GENFORCE GT6000 User Manual

Page 1
Petrol Powered Inverter Generator
User Manual
RETAIN THIS MANUAL FOR FUTURE REFERENCE
PLEASE READ THIS MANUAL CAREFULLY BEFORE USE
Page 2
Petrol Powered Inverter Generator
Table of Contents
Safety ......................................................................................................................................................................... 1
Parts Diagrams ......................................................................................................................................................... 2
Generator ...................................................................................................................................................... 2
Control Pa nel ................................................................................................................................................ 3
Set-Up .......................................................................................................................................................................... 3
Pre-Operation Checklist ................................................................................................................................ 3
Check the engine oil level ........................................................................................................................ 3
Check the Fuel Level ............................................................................................................................... 4
Check the Air Filter .................................................................................................................................. 5
Operation .................................................................................................................................................................... 6
Starting the Generator ................................................................................................................................... 6
Operating at High Altitudes ............................................................................................................................ 7
Using the Generator ...................................................................................................................................... 7
AC Power Applicatio ns ............................................................................................................................ 8
Output, Over load Indicator, Oil Warning Lig ht .......................................................................................... 8
Rated Output ......................................................................................................................................... 10
Current Use ........................................................................................................................................... 11
Oil Alert System .................................................................................................................................... 13
Switching Off the Generator ........................................................................................................................ 13
Normal Use ........................................................................................................................................... 13
Maintenance ............................................................................................................................................................ 14
Maintenance Schedule ................................................................................................................................ 14
Changi ng the Oil ......................................................................................................................................... 15
Air Filter Maintenance ................................................................................................................................. 16
Spark Plug M aintenance ............................................................................................................................. 16
Muffler Ma intena nce .................................................................................................................................... 17
Transport ation and Storage ......................................................................................................................... 18
Troubleshooting ..................................................................................................................................................... 20
Generator Is n’t Starting ............................................................................................................................... 20
Devices Connected t o the Generator Isn’t Starting ...................................................................................... 21
No Charge in DC Socket ............................................................................................................................. 21
Power Shortage .......................................................................................................................................... 22
Technical Specifications ...................................................................................................................................... 22
Page 3
Petrol Powered Inverter Generator

Safety

•
Before operat ing the generator, c arefully read and understand this manual, to greatly reduce the chances of personal injury or equipment damage.
•
Exhaust contains poisonous carbon monoxide. Do not operate the generator in poorly-ventil ated place. Ensure that the generator is located in a dry, airy, clean place.
•
When the generator r unning and the muffler is very hot, be careful not to t ouch it! Let the generator cool off first.
•
To prevent burns, please pay attention to the warning labels on the generator attached to the exhaust system.
•
Never connect to the power outlet in parallel wires or application-specific cable after running in parallel, as this may lead to electr ic shocks.
•
WARNING! Gasoline is highly flammable! Turn off the generator first befor e refuelling. Always ref uel in a
well-ventilated area. Do not smoke whe n refuelling.
•
If the unit is being used as a back-up power generator for buildings, it must be c onnected to the building’s power system only by a qualified electrician and must comply with relevant laws and electr ical codes. Otherwise, the power generator could short-circuit, and if people comes in contact with the power transmiss ion wire, the generator may explode, burn or cause fires to the building’s electrical equipment.
•
Before starting t he generator, always perform a pre-operation inspection first to avoid accidents and damages to the equipment.
•
The generator must have an allocated space of at least one meter away from objects and/or equipm ent.
•
The generator must remain horizontal during its operation. If the generator is incl ined in any way, it could result in fuel spillage.
•
Operators of t he generator should know how to quickly turn off the generator and to underst and the operation of all of its control components. Never allow untrained personnel to operate the generator.
•
Children and pets m ust stay away from the operating area of the generator.
•
W hen the generator is running, keep away from its rotating parts .
•
If improperly operated on, the generator can become potentially dangerous. Do not operate the generator with wet hands!
•
Store the generator in a dry location, away fr om rain and snow.
1
Page 4
Petrol Powered Inverter Generator

Parts Diagrams

Generator

2
Page 5
Petrol Powered Inverter Generator

Control Panel

Set-Up

Pre-Operation Checklist

IMPORTANT! Ensure that the ge nerator is placed horizontally and that it is turned off.

