
Atproper height; a. Forsectieea[ deers, mount power headata height
whererailislevelwith fleer orslightlybwer.
- CheckforclearancebetweenRailanddoorasit opens(Figure11).
b, Foror.e-piecedeers,mount powerheadsothat
there isaminimumdearanceof 2"between railand
doorasit opens(Figure11).
D Using one of the preferredmethodsshown (Figure12},mount
PowerHead(Use5/1B'-18x3/4 hexheadBoltsandS/16'q8 FlangeNuts).(Itispossibb to useothermounting methods,The
criticalpoint to remember isthatthe mountingassemblymust besolidlyattachedand ableto support theweight of thePower Head.)DONOTATTACHTODRYWALLORSUSPENDEDCEILING.It
must be anchoredto the garageframework,
ASSEMBLEAND CONNECT
DOOR ARMS
For sectional doors:
A Attach short side of Curved Door Arm to Door
Bracket with Clevis Pin and Cotter Pin (Figure 13).
[3 Attach Straight Door Arm to Carriage with Clevis
Pin and Cotter Pin.
C Attach both Arms together with 2 (3/'8" x 7/8") Hex
Head Bolts and 2 (3/8") Serrated Flange Hex Nuts so overal[ [ength is as short as possible. Securely
tighten fasteners.
D Adjust height of Emergency Release Cord Knob to
6' above floor:
Pull Cord through Carriage Release Lever until Knob is 6' from floor.
Tie a new overhand knot in Cord at Carriage
Release Lever.
For one-piece doors:
A Attach Straight Arm to Door Bracket with CmevisPin
and Cotter Pin (Figure 14).
B Attach short side of Curved Arm to Carriage with
Clevis Pin and Cotter Pin.
C Attach both Arms together with 2 (3/8'* x 7/8") Hex
Head goffs and 2 (3/8") Serrated Fbnge Hex Nuts so overall length is as |ong as possible_ Securemy tighten fasteners.
D Adjust height of Emergency Release Cord Knob to
6' above floor:
Pull Cord through Carriage Release Lever until Knob is 6' from floor.
Tie a new overhand knot in Cord at Carriage Release Lever.
Do Not skip Step D above[ Failureto comply may leave Emergency
ReleaseKnob within reach of Children: ff the Knob ispulled with ga[age door fully or
partially open, garage door may dose RAPDLY
without wamiDg!
SYSTEM
ELECTRICAL WARNING-
Ensure there is NO power to the Opener before installing Safe-T-Beam® System wires.!fOpener !s
plugged into outlet, Unplug it Now,
NOTE
The Opener will not dose the door automatically unless the Safe-T-Beam ® System is installed.
A [nsta[I Safe=T=Beam ® Source and Sensor
(Figure1S):
Mark both sides of garage door frame or waHH
6" above floor.
Hold Bracket against door frame or wall Check
if Bracket extends out from wall far enough so tongue of Bracket is beyond door, tracks, or any door hardware. Hfnot, Safe=T=Beam®
Mounting Bracket Extensions are avaimabme from a Genie Factory Authorized Dealer or through the Accessories Order Form_
- Bmocksof wood, etc. may be substituted for
extensions.
Position top of Mounting Bracket at 6" mark and fasten with 2 (#10=! 6 x 1=1/4") Phillips Hex
Head Screws per Bracket.
NOTE
Mounting Brackets can be attached to brick walls or concrete floor using masonry anchors (not included).
B Attach Safe=T-Beam ® Source (Red LED) and Sensor
(Green LED) to Brackets (Figure 1S):
For s[ngle-door garages_
- Determine which side of garage receives the most direct sunlight, and place Source (Red LED) on this side whenever possible.
For multipb-door garages see (Figure 16).
Preventing crossed signals is critical Place Source and Sensor modules on
adjacent doors facing in opposite directions.
[ NOTE
To help prevent interference from the sun, the Safe-T-
Beam ®Sensor (Green LED) may be placed further away
Ifromthe door opening,where it will spendmore time
in the shadows.
Slide the Safe-T-Beam ®Source and Sensor onto the tongues of the Brackets until they
click into pbce, Check final height of Lens (Figure 17).
CAUTmON
StapleswhicharetOOtight mayCutorpinchWires.CUt or pinchedWirescancausetheSafe-T-Beam®System
tostopworking,Wheninsta!lingtheBulated Staples, makesureyoufastenthemOn!yastightlyasneeded to holdthe Wiresecurely.
C Install Safe-T-Beam ®Wiring: (Figure 18)
Route Wire and hsu[ated Stapmes (F_gure lg, and 20).
- Securemyfasten Wires with hsuhted Stapbs as you go. Stapbs should be snug only.
- Wires between garage wall and Power Head should be run on top of Rail and underneath Wire Cmips.
Attach Wires to Safe=ToBeam ®Sensors.
- Spmitand strip Wire ends to be connected as shown.
- Loosen Terminal Screws.
- insert each Wire under flat plate and tighten Screw. It does not matter which Wire, white or striped, goes on which
Terminal,
Attach Wires at Power Head.
- Wires are connected to Terminals #3 and #4 on Power Head Terminal Block. ff does
not matter which WR'e, white or"striped, goes on which Terminal
Check the following.
- Ensure that no part of door or its hardware is in path between Source or Sensor
Lenses.
Ensure that tops of Lenses are between 5"
- 6" above floor. Brackets are flexibme and can
be adjusted sIightmy if needed.
NOTE
The Safe-T=Beam alignment check will be performed following connection to eieEtriEal power. Do Not plug
in yet[
®
WALL CONTROL[NSTALLA_ON
[_ wAR.m.G
More than one lighted Wall Central per Opener will causea maffunEtion.