Check the engine oil level

IMPORTANT! Using 2-st roke engine oil could shorten the engine life. Use a high-quality 4-stroke engine oil, which must meet or exceed US automobile manufacturer 's requirements for the classificat ion of t he Am erican Petroleum Institute, SF level. Select the appropriate viscosity for the aver age temperature of the oil in your ar ea.
1. Loosen the screws of the side access panel to remov e the cover.
2. Remove the dipstic k with a clean rag to wipe the oil dipstick, without tighte ning the dipstick and insert it into the oil port to check the oil level.
3. If the oil level is belo w the bottom of the dipstick, add more of the recommended oil.
WARNING!
•
Insuffici ent engine oil could seriousl y dam age the engine.
•
The Oil Alert syst em will automatically shut down the engine before the oil level drops below the safety line. But in order to avoid inco nveniences caused by unexpected downtime, we recommend that you regularly check the oil level.
3
Page 6
Petrol Powered Inverter Generator

Check the Fuel Level

1. Use automotive gasoline (preferably unleaded or low-lead gas oline to reduce combustion and reduce environmental pollution).
2. When the oil level is t oo low, add fuel to a predetermined level.
3. Never use gasoline or a mixture of oil and gasoline.
4. Do not fill the fuel tank wit h water.
5. After refuelling, tighten the f uel cap.
4
Page 7
Petrol Powered Inverter Generator
WARNING!
•
Gasoline is explosive and flammable under cert ain condit ions.
•
When refuelling, turn off the generator and do it in a well-ventilated area. Do not store the generator near fir e or areas with strong sources of heat.
•
After refuelling, tighte n fuel tank cap.
•
Be careful not to spill any fuel when refuelling . Spilled fuel may cause fires or explosions. If there is any spilt fuel, ensure that the fuel has evaporated and t hat the area is completely dry first before starting the generator again.
•
Avoid prolonged, repeated exposure to gasoline or inhale its vapour. Keep the generator away from the reach of children.

Check the Air Filter

Check the air filter core, make sure it is clean and that it is operating normally.
1. Unscrew the access panel screws to open the access cover.
2. Remove the three screws on the air filter cartridge.
3. Follow the a rrow shown in the figure below to pull out the air filter dr awer.
4. Pull out the air filter drawer, check the air filter and, if necessary, clean or replace the filter.
5. Clean or replace the filter before rev ersing t he operation of installing air filtr ation devices.
WARNING! Do not run the generator when there is no air filter, otherwise it will cause rapid wear of the
generator’s parts through the carburettor into the generator. Due to the generator's breathing t ube leading to the air filter cartridge, the air filter sponge will have a small
amount of oil on it over time. If the generator is in continuous oper ation for a whi le now or wh en there is excess engine oil, the lower air filter c artridge will also have a small amount of oil on it, which is a normal pheno menon. Wipe the oil clean f rom them when the generat or is turned off and has sufficiently cooled down.
5
Page 8
Petrol Powered Inverter Generator

Operation

Starting the Generator

IMPORTANT! Before start ing t he engine, disconnect the load between the DC sockets first.
1. Turn on the Oil Switch
2. Set the generator’s engine switch to the "ON" position.
6
Page 9
Petrol Powered Inverter Generator
3. Pull the starter cord until you feel resistance, then following the direction of the arrow indicated in the figure below, quickly pull the handle to start the gen e rator.
CAUTION!
•
Do not let go of the starter cord after pulling it, but rather put it back slowly.
•
W hen pul ling the star ter cord, hold onto the generator tightly to prevent t ipping.
NOTE: If the engine c annot be s tarted, check oil level to the excl usion of other failures first.

Operating at High Altitudes

At high altitudes, the standard carburettor air-f uel mixture will be more concentrated, reducing the generator’s operating performance and fuel consumptio n increases. By placing the carburettor’s main jet unto a small point, while adjusting t he mixing ratio of the screw, you can change the engine performance in high-altitude areas. If you always use the generator at an altitude of 1,500 meters above sea level, contact an authorised service centre or the manufacturer to make changes to the carburettor.
The use of a suitable nozzle will decrease the engine horsepower by 3.5% and will incre ase it every 305 meters. If you do not do these adjustments, the impact of altitude on power will be greater.
NOTE: If the engine nozzle is des igned for high altitude operation, but will operate at lower altitudes, it may cause a lowering of output power, overheati ng and can even make the air-fuel mixture to o thin. These conditions can severely damage the generator.

Using the Generator

WARNING!
•
To prevent electr ic shocks, the generator should be grounded. A thick cable should be connected between the ground terminal and the external ground-source of the generator.
•
If the generator is being used as a power bac k-up for buildings, ensure that it is connected to the building’s power system by a qualified electrician and must comply with relevant laws and electrical codes. Otherwise, the power generator could short-circuit, and if people comes in contact with the power transmis sion wire, the generator may explode, burn or cause fires to the building’s elect rical equipment.
•
If the generator is conti nuously used, do not exceed the rated power given. In other cases, you should consider rated total power of the connected devic e.
•
Do not exceed the rated current of the electric al socket.
•
Do not connect the generator at home, as this may damage the generator or home appliances.
7
Page 10
Petrol Powered Inverter Generator
•
Do not use the generator for purposes other than what it were i ntended to do. Please ob serve the following additional requirements:
− Do not do a parallel connection with the generator.
− Do not lengthen the exhaust pipe.
− If you are going to use an extension cable, use a rubber sleeve flexible cable (the cable should meet the
requirements of local laws and regulations).
− Minimum length of ext ension cable: 1.5mm²; cable l eng th of 60m; 2.5 mm² cable length of 100 meters.
− Keep the generator awa y from other wires and cables, such as those for a distributio n network.
•
W hen using an AC power, DC power can also be used. If you want to use bot h AC a nd D C power supply, do not exceed the total power sum of both the AC and DC.
•
The motor equipment’s power should not be higher than the unit power calibratio n at the start.

AC Power Applications

1. Ensure that its output indicator (gr een) is lit.
2. Ensure that the required dev ice connected to t he switch is turned off, and then pl ug i n the device at the generator outlet.
WARNING!
•
If the overload indicator light (red) stays on, the generator will be damaged; and if the temporarily mild overload indicator light (red) is lit , it will shorten the life of the generator.
•
Before connecti ng a device to the generator, ensure that it is in good working condit ion first. If it appears abnormal, suddenly stops or slows down, immediately turn off the generator’s power switch, and then disconnect the device.