WALL CONTROL (Figure 21 & 22)
A Finding the mounting location(Figure 22).
Pick a convenient location for mounting wail
control
- Location you choose should be in direct sight of door.
- h should be at least S'above floor to prevent small children from operating
door.
- It must be away from any moving parts. (You should not be able to reach the garage
[} Wiring (Figure 22):
C Mounting:
door while standing at Wall ControL)
Run wire from Power Head to Wall Control.
Securemy fasten to ceiling and wall using insulated staples provided. SpHit and strip ends of wire.
On Power Head:
- Attach the striped wire to Terminal #1 and white wire to Terminal #2.
On back of Wa[I Control:
- Attach striped wire to Termlna|"B'[and
white wire to Term[naJ "W':
Fasten wail control to wail with 2 screws.
_ _ #6 x 1=1/4"
Remove protective backing from Entrapment
Warning Label
- Stick bbem on wall near Wall Control
CAUT[O
' Use of any wall Consoles other than the type
Jndudedwillpreventthe lightfromworking
hold the Wire snugly.
] A WA RNmN
To reduce the risk Of e[eEtrical Shock, this equipment
hasagroundedtypeplugthat includesathird (grounding)pin.Thisplugwi[[onlyfit a groundedtype
outlet, if you do not have a grounded outlet, contact a qualified electrician to instal[ one. DO NOT aJter the
plug in any way. The door opener must be proper[y
groundedin order to preventpersonalinjuryand
damage to the components.
Connection with grounded plug: A Checklocal building codes:
Does buimding code require permanent wiring?
ff yes, have an electrician perform
"Connection with permanent wiring" below.
ff no, pmugdoor opener into grounded outlet.
. Perform Safe=T-Beam ® alignment check below.
Connection with permanent wiri#g
(Instructions for [kensed e_ectrician): A Remove powerfrom circuit.
B Remove Motor Cover.
Remove 4 screws from Cover and slide down off of Power Head (Figure 23).
Remove and discard power cord.
Cut power cord inside Power Head. Remove and throw away power cord, strain
relief and knock uut.
D install suitable entrance bushing and power supply
wire.
Connect permanent wiring to Power Head.
NOTE
There must be at |east 5 inches of black and white wire inside of Power Head
(between splice and entrance bushing).
- Connect white supply line to white wire.
- Connect black supply line to black wire.
- Connect ground to green wire (ground).
NOTE
Use only ULrecognized wire nuts.
Replace Motor Cover.
Slide Cover into place. Replace and tighten 4 screws.
F Reconnect power to circuit. Safe-T-Beam e Alignment Check:
After turning electrical power on, if STBsare not properly aligned, red LED (source) will b_ink continuously.
B To correct problem--STB mounting brackets are
flexible and may be adjusted slightly to bring the system into alignment.
When STBs are brought into alignment--red LED will stop b_inking and stay _it.
FORCE CONTROLS
Rough Setting of Limit Switches
A Setting Close Limit Switch (Pigure 24):
Check that Carriage Assembly is disengaged. With garage door fully closed, slide Close Limit Switch toward Carriage ueq it is aligned with Carriage magnet. Tighten Set Screw. Do Not over=tighten.
Setting Open Limit Switch:
Manually open garage door to full open position. Slide Open Limit Switch toward Carriage unti_
it is aligned with Carriage magnet.
Tighten Set Screw. Do not over=tighten.
Re=engage Carriage Assembly.
Setting Force Controls e_d Final Adjustment of Limit Switches
m
Thegarage dooropens rapidly, and Can pause sedous injury or death.
, Keep the path dear. . Position the ladder to the side of the Power
Head so it is clear of all moving parts of the
Opener and the door.
- Set the door Opener to use the m!n!mum force
needed to open the door.
Little effort is required to turn the Force
Adjusting Knobs.
ffthe door stops moving while opening or
dosing, adjust the Open Force or Close Force
Controls slightly clockwise (to slightly
increase the force) and retry the step.
The Open Force and Close Force Controls are tobe set to the mimimum force
necessary to ensure the door smoothly opens and closes completely. The garage door wi[[ move slowly the first time it runs, until the Opener "learns" the type of door.
Ensure the Carriage Assembly is engaged and is between the two Limit Switches
before operating the Opener.
A
Pre=set Force Controls to midpoint between
LO and H[ (Figure 25).
B
Adjust the CHose Limit Switch:
Press Wall Console to close garage door.
- If door does not dose completely, measure distance from bottom of door to floor. Move
Limit Switch same amount toward door.
- If door reverses after contacting floor,
move Limit Switch toward Power Head.
- If door reverses before contacting floor,
increase Close force.
Tighten Limit Switch Set Screw. Do not over= tighten (strip) Limit Switch Set Screw.
C
Adjust Open Limit Switch:
Press Wall Console to open garage door.
- ffdoor does not open completely, move
Limit Switch toward Power Head.
- ffcarriage is crashing into power head,
move Limit Switch toward door.
Tighten Limit Switch Set Screw. Do not over- tighten (strip} Limit Switch Set Screw.
D
Test Door Opener:
Run door up and down a few times using the
Wall Console and observe door travel
Repeat steps above as needed to set Limit Switch positions.
Adjust Open Force to minimum needed (Figure 2S):
Place door in dosed position using Wail
Console. Gently adjust Open Force fully
counterc[ockwBe (minimum force).
Run Opener using VVaHConsole_
Observe that door runs to Open Limit Switch.
- ifnot,adjust Open Force Control slightly clockwise, dose garage door, and open it again.
Repeat steps above until garage door runs
smoothHy from Close Limit Switch to Open
Limit Switch.