Output, Overload Indicator, Oil Warning Light

•
Under normal operat ing conditions, the output indicator light (green) will be lit.
•
If the generator is overloaded or there is an inter nal short-circuit in the connected device, the outp ut indicator (green) will be off and the overload indicator (red) will l ight up instead. If this happens, cut-off the current connection to the devic e.
•
If the red light is lit-up, turn off the generator and check the cause of the overload.
•
If the oil alert lamp is lit-up, the engine will automatically shut down. Check and see if o il needs to be added.
8
Page 11
Petrol Powered Inverter Generator
NOTE:
•
Before connecting a device to the generator, check whether the device is in good working condition. If the device’s r equired power exceeds that of the generator, connect the needed cable equipment, then star t the generator.
•
Ensure that the switch is connected to the device before it is put to use in the OFF position.
WARNING! After starting the engine, if the overload indicator light (red) is lit-up, check whether there is a load
connected to the AC outlet. If so, unplug the load cable, and then turn off the generator. In this case, the overload indicator light will flash for a few seconds until the overload indicator will st op flashing. Then, start the generator.
If after several consecutive starts the generator overload indicator lig ht is still on, and after checking the AC outlet and ensur ing that no load is connected, have the generator serviced by the manufacturer or an authorised service centre.
1. Connect the ground terminal
9
Page 12
Petrol Powered Inverter Generator
2. Requirements for starting the generator:
When the output indicator light (green) does not light-up, and the overload indicator (red) is lit -up instead, turn off the toggle switch of the engine, then wait after the overload indicator light goes out. After that, follow the Starting the Generator procedure to start the generator again.
3. Ensure that the connected device is turned off first, then plug it into t he generat or AC outl et.
CAUTION! If the connected device is turned on before connecti ng it to the generator, the device will
suddenly start, potentially caus ing injury.
4. When the output indicator (green) lights up, turn on the generator. NOTE: If there is fa ilure in the overload operation or in the internal equipment, the output indicator (green)
will go out and the overload indicator light (red) will then light-up. Also, there is no power output and the engine will not st op, so you must press the engine switch to the “OFF” posit ion to turn off the generator’s engine.
Match a pure inductive load with the machine with a pure induct ive load. The machine cannot be rated power with the same unit of power. The machine-rated power is only 40% to 75% of pure inductive load.

Rated Output

•
Altitude: 0 m
•
Ambient temperature: 25°C
•
Relative Humidity: 30%
Only under specified ambient temperature and c ooling can the gener ator be loaded to the rated power. If the working conditions do not meet these standar ds or t here is poor engine cooling (being run in a limited area), it should be adjusted to reduce the generator’s power.
10
Page 13
Petrol Powered Inverter Generator
Ambient Temperature Coefficient: C (30% RH)
Ambient Temperature (°C)
Altitude (m)
25 30 35 40 45
0
500
1,000
2,000
3,000
4,000
NOTE:
•
When the relative humidity is 60%, the ambient tem perature has an improved coefficient of C-0.01
•
When the relative humidity is 80%, the ambient tem perature has an improved coefficient of C-0.02
•
When the relative humidity is 90%, the ambient tem perature has an improved coefficient of C-0.03
•
When the relative humidity is 100%, the ambient temperature has an improved coefficient of C-0.04
Algorithm Example: When the generator power r ating PN = 2.0KW, altitude is 1000m, the ambient temper ature is 35°C , relative
humidity is 80%.
1 0.98 0.96 0.93 0.90
0.93 0.91 0.89 0.87 0.84
0.87 0.85 0.82 0.80 0.78
0.75 0.76 0.71 0.69 0.66
0.64 0.62 0.6 0.58 0.56
0.54 0.52 0.5 0.48 0.46
In t his enviro nment, the generator’s rated output of P = PN x (C-0.02) = 2.0 × (0.82-0. 02) = 1.6KW