Adjust C|ose Force to minimum needed (Figure 2S):
Place door in open position using Wall
Console. Gently adjust Close Force fully
counterclockwise (minimum force).
Run Opener using Wall Console.
Observe that door runs to Cbse Limit Switch.
- Ifnot,a_ust CloseForceControl slightly clockwise, open garage door,and close it again.
Repeat steps above until garage door runs
smoothly from Open Limit Switch to Close
Limit Switch,
SAFE-T-BEA_ ® FUNCTmON
[
Limit Switch and Force Adjustments must be completed
|before checking the contact reverse function F sure 25).
A Open garage door using Wall Console.
Lay a 2" x 4" board flat in center of doorway (Figure 26).
C CHosedoor using Wa[_Console. D Check that door stops and reverses within 2 seconds
after it contacts board: o If door does not reverse, decrease Close Force
untiH door reverses.
, ff door still does not reverse, move Limit
Switch toward door.
E Check Safe=ToBeam® System (STB) operation:
ff beam is blocked, door will not dose (Figure 27).
NOTE
Thedoormustcontact the 2"x4"boardbeforetheCarriageacti- vatesthe CloseLimit Switch.Ifnot,readjustthe dose Limit Switch.
Program Transmitter, install Light and Lens A See Operation & Maintenance Manual.
[Parepuertasde sara e de peso[igeras,asegOresedequeha
I NOTA 1
|instahdo losrefuerzosadecuados(Veala secciBnsobre [verificaciBnde lacondiciBny espesorde la puerta enla paginaS)_
_ONTAR EL SOPORTE DE
TRAVESA£O
PRECAUTION
' E[ soportede[travesahodebeasegurarseaB estructurade[garaje.
NoIoasegureaparedesagdetadas,detablesdeaglomerado,yeso,u
otros materMessimilares.
o Puede sernecesadoer.samNarunatabB de2'x6"a b largodela
estructurameteilicadela paredbcalizadaperendmadd travesaho dela puertaparaquesirvacomeplatademontajedelsoportedel
travesa_o.E[soportepuedeer.toncesmoetarseene[Dgar
adecuadoy tenetrefuerzosuficiente.
Siur.rosettedela puertainteffiere,coloqueeBoporte de[
travesa_operencimadelresorte.Nomuevaelresortede[apuert&
Siserequiere,ensambleunatabh de2"x 6"(Figure8)cona[menos dos(cuatroesrecomendaNe)tornillosparamaderay rondanas
planas(noinduidasconelpaquete).
B Ponga el lade derecho de[ abrepuertas hacia arriba, y
sostenga [acaja del motor de manera de evitar el romper los portal_mparas.
Lasvariaciones de montaje se muestran en iaFigure 8. Cuaiquiera de esaspuede usarse dependiendo dei espacio. Sin embargo, es criticoque ei punto donde se ensambia ei
rid a_soporte del travesafro est_ en _aiinea de centre de _a puerta.
Marque Insposiciones de los 3 agujeros.
Barrene 3 agujeros pibto de 5/32':
Ensamble el soporte del travesaho usando 3 torni[Ios para
madera de t/4"x 2'.'
_ONTAR EL SOPORTE DE LA PUERTA
PRECAUT[O
as puertas hechas de masonita, madera ligera, fibra de |
vidno, metal, u otros materia[es ligeros ddSen asegurarse adecuadamente antes de insta[ar e[ abrepuertas. J
En el Case de Puertas Secci6nadas:
A Co[oquee[soportede[apuertaen[alineacentral de[apuerta,
procurando que noquede masabajode[ rodi[[osuperior,y bs agujerosguia hechos(Rgwa 9).
[} Acopbr el soporte de Hapuerta:
Para puertas met_[icas, user3 torni[[os autorroscantes (de 1/4"=20x 3/4") (que se proveen).
Para puertas de madera, usar 3 pijas (de 1/4"x 2"6 3 pijas (de 1/4"x 1=1/4")(no se proveen).
[
induidos en el paquete contrad espesor de la puerta de su garaie, Para puertasm_s ddgadas a 2'; use tornillos para madera de -1/4'.
VerifiqueHacondkidn y espesordela puerta.VeaHapggina3en El
Antes de instalar,verifique b Iongitud de bs tornillos para madera
ManualdeMantenimientoy Operaci6n.
Pare Puertas de ann sole plezas:
A Coloqueelsoporte deb puerta enla [ineacentral deBpuerta,
tanalto come seaposiNeo en sucaseenb partesuperiorde b puerta.
B EnsamNeelsoporte deb puerta:
Parepuertasdemetal use3torni[[osautoroscarttesde
(1/4"-20 x 3/4") (induidos enel paquete).
, Parapuertasdemadera,use3tornillosparamaderadel/4"x2't
SOPORTE DEL TRAVESANO
A EnsambHeeHextreme roscadodellpernodeHacintadd rid en eH
agujerode[ soporte de[ travesaflo(Figure 10).
Coloqueunatuercade reborde(5/16"-18)en el pernode la
cintadel rieLAprietemanualmente
ENSA_4BLELACAJA BEL MOTOR [)ELGARAJE
PRECAUTION ]
Lossoporte_demoRtajedeber,asegurarse_ laestructuradel
garaje,No losasegureaparedes,detaNas de aglomerado,yeso,u otros materiaesslmi ares J
insulated Staples
(approximately 30 parts)
Grapes aisbntes (Approx 30inidades)
Hardware(redbag)
#6=11/4"
Pan Head Screws
TorniI[os de cabeza
troncocBnica#6 = ] =1/4"
NOTA
. AsegOresedequeelridde[acaade[motorco[ocadaest_[igeramentem_s
altoquee[puntom_saltode[acarreram_ximadeviaede[apuerta, mediante[ae[evad6nde[apuertaparaverificado.Ajustecomeseanecesado. Losmaterialesparae[montajede[acajade[motorde[abrepuertaspueden
variar.Leatodaslasinstrucdonescomp[etamente.
, Lasconstrucdonesdelossaraesvarian.Sepuederequerkmaterialextra.Vea
[ap@ina7parevedficare[_reademontajede[acajade[motoc
A
Levante[acajadecontrol y sopBrtdasuficientementealto de maneraque pueda levantarmanualmente lapuerta delgaraje
abri_ndolatotalmente.
B
Alineela cajadecontrol y el rid con el centrede b puerta.
C
Manteniendo centradala cajade control,monte al cielo raso:
A laalturacotrecta:
a. En_aspuertasensecciones,e[rid debe estara
nivd con el pisooligeramentedebajo del nNeL (Figura 11).
b. En_aspuertasdeunasoHapieza,eHrid no debe
interferirper unas2pulgadas.(Figure11).
Usandounode losm_todospreferidosque semuestra, (Figure12),monteb cajadecontrol.(Esposibb usarotro re@odedemontaje.E[punto crfticoquerecordaresque el conjunto dd montaje debeestersBlidamenteacopBdo y ser capazde soportar e[pesode b cajade controL) NOACOPLEA
UNAPAREDDETABLAROCAOAUNCIELORASOSUSPENDDO. Debeestarandado alentramado deb estructuradelgaraje.
_ONTAR Y CONECTAR
LOS BRAZOE DE LA PUERTA
Pare puertas secdo_es
A AcopBr el lade torte dd braze curvado de D puerta a_
soporte de b puerta con el pasador de horquilb y b chaveta de dos pates (Figure 13).
[} Ensambbel brazerecto de_apuerta alensamNedd eorredizo
magn@ico.
C EnsamNeambosbrazesjuntos usando 2pernosdecabeza
hexagonal(3/8"x 7/8 ")y 2tuercasde rebordehexagonal(3/8'! demaneraque b Iongitud total quedetan corta comesea posible.Apriete todos lossujetadoresmanualmente_
D Ajuste HaaHturadeHamanijade HacuerdadeHiberaci6nde
emergenciaa6' sobreelnivd dd piso:
. Coloquelacuerdaa travSsdd ensambledd corredizo
magn@co hastequelamanijaquede a6 'dd piso.
. Hagaun nuevomedio nude en lacuerdaen lalevadel
ensambledd corredizomagn@co.
Pare p_ertasde ann solepieza:
A Ensembled brazerecto a[ soportede[apuertausando e[
pasadorde horquilb y ladavijaben@@(Figure14). Acop[ar el [ado corto del braze curvado de [a puerta al
corredizo con el pasador de horquiIB yla chaveta de dos pates.
C EnsamNeambosbrazesjuntos usando 2pernosdecabeza
hexagonal(3/8"x 7/8 ")y 2tuercasde rebordehexagonal(3/8 ") demaneraque la Iongitud total quedetan [argacome sea posible Apriete lossujetadoresmanualmente.
D Ajuste laalturadelamaniiade lacuerdadeliberaciBnde
emergenciaa6' sobreelniveldd piso:
" CoHoqueHacuerdaatra%sdd ensambHedd corredizo
magn@co hastaque[amanijaquede a6 'dd piso.
. Hagaun nuevomedio nude en lacuerdaen b levadd
ensamNedd corredizo mash@ice.
_ede @jar [
[_os.Si b [
INSTALEELSISTEMA SAFE-T-BEAM®
EHabrepuertas no cerrarg [apuerta autom_ticamente a menos que elsistema Safe=T=Beam®est_ instabdo.
InstaBd6nde B fuente y e[sensorde[Safe-T-Beam®(Figure 15):
Pongaunamarcaen ambos_adosdd marcodepuerta del garajeo en la pared a6"per encimadel piSOa
° Sostengael soportecontraelmarcode la puerta ola pared.
Verifiquesiel soportesobresalede la pared Iosuficiente come paraque la espigaseextiendahacia lapuerta,sus guiasde deslizamientoo algOnotro componente.
- Encasequeno,existendisponiblesextensionesde[
soportede montajedel Safe-T-Beam®conundistribuidor autorizadode f_bRcaGenieo atray,s dd formate de
pedido de accesoriOSa
- Losbbques de madera etc puedensersubstituidosper
extensiones.
o Co[oquela partesuperiordd soporte de montaieen B
marcahecha 6"y asegurecon 2 tornillos Phillipsdecruz
cabezahexagonalpersoportedd( #10-16x 1-I/4")
Lossoportes de montaje se pueden instabr en paredes de
ladrilb o de concrete usando andas para mamposteria (no
i NOTA ]
induidas en el paquete).
B EnsambHeb fuente (diode emisorrojo)ydd sensor(diode
emisorverde)del Safe-T-Beam®a lossoportes(Figura 15): o Paragarajesde unasob puerta:
- Determinequ_bdo dd garajerecibeb mayorcantidadde bz dd soldirecta,ycoloqueelfoco( diodeemisorrojo)de lacajadelmotoren_stdadosiempreque seaposiNe.
o Paregarajesde puertasmO[tip[esvea[a(F[gwa16):
- Elprevenirlassehalescruzadasescritico.