Current Use

NOTE: 12V DC outlets are only for automatic battery charging. A DC socket must be present to monitor the battery voltage. If the battery voltage exceeds 16V, you must immediately st op supplying power to it. O therwis e, it can easily lead the battery to explode.
1. Connect the charging cable to the generator DC socket, then con nect it to the battery termin als.
11
Page 14
Petrol Powered Inverter Generator
NOTE:
− To disconnect the charging wir e w hen it is connected between the battery and the generator, disconnect
it next to the batt ery to prevent sparks from forming.
− W hen the chargi ng wire is connected t o a battery that is mounted on a car, first disconnect the battery
ground cable, charging cable, etc. Then, remove t he battery and connect the ground wire. Ensure that the battery terminals do not come in contact wit h the car chassis case to prevent short-circuitry or sparks from forming.
− When the generator is connected to the battery, do not start the car, otherwise it will damage the
generator.
− The charging wire and batter y wiring polarity should be correct, otherwise it will damage the generator or
the battery.
− While charging, there should be proper ventilation and steer clear from any sources of fire or strong heat.
The battery contains extrem ely volatile and flammable liquids.
− The battery contains s ulfuric acid. Contact with sk in or eyes may cause burns. Wear protective clothing
and face mask.
− Battery liquid is toxic substance! If splashed on skin, wash with water immediat ely.
− If batter y liquid splashes into the eyes, immediately flush them with water for 15 minutes and seek
professional medical attention.
− If you accidentally swal low battery liquid, immediately drink plenty of water or milk (you can also mix
magnesia or vegetable oil into the milk) and seek professional medical attention.
− The battery should be placed out of reach of children.
2. Start the engine
You can also use the AC, DC socket. DC overloads can activate the DC current protection switching function. If this happens, reset the switch.
12
Page 15
Petrol Powered Inverter Generator

Oil Alert System

The Oil Alert syst em is designed to prevent engine damage due to lack of lubricant and/or oil. Befor e the oil falls below the safet y line in the crankcase, the oil alert sys tem will auto matically shut down t he engine (the engine switch will remai n in the "ON" posit ion).
The Oil Alert system will turn off the engine if you try to st art the engi ne ag ain. The oil warning light (re d) will flash briefly when the engine is no longer running. I f this happens, add oil.

Switching Off the Generator

If in case of emergenc y shutdown, the engine switch should be positioned to “OFF”.

Normal Use

1. Turn off any connected devices, then pull out the plug.
2. Set the switch to the “off” position.
13
Page 16
Petrol Powered Inverter Generator
3. Set the oil switch to the “OFF” position.

Maintenance

Maintenance and adj ustment schedule was developed to ensure that the generator is kept in the best working condition.
CAUTION! Turn off the generator f irst before doing any maintenance on it. If the generator needs to be
maintained while it is still running, it must be done in a well-ventilated area. Exhaust from the generator contains poisonous carbon monoxide! Using inferior or unofficial parts not supplied by the manufacturer can
damage the generator.

Maintenance Schedule

Project
Engine oil
Air filter
Muffler
Spark plug
Periodic
maintenance
time1
Examine ○
Replace ○
Examine ○
Clean ○2
Examine ○
Clean ○
Clean/Adjust ○
Each
Use
Per month
or 20
hours
Every three
months or 50
hours
Every six
months or
100 hours
Every
year or
300 hours
Fuel
sediment
bowl
Lash
Tank and
filters
Oil
Clean ○
Check/Adjust ○3
Clean ○3
Examine Every two years ( If necessary, change3)
14
Page 17
Petrol Powered Inverter Generator
NOTES:
1
Normal maintenance intervals.
2
Maintain frequently if located in a heavily polluted area.
3
Periodic maintenance schedule is calculat ed according to the ambient temperature of 25°C. If the ambient
temperature exc eeds 30°C, please lessen the load power or shorten the oil change interval.

Changing the Oil

W hen the eng ine is hot, the quickly and thoroughly discharge the oil. NOTE: Press the stop switch first before changing the oil to ensure that the gr ip switch is turned off.
1. Discharge pipe into the oil filler neck, and then tighten it (in a random tool bag).
2. Roll the generat or, then pour out the oil.
3. Fill with the rec ommended oil, then check t he oil level.
4. After the additio n of t he new oil, shake the generator from side-to-side a few tim es to ensure that the oil alarm system will work.
Oil Capacity: 0.45L
15
Page 18
Petrol Powered Inverter Generator
NOTE: Please wash your hands wit h soap and water after changing the oil. In order to meet environmental requirements, we recommend that the old oil be sealed in a container and hand it
over to your local service station and recycli ng centre. Do not pour oil onto the ground or in the trash.