- Cdoque losmBdulosdeb fuente y d sensoren puertas anexasapuntandohaciadirecdones opuestasentresL
NOTA
Paraayudar a prevenir interferencia con el sol,el sensor dd Safe=T-Beam®(diode emisor verde) puede colocarse lejos del vane de la puerta, ee un Dgar ee donde est_ D mayor
parte dd tiempo a B sombre.
o Des[iceb fuertte del motor y d sensordd sistemaSafe-T-
Beam®en lasespigasdelossoporteshastaqueatorenensu [ugar.
o Verifiqueb alturafinal de bs bntes del sensor(Figure 17).
C InstalaciondeSafe-T-BeameWiring(Figure 1B):
. Enrutee[cablecon [asgrapasais[antes(Figwa 19 y Figure 20):
- Sujetede maneraseguraloscablescongrapesaisbntes conformelosvayaenrutando.Lasgrapasdebenabrazar
sdamente bs cables.
- Loscablesquevanentrela pareddd garajeyb cajadd motor deben guiarsesobre b parte superiordd rid y per
debajodelossujetadoresde loscables.
EnsamNeloscablesalossensoresdd Safe-T-Beam®
- Separey palebsextremesfinalesdeloscablesparaconectar
loscome semuestra.
- Afloje los tornillos delasterminJes.
- Insertecadacableperdebajode lapbca pinnay aprietee[
torni[Io.No importa cualcable,blancoo rayado,va encual terminal.
, EnsamNeloscanes a la cajadepotencia.
- Loscablesseconectan alas terminales#2y#3dd Noque determinales de lacajadd motor,Noimporta cualcable,bBnco o rayado,vaen cual terminal
, Verifique[osiguiente:
- Que ningunapartedeB puerta o suscomponentes interfiereentre lafuenteyDslentes dd sensor.
, Aseg@eseque B pare superiordeBslentes est_
entre5y6"perencimadd piso.Lossoportesson flexiNesypuedenajustarseligeramentesiesnecesano.
NO CONECTETODAVlA!
[NSTALAC_0NDELACONTROL DEPARE#
ZL ADVERTENC A
Verifiqueque no hayaenergiael@tricahaciaelabrepuertasantes deinsta[arloscanes de [aconsoledepared. J
NOTA
M_s de un control de pared iDminado per e_abre puertas
)rovocar5 un maffuncionamiento_
CONTROL DE PARED (Figura 21 y 22) A Encontrar el [ugar montaje (Figura 22):
C Montaje:
Escogerun Dgar conveniente parael montaje dd control depared.
Elbgarqueescojadebeestarenb linenvisualdeb puerta. DebeestarperIo menosa5 piesarribadelpisopara impedirquelosnihospequehoshaganfuncionar[apuerta. Debeestarabjadodelaspartesm6v@s(Usteddebeset
B Cab[eado (Figure22):
capazdeakanzarB puertaestandoen e[controldepared.)
Instabr el canede b cajade controlal controlde pared. Apretarde manera seguraaHcido raso usando Hasgrapes aisladasque seproveen. Partuypelar losextremesdel cable. Enla cajade control:
- Acoplar e[ cable pdado altermmal #I y e[cane blaneo al terminal #2
Atr_sdel control de pared:
- Acoplar e[ cable pdado alterm!nal '3",y e[cane blanco al terminal "W".
Sujetare[control de paredalaparedcon 2torni,,os _}_@ #6x1=1/4"
Quitar e[forro interne protector de[a etiqueta deadvertencia de "atrapamiento".(Figura 23).
- PegarB etiqueta en lapared,cercadd control depared
P AuTm.
*Elusode cua[quierconsolade pareddiferentea[tipo
ieduido en este paquete evitar_ que [a Dz trabaje adecuadamente y podr[a causar que la puerta Opere sin
que se haya accionado intencionalmente.
oLos cable en cordo u opnmidos pueden causar que [a
console de pared no fuhcione. Siempre que use grapes aisBntes asegOrese de co[ocadas tan distantes come se
requiera pare mantener os cab esjuntos,
_L
CONECTAR LA POTENCmA
C[A
, Conelfindereducirelriesgodechequeel_ctBco,ekeequipotiene
unenchufetipotierraquecuentaconunatercerterminal.Esta
conexiBnseadaptar_solamenteaunatomedecorrientequecuente
_tipodeer.tradaadiciona.Sie enchufer.oentraen atoma
contacteunelectricistacertificado ueleinstalela
siemprequesetrabajeconlasinstalacionesel@tr[caL
CONEXI&N CON _OLmOTAPON Co_ Enchufe Macho CuR Coeexi6_ A Tierrao
A
Enchufar e_operador de la puerta.
Vea Advertencia de arriba.
- Enchufar e_operador de la puerta en un tom acorriente con clavija a tierra.
Realice cheque de alineaci6n de STB.
CONEX[ON CON EL ALA_BRADO PER_ANENTE {|nstruc¢iones pare ememectridsta)
A Desconecte b a_imentad6n de[ drcuito deNvado. B Quitar B tapa del motor.
Quitar 4 tornilbs de b tapa y resbabr abajo fuera
de b caja de control (Figure 23).
C Quite y deseche el cord6n de alimentaci6n existente.
Corte cuerda de poder dentro de caja de control Quite y tire e_poder cuerda, e_alivio del esfuerzo y knockout.
NOTA
Elcableado permanente adentro de la caja de control debe 6" minimo.
InstaHeuna entradade manguito adecuada.
ConecteeHcabHeadopermanenteadentrodeHa cajadecontrol.
- Conectee[cable dealimentaciBnblanco al aBmbre blanco.
- Conecteelcable dealimentaciBnnegroal alambrenegro.
- Conectee[abmbre detierraalabmbre verde(TIERRA).
NOTA
Elcableado permanente adentro de la caja de CONtroldebe 6" minimo.
E Vudva a instaBr [atapa de [acajade contrd.
DesHice[atapa, recto. Apriete loscuatro (4)tomilbs.
F ReconectelaalimentaciBnel_ctricaalcircuito derivado. Verificar _aa[i_eadB_de[Safe-T-Beam®:
A Despu_sdeconectarHaa[imentaci6nd_ctrica, s[d
STBnoest_alineado correctamente,e[DIODO LUMNSCENTErojo (fuente)parpadear_continuamente.
B Paracorregire[proNema- bs cartdas sonf[exiNesyse
pueden ajustarligeramente paraponere[sistemaenalineaciBn. Cuandoe[ STBest_alineadoel DIODOLUMINBCENTE
rojodejar_de parpadeary permanecer_encendido.
m
FUAR LOS CONTROLE$ DE
LOS [NTERRUPTORES Y LA FUERZA PosmcmoN DE AJUSTE
APRO×m_AOO DE LOS _NTERRUPTORESLm_|TADORES.
Aj_steaproximadodelos intetrruptorsdem_mitBs
A PosiciBndeajusteaproximadode[interrupter[irrfitadordeCERRAR
(Figure24), ' Verificarqueconjuntodelcorredizoest_desenganchad.
Conlapuertade[garajetotalmentecerrada,resba[are[interrupter
[imitadordeCERRARhadae[corredizohastequee[mismoest_ a[ineadocone[magnetode[corredize
B Austede[interrupterdelimitepareapertura:
o Abraapuertade garajemanuamentehastaque egueaaposiciBn
comp[etamenteabierta.
, Deslizere[intrruptorlimitadorde ABR[Rhadae[corredizohasteque
e[mismoest_a[ineadoconelmagnetode[corrediz&
Aprieteeltorni[[odefi aciBnde[IfmiteNo[osobreapriete. Vue[vaa conectarloscontro[esdeajustedefuerzade[ensamb[ede[ corredizomagn@coylosinterruptoresdeajustedelos[{mites.
LosCoRtremesPo_ieRtesdemaFuerzay UmiteQ_eAjustan
m
ADVERTENC[A
o La puerta del garaje se abre r_pidamente, y puede . causar dahos severos o la muerte.
Despeje e[ _rea,
Co[oque la escalera aun costado de [a caja de[ motor" con e[ fin de alejarla de todas [as partes en
, movimiento delabrepuertas y de la puerta.
Ajuste al abrepuertas de rnanera que use e[ minirno de
fufuerza pare abdrla.
A Pre-fijarloscontro[esdefuerzaene[puntomedioentreBAJO(LO)y
ALTO(HI)(Figure25),
B Ajustede[interrupterde[[[mitede derre:
, Presioneb consdadeparedparecerrarhpuertadelsarae.
- Silapuertano derracompletamente,mida[adistanciadesdela parteinferiorde[apuertahastaelpBo.Muevae[interrupterde [Hmitelamismadistandahacialapuerta.
- Si[apuertaseregresadespu_sdeestab[ecercontactocone[piso, muevae[interrupterde[[mitehada[acajade[motet
- Si[apuertaseregresaantesdeestab[ecercontactocone[piso, klcremente[afuerzadecierre.
o Aprieteeltorni[10defijadBndelinterrupterde[[imiteNo[0sobreapriete
C Ajustedelinterrupterde/limitedeapertura:
o Presione[aconsoladeparedparaabrir[apuertade[garae
- 5i[apuertano seabrecomp[etamente,muevae[interrupterde [imitehacialacajadelmotor.
- Si[apuertaabrecomp[etamente,petee[motorcontinOa trabaando,muevae[interrupterde[imitehada[apuerta.
o Aprietee torni odefijaciBnde imite.Noosobreapdete.
Serequiempocoesfuerzoparegirar[asperi[lasdeajustedefuerza. Encasedeque[apuertasedejedemovermientrasest_abriendoe cerrando,auBeloscontro[esdefuerzadeaperturaofuerzadederre ligeramentegirandolaperi[[aene[sentidodelasmaned[[asdelrelo(para incrementar[igeramentelafuerza)yvue[vaaliniciode_stepunto.
Loscontro[esaefuerzadeapertureyfuerzadederre@benajustarsea[as necesidadesminimasdefuerzacone[findegarantizarque[apuertaabrey cierracomp[etaysuavemente
Lapuertade[garae semover_[entamente[aprimeravezque@ere,hasta quee[abrepuertas'programe"e[ripedepuertaqueest_acdonando. AsegOresequee[ensam_o[ede[corredizomagn@coest_enganchadoy se
encuentraenmediodelosdosinterruptores8e[[miteantes8eoperare[ abrepuertas
NOTA
Pareprotegersunueva inversion,suPOWERMAXest5equipado con un rolei detiempo y conun contadordecidos,[oscua[es trabajan untos paraprevenircuakNier daho generadoper
taler a loscircuitos el_ctricosdebido aun excesodecidos en
unperiodo detiempo muytorte. Sisuabrepuertas
repentinamentesedetienecomerespuestaa un comandodela consda de pared- NODESCONECTELAUN[DAD-
simplemerlteespere10minuteshastaquee_relo detiempo / contador de cidos reinicie nuevamente.
LadesconexiBnde _aunidadevita que el rebj detiempo / contador de cidos sevueha a programac
Pruebade[abrepuertas: . , ,
, Accione[apuertaparequeabrayderreunascuantasvecesusando[a
consolede paredyobservebcarrerade[apuerta.. ....
, _epltalospasosarnDamenclona_osseqOnserequleracone[rmoe
ajusta[[asposicionesdelinterrupterde][mite.
ustedelaruerzaaeaperturaalm[nimonecesario(Figura25}:
Co[oque[apuertaenposkbndecerradausande[aconso[adepaled. Suavementeajuste[afuerzadeaperturagirandocompletamen_e_a peril[aensentldocontrarioalasmanedl[asde[reloj fuerzaminima.
Accioneelab[epuertasusandolaconsoladepared. Observequelapuertaseaccionaoeacuerdoalospar_metros
estab[edoosparqe[interrupterde[[[mitedeapertura., ,,
- SinoajusteelcontroldefuerzadeaperturaqirandoRperil[a [geramenteene[sentdodelasmanec[[asde[re[oj,derre[a
R puertade[garaje,y_bra[anuevamente_ , ....
epdalospesosantenoresnastaquelapuertadegaraprunaone
suavementedes@e[ interruptoroe[[imitedecierrehastae[ interrupterde[[imitede aperture.
ustelatuerzadecJerreaimmJmonecesario.(Figura25):
Coloque[apuertaen[aposidBnabiertausan[Jolacons@depard, Suavemen!eajuste[afu?rzadecierregirandolaperi[[aene[sentido
contradooe[asmaneci,asuelreloj(fuerzaminima). Accionee[ab,repuertasusando[acons@d,epareu. ObservequeRpuertaseacdonadeacuerdoalospar_metros estab[eddosparae[interrupterde[[[mitedederre
- Sinoaustee[controldefuerzadecierregirando[aperi[[a geramenteene sentdode[asmaned[[asde[ e[oj,ce e apueta
nuevamente.
Repitalospesosantedoreshastaq.u.elapue[tadelgarajefuncigne suavementedes@e[interruptordellimitedeaperturahastael
interrupterde[I/mitedecierre.
VER_FmQUELAFUNOON DE
REVERSAPORCONTACT{:)
f
A
Abra[apuerta de[ garaje usando[aconso[ade pared.
B
C0[0queunatablade 2"x 4"pinnaenelcentrede[clarede [apuerta.
C
Cierre[apuerta usando[a consolede pared.
D
Verifiqueque [a puerta sedetieneyregresa2segundosdespu_s deque Nzo contacto con la tabla.
o Si[apuerta no regresa,disminuya[afuerzadecierre hasta
que[apuerta regrese
Siaunasi[apuerta no regresa,muevae[ interrupter de hmite hacia la puerta.
Vedfique[aoperadBn de[sistemaSafe-ToBeame : ° Sie[ hazde [uz est_b[oqueado,[apuerta no. (Figura 27),
NOTA
Lapuerta debe tocar Hatab[a de 2" x 4" antes que el corredizo active el interrupter de limite de derre. Si no, reajuste e[ interrupter de _imite de cierre.
ElPasoFinal
El tra_smisorde[ programa, i_sta[a [as [uzes y el lento.
Vea El Manual de Mantenimiento y Operaci6n.
CenterLineaf doer CenterLiceof door La[Rleacentrald epuerta Lalineacentrald epuerta
',
o0a0,dir.0tl;- __!
intoHeader
Monte
directamente.:S2 _ g:-:_ _,\>ZLe-:cJL enelPar_ntesis":-- --- "__' ._:::e:_. derBracket
depared _____ " .::_= oard
Figure 8 Attach Header Bracket Figure 8 Conecte e[ par_ntesis de pared
SECTmONAL DOORS ONE-PmECE DOORS LASPUERTASDE SECC[ONADAS LAS PUERTASDE UNO PEDAZO
CenterL_neaf doer
La[[neacentraldepuerta
Figure 9 Attach DoorBracket Figure 9 ConecteParBntesisde Puerta
Figure 10 AttachRailStrapto HeaderBracket Figure 10 Conectebarandacorreaa[par_ntesisde[encabezamiento
Ceeter L_neafdeor La[ineacentra[depuerta
Rei[ Strap
La correa de la baranda
Tableadicionaldeapoyo
Elpar6ntesis de
encabezamiente
SECTIONALDOOR/ Puerta Seccional
CHECKEORCLEARANCE/ VeBfiqueparae_espacio[ibre.
H SLIGHTLYBELOW
Figure 11 Adjust the power head height
Figura 11 Ajuste [a a[tura de cabeza de poder
UNFiNiSHED CEiLiNGS
Mounting Straps
Las xorreas que montan
F|N|SHED CE|L|NG$ Locateceiling joists
ortrusses using a stud finder or similar device.
Attach angle iron (net included) te
joists or trusses through finish material
using Lag Screws
supportbeardaddedformo.gerspa_s
Sostengalatabla agregadapare
ONE=PiECEDOOR/ Puerta de una p[eza
MNMU/I OF2"/E[ minimo de 2"
Perforated Aegme[ren/not in_muded)
espaciosrn_slargos
Elhierro perforado del angulo (no induy6)
LOS TECHOS TERM_NADOS
Locabceviguetasde techo o braguerosque utilizana un
descubridor de semenralo disposaivo semejante.
Acople un perEI de hierro _ngulo (no se incluye en
redes los mode[os)alas viguetas a trav#sdel mateRa[
acabado usando[aspijas(30).
Figure 12 Mounting methods for open beam and finished ceilings Figura 12 Los MBtodos que montan para el rayo abierto y terminaron techos
®???
5/!6=18 x 3/4"
Hex Head Bolts
Header 1/4"x 2" Door Bracket Bracket Lag Screws
E[parantesis de La demora encrosca E[par_ntesis de puerta
encapezamiento de 1/4"x 2"
As short as poaaibme
Tan brevemente come /*_,
sea )osibHe_m, qR3k-_)
Curved Door Arm ElbrazecurvodeHapuerta
La cabeza hexagonal
cierra de 5/16"=18 x 3/4"
It_1 /_ "'L _StraightDoorArm
,.-" _/' _'(g_h Elbrazo recto de (3_z ":_' lapuerta
Figure13 Assemble Arms (SECTIONAL) Figure13 Arme armamentos (local) de puerta
Safe-T-Beam Sensor
Green LED @
ElSensor (Verde LED)
Safe-T=Reem ®Sourceaf_'_
Red LED
La Fuente (Roio LED)
Figure 1S install Safe=T=Beams ® Figure 15 [nsta[e Safe-T-Beams ®
®
_ lide onto
5/16=18 x 3/4"
Hex Serrated FHangeNuts
5/16"=18 Las nueces serradas
hexagona_es de reborde
Aaioegaa poasibie Tanlargo como seaposible
Figure 14 Assemble Arms (ONE=P_ECE) Figure 14 Arme armamentos (uno pedazo) de puerta
Desliceen lengua
de par_ntesis hasta que haga dic en
el lugar __
tongue of Bracket until it dicks into
place
// / I":: [ B:racket 6" ' _ (47_ I floor
,_ _ ." _ La alma de
._ , H .'[' parBntesis-6" i_AI]l'i'-L enc,ma de piso
IIIlfi_!t#_ljI,LLL_
Self=Drilling Screws
Los torni[[os que auto
ta_a@ando de t/4"-20 x 3/4"
El braze curve de la puerta
\ 5@lraight Door Arm
El braze recto b puerta
.above
Topof
1/4"=20 x 3/4"
#10=16x 1V4"
Phillips Hex Head Screws
Safe-T-Beam ®
(STB) Brackets
Supportes de_ Safe-T_Seam
Garaje con u_a puerta Garaje con dos puerra
Gara N con tres puerta
Torni_[o Phillips de cabeza 3/8" Hex Serrated
hexagonal #10-16 x 1-1/4" Flange Nuts
@
Figurer5 Source!sensor Locations
Figure16 Locaci6n de Fuente/Sensor
5" = 6" above fbor
La cima de
Top edge of Lens
par_ntesis =5"-6"
endma de piso
Figure 17 Final Check Safe-T-Beams ® Figura 17 El cheque final de Safe=T=Beams ®
3/8" x 7/8" _. Cotter Pins
Hex Head Bobs _ ChavetadePernos de cabeza dos pates
Tuercas de reborde serradas
hexagona_es de 3/8"
hexagona_ de 3/8"x 7/8"
aHambra _-_
..... Aprox. [ H
"_ , i ,/J//Rrip
Wire /// approx.
@ j
Figure 18 Wire the Safe-T-Beam ®System Figure 18 A[ambre el Safe=T-Beam Sistema
!
Figure 19 Wiring Method A Figure lg E[ re@ado que a[ambre A
F
Clevis Pins
Pasadores de horqui[[a
A r x _< Peb_prox
1 2'"
®
Wire cmips/Ela[ambresujeta
mnsalatedStaples
Termieai attachments at Safe-T_Beam®
Lasfijacidnes terminales en SafeoT-Beame
TerminalAttachment at PowerHead LasRjaciBnesterminales en cabezadepoder
Mbw sDck/Permita r_ojo
White Wire to Termioam2
E"a[ambreb,anco l\\\/11
a,oterm,n. _2%
Etriped Wire %, Elalambre pdad t _
a[aterminal 1
Figure 22 Wail Control WMng Figure 22 A[ambrado de Control
Security Vacation Lock Switch
Figure21 ConsoB de Pared............... o............... Bot6n de pared.
Wire C[ipe Ela[ambre sujeta
Te_miea_attachments at PawerHead
Lasfijacidnes terminales en cabeza de poder
Figure 20 Wiring Method B Figure 20 E[m_tado que a[ambre B
toTermina[ 1 _'_j
@
Terminal attachments at SafeoT-Beame
Lasfijaddnestermina[es
en Safe-T-Beame
insulatedStaRlet/
Losgrapesaisladas
Aliewsleekfor
_djustmeRt
Rojopare
el ajuste
Termieal Attachmeetat Wall Control Lasfijaci6nes termina[es en [a Central de Pared
TERMINALS
Te_mina_"B"
Elal ambr e pelado
terminal "B"
Striped Wire t<_
Knockout pmug/Tap6nmaraviRoso el_ctrico
Figure 23
Remove screws
Figure 23 _ I Quita bs TorniHos _,
Open Limit Switch (deer felly open)
E[ Interrupter abierto dd I[mite
(puerta abre completament)
ClosedLimit Switch
(door fury dosed) _[_[ ....
EHInterruptor cerrar
de[ [[mite (puerta cerrd comp_etamente)
Figure24 Settin 9 Limit Switches Figura 24 El L{mite poniente cambia
White Wire to Terminei "W"
Elal ambre
blanco a [a terminal"W"
Cut w_res here.
Elcorte
alambra aqui.
Screw Tornillo
Elcoche (salt6)
Force
Contro[e
La Fuerza Contro[a
Figure 25 Making Force Adjustments F_gura 25 Los ajustes de _aFuerza
E_transmiser de[ programa,insta[a _as[oaesyel lento.
Veaa Du@o's/Manua[deConservaci6npagiea 11.
2" x 4" board [aid flat 2"x 4"table co[oc6 [a p[anicie
Figure 26 Checking Contact Reverse Figure 26 Verificar b Fuerza Inverse
Figure 27 Biock Safe=T=Beame Figure 27 BHoquee e[ Safe-T-Beam ®