Air Filter Maintenance

A dirty air filter can block the airflow flowing into the carburettor, which could result in the carburettor malfunctioning. Maintain the air filter regularly, especially if you frequently use the generator in an area with a lot of dust and debris.
CAUTION! Do not use gasoline or low flashpoint solvents to clean the generator! T he y a r e highly flammable and
explosive under certain conditions. Check the air filter core, making sure it is clean and performing normally.
1. Remove the access panel to open the acces s cover.
2. Remove the three screws on the air filter cartridge.
3. Follow the a rrow shown in the figure below to pull out the air filt er drawer.
4. Pull out the air filter drawer, check the air filter and, if necessary, clean or replace the filter.
5. Clean or replace the filter before following t he op eration above in reverse.

Spark Plug Maintenance

Recommended usage of spark plugs: In order to ensure the normal operation of the generator, the spark plug gap must be appropriat e and no spark
plugs are producing any sparks.
1. Remove the top cover screws and open top access panel.
2. Pull out the side cover.
3. Remove the spark plug with a spark plug socket.
16
Page 19
Petrol Powered Inverter Generator
4. Visually inspect the spark plug if the insulator is broken, which must be discarded. If you want to re-use the spark plug again, use a brush to clean the spark plug.
5. Measure the spark plug g ap with a thickness gauge; the spark plug gap should be betwee n 0.6 – 0.7mm (0.024 – 0.028in).
6. Carefully instal l t he spark plug, being c areful not to dislocate it.
7. Install a new spar k plug with a wre nch a nd t ighten the ½ ring with a good pressure washer. If the old spark plug can still be used, use a wrench to tighten it to ¼ to 1/8 in.
8. Re-install the side cov er.
9. Re-install the top acc ess panel.
CAUTION!
•
Spark plug must be installed firmly, otherwise the spark plug can get very hot.
•
Do not use the same heating value for different s park plugs.

Muffler Maintenance

A dirty muffler will affect the muffling ef fect of the generator and the engine power. To ensure the normal operation of the generat or, clean the muffler periodically. I f you frequently use the ge ner ato r in an ar ea w ith a lot of dust and debris, you would need to frequently clea n the muffler or, if necessary, replace t he m uffler.
CAUTION! Clean-up must be done on the generator muffler. Make sure to check the engine muffler when the
generator is cold, a hot mu ffl e r can cause b urns.
1. Remove the hood scr ews to open the outlet cover plate.
2. Remove the two screws that are sec uring the muffler.
3. As shown in the f igure below, re move the muffler and the anti-flame barrier.
4. Clean or replace the anti-flame barrier, if necessary to avoid any potential fires from starting.
5. Clean or replace the anti-flame barrier and then f ollow the operation described above in reverse.
17
Page 20
Petrol Powered Inverter Generator

Transportation and Storage

NOTE: To prevent fuel leakag e during transportation or temporary st orage, turn o ff the o il switch. When transport ing the generator:
•
Do not fill up the fuel tank too much (filler should have no fuel i n i t ).
•
If the generator is still being transported, do not oper ate the generator. When the generator done being transported, store it in a well-ventilated area.
•
If the generator is transpor ted in vehicles, av oid exposing it to direct sunlight. If the generator placed inside a sealed compartment, the high temperature inside may lead to the fuel becoming volatile, potentially causing an explosion.
•
Do not transport the generator for a long time on rough roads and terrains. If necessary, drain all the fuel first before tr ansporting the generator.
Before storing the generator for an extended time:
•
Ensure that the storage area is dry and clean.
•
Drain all of the fuel.
WARNING! Under certain conditions, fuel can becom e extremely flammable! Ensure that there are no
sources of fire or strong heat in the storag e area of the generator.
1. Fuel should be kept in a single, spare c ontai ner. Turn ON the oil switch a nd start the engine. Run it to burn any remaining fuel. The engine will then automatic ally turn OFF afterwards.
18
Page 21
Petrol Powered Inverter Generator
2. Drain the oil.
3. Remove the spark plug, then pour a tablespoon of clean engine oil into the cyli nder, pulling the handle several times to start the bulk of oil spill, and then instal l the spark plug.
4. Slowly pull the handle to feel the pressure. T his t ime, the piston should be raised to the top of its compr ession stroke and the exhaust valves should be closed. In this case, the internal storage helps prevent the engine from rusting.
19
Page 22
Petrol Powered Inverter Generator

Troubleshooting

Generator Isn’t Starting

NOTE: If the generator cannot be started when pulling the starting handle oil after the warning light flashes, lightly shake the generator side-to-side a few times to ensure that the oil alarm system is working properly. If you still cannot start the generator, please start troubleshooting. Ensure that no fuel is spilt on the spark plug. Spilled fuel could catch fire.
1. Remove the side cover and clean away the dirt around the spark plug.
2. Remove the spark plug, the spark plug will be loaded inside the side cover.
3. With a wire, connect the spark plug side electrode to the m etal parts of the engine to the ground. (Available with a DC output li ne replacement wire with a clip of a clamped metal part of the engine. Plug the other end to the same polarity connected to the spark plug guide posts on the side of the pole).
4. Pull the start ing handle, the spark gap should skipped.
CAUTION! Ensure that the engine is cold when checking the spark plug. A hot spark plug can caus e burns.
20
Page 23
Petrol Powered Inverter Generator

Devices Connected to the Generator Isn’t Starting

No Charge in DC Socket

21
Page 24
Petrol Powered Inverter Generator

Power Shortage

Technical Specifications

Max Output
Continuous Rated Output1
AC Voltage
Output Type
DC Output
USB Socket
1
PLEASE NOTE: 'Cont inuous Rated Output' is what power this generator consistently and reliably provide. We
strongly r ecom m end that you consider this figure w hen determining whether this model suits your requirements. For more informat ion about selecting the right generator view the Buying Guide
3700W / 3.7kW / 3. 7k VA
3200W / 3.2kW / 3. 2k VA
240V 50Hz 240V 15A m p socket 12V - 8.3A Dual
.
22
Page 25
Some experts believe the incorrect or prolonged use of almost any product could cause serious injury or death. For inf
orm
ation that may reduce your risk of serious injury or death consult thepoints below and additionally, the information available at www.datastreamserver.com/safety
- Consult all docume ntation, packaging and product labelling before use. Note that some products feature online documentation which should be printed and kept with the p roduct.
- Check product for loose / broken / damaged / missing parts, wear or leaks (if applicable) before each use. Never use a product with loose / b roken / damaged / missing pa rts, wear or leaks (if applicable).
- Products must be inspected and serviced (if applicable) by a qualified specialist every 6 months assuming average residential use by a person of average weight and strength, ab ove average technical aptitude, on a property matching average metropolitan specification. Intended use outside these guidelines could indicate the product is not suitable for intended use or may require more regular inspection or servicing.
- Ensure all possible users of the p roduct have completed an industry recognised training course before being given access to the product.
- The product has been supplied by a general merchandise retailer that may not be familiar with your specific applic ation or your description of the applic ation. Be sure to attain third party approval for your application from a qualified specialist before use regardless of prior assurances by the retailer or its representatives.
- This product is not intended for use where fail-safe operation is required. As with any product (take an au tomobile, aircraft, computer or ball poi nt pen for example) there is always a small chance of a technical issue that needs to be repaired or may require replacement of the product or a part. If the possibility of such failure and the associated time it takes to rectify could in any situation inconvenience the user, business or employee or could financially affect the user, business or employee then the product is not suitable for your requirements. This p roduct is not for use where incorrect operation or a failure of any kind, including but not limited to a condition requiring product return, replacement, service by a technician or replacement of parts could cause a financial loss, loss of employee time or an in c
onvenience
requiring compensation